LED Driver Compact dimming

Similar documents
LED control gear Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED Driver Compact fixed output

Emergency lighting units EM powerled

Emergency lighting units EM powerled

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Constant voltage

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Compact dimming

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

LED Driver Linear / area dimming

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

LED Driver Compact dimming

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

OT 100/ /700 P5

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

OPTOTRONIC Intelligent

HID control gear Electronic

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

LED MODULES READYLINE DL

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

DALI TOUCHPANEL BASIC TW. Operating and control unit

Technical Information

Indoor Linear 80W Driver SI-C215280N2KR

Emergency lighting units EM INVERTER

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

Gamma instabus. Technical product information

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

Figure 1: Device components

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

02/11/2015

15 Series - Dimmer

architecture mounting Features Product lighting

Operating instructions

QTi DALI 2X14/24/ DIM

AS09..S 3-pole Contactors - Spring Terminals

Catalogue Ignitors and power switches for HID

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Product Data Sheet 4656 ZW

Series CT7N Bimetallic Overload Relays

TOSHIBA Industrial Magnetron E3328

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Product Data Sheet 8506 VW-691

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Medium-Power-LED-Stripe MPS12-X-X-X-X

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Kuhnke Technical Data. Contact Details

ABB i-bus EIB Universal dimmer 6155 EB for Installation

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Operating Instructions Dimmer for V Incandescent Lamps

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Linear flow controls VFC Linear flow controls with actuator IFC

Type: DILM25 10(24V50HZ) Article No.:

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Luminaire installation box Surface-mounted box Ceiling installation box

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

10 SERIES. Light dependent relays A

INSTALLATION & USER GUIDE

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Linear flow control with actuator IFC

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Dimming actuators GDA-4K KNX GDA-8K KNX

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

3M Sensored Termination (15 kv) QX-T15I-vi1-E

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Benefits. Applications

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Input Control. Input Voltage Range. Model. 2 Vin - 0.2~0.5V % SLD-DimTW V 2 2 Vin - 0.2~0.5V 5. 7 SLD-DimTW

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

AF-300 E11 Adjustable Frequency Drive

Transcription:

Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Product description Dimmable constant current ED Driver (SEV) Independent ED Driver with cable clamps Selectable output current between 180, 250 and 350 ma Max. output power 15 W Up to 81 % efficiency Dimmable via leading edge and trailing edge phase dimmers Dimming range 5 to 0 % (depending on dimmer) ominal life-time up to 50,000 h For luminaires of protection class I and protection class II For luminaires with M and MM as per E 60598, VDE 07 and VDE 0711 Temperature protection as per E 61347-2-13 C5e 5-year guarantee Housing properties Casing: polycarbonate, white Type of protection IP20 Interfaces Terminal blocks: 0 screw terminals Functions Overload protection Short-circuit protection o-load protection Overtemperature protection Burst protection voltage 1 kv Surge protection voltage 1 kv ( to ) Surge protection voltage 2 kv (/ to earth) È Standards, page 3 Wiring diagrams and installation examples, page 3 www.tridonic.com 1

Driver CA 15W 180-350mA flexc PH-C SR ADV ADVACED series Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V Max. input current (at 230 V, 50 Hz, full load) 0.08 A eakage current (at 230 V, 50 Hz, full load) < 500 µa Mains frequency 50 Hz Overvoltage protection 320 V AC, 1 h Max. input power 19 W Typ. power consumption (at 230 V, 50 Hz, full load) 1 17.8 W Min. output power 5 W Max. output power 15 W Typ. efficiency (at 230 V / 50 Hz / full load) 1 81 % λ (at 230 V, 50 Hz, full load) 1 0.95 Output current tolerance 12 ± 7.5 % Max. output current peak 3 500 ma Max. output voltage 60 V THD (at 230 V, 50 Hz, full load) < % Output F current ripple (< 120 Hz) ± 30 % Time to light (at 230 V, 50 Hz, full load) 0.5 s Turn off time (at 230 V, 50 Hz, full load) 0.5 s Hold on time at power failure (output) 0 s Ambient temperature ta (at life-time 50,000 h) 40 C Storage temperature ts -40... +80 C Dimensions x W x H 1.5 x 51 x 29.5 mm 15 6 4 Ordering data Type 1,5 87 tc-point Article number 29,5 tc-point 19,4 51 Packaging, carton Packaging, low volume Packaging, high volume Weight per pc. CA 15W 180-350mA flexc PH-C SR ADV 87500627 20 pc(s). 280 pc(s). 3,360 pc(s). 0.085 kg Specific technical data Type CA 15W 180-350mA flexc PH-C SR ADV 1 Test result at 350 ma. Output current 2 Min. forward voltage Max. forward voltage Max. output power Typ. power consumption (at 230 V, 50 Hz, full load) Typ. current consumption (at 230 V, 50 Hz, full load) Max. casing Ambient temperature temperature ta tc max. I-out select 180 ma 28 V 42 V 7.6 W 9.5 W 45 ma 90 C -20... +50 C +ED / 180mA 250 ma 28 V 42 V.5 W 13.0 W 60 ma 90 C -20... +50 C +ED / 350 ma 28 V 42 V 15.0 W 17.8 W 80 ma 90 C -20... +50 C +ED / 2 Output current is mean value. 3 Test result at 25 C. www.tridonic.com 2

1. Standards E 55015 E 60598-1 E 600-3-2 E 600-3-3 E 61347-1 E 61347-2-13 E 61547 E 62384 To get a proper working strain relief it is recommended that the cable jacket diameter of the side D2 is 2 mm bigger than the diameter of the side D1. (This can vary if the used cable jacket material varies from side D2 to D1 in pinching property). PRESS 1.1 Glow wire test according to E 61347-1 with increased temperature of 850 C passed. D1 D2 2. Thermal details and life-time 2.1 Expected life-time Expected life-time Type Current ta 40 C 50 C 180 ma tc 80 C 90 C ife-time 50,000 h 30,000 h CA 15W 180-350mA flexc PH-C SR ADV The ED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than %. 3. Installation / wiring 3.1 Circuit diagram 220 240 V 50 Hz ED Phase cut dimmer 3.2 Wiring type and cross section 250 ma 350 ma 180mA CA... SR ADV ô tc 80 C 90 C ife-time 50,000 h 30,000 h tc 80 C 90 C ife-time 50,000 h 30,000 h The wiring can be in stranded wires with ferrules or solid. For perfect function of the cage clamp terminals the strip length should be 4 5 mm for the input terminal. The max. torque at the clamping screw (M3) is 0.2 m. Input terminal (D2) max. = 8,0 mm min. = 4,0 mm PRI 0,5 2,5 4 5 Depending on the used flaps of the terminal following cable jacket diameter difference between the side D2 and D1 terminals is recommended: Side D1 Side D2 Housing bottom Cover terminal Difference D2 - D1 With flap Without flap With flap Without flap With flap Without flap x x x 3.5 mm x x x 5.5 mm x x x 3.5 mm x x x 3.5 mm x x x 1.5 mm x x x 1.5 mm x x x 1.5 mm x x x -0.5 mm 3.4 Fixing conditions Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire. Is not suitable for fixing in corner. euchte uminaire The ED module and all contact points within the wiring must be sufficiently insulated against 3 kv surge voltage. 3.5 Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Mains leads should be kept apart from ED Driver and other leads (ideally 5 cm distance) Max. length of output wires is 2 m. Incorrect wiring can damage ED modules. The wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). The current selection has to be installed in the accordance to the requirement of low voltage installation. 3.6 Replace ED module >0 mm >20 mm >50 mm Output terminal (D1) max. = 6,0 mm min. = 2,0 mm 0,5 2,5 4 5 1. Mains off 2. Remove ED module 3. Wait for 20 seconds 4. Connect ED module again Hot plug-in or output switching of EDs is not permitted and may cause a very high current to the EDs. www.tridonic.com 3

3.7 Current select For 180 ma current use this terminals: ED 180mA For 250 ma current use this terminals: 4.2 Power factor vs load 0,99 0,98 Power factor 0,97 0,96 0,95 0,94 0,93 ED 180mA 0,92 67 72 77 82 87 92 97 0 4.3 Input power vs load 18 For 350 ma current use this terminals: ED 180mA 3.8 Mounting of device Input power [W] 16 14 12 8 6 67 72 77 82 87 92 97 0 Max. torque for fixing: 0.5 m/m4 4. Electrical values 4.4 Input current vs load 80 Test at 230 V 50 Hz. 4.1 Efficiency vs load Efficiency [%] 84,0 82,0 80,0 78,0 76,0 74,0 72,0 70,0 67 72 77 82 87 92 97 0 Input current [ma] 70 60 50 40 30 67 72 77 82 87 92 97 0 www.tridonic.com 4

4.5 THD vs load THD without harmonic < 5 ma (0.6 %): THD [%] 16 14 12 8 6 4 2 0 67 72 77 82 87 92 97 0 4.6 Iout vs Vin At full load: At min. load: Iout [%] 0 90 80 70 60 50 40 30 20 0 40 50 60 70 80 90 0 Vin[%] Iout [%] 0 90 80 70 60 50 40 30 20 0 30 40 50 60 70 80 90 0 Vin[%] Remark: Dimming curve based on DIMMER EKO 315GE! 180 ma 250 ma 350 ma 4.7 Maximum loading of automatic circuit breakers Automatic circuit breaker type C C13 C16 C20 B B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 Imax Time CA 15W 180-350mA flexc PH-C SR ADV 75 98 120 150 75 98 120 150 6 A 80 µs 4.8 Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. CA 15W 180-350mA flexc PH-C SR ADV < < 7 < 5 < 4 < 3 < 3 Acc. to 60-3-2. Harmonics < 5 ma or < 0.6 % (whatever is greater) of the input current are not considered for calculation of THD. www.tridonic.com 5

5. Functions 6. Miscellaneous 5.1 Short-circuit behaviour In case of a short circuit on the output side (ED) the ED Driver protects itslef. After elimination of the short-circuit fault the ED Driver will recover automatically. 5.2 o-load operation In no-load operation the output voltage will not exceed the specified max. output voltage. 5.3 Overload protection If the output voltage range is exceeded the ED Driver will protect itself and ED may flicker. After elimination of the overload, the nominal operation is restored automatically. 5.4 Over temperature protection The ED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded the output current is reduced to limit tc at a certain level. 6.1 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or EEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 6.2 Storage conditions Humidity: 5 % up to max. 85 %, not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C The devices have to be within the specified temperature range (ta) before they can be operated. 6.3 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services ife-time declarations are informative and represent no warranty claim. o warranty if device was opened. www.tridonic.com 6