YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

Similar documents
TECHNICAL SPECIFICATION

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Tickets will be sold through our ABC account and all tickets are scannable on entry.

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

THE CLASSIC GRAND 18 JAMAICA STREET GLASGOW G1 4QD

TECHNICAL SPECS SECOND HALL PATRONAAT

TECHNICAL SPECIFICATIONS 2018!

PRODUCTION BIBLE. last update November 2015

SHOWBOX SODO TECHNICAL SPECIFICATIONS

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Hard Rock Cafe Times Square Sound System Advance Sheet

Barbican Concert Hall Sound System Spec

Ed Blackwell Production Manager Mike Weller Head of Music

Dr JOHN GALLAGHER CONCERT CHAMBER

Event Hire Equipment Packages

TECHNICAL SPECIFICATIONS

SOUND TECH RIDER FIDO

Mics, DIs, Stands, and Cables

The Lexington VENUE SPEC. The Lexington Live music venue and whisky lounge. Version 2.5 Updated January 2015

TECHNICAL SPECIFICATIONS Big Venue & Club

Theatre Technical Specifications

Pioneer set monitor 1 1x DJM 900 nexus 2x CDJ 2000 nexus 2x QSC K12 monitor speaker

THEATRE EQUIPMENT DECEMBER 2017

Ex-Hire Used Equipment Price List

TECHNICAL SPECS MAIN HALL PATRONAAT

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Ex-Hire Used Equipment Price List

SOUND + DESIGN THE FUNKTION-ONE SOUND SYSTEM ECO-CONSCIOUS DESIGN AND CONSTRUCTION

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

SPECIAL EVENTS Hollywood Boulevard Los Angeles, CA

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATIONS LEPERCQ

Complete guide Compiled January 2014

STANDARD TIME SCHEDULE JUPILER STAGE doors + showtime HET PARADIJS: 20:30 // 21:00h 14:00 Start local tech crew & backstage manager

Music Hall of Williamsburg

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

Project manager (PM): Pamela Næss Mail: Phone:

Techinal Specifikations

Project manager (PM): Pamela Næss Mail: Phone:

Venue: Schwarzer Bär Hanover. Management: Ferdinand-Wilhelm-Fricke-Weg Hannover

Treefort Music Fest- March Festival Information Main Stage

Technical Specifications for the Rival Theatre 2018

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Setup & Formats. There are 8 sections of 8ft x 4ft Litedeck with 1ft, 2ft and 3ft stage legs to build various forms of staging, podiums and risers.

Information for Incoming Companies

Technical Services and Specification

RIDER 2018 version 1 English

Venue: Schwarzer Bär Hanover. Management: Ferdinand-Wilhelm-Fricke-Weg Hannover

Technical Specification

Access to back stage is off Fletcher St on the eastern side of the building

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

Thank you for thinking of The Fonda Theatre for your private event!

Contact Julianastraat 46, 4301 NC, Zierikzee (NL) +31 (0) (Monday-Friday 13:00-17:00h)

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

BITUSA 2019 General DRESSING ROOMS

UNIVERSITY CONCERT HALL. Technical Specification

AUDIO SPEAKERS / AMPLIFICATION

Technical Information

Contents. 1. Contacts. 2. Directions & Transport Links 2.1. Address 2.2. Local Map & Directions 2.3. Public Transport

INFORMATION FOR VISITING COMPANIES

2018 Building and Production Specifications

Technical Specifications

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

FASO DANCE COMPANY KALAKUTA REPUBLIK

Production Advance Information

SIMON & GARFUNKEL THROUGH THE YEARS TECHNICAL INFORMATION PACK

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

Technical Specification

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

Talent Booking: Ph: Fax: Ph: Fax: Ph: Cell: Ph:

LOAD IN / LOAD OUT CARS / SPLITTER VAN / NIGHTLINER THROUGH MAIN ENTRANCE SITUATED AT AUGUSTE ORTSSTRAAT 20-28, 1000 BRUSSEL.

Main Stage Technical Specs - Hall #2

Ex-Hire Used Equipment Price List

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

The Taal Inc. Rhythm Ensemble Tech Rider

Theatre Technical Specification

TECHNICAL REQUIREMENTS

Contact. Directions. Stichting Studio301 Overtoom HW Amsterdam The Netherlands.

Technical Rider. (last update: Jan. 2016) For more info: Yves Moquin, technical director (514)

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

SAINT ANSELM COLLEGE DANA CENTER

Technical Specification for the Alley Theatre, Strabane

Bloomington Center for the Performing Arts. Technical Specifications

Tech Specs and General Terms & Conditions 2018

111 North 5 th Street Minneapolis, MN 55403

Arcadia Performing Arts Center Technical Specifications and Information

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Rhodes Arts Complex Bishops Stortford. Technical Specifications

Venue Specifications. Telephone: 0221/ Fax: 0221/

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Transcription:

YAAM Berlin Venue Specifications & Technical Rider Effective April 2018 Availability, errors and specifications subject to change without notice! Venue Address: An der Schillingbrücke 3 10243 Berlin Germany Nightliner Parking: Available on demand only!!! Not on sundays! 16A/230V Schuko 16A/400V CEE 32A/400V CEE Public Transport: Communication: Trainstation Berlin Ostbahnhof (S-Bahn, Bus, Long Distance Railway Station two minute walk to Venue W-Lan (Backstage only) No Telephone available Capacity: Indoor: Halle (Main Floor) 750 pax Beachbox 250 pax Mittelfloor 200 pax Gallerie 150 pax Contact Office: YAAM Office Dresdenerstr. 116 10999 Berlin Germany Fon: 0049 (0)30 615 13 54 Fax: 0049 (0)30 66 30 97 23 Open: Monday Friday 10 a.m. - 16 p.m.

Billing Address: Booking: Spreekultur Event und Gastronomie Service GmbH Dresdenerstr. 116 10999 Berlin Germany Alex: alex@yaam.de; Philipp: philipp@yaam.de Technical Director: Sören Schwedler: soeren@yaam.de Halle (Main Floor): Capacity: 750 pax Dimension / Width: 8m Dancefloor: Depth: 20m Hight 4,7m Stage Size: Width: 8m (10m incl. Monitor/ Backline world) Depth: 7m Hight: 1m Clearance height: 3,7m Crashbarriers in front of Stage PA: Sub: 4 x Studt S221S (2x21 ) Mid/High: 12 x RCF TTL55-A (active Line-Array) Amping Sub: Controller Sub: 4 x LAB f6400 1 x EAW MX8750 Monitor: Lines: 10 x Monitor Lines from FOH Wedges: Drumfil: Sidefil left: Sidefil right: Amping: 6 x GAE 4475M 4 x Seeburg Acoustic Line A6 1 x GAE BR118 18 Sub+GAE4475M 1 x GAE 4475M 1 x GAE 4475M 6 x LAB f6400 Monitor-Mix: available on demand: I-Pad monitoring: ask for details! FOH: Mixing Desk: Midas M32 (Digital, 32 channel, 16 Bus, 8 Aux) Stagebox: Midas DL 32/16 Cat 5 Multicore 50m Analogue Multicore: 1 x Stagebox (Ch. 1 48) Midas Venice 320 (Analogue, 32 Channel, 4 Aux, 4 Group Out) Distance to Stage: 10m -18m

DJ-Set: 1 x Pioneer DJM900 SRT (Serato DJ Software) 2 x Pioneer CDJ2000 NXS 2 x Technics 1210 MKII Mic & DI: Risers: 1 x Shure Beta52 1 x Sennheiser e901 1 x Sennheiser e902 4 x Sennheiser e904 3 x Sennheiser e604 2 x Sennheiser e906 3 x Sennheiser e914 2 x Sennheiser e835 2 x Sennheiser e845 6 x Shure SM57 5 x Shure SM58 2 x Shure Beta 58 1 x Shure QLXD24/ Beta58 H51, digitales UHF Wireless-System 1 x Electro Voice RE20 1 x audio technica pro37 2 x Rode NT5 5 x Palmer PAN04 dual passive DI 1 x Palmer PAN03 quad (4-channel) active DI 1 x DIB 100 passive DI 20 x mic stands (small, tall, ) 2 x 16A CEE (three phase alternating current) 1 x 2m x 2m x 0,2m (no wheels) 2 x 2m x 1m x 1,00m/ 0,6m/ 0,4m/ 0,2m (no wheels) Stage Entry: from Backstage (5 Steps, 87cm width) Backstage: Dressing Room 1: behind the Stage (6m x 8m) Dressing Room 2: across the Corridor, with toilette (3m x 3m) No Showers inside the Venue Lighting: Contact: Gordon Gastel (head of lights) gordon@yaam.de Lighting Control Board: 1 x MA Lighting grandma2 onpc Command Wing, Tourpack incl. HP All-in-One Touch PC 1 x MA Lightcommander II 24/6

DMX Universe 1: Stage DMX Universe 2: Floor DMX Universe 3: Split / Free Stage: 2x 63A CEE (three phase alternating current) 1x 32A CEE (three phase alternating current) 1x 16A CEE (three phase alternating current) 6x 6er Bar Par 64, 500W CP 87, NSP 8x LED Compact Par, 18 x 3W RGB 1x Martin Atomic 3000 1x Tourhazer 2E 6x Floorspots Par 64, 500W 8x Arri 650 plus 2x Blinder, 4 channel 2x Trident R10 Movinghead Spot, Wash, Beam 4x Movinghead LED RGBW 8x Sunstrip Matrix (Backwall) Beachbox: Capacity: 250 pax Dimension: Width: 8m Depth: 12m Height: 4,7m Stage Size: Width: 6m Depth: 3m Hight: 0,5m Clearance height: 4,2m PA: Front: Subs: 4 x D&B C4 Subs (18 ) Mid/High: 4 x D&B C4 Tops (12 / 2 ) Amping: Sub: 1 x D&B P1200a High/Mid: 1 x D&B P1200a Controller: 1 x Xilica XP-4080 Monitor: Wedges: 4 x Seeburg Acoustic Line A6 Amping: Controller: 2 x RAM Line1500 1 x Xilica XP-4080 FOH: Mixing Desk 1 x Midas Venice 320/Midas M32 1 x Multicore 32/6 or CAT5-DL

DJ-Set: Risers: Siderack: 1 x Pioneer DJM 900 Nexus 1 x Pioneer DJM 750 2 x Pioneer XDJ 1000 2 x Technics 1210 MKII 1 x SM58 16A three phase alternating current please ask 1 x DeltaLab Effectron Delay 1 x Lexicon MPX110 MultiFX 1 x Lexicon MX400 Dual Stereo FX 1 x Drawmer MX40 Quad Gate 2 x dbx 166XL Compressor 1 x RNC Compressor 3 x BSS fcs 966 Stereo-EQ 1 x Racklight Stage Entry: from behind the stage Backstage: Lighting: Available next to the stage No Showers / No WC Lighting Control Board:ETC Smartfade 1248 Light Control Stage: 1x 32A CEE (three phase alternating current) 1x 16A CEE (three phase alternating current) 2x 6er Bar Par 64, 500W CP 87, NSP 4x Frontlight Par 56, 500W Mittelfloor: Capacity: 200 pax Dimension: Width: 12m Depth: 8m Height: 4,7m Sound: Subs: 6 x Stage Accompany 4518 (18 ) Mid/High: 2 x Tops (2 x 15, 1 x 2 ) Amping: Sub: 2 x QSC EX 2500 High/Mid: 1 x RamAudio R1000 1 x RamAudio R1500 Controller: 1 x Xilica XP-4080 Lighting: Red ambient Lighting. No Lighting Controller.

Beach: DJ-Set: 1 x Pioneer DJM 600 2 x Pioneer CDJ 1000 MK3 Additional Equipment: at the costs of the Promoter the following equipment is available (to prior arrangement ONLY!!!) Please contact: soeren@yaam.de Sound: 1 x Allen & Heath wizard3 12:2 1 x active PA for outdoor events (2 x db Techn. Opera 515DX) Multimedia: 1 x Projector Viewsonic PRO8520WL (5200 Ansi Lumen) 1 x Projector Sanyo PLV-70 or 80 (3000 Ansi Lumen) (please contact us in advance if you need a projector!!!) Please bring your own VGA / HDMI Adapters (especially Mac!) Screen: 2 x 4m x 2m