specification MSE series MSE and MSE+ colorimeter

Similar documents
specification hyperion colorimeter

specification hyperion colorimeter

specification display applications cronus spectrometer & colorimeter

technical note flicker measurement display & lighting measurement

NEW. Display Color Analyzer CA-410. Broad measurement support for today's ever-evolving displays CA-310 successor with major improvements

LCD Colour Analyser, PM 5639/06, handheld LCD Colour Analyser, PM 5639/26, industrial LCD Colour Sensor, PM 5639/94

Measurement of Microdisplays at NPL

OPTICAL POWER METER WITH SMART DETECTOR HEAD

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

DISPLAY COLOR ANALYZER MODEL 7123 MODEL Display Color Analyzer. Key Features:

LED TEST. ATX Hardware GmbH West and Feasa Enterprises Limited a long-standing partnership. SPECIALIST FIXTURE SOLUTIONS

USB Smart Power Sensor

Introduction. Characteristics (Note 1, 2) Parameters Typical Value Units Conditions

LCD MODULE SPECIFICATION

Flash Single Color Datasheet

LMG EG01B - 17"

IMPAC Infrared Thermometers

Display Color Analyzer

LMT X1 - a 12.1" VHB

Description. Kingbright

Description. Kingbright

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

USB Smart Power Sensor

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SURFACE MOUNT DISPLAY. Description. Features. Package Dimensions& Internal Circuit Diagram. Green. Part Number: ACSA02-41SGWA-F01. Super Bright Green

1.0X0.5X0.2mm (0402)SMD CHIP LED LAMP. Features. Descriptions. Package Dimensions


RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Application Note 20D45X Family

1.6X1.25mm BI-COLOR SMD CHIP LED LAMP. Description. Features. Package Dimensions

SC24 Magnetic Field Cancelling System

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

GFT Channel Digital Delay Generator

1.6x0.6mm RIGHT ANGLE SMD CHIP LED LAMP. Features. Description. Package Dimensions. Part Number: APA1606SGC. Super Bright Green

Item Symbol Absolute Maximum Rating Unit Remarks

SURFACE MOUNT DISPLAY. Features. Descriptions. Package Dimensions& Internal Circuit Diagram

LCD Display Wall Narrow Bezel Series

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

SC24 Magnetic Field Cancelling System

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

CBF500 High resolution Streak camera

LadyBug Technologies, LLC LB5908A True-RMS Power Sensor

Transmitter optics with 9x white light LED (optics cover made of glass)

Showcasing Brilliant Photos with Superb High- Definition Clarity

1. General Specification

DPD80 Infrared Datasheet

Displays Open Frame Monitor Model Number: AND-TFT-150Bxx

The QVGA+ Smart Thermal Imaging Camera One of the Most Compact and Lightest High Resolution of InfraRed Camera OEM in the World

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Full-featured CW Microwave Counters for Field, Factory or Lab

Description. Kingbright

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

IMPAC Infrared Thermometers

Description. Kingbright

FLAT DISPLAY TECHNOLOGY

Home Cinema LCD Projector with 4K Enhancement and HDR

Cree XLamp 4550 LEDs BENEFITS

Selected Problems of Display and Projection Color Measurement

OpticalProducts. Illuminating Your Network. Testing the World s Networks

27" 10-point multi-touch interactive display

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

ANDpSi025TD-LED 320 x 240 Pixels TFT LCD Color Monitor

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

PRODUCT SPECIFICATION Date: VESTEL

Microbolometer based infrared cameras PYROVIEW with Fast Ethernet interface

R3267/3273 Spectrum Analyzers

LUT Luminescence scanners: Seeing what no-one else can

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

VPL-DX131. 2,600 lumens XGA Desktop projector. Overview

127mm (5.0INCH) SEVEN SEGMENT DISPLAY. Features. Description. Package Dimensions& Internal Circuit Diagram

R&S ETH Handheld TV Analyzer Portable DVB-T/H signal analysis up to 3.6/8 GHz

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

V DD V DD V CC V GH- V EE

USB Smart Power Sensor

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

DPD80 Visible Datasheet

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

In-process inspection: Inspector technology and concept

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

DS2460Q QAM Analysis Meter

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Displays. AND-TFT-7PA-WV 1440 x 234 Pixels LCD Color Monitor. Features

VPL-DX102. 2,300 lumens XGA Desktop projector. Overview

SPECTRORADIOMETER CS-2000/CS-2000A

Setup Guide. SpectraCal C6 HDR2000 Colorimeter. Rev. 1.2

6.4 Chassis Monitor Model Number: LCM0642xx. SPEC No.: SAS Version: 0.0 Issue Date: April 16, Introduction:

AA3528VR4AS-W2 3.5 x 2.8 mm Surface Mount LED Lamp

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

One of the most compact and lightest QVGA thermal imaging module in the world

DCI Memorandum Regarding Direct View Displays

Magnetic Sensor - Incremental EHP

AZ DISPLAYS, INC. COMPLETE LCD SOLUTIONS SPECIFICATIONS FOR 15.0 OPEN FRAME MONITOR

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

WP36BHD T-1 (3mm) Blinking LED Lamp

XC-77 (EIA), XC-77CE (CCIR)

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

3CCD Color Video Camera BRC-300 BRC-300P. USA Security Systems

Transcription:

specification MSE series colorimeter MSE and MSE+

Contents 1 MSE series: high speed and accurate colorimeter for display measurements... 3 2 Highlights... 3 3 MSE general specifications... 4 4 Typical spectral sensitivity of MSE series... 4 5 MSE series overview... 5 6 MSE 10mm specifications... 6 7 MSE fibre with 5 mm specifications... 7 8 MSE 10mm dimensions... 8 9 MSE fibre dimensions... 9 10 MSE+ 10mm specifications... 10 11 MSE+ 20mm specifications... 11 12 MSE+ fibre with 5mm specifications... 12 13 MSE+ fibre with 20mm specifications... 13 14 MSE+ 10mm dimensions... 14 15 MSE+ 20mm dimensions... 15 16 MSE+ fibre dimensions... 16 2

1 MSE series: high speed and accurate colorimeter for display measurements The MSE Series colorimeter offers a unique combination of high speed and accurate colour measurement capabilities packed in a robust package. The MSE colorimeter is available in 10mm spot size and MSE+ with Wide Dynamic Range in 10mm and 20mm spot size. In addition, M8 fibre connector versions are available of both MSE and MSE+. Thanks to its supreme quality, robustness of both hardware and software and its compact size, the MSE is the ultimate choice for in-line colour measurement applications. Thanks to its build-in mechanical shutter, dark measurements are carried out easily and accurately. The MSE Series are predominantly found inline in display production facilities, their customers or the adjacent R&D departments to handle white point adjustment, uniformity, flicker, reaction time and general colour quality control. 2 Highlights Absolute colour measurement according to human eye (CIE1931) Colour measurement even at low luminance level Colour measurement in XYZ, Yxy, Yu v Other colour spaces available via a supplied colour library Fast colour measurement: 140 measurements/second at luminance level 200 cd/m2 High speed luminance (Y) function: 22.000 luminance samples/second Mechanical shutter for accurate dark level measurement Trigger in and output for inline applications USB and RS232 communication interface USBMTC standard compliant Windows, Linux and MAC OSX compatible Directly supported in Labview, LabWindows, Visual Studio via VISA library 3

3 MSE general specifications Interfaces USB 2.0 RS 232 Trigger in & out USBMTC compliant, SCPI command set, full speed device For PC and embedded purposes, using same command set as USB 5V compliant 4 Typical spectral sensitivity of MSE series Power ratings USB power no shutter used USB power Shutter used Min voltage Typical voltage Max voltage Max current 4.75V 5.00V 5.25V 120mA 4.75V 5.00V 5.25V 225mA Measurement system Photo detector Spectral response Measurement parameters Size (HxWxD) Weight 20mm version Weight 10mm version Weight fibre version Mounting Silicon photo diode using XYZ interference filter Approximates CIE 1931 colour matching functions XYZ, Yxy, Yuv, correlated colour temperature (CCT), dominant wavelength DWL, Flicker, Response time 63 x 24 x 65 mm (without lens system) 255 gram 190 gram 170 gram (excluding accessories) 12 M3 threat holes spread over four sides of MSE Fig 1 Spectral sensitivity of the MSE series colorimeter. 4

5 MSE series overview Admesy currently offers the following MSE versions: MSE 10mm MSE F with fibre and optional lens MSE+ 10mm MSE+ 20mm MSE+ F with fibre and optional lens 5

6 MSE 10mm specifications Measurement system Optical system Acceptance angle 5º (+/- 2.5) Measurement spot size 10mm at 50mm distance 12mm at 100mm distance Measurement speed Luminance 22000samples / second Colour 7ms or higher, depending on luminance level 150cd/m² with DC level light at 50ms PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without averaging Luminance (Y) Chromaticity (x,y) 0.05cd/m² - 3000cd/m² integration time between 1ms and 5s +/-4% of measured value +/-0.001 after calibration Luminance ~ 150cd/m² Y +/-0.3% for Y at 0.1cd/m² ¹ Y +/-0.15% for Y at 1cd/m² ¹ Y +/-0.08% for Y at 5cd/m² ¹ Y +/-0.06% for Y at 150cd/m² ¹ x,y +/-0.003 for Y at 0.1cd/m² ¹ x,y +/-0.001 for Y at 1cd/m² ¹ x,y +/-0.0005 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 1 sample/s for Y at 0.1cd/m² ¹ 2-5 samples/s for Y at 1cd/m² ¹ 5-10 samples/s for Y at 5cd/m² ¹ 10-50 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 10cd/m² or higher +/-2% flicker frequency 30Hz AC/DC 10% sine wave +/-1% Flicker (JEITA method) 10cd/m² or higher +/-2dB flicker frequency 30Hz AC/DC 10% sine wave +/-1dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LED display with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample. If the sample uses PWM, it will take longer. 2 Operating temperature reaches from 0 to 40 degrees. Dark level compensation is optimized for operating in temperatures between 10 and 35 degrees. Other temperature ranges can be calibrated using the mechanical shutter if necessary. 6

7 MSE fibre with 5 mm specifications Measurement system Optical system Acceptance angle 5º (+/- 2.5) Measurement spot size 5.15mm at 30mm distance 5.18mm at 40mm distance 5.36mm at 50mm distance Fibre 800μm fibre with metal jacket Measurement speed Luminance 22000samples / second Colour 7ms or higher, depending on luminance level 150cd/m² with DC level light at 100ms PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without averaging Luminance (Y) 0.1cd/m² - 5000cd/m² integration time between 100μs and5s Chromaticity (x,y) Approximates CIE 1931 colour matching functions +/-4% of measured value +/-0.001 after calibration Y +/-1% for Y at 0.1cd/m² ¹ Y +/-0.5% for Y at 1cd/m² ¹ Y +/-0.1% for Y at 5cd/m² ¹ Y +/-0.08% for Y at 150cd/m² ¹ x,y +/-0.003 for Y at 0.1cd/m² ¹ x,y +/-0.002 for Y at 1cd/m² ¹ x,y +/-0.0008 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 0.2 samples/s for Y at 0.1cd/m² ¹ 1 sample/s for Y at 1cd/m² ¹ 5 samples/s for Y at 5cd/m² ¹ 10-20 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 20cd/m² or higher +/-3% flicker frequency 30Hz AC/DC 10% sine wave +/-2% Flicker (JEITA method) 20cd/m² or higher +/-3dB flicker frequency 30Hz AC/DC 10% sine wave +/-2dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LED display with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample. If the sample uses PWM, it will take longer. 2 Operating temperature reaches from 0 to 40 degrees. Dark level compensation is optimized for operating in temperatures between 10 and 35 degrees. Other temperature ranges can be calibrated using the mechanical shutter if necessary. 7

8 MSE 10mm dimensions 8

9 MSE fibre dimensions 9

10 MSE+ 10mm specifications Measurement system Optical system Acceptance angle 5º (+/- 2.5) Measurement spot size 10mm at 50mm distance 12mm at 100mm distance Measurement speed Luminance 22000samples / second Colour 7ms or higher, depending on luminance level 150cd/m² with DC level light at 50ms PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without averaging Luminance (Y) Chromaticity (x,y) 0.05cd/m² - 30000cd/m² integration time between 1ms and 5s +/-4% of measured value +/-0.001 after calibration Y +/-0.3% for Y at 0.1cd/m² ¹ Y +/-0.15% for Y at 1cd/m² ¹ Y +/-0.08% for Y at 5cd/m² ¹ Y +/-0.06% for Y at 150cd/m² ¹ x,y +/-0.003 for Y at 0.1cd/m² ¹ x,y +/-0.001 for Y at 1cd/m² ¹ x,y +/-0.0005 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 1 sample/s for Y at 0.1cd/m² ¹ 2-5 samples/s for Y at 1cd/m² ¹ 5-10 samples/s for Y at 5cd/m² ¹ 10-50 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 10cd/m² or higher +/-2% flicker frequency 30Hz AC/DC 10% sine wave +/-1% Flicker (JEITA method) 10cd/m² or higher +/-2dB flicker frequency 30Hz AC/DC 10% sine wave +/-1dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LCD screen with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample as well : If the sample uses PWM it will take longer so use the lower rated values. 2 Operating temperature reaches from 0-40 degrees, but dark level compensation works best between 10-35 degrees. Other temperature ranges can be calibrated using the mechanical shutter if necessary. 10

11 MSE+ 20mm specifications Measurement system Optical system Acceptance angle 5º (+/- 2.5) Measurement spot size 18.4mm at 50mm distance 19mm at 75mm distance 20mm at 100mm distance 21.4mm at 150mm distance 23.4mm at 200mm distance Measurement speed Luminance 22000samples / second Colour 1ms or higher, depending on luminance level 150cd/m² with DC level light at 30ms 0.3cd/m² with DC level light at 0.2s PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without averaging Luminance (Y) 0.008cd/m² - 15000cd/m² integration time between 1ms and 5s Chromaticity (x,y) Approximates CIE 1931 colour matching functions +/-4% of measured value +/-0.001 after calibration 11 Y +/-0.3% for Y at 0.1cd/m² ¹ Y +/-0.1% for Y at 1cd/m² ¹ Y +/-0.05% for Y at 5cd/m² ¹ Y +/-0.03% for Y at 150cd/m² ¹ x,y +/-0.002 for Y at 0.1cd/m² ¹ x,y +/-0.001 for Y at 1cd/m² ¹ x,y +/-0.0005 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 1-2 samples/s for Y at 0.1cd/m² ¹ 2-5 samples/s for Y at 1cd/m² ¹ 5-10 samples/s for Y at 5cd/m² ¹ 20-100 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 10cd/m² or higher +/-2% flicker frequency 30Hz AC/DC 10% sine wave +/-1% Flicker (JEITA method) 10cd/m² or higher +/-2dB flicker frequency 30Hz AC/DC 10% sine wave +/-1dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LCD screen with sufficient signal noise ratio, value is based on 2 sigma. Luminance and chromaticity values are based on best performance possible, while measurement speed is determined by Admesy with a signal noise ratio which is still acceptable according Admesy. Sample speed depends on the measured sample as well: If the sample uses PWM it will take longer so use the lower rated values. Detailed measurement data is available upon request 2 Operating temperature reaches from 0-40 degrees, but dark level compensation works best between 10-35 degrees. Other temperature ranges can be calibrated using the mechanical shutter if necessary. General remark: All values are determined as realistic as possible and can slightly differ from device to device.

12 MSE+ fibre with 5mm specifications Measurement system Optical system Acceptance angle 5º (+/- 2.5) Measurement spot size 5.15mm at 30mm distance 5.18mm at 40mm distance (optimal distance) 5.36mm at 50mm distance Fibre 800μm fibre with metal jacket Measurement speed Luminance 22.000samples / second Colour 7ms or higher, depending on luminance level 150cd/m² with DC level light at 100ms PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without Luminance (Y) 0.1cd/m² - 60000cd/m² integration time between 100μs and 5s Chromaticity (x,y) Approximates CIE 1931 colour matching functions +/-4% of measured value +/-0.001 after calibration Y +/-1% for Y at 0.1cd/m² ¹ Y +/-0.5% for Y at 1cd/m² ¹ Y +/-0.1% for Y at 5cd/m² ¹ Y +/-0.08% for Y at 150cd/m² ¹ x,y +/-0.003 for Y at 0.1cd/m² ¹ x,y +/-0.002 for Y at 1cd/m² ¹ x,y +/-0.0008 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 0.2 samples/s for Y at 0.1cd/m² ¹ 1 sample/s for Y at 1cd/m² ¹ 5 samples/s for Y at 5cd/m² ¹ 10-20 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 20cd/m² or higher +/-3% flicker frequency 30Hz AC/DC 10% sine wave +/-2% Flicker (JEITA method) 20cd/m² or higher +/-3dB flicker frequency 30Hz AC/DC 10% sine wave +/-2dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LCD screen with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample as well : If the sample uses PWM it will take longer so use the lower rated values. 2 Operating temperature reaches from 0-40degrees, but dark level compensation works best between 10-35 degrees. 12

13 MSE+ fibre with 20mm specifications Measurement system Optical system Acceptance angle 0.6º (+/- 0.3) Measurement spot size 20.5mm at 50mm distance 21mm at 100mm distance 21.5mm at 150mm distance Fibre 800μm fibre with metal jacket Measurement speed Luminance 22.000samples / second Colour 7ms or higher, depending on luminance level 150cd/m² with DC level light at 100ms PWM requires longer integration (multiple frames) Colorimeter specification Parameter Range Accuracy Repeatability Resolution 15 bit for X, Y and Z >78dB without Luminance (Y) 0.1cd/m² - 60000cd/m² integration time between 100μs and 5s Chromaticity (x,y) Approximates CIE 1931 colour matching functions +/-4% of measured value +0.001 after calibration Y +/-1.5% for Y at 0.1cd/m² ¹ Y +/-0.7% for Y at 1cd/m² ¹ Y +/-0.1% for Y at 5cd/m² ¹ Y +/-0.08% for Y at 150cd/m² ¹ x,y +/-0.004 for Y at 0.1cd/m² ¹ x,y +/-0.003 for Y at 1cd/m² ¹ x,y +/-0.001 for Y at 5cd/m² ¹ x,y +/-0.0002 for Y at 150cd/m² ¹ Measurement speed 0.2 samples/s for Y at 0.1cd/m² ¹ 1 sample/s for Y at 1cd/m² ¹ 5 samples/s for Y at 5cd/m² ¹ 10-20 samples/s for Y at 150cd/m² ¹ CR measurement >200000 +/-5% depending on lowest Y value +/-5% depending on lowest Y value Flicker (contrast method) 20cd/m² or higher +/-3% flicker frequency 30Hz AC/DC 10% sine wave +/-2% Flicker (JEITA method) 20cd/m² or higher +/-3dB flicker frequency 30Hz AC/DC 10% sine wave +/-2dB Operating temperature 10-35ºC ² Shutter lifetime >1000000 Shutter speed 250 300ms depending on temperature and lifetime 1 All measurements are performed 20 times on a CCFL LCD screen with sufficient signal noise ratio, value is based on 2 sigma. Sample speed depends on the measured sample as well : If the sample uses PWM it will take longer so use the lower rated values. 2 Operating temperature reaches from 0-40degrees, but dark level compensation works best between 10-35 degrees. 13

14 MSE+ 10mm dimensions 14

15 MSE+ 20mm dimensions 15

16 MSE+ fibre dimensions 16

Admesy B.V. Sleestraat 3 6014 CA Ittervoort The Netherlands T +31 (0)475 600 232 F +31 (0)475 600 316 www.admesy.com info@admesy.com The material in this document is subject to change. No rights can be derived from the content of this document. All rights reserved. No part of this document may be reproduced, stored in a database or retrieval system, or published in any form or way, electronically, mechanically, by print, photo print, microfilm or any other means without prior written permission from the publisher. Version 1.0.16 04/2018 17