Signal conditioning instruments

Similar documents
Signal conditioning instruments

Process transmitter RMA422

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Process Transmitter RMA 422

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

TFRH Hygienic RTD temperature sensor. CombiTemp TM

TFRN Industrial RTD temperature sensor. CombiTemp TM

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

RMA42. Technical Information

Operating Instructions VEGAMET 625 Double channel HART signal conditioning instrument

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Fibre Optic Modem ODW-611

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

TFRN Industrial RTD temperature sensor. CombiTemp TM

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

ODW-621. RS-232 Point-to-point applications

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Capacitance Level Measurement Electronic insert FEC 12

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Fibre optic router for TP/FT-10 LRW-112PP

Operating Instructions VEGAMET ma/hart signal conditioning instrument

Operating Instructions VEGAMET ma/hart signal conditioning instrument

DMP 331i / DMP 333i LMP 331 i

LONWORKS Fibre Optic Router

Fibre Optic Modem ODW-622

Inductive sensor NI3-EG08K-Y1-H1341

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LONWORKS Fibre Optic Converter

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

ATEX-manual for units

Inductive sensor BI1.5-EG08K-Y1

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Capacitance Limit Detection nivotester FTC 420/421/422

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Pressure transmitter For applications in hazardous areas Model IS-3

Technical Information RIA45

Generator protection relay

TFR5 Room or outdoor temperature sensor. CombiTemp TM

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Rack mounted telephone- and leased line modem for industrial applications

Flow Measurement SITRANS F M

SITRANS F M. Transmitter MAG 5000/6000 4/33

Flow Measurement SITRANS F M

ACT20X Series for hazardous area applications Section A

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Wall-/Pipe-Mount Level Indicator

Inductive sensor NI10-M18-Y1X-H1141

02/11/2015

Operating Instructions VEGAMET 625 Double channel Hart signal conditioning instrument

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Level Measurement silometer FMC 420, FMC 423

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

8 Installation Equipment

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Fieldbus Components Section K

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

High performance circuit breakers

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Datasheet - SRB301LC 24VAC/DC

Level Measurement. Continuous level measurement Radar transmitters. SITRANS LR250 Flanged Encapsulated Antenna. 4/228 Siemens FI

Ordering details. Approval. Classification

IMPAC Infrared Thermometers

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Photoelectrics Through-beam Type PA18C.T..., DC

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

PMG. Vibration Energy Harvesters

Multi-functional safety relay modules PROTECT SRB-E

Datasheet - SRB-E-201ST

SCALE & WEIGHT DISPLAYS

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Pendant Light Fitting IEC Series 6470/2

General Specifications

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

HARTING Ethernet cabling cables and connectors, 4 wire

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

Actuators IC 20, IC 40

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

LD OEM/LD PDS/LD PeCo

IPS 2400 SMAVIA Appliance for up to 24 IP Channels, 8 3.5" HDD, 3 HU

Circuit-Breakers for Motor Protection Series 8523/8

Inductive sensor With analog output BI15-M30-LI-EXI

Level Measurement Point level measurement - RF Capacitance switches

Transcription:

Signal conditioning instruments Overview Page 242 VEGAMET Page 244 VEGASCAN Page 248 VEGASTAB Page 249 VEGATOR Page 250 ISO housing Page 258 Components Page 259 2 24

Signal conditioning instruments For power supply of sensors and further processing of measured values Functional principle With a continuous level measurement, e.g. the level in a vessel is detected by a sensor and transferred to the VEGAMET signal conditioning instrument for further processing. Through an adjustment in VEGAMET, the measured value can be adapted to the individual conditions. The requested parameter is shown in the display and outputted via the integrated current outputs. Hence the measuring signal can be transmitted to an external indication or superior control. Up to six operating relays are also integrated in each signal conditioning instrument for level detection. These can be used for control of pumps or other actors. Applications The signal conditioning instruments offer a number of applications, e.g. level, gauge, differential, differential pressure, process pressure, distance, interface and temperature measurement. Overview Instrument type Input Hysteresis Output Operating voltage VEGAMET 38 x 4 20 ma sensor input adjustable x 0/4 20 ma current output 2 x relay outputs x fail safe relay 20 253 V AC, 50/60 Hz, 20 253 V DC VEGAMET 39 x 4 20 ma/hart sensor input adjustable x 0/4 20 ma current output 6 x relay outputs or 5 x relay outputs and x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC VEGAMET 624 x 4 20 ma/hart sensor input adjustable 3 x 0/4 20 ma current output 3 x relay outputs x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC VEGAMET 625 2 x HART sensor input adjustable 3 x 0/4 20 ma current output 3 x relay outputs x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC VEGASCAN 693 5 x HART sensor input --- x fail safe relay x Ethernet (optional) or x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC VEGASTAB 690 --- --- 24 V DC (floating, short circuit proof) 20 253 V AC, 50/60 Hz, 20 72 V DC 242 Signal conditioning instruments

Overview Instrument type Input Hysteresis Output Operating voltage VEGATOR Single channel signal conditioning instrument acc. to NAMUR x sensor input NAMUR (IEC 60947-5-6) fix x relay output (SPDT) Optionally fail safe relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 2 Double channel signal conditioning instrument acc. to NAMUR 2 x sensor input NAMUR (IEC 60947-5-6) fix 2 x relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 2 Single channel signal conditioning instrument for level detection x sensor input two-wire 8/6 ma fix x relay output (SPDT) Optionally fail safe relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 22 Double channel signal conditioning instrument for level detection 2 x sensor input two-wire 8/6 ma fix 2 x relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 4 Single channel signal conditioning instrument for level detection x 4 20 ma sensor input (active) or x 4 20 ma sensor input (passive) adjustable x relay output (SPDT) Optionally fail safe relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 42 Double channel signal conditioning instrument for level detection 2 x 4 20 ma sensor input (active) or 2 x 4 20 ma sensor input (passive) adjustable 2 x relay output (SPDT) 20 253 V AC/DC, 50/60 Hz VEGATOR 256C Signal conditioning instrument for conductive probes Single channel fix x relay output 20 250 V AC, 50/60 Hz VEGATOR 632 Signal conditioning instrument for conductive probes Double channel fix 2 x relay output 85 253 V AC, 50/60 Hz or 20 30 V AC, 50/60 Hz, 20 60 V DC 2 Signal conditioning instruments 243

VEGAMET 38 Signal conditioning and display instrument for level sensors The VEGAMET 38 signal conditioning instrument powers the connected 4 20 ma/hart sensor, processes and displays the measured values. The VEGAMET 38 is ideal for simple control tasks in all industries. Comprehensive adjustment functions enable individual adaptations to the respective application. Transmitter power supply via the 4... 20 ma sensor input Versatile use through two relay outputs to control pumps and stirrers, etc. Easily readable LC display for digital and quasianalogue measured value indication Input: Mounting: SIL qualification: x 4 20 ma sensor input x 0/4 20 ma current output 2 x relay outputs x fail safe relay 20 253 V AC, 50/60 Hz, 20 253 V DC front panel, wall mounting carrier rail 35 x 7.5 acc. to EN 50022 optionally up to SIL2 Approval XX without... CX ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D]... CI IEC [Zone 0] [Ex ia] IIC, [Zone 20] [Ex ia D]... MET38. 2 2 92 mm (3.62") 02 mm (4.02") mm (4.37") % on 96 mm (3.78") 9 mm (0.75") 69 mm (2.72") 2 mm (0.08") 96 mm (3.78") 244 Signal conditioning instruments VEGAMET 38

VEGAMET 39 Signal conditioning and display instrument for level sensors The VEGAMET 39 signal conditioning instrument powers any 4 20 ma/hart sensor, processes and displays the measured values. The VEGAMET 39 is perfectly suitable for simple control tasks in level, gauge and process pressure measurements as well as for inventory management (VMI) and remote enquiry. Comprehensive adjustment functions allow individual adaptations to the respective application. In the water/sewage water industry, the instrument impresses with special functions such as pump switching-over, flow volume measurement, tendency functions and totalizer. Steady utilization of the pumps through integrated pump management Completely integrated function unit for flow volume measurement Simple integration in the Intranet/Extranet through integrated Web server Input: Mounting: SIL qualification: x 4 20 ma/hart sensor input with transmitter power supply x 4 20 ma/hart sensor input passive x 0/4 20 ma current output up to 6 x relay outputs x fail safe relay x Ethernet or x RS232 optionally 20 253 V AC, 50/60 Hz, 20 253 V DC front panel or wall mounting carrier rail 35 x 7.5 acc. to EN 50022 optionally up to SIL2 Approval XX without... CX ATEX II ()G [Ex ia Ga] IIC, II ()D [Ex ia Da] IIIC, I (M) [Ex ia Ma] I... CX IEC [Ex ia Ma] I [Ex ia Ga] IIC [Ex ia Da] IIIC... Version H 4... 20 ma/hart input... Communication interface X without... R RS232 incl. connection cable... E Ethernet... Mounting X Panel or wall mounting... H Carrier rail 35x75 according to EN50022... MET39. 2 VEGAMET 39 00 mm (3.94") 9,5 mm (4.7") 2 3 4 5 6 96 mm (3.78") on ESC OK 40 mm (5.5") 96 mm (3.78") mm (4.37") Signal conditioning instruments VEGAMET 39 245

Ser. No. 2345678 VEGAMET 624 Signal conditioning and display instrument for level sensors The VEGAMET 624 signal conditioning instrument powers the connected 4 20 ma/hart sensor, processes and displays the measured values. The VEGAMET 624 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application. Steady utilization of the pumps through integrated pump management Simple integration in the Intranet/Extranet through integrated Web server Simple data recording and history retrieval with instruments with digital interface Input: x 4 20 ma/hart sensor input with transmitter power supply 3 x 0/4 20 ma current output 3 x relay outputs x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Approval XX without... CX ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D]... CM ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D] + Ship approval... CI IECEx ia IIC T6... Communication interface X without... R RS232 incl. connection cable... E Ethernet... MET624. 2 2 3 4 5 6 7 8 Transparent cover 2 Carrier rail 35 x 7.5 or 35 x 5 acc. to EN 50022 2 3 COM ESC OK 8,5 mm (4.67") 54,5 mm (2.5") on VEGAMET 9 0 2 3 4 5 6 7 8 20 2 22 23 24 25 26 27 28 34 mm (5.28") 72 mm (2.84") 246 Signal conditioning instruments VEGAMET 624

Ser. No. 2345678 VEGAMET 625 Signal conditioning and display instrument for level sensors The VEGAMET 625 signal conditioning instrument powers the connected 4 20 maa/hart sensor, processes and displays the measured values received through HART Multidrop. The VEGAMET 625 is ideal for simple control tasks in level, gauge and process pressure measurements. For inventory management in remote storage silos, interfaces for simple remote data transmission are integrated. Comprehensive adjustment functions enable individual adaptations to the respective application. Versatile use through three scalable current outputs for control of indications and connected systems such as e.g. a PLC Simple integration in the Intranet/Extranet through integrated Web server Simple data recording and history retrieval with instruments with digital interface Input: 2 x 4 20 ma/hart sensor input with transmitter power supply (only HART capable sensors) 3 x 0/4 20 ma current output 3 x relay outputs x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz, 20 253 V DC Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Approval XX without... CX ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D]... CM ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D] + Ship approval... CI IECEx ia IIC T6... Communication interface X without... R RS232 incl. connection cable... E Ethernet... MET625. 2 2 2 3 4 2 3 COM ESC 5 6 7 8 OK 8,5 mm (4.67") Transparent cover 2 Carrier rail 35 x 7.5 or 35 x 5 acc. to EN 50022 54,5 mm (2.5") on VEGAMET 9 0 2 3 4 5 6 7 8 20 2 22 23 24 25 26 27 28 34 mm (5.28") 72 mm (2.84") Signal conditioning instruments VEGAMET 625 247

Ser. No. 2345678 VEGASCAN 693 Signal conditioning instrument for up to 5 HART sensors The VEGASCAN 693 is a signal conditioning and display instrument for up to 5 continuously measuring 4... 20 ma/hart sensors. It processes the measured value received via HART multidrop and displays the values. Hence measurement results from level, gauge and process pressure measurements can be easily made available to control systems, visualizations and the remote data transmission. Interfaces and functions for the connection to networks and the remote data transmission are integrated. It is particularly suitable for applications in the local and global inventory management. Data recording of up to 200,000 measured values with instruments with digital interface Simple integration in the Intranet/Extranet through integrated Web server Measured value and message transmission via e-mail and SMS and data transmission to VEGA Inventory System Input: up to 5 HART-capable sensors up to 5 sensors with Ex applications (with transmitter power supply and passive) x fail safe relay x Ethernet (optional) x RS232 (optional) 20 253 V AC, 50/60 Hz 20 253 V DC Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Approval XX without... CX ATEX II ()G [Ex ia] IIC, II ()D [Ex ia D]... CI IECEx ia IIC T6... Communication interface R RS232 incl. connection cable... E Ethernet... SCAN693. 2 2 3 4 5 6 7 8 Transparent cover 2 Carrier rail 35 x 7.5 or 35 x 5 acc. to EN 50022 2 3 COM ESC OK 8,5 mm (4.67") 54,5 mm (2.5") on VEGAMET 9 0 2 3 4 5 6 7 8 20 2 22 23 24 25 26 27 28 34 mm (5.28") 72 mm (2.84") 248 Signal conditioning instruments VEGASCAN 693

VEGASTAB 690 Power supply unit for power supply of two analogue sensors VEGASTAB 690 is a power supply unit for independent power supply of two 4 20 ma sensors/circuits. Interference-free operation through two galvanically separated supply current circuits High reliability through permanently shortcircuit-proof circuits Integrated interlock diode for interruption-free connection of a measuring instrument 20 253 V AC, 50/60 Hz 20 72 V DC 2 x 24 V DC (floating) Current limitation: approx. 26 ma Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Plug-in socket K Inclusive plug-in socket... STAB690.X 2 2 3 4 8,5 mm (4.67") 2 Transparent cover 2 Carrier rail 35 x 7.5 or 35 x 5 acc. to EN 50022 54,5 mm (2.5") on 5 6 7 8 9 0 2 3 4 34 mm (5.28") 36 mm (.42") Signal conditioning instruments VEGASTAB 690 249

VEGATOR Single channel signal conditioning instrument acc. to NAMUR (IEC 60947-5-6) for level detection The VEGATOR is a signal conditioning instrument for level detection for vibrating level switches VEGASWING, VEGAVIB and VEGAWAVE with electronics version according to NAMUR (IEC 60947-5-6). With this instrument, simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection. Optionally a false signal output is available. Comprehensive monitoring detects short-circuit and line break of the measuring cable and interferences in the sensor Simple and comfortable line monitoring by means of test key Simple installation through carrier rail mounting as well as detachable, coded terminals Input: x sensor input NAMUR (IEC 60947-5-6) x relay output (SPDT) optionally x fail safe relay output (SPDT) 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail mounting 35 x 7.5 according to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Single channel according to NAMUR (IEC60947-5-6)... S Single channel according to NAMUR (IEC60947-5-6), with fail safe relay... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... TOR. 20 mm (0.79") 3 mm (4.45") OPEN 52 mm (2.05") 08 mm (4.25") 92 mm (3.62") ON 46 mm (.8") 56 mm (2.20") 250 Signal conditioning instruments VEGATOR

VEGATOR 2 Double channel signal conditioning instrument acc. to NAMUR (IEC 60947-5-6) for level detection The VEGATOR 2 is a signal conditioning instrument for level detection for vibrating level switches VEGASWING, VEGAVIB and VEGAWAVE with electronics version according to NAMUR (IEC 60947-5-6). With this instrument, simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection. Comprehensive monitoring detects short-circuit and line break of the measuring cable and interferences in the sensor Simple and comfortable line monitoring by means of test keys for both channels Simple installation through carrier rail mounting as well as detachable, coded terminals Input: 2 x sensor input NAMUR (IEC 60947-5-6) 2 x relay output (SPDT) 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail mounting 35 x 7.5 acc. to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Double channel according to NAMUR (IEC 60947-5-6)... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: 2 x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: 2 x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... 20 mm (0.79") 3 mm (4.45") OPEN mm (4.37") 92 mm (3.62") 2 TOR2. 55 mm (2.7") 2 ON 46 mm (.8") 56 mm (2.20") Signal conditioning instruments VEGATOR 2 25

VEGATOR 2 Single channel signal conditioning instrument for level detection The VEGATOR 2 is a signal conditioning instrument for level detection for the vibrating level switches VEGASWING, VEGAVIB and VEGAWAVE with electronics version "Two-wire 8/6 ma. With this instrument simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection. Optionally a false signal output is available. Comprehensive monitoring detects short-circuit and line break of the measuring cable and interferences in the sensor Simple and comfortable line monitoring by means of test key (also for SIL and WHG) Simple installation through carrier rail mounting as well as detachable, coded terminals Input: x sensor input two-wire 8/6 ma x relay output (SPDT) optionally x fail safe relay output (SPDT) 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail 35 x 7.5 acc. to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... U ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + WHG... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... U IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + WHG... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Single-channel (8/6mA) for level detection... S Single channel (8/6mA), level detection with fail safe relay... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... TOR2. 20 mm (0.79") 3 mm (4.45") OPEN 52 mm (2.05") 08 mm (4.25") 92 mm (3.62") ON 46 mm (.8") 56 mm (2.20") 252 Signal conditioning instruments VEGATOR 2

VEGATOR 22 Double channel signal conditioning instrument for level detection The VEGATOR 22 is a signal conditioning instrument for level detection for the vibrating level switches VEGASWING, VEGAVIB and VEGAWAVE with electronics version "Two-wire 8/6 ma. With this instrument simple control tasks can be solved. Typical applications are monitoring functions such as overflow or dry run protection. Comprehensive monitoring detects short-circuit and line break of the measuring cable and interferences in the sensor Simple and comfortable line monitoring by means of test keys for both channels (also for SIL and WHG) Simple installation through carrier rail mounting as well as detachable, coded terminals Input: 2 x sensor input two-wire 8/6 ma 2 x relay output (SPDT) 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail 35 x 7.5 acc. to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... U ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + WHG... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... U IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + WHG... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Double-channel (8/6mA) for level detection... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: 2 x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: 2 x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... 20 mm (0.79") 3 mm (4.45") OPEN mm (4.37") 92 mm (3.62") 2 TOR22. 55 mm (2.7") 2 ON 46 mm (.8") 56 mm (2.20") Signal conditioning instruments VEGATOR 22 253

VEGATOR 4 Single channel signal conditioning instrument for level detection The VEGATOR 4 is a signal conditioning instrument for level detection for continuously measuring 4 20 ma sensors. It evaluates the measured values of a sensor and delivers a switching signal according to the adjusted switching threshold. Hence simple control tasks can be solved. Typical applications are monitoring functions such as overflow and dry run protection as well as gauge monitoring. Optionally a false signal output is available. Simple adjustment of the switching point through a potentiometer Clearly visible switching status via LED Simple installation through carrier rail mounting as well as detachable, coded terminals Input: x 4 20 ma sensor input active (Ex and non-ex) alternatively x 4 20 ma sensor input passive (non-ex) x relay output (SPDT) optionally x fail safe relay output (SPDT) adjustable Integration time: 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail 35 x 7.5 acc. to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... U ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + WHG... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... U IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + WHG... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Single-channel, 4... 20 ma for level detection... S Single-channel, 4... 20 ma for level detection with fail safe relay... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... TOR4. 20 mm (0.79") 3 mm (4.45") OPEN 52 mm (2.05") 08 mm (4.25") 92 mm (3.62") ON 46 mm (.8") 56 mm (2.20") 254 Signal conditioning instruments VEGATOR 4

VEGATOR 42 Double channel signal conditioning instrument for level detection The VEGATOR 42 is a signal conditioning instrument for level detection for continuously measuring 4 20 ma sensors. It evaluates the measured values of a sensor and delivers a switching signal according to the adjusted switching threshold. Hence simple control tasks can be solved. Typical applications are monitoring functions such as overflow and dry run protection as well as gauge monitoring. Optionally a false signal output is available. Simple adjustment of the switching point through a potentiometer Clearly visible switching status via LED Simple installation through carrier rail mounting as well as detachable, coded terminals Input: 2 x 4 20 ma sensor input active (Ex and non-ex) alternatively 2 x 4 20 ma sensor input passive (non-ex) 2 x relay output (SPDT) adjustable Integration time: 20 253 V AC/DC, 50/60 Hz Mounting: carrier rail 35 x 7.5 acc. to EN 50022 SIL qualification: optionally up to SIL2 Scope A Europe... I Worldwide... Approval X for Ex-free area... M Ship approval... A ATEX II 3G Ex na nc ic IIC T4 Gc + II () G/D [Ex ia Ga/Da] IIC/IIIC... C ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I... U ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + WHG... O ATEX II () G/D [Ex ia Ga/Da] IIC/IIIC, I (M) [Ex ia Ma] I + Ship approval... A IEC Ex na nc ic IIC T4 Gc + [Ex ia Ga/Da] IIC/IIIC, [Ex ia Ma] I... C IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I... U IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + WHG... O IEC [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I + Ship approval... Version X Double channel 4... 20 ma for level detection... SIL qualification X without... S with, incl. Safety Manual... Housing / Protection K Plastic / IP20... Terminal blocks / Connection X detachable 2.5mm² / Sensor: 2 x black; output and operating voltage: 2 x black... B detachable 2.5mm² / Ex sensor: 2 x blue; output and operating voltage: 2 x black... Certificates M Yes... X no... 20 mm (0.79") 3 mm (4.45") OPEN 42 mm (4.37") 92 mm (3.62") 2 TOR42. 55 mm (2.7") 2 ON 46 mm (.8") 56 mm (2.20") Signal conditioning instruments VEGATOR 42 255

R VEGATOR 256C Signal conditioning instrument for conductive electrodes The VEGATOR 256C is a signal conditioning instrument for conductive electrodes EL EL 8. Applications are simple level detections or pump controls. Compact unit of voltage supply and processing of a conductive probe Simple adjustment of the switching point via a potentiometer Simple installation through carrier rail mounting Input: x level detection or x pump control x relay output Response sensitivity: 200 kohm adjustable Switching hysteresis: approx. 20 % 20 250 V AC, 50/60 Hz Mounting: wall mounting carrier rail 35 x 7.5 acc. to EN 50022 Operating voltage E 24V AC... B 00...30V AC... A 200...250V AC... TOR256C.X min. max. 2 3 0 0 L 4 5 6 7 N 8 power supply 200...250VAC 3VA Relais: max 250V, 5A, 750VA 68 mm (2.68") 37 mm (.46") 66 mm (2.6") 256 Signal conditioning instruments VEGATOR 256C

VEGATOR 632 Signal conditioning instrument for conductive electrodes The VEGATOR 632 is a double channel signal conditioning instrument for conductive electrodes type EL. Applications are level detections and pump controls. In conjunction with multiple rod or cable electrodes several VEGATOR 632 can be combined with the probe. Two independent level detections or one min./max. control (two-point control) Integrated fault monitoring with LED indication detects shortcircuit and line break Simple mounting through carrier rail Input: double channel 2 x relay output Response sensitivity: adjustable (max. 200 kohm) 85 253 V AC, 50/60 Hz or 20 30 V AC, 50/60 Hz, 20 60 V DC Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Approval XX without... CX ATEX II () G [Ex ia] IIC/IIB + II () D [Ex iad]... CA ATEX II () G [Ex ia] IIC/IIB + II () D [Ex iad] + WHG... Version D 20...30V AC / 20...60V DC... A 90...250V AC... TOR632. 22,5 mm (0.89") 2 mm (4.4") 95 mm (3.74") 08 mm (4.25") 2 Signal conditioning instruments VEGATOR 632 257

ISO housing Protective housing with transparent cover for surface mounting The ISO housing is a robust field housing for wall mounting, for mounting of VEGAMET series 300 and VEGAMET series 600 signal conditioning instruments. Protective housing in protection IP 65 Attached carrier rail 35 x 7.5 acc. to EN 50022 Including mounted cable glands Instrument type AXX suitable for one VEGAMET 39... CXX suitable for up to three series 600 instruments... BXX suitable for one VEGAMET 38... ISO-GEH. 25 mm (4.92") 50 mm (5.9") 25 mm (4.92") 26 mm (4.96") 200 mm (7.87") 90 mm (7.48") 0 mm (0.39") 300 mm (.8") 326,5 mm (2.85") 0 mm (0.39") 0 mm (0.39") 75 mm (6.89") 205 mm (8.07") 75 mm (6.89") 205 mm (8.07") 0 mm (0.39") ISO housing suitable for up to three series 600 instruments Depending on the housing width 0 mm (0.39") ISO housing suitable for VEGAMET 38 0 mm (0.39") ISO housing suitable for VEGAMET 39 258 Signal conditioning instruments ISO housing

GPRS/EDGE Router LUCOM GPRS/EDGE router for remote enquiry of measured values The GPRS/EDGE router is suitable for wireless remote enquiry of measured values and for remote parameter adjustment of communication-capable VEGA instruments, especially with VEGA Inventory System and PACTware. They are used when the wiring of a cable is too complex or not possible. Especially suitable for connection to signal conditioning instruments with Ethernet interface such as for example VEGAMET 39, VEGAMET 624, VEGAMET 625, VEGASCAN 693 or PLICSRADIO C62. Universal use through standardized GPRS Simple parameter adjustment on site via standard interfaces Combination of router, modem and single or also multiple Ethernet Port Supply voltage: 0 30 V DC Power consumption: during reception: W during emission: 5.5 W Ambient temperature: -30 +60 C Dimensions W x H x D: 42 x 76 x 3 mm (DIN 35 mm) Weight: 50 g Standards: EN 30 5, V9.0.2 EN ETSI 30 489- V.9. EN 60950-:06 ed.2 + A:09 Frequency bands: EGSM850, EGSM900, GSM800 and GSM900 Mounting: carrier rail 35 x 7.5 according to EN 50022 Version LXX GPRS/EDGE modem ER75i v2b LUCOM for signal conditioning instrument... EXX GPRS/EDGE modem ER75 v2f LUCOM for several signal conditioning instruments... ROUTER. 2 Signal conditioning instruments Components 259

Modem antenna Antenna for connection to GPRS/EDGE Router For use in conjunction with the GPRS/EDGE Router. Suitable antennas are available for different applications. Alternative, optimized solutions possible through use of different antenna versions Time saving on installation due to attached, adapted connection cable Universal use in- and outdoors Technial data Versions: Frequency band: Connection cable: outer wall antenna patch antenna magnetic foot antenna GSM/GPRS attached, dependent on the version 2.5 5 m Version Outer wall antenna Triband with mounting bracket, 5 m cable... 2 GSM patch antenna quad-band with 3 m cable... SMA adapter A with... MODEMANT. Analogue modem Analogue industry modem for remote measured value enquiry The analogue industry modem is suitable for remote measured value enquiry of communication-capable VEGA instruments with VEGA Inventory System and PACTware. They are used in case of a large distance from the sensor to the processing. Particularly suitable for connection to signal conditioning instruments with RS232 interface such as for example VEGAMET 39, VEGAMET 624, VEGAMET 625, VEGASCAN 693 or PLICSRADIO C62. Universal use through standardized, analogue telephone connection Reliable and interference-free function by high precision 3-way separation and integrated overvoltage arrester Minimum time and cost expenditure thanks to industrial-suited housing with simple fixing facility on carrier rail Supply voltage: 0 60 V DC or 6 40 V AC Power consumption: < 00 ma (24 V) in nominal operation Transmission rate: data rate recognition up to 5.2 kbit/s Ambient temperature: 0 55 C Protection: IP 20 Galvanic separation: 3-way separation power supply, PSTN and RS232 Mounting: carrier rail 35 x 7.5 according to EN 50022 Modem JX Industrial modem RS232 for carrier rail mounting... MODEM. 260 Signal conditioning instruments Components

Ethernet-Profibus interface Ethernet Profibus interface ensures access from parameter software (PACTware) to field device The TH-LINK.X is an Ethernet Profibus Interface providing the connection between the higher-level network and the field level. Hence the access of the parameter software PACTware from the Ethernet to the Profibus network is ensured. A separate PCMCIA card for the PC is not required. Furthermore diagnosis possibilities are available to ensure the network stability. Hence the Profibus systems can be operated economically. Unique platform for network diagnosis and parameter adjustment Simple installation and setup through WEB server and DTM Central access to all parameters of the Profibus sensors in the network Supply voltage: 9.2 28.8 V DC Current consumption: 90 ma Temperature range: 0 +50 C Profibus baud rate: max. 2 Mbit/s Profibus interface: RS485 Ethernet interface: RJ 45 Mounting: carrier rail 35 x 7.5 according to EN 50022 Dimensions W x H x D: 22.5 x 99 x 4.5 mm Weight: 20 g Communication DTM: available Version 43060 TH-Link Ethernet-Profibus DP coupler... KOMZUB- 2 Signal conditioning instruments Components 26

Profibus PA/DP segment coupler Segment coupler from Profibus DP to Profibus PA For use in conjunction with Profibus DP/PA bus systems. The segment coupler is suitable for coupling and power supply of Profibus PA networks. The Ex version ensures Ex intrinsic safety in conjunction with Ex circuits. Simple setup because no own GSD, DTM or EDD file or Profibus address must be used Reliable connection to Ex circuits by standardized FISCO procedure Economical, compact version with up to 0 Ex or 32 non-ex field devices Profibus PA power supply: Profibus DP baud rate: Galvanic separation: 24 V with 400 ma or 3 V with 00 ma (Ex) 93.75 kbit/s between power supply, Profibus DP and Profibus PA Ambient temperature: -20 +60 C Protection: IP 20 Mounting: carrier rail 35 x 7.5 acc. to EN 50022 Approval.X without... EX.X ATEX II () G D [Ex ia] IIC... PA-KOPPLER 2 3 6 7 8 4 5 6 9 20 2 7 8 9 22 23 24 0 2 25 26 27 3 4 5 28 29 30 3 32 33 46 47 48 34 35 36 49 50 5 37 38 39 52 53 54 40 4 42 55 56 57 43 44 45 58 59 60 07 mm (4.2") 2 mm (4.4") 00 mm (3.94") 262 Signal conditioning instruments Components

PA coupler SK-3 Segment coupler from Profibus DP to Profibus PA The segment coupler is used for coupling and power supply of Profibus PA networks. The coupler combines two different networks for data transmission and delivers the current for the Profibus DP segment. Data are transmitted from the Profibus DP master via the segment coupler to the PA field device. In conjunction with Profibus DP, the segment coupler supports a baud rate of up to 2 Mbit/s. Simple setup because no own GSD, DTM or EDD file or Profibus address must be used Flexible through support of baud rates of up to 2 Mbit/s on the Profibus DP side Economical solution through power supply of up to two different PA segments Profibus PA power supply: Profibus DP baud rate: Galvanic separation: 25 V with 360 ma 2 Mbit/s between power supply, Profibus DP and Profibus PA Ambient temperature: -40 +60 C Protection: IP 20 Mounting: carrier rail 35 x 7.5 acc. to EN 50022 PA-KOPPLERSK3 200 mm (7.87") 2 08 mm (4.25") 62 mm (6.38") Signal conditioning instruments Components 263

Profibus PA T-distributor Distributor for Profibus PA bus systems Profibus PA T-distributors are used for coupling of Profibus PA transmitters to the Profibus PA bus cable Simple connection possibilities through star distributor via M2 plug connector or distribution terminal Optimized cable glands allow an EMC-compatible wiring Simple bus configuration through integrated bus termination with non-ex versions Connection: Screening: Sensor connection:, 2, 4 and 8-fold star distributor through the EMC cable gland to the housing M2 plug connection or directly on the distributor Version 29322 -way Profibus PA T-distributor EMC cable gland... 29323 2-way Profibus PA T-distributor EMC cable gland... 29324 4-way Profibus PA T-distributor EMC cable gland... 29326 -way Profibus PA T-Connector M2 plug connection... 27372 2-way Profibus PA T-distributor M2 plug connection... 2737 4-way Profibus PA T-distributor M2 plug connection... 2506 -way EEx Profibus PA T-distributor EMC cable gland... 2934 2-way EEx Profibus PA T-distributor EMC cable gland... 2936 4-way EEx Profibus PA T-distributor EMC cable gland... 2938 -way EEx Profibus PA T-distributor M2 plug connection... 2939 2-way EEx Profibus PA T-distributor M2 plug connection... 29320 4-way EEx Profibus PA T-distributor M2 plug connection... 25062 FBC on EEx BUS termin. w.o stopper/w.o ground connect.... 2. 25 mm (4.92") 2 mm (4.4") 58 mm (2.28") 68 mm (2.68") 80 mm (3.5") 264 Signal conditioning instruments Components

Ethernet switch 8-fold Ethernet switch Suitable for connection to signal conditioning instruments VEGAMET 39, VEGAMET 624/625, VEGASCAN 693 and PLICSRADIO C62 with Ethernet interface to an Ethernet or PC network. Robust version for use under arduous ambient conditions Ideal housing design for use in the switching cabinet and terminal box No differentiation between crossover cables and : cables required through autocrossing function 24 V DC Ethernet connection: 8 ports on the front side Data transmission rate: 0/00 MBit/s Mounting: carrier rail 35 x 7.5 acc. to EN 50022 SWITCH.8X 2 Signal conditioning instruments Components 265

266 Signal conditioning instruments Components