ADJUSTABLE SPEED DRIVES. nc1 Drive

Similar documents
AF-300 E11 Adjustable Frequency Drive

BOSTON GEAR CONTROLLERS. ACE 10 Series 1/4 through 3 HP Adjustable Frequency AC Motor Controllers MEX (55) QRO (442)

VAT 20 Adjustable Frequency Drive

RYKO Italia s.r.l. V. Casale Morano Po (Al) t f

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Inverters Selection Guide

For applications from 0.25 to 5 HP, the MD60 is a simple AC Microdrive that can be panel mounted as well as wall or machine mounted.

Inverters Selection Guide

Variable Speed Drives OMRON/YASKAWA F7Z - series

Frequency Converter Fv

Frequency Converter EFC 3610, EFC 5610

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SCALE & WEIGHT DISPLAYS

Understanding VFD Allen Bradley Power Flex 4M Variable Frequency Drive. nfi

Operating instructions Electronic preset counter Type series 717

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Basic, cost-effective motor control in one unit: MOVITRAC 07.

SOFT STARTER. We are delivering Real Cost Benefits CD AUTOMATION POWERED BY INNOVATION. Soft Starter Catalog 2018 Release n.

LAUREL ELECTRONICS, INC.

Circuit-Breakers for Motor Protection Series 8523/8

EVC300i. Generator Automatic Voltage Regulator Operation Manual

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Wall-/Pipe-Mount Level Indicator

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

High performance circuit breakers

Frequency Converter EFC 3610, EFC 5610

Typical applications:

Gamma instabus. Technical product information

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Frequency Converter EFC 3610, EFC 5610

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Single Axis Position Controller

Direct PWM. 1000/2000 Series POWERBLOK MODULE

Hybrid Chart Recorder 250 mm (10")

EG4015. Digital Generator Governor Controller User Manual

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

Electronic Pulse Counter Combination device

Series CT7N Bimetallic Overload Relays

SM-10 SAT Level Meter User s Manual

SPECIFICATION NO Model 207 Automatic GTAW Welding System

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Q516 HIGH RES AUDIO DELAY ORDERING OPTIONS SUPPORT OPTIONS MANAGEMENT AND CONTROL HIGH PRECISION AUDIO DELAY FOR MICRO SECOND ACCURACY

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

SPECIFICATION NO NOTE

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

2013, 2014 Hewlett-Packard Development Company, L.P.

EVENT INPUT/OUTPUT MODULE [PUME]

Understanding VFD. Variable Frequency Drive. nfi. nfi

DA E: Series of Narrowband or Wideband Distribution Amplifiers

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

MIKRO POWER FACTOR CORRECTION COMPONENTS

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Chloride EDP Series Three-Phase UPS ( kva): The EDP Series UPS is designed

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

MICROMASTER Encoder Module

X-Band Redundant LNB Systems

Package Contents. LED Protocols Supported. Safety Information. Physical Dimensions

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

SC24 Magnetic Field Cancelling System

Basic Specifications. Driver Model SD12B/15B SD20B SD30B SD30C SD40C SD50C SD75C

Hour Meters / Timers, electronic

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

DCP100 Digital Control Programmer Specifications

Kuhnke Technical Data. Contact Details

SC24 Magnetic Field Cancelling System

Process Transmitter RMA 422

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

FRQM-2 Frequency Counter & RF Multimeter

1215L 12 LCD Desktop Touchmonitor

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

ScopeMeter 190 Series Specifications

DA : Series of Narrowband or Wideband Distribution Amplifiers

Bulletin 190 IEC Modular Starter System

SNG-2150C User s Guide

EVD-L04/100A1-960, EVD-L08/200A1-960 and. EVD-L16/400A1-960 DVRs. Quick Operation Guide

Micro-DCI 53ML5100 Manual Loader

CLOCKAUDIO. MR88 Automatic Microphone Mixer. Version 4.2

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Instruction Manual Model # Block Upconverter

Natural-sounding telephone audio... Hybrids

HITACHI. Instruction Manual VL-21A

Digital Video Recorder

MS2540 Current Loop Receiver with RS485 Communication

Product Catalog Frequency Converters

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

02/11/2015

R-1580A Microwave Downconverter. Product Brochure

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Electronic Lineshaft With Alignment F7 Drive Software Technical Manual

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

SonoruS Audio. ATR10 Analog Tape Reproducer. Operating Manual

Hitachi Kokusai Electric Comark LLC

Variable speed drives Altivar 61

Transcription:

ADJUSTABLE SPEED DRIVES nc1 Drive

Ultra-Compact Sub-Micro Drive The nc1 is a sub-micro, or nano-sized drive with a full range of features to meet the needs of nearly any user. The nc1 is designed to be a simple drop in replacement for a starter on an existing project or as a new installation. Either way, the nc1 s small size and full featured design make it a perfect choice for your application. An Easy Choice The nc1 drive comes with either single-phase or three-phase input with input voltage ratings as low as 120 V. This makes it an excellent choice for small OEM applications. The single-phase input means that the nc1 can be used in applications that were previously too cost-prohibitive to install a three-phase drive. All nc1 s have a threephase 230 V output. Models and Applicable Motors Simple to Install The nc1 is designed to be a drop-in replacement for a starter. The terminal arrangements for input and output power are even set up like a starter. Side-byside mounting and the unit s vertical construction allow for a smaller footprint. The nc1 provides better control of your application, more protection for your motor, and more room in your cabinet.

Easy-to-Use Easy To Program The nc1 uses a simple, straightforward programming menu for quick and easy setup of the drive. There are no complicated sub menus or hidden parameters. By using the built-in programming wizards, the nc1 can be programmed for simple operations with the push of a button. Available Windows programming software makes it a snap to set up the drive. User-Friendly Operation The nc1 comes ready to run. Simply mount the drive, run your power connections and you are ready for operation. Many operations require no programming whatsoever. The user-friendly interface is designed to set the speed and start/stop functions of the unit easily. The drive will also operate from nearly any standard industrial control inputs. Array of Communications In today s fast-paced manufacturing world, coordinated systems require communications from drive-to-drive and drive-to-system. A built-in port and a variety of option cards give you versatility in communication selection. Built-In RS232/RS485 Port Communication Protocol Options - Ethernet TCP/IP - Ethernet IP - DeviceNet - Modbus RTU - Modbus Plus - Johnson Controls Metasys N2 - Profibus DP

nc1 Drive Full-Scale Display Displays the operating frequency, parameter information, a monitored item, the cause of a failure, and so on. Input Terminals CHARGE Lamp Indicates that high voltage is still present within the inverter. Do not open the cover while this is lit. PROGRAM Lamp Lights when the inverter is in parameter setting mode. This lamp blinks when the parameter AUH or Gr.U is selected. MONITOR Key Displays operating frequencies, parameter, and error messages. UP Key Pressing the up key when lamp is on allows the operating frequency to be seen. RUN Lamp Lights when an ON command is issued but no frequency signal is sent out. It blinks when operation is started. DOWN Key Pressing the down key when lamp is on allows the operating frequency to be seen. STOP Key Pressing of the STOP key while the RUN key lamp is on will cause a slowdown-stop. Built-In Potentionmenter Output Terminals ENTER Key

Standard Specifications nc1 ASD Standard Specifications Model Range 1001P-1007 P 2002P-2022P 2001PL-2022PL 2002P-2022P Input Voltage Rating 120 V/Single Phase 230 V/Single Phase 230 V/Three Phase 230 V/Single Phase with RFI / EMI Filter KW Range 0.1 to 0.75 KW 0.2 to 2.2 KW 0.1 to 2.2 KW 0.2 to 2.2 KW HP Range 1/8 to 1 HP 1/4 to 3 HP 1/8 to 3 HP 1/4 to 3 HP Overload Rating 150% for 60 Seconds Input Voltage Tolerance +10%, -15% +10%, -15% +10%, -15% +10%, -15% Input Frequency Rating 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Input Frequency Tolerance ± 5% ±5% ±5% ±5% Output Voltage Rating 230 V, Three Phase Color Munsel 5Y8 / 0.5 Control System Sinusoidal PWM Control Output Voltage Range Adjustable within a Range of 100 to 120% of Corrected Supply Voltage (200 V), Nonadjustable to any Voltage Higher than the Input Voltage Output Frequency Range 0.5 to 200 Hz, Default Setting: 0.5 to 80 Hz, Max Frequency: 30 to 200 Hz Minimum Frequency Step 0.1 Hz: Operation Panel Setting, 0.2 Hz: Analog Input (when the Max Frequency is 100 Hz) Frequency Accuracy Digital Setting: within ±0.5% of the Max Frequency (-10 to +50 C) Analog Setting: within ±1.0% of the Max Frequency (25 C ± 10 C ) V/f Characteristics V/f, Slip Frequency Compensation, Base Frequency, Base Frequency Voltage and Torque Boost (Adjustable Amount) Internal Pot on the Front Panel, External Frequency Signal (Connectable to a Volume with a Rated Impedance of 3 to 10 kω), Frequency Setting Signal VI Terminal (Input Impedance: 42 kω (Voltage: 0 to 10 Vdc) or 250 Ω (Current: 4 to 20 madc)). Frequency can be Set Arbitrarily Using a Two Point Setting Startup & Jump Frequency Adjustable within a Range of 0.5 to 10 Hz; Up to 1 Frequency can be Adjusted Together with its Widths PWM Carrier Frequency Selectable from among 2, 4, 8, 12, and 16 khz (Standard Default Setting: 12 khz or 4 khz for Models with a Built-In EMI Noise Filter) Accel/Decel Time Two Selectable Accel/Decel Times Adjustable from 0.1 to 3000 seconds Retry Operation Selectable Number of Retries (Maximum 10 Times); If Protection Function is activated, Retry Function restarts after a main circuit check. Electric Control Charging of Capacitor (Deceleration Time can be Shortened by Activating Forced Shortened Deceleration Mode) Dynamic Braking Braking Start Frequency: 0 to Max Frequency; Braking Rate: 0 to 100%; Braking Time: 0 to 20 seconds Input Terminal Functions Forward/Reverse Run Input Signal, Jog Run Input Signal, Standby Signal, Preset-Speed Operation Input Signal, Reset Input Signal, etc. Output Terminal Functions Frequency Lower Limit Output Signal, Frequency Upper Limit Output Signal, Low-Speed Detection Output Signal, Specified Speed Attainment Output Signal, etc., Open Collector, RY Output Failure Detection Signal 1 Form C Contact, Rated: 250 Vac, 2A, cosø = 0.4 FM/AM Output PWM Output: (1 madc Full-Scale DC Ammeter or 7.5 Vdc Full-Scale DC Ammeter/Rectifier-Type AC Voltmeter, 225% Current Max 1 madc, 7.5 Vdc Full-Scale) Stall Prevention, Current Limitation, Overcurrent, Output Short Circuit, Overvoltage, Overvoltage Limitation, Undervoltage, Ground Fault, Protective Function Power Supply Phase Failure, Output Phase Failure Overload Protection by Electronic Thermal Function, Armature Overload at Startup, Load-Side Overtorque at Startup, Overheating Prevention, Detection of Analog Signal Break Momentary Power Failure Protection Auto-Restart Control after Momentary Power Failure Electronic Thermal Characteristics Switching between Standard Motor/Constant- Torque VF Motor, Overload Trip, Overload Stall Selection Frequency: Inverter Output Frequency Alarm: Stall Alarm C, Overvoltage Alarm P, Overload Alarm L, Overheat Alarm H. 4-Digit, 7-Segment LED Status: Inverter Status (Frequency, Cause of Activation of Protective Function, Input / Output Voltage, Output Current, etc.) and Parameter Settings Free-Unit Display: Arbitrary Unit (e.g. Rotating Speed) Corresponding to Output Frequency Indicator Lamps Indicate Inverter Status by Lighting, such as RUN Lamp and PROGRAM Lamp Use Environments Indoor-Altitude: 1000 Meters (Maximum), not Exposed to Direct Sunlight, Corrosive Gas, Explosive Gas or Vibration (Less than 5.9 m 2 ) (10 to 55 Hz) Ambient Temperature -10 to +50 C Storage Temperature -20 to +65 C Relative Humidity 20 to 93% Non-Condensing Model FLA & Approximate Dimensions (Inches) & Weight (Lbs) VOLTAGE HP MODEL NUMBER FLA HEIGHT WIDTH DEPTH WEIGHT 110 V Single Phase 230 V Single Phase 230 V Three Phase 230 V Single Phase Built-in RFI / EMI Filter 0.12 VFNC1S-1001P 0.7 5.6 2.8 3.9 2.2 0.25 VFNC1S-1002P 1.4 5.6 2.8 3.9 2.2 0.5 VFNC1S-1004P 2.4 5.6 2.8 3.9 2.2 1.0 VFNC1S-1007P 4.0 5.6 4.6 4.9 2.2 0.25 VFNC1S-2002P 1.4 5.6 2.8 3.9 2.2 0.5 VFNC1S-2004P 2.4 5.6 2.8 4.9 2.2 1.0 VFNC1S-2007P 4.0 5.6 2.8 5.4 2.2 2.0 VFNC1S-2015P 7.5 5.6 4.6 6.1 3.3 3.0 VFNC1S-2022P 10 5.6 4.6 6.1 3.3 0.12 VFNC1-2001P 0.7 5.6 2.8 3.9 2.2 0.25 VFNC1-2002P 1.4 5.6 2.8 3.9 2.2 0.5 VFNC1-2004P 2.4 5.6 2.8 4.9 2.2 1.0 VFNC1-2007P 4.0 5.6 2.8 5.4 2.2 2.0 VFNC1-2015P 7.5 5.6 4.6 6.1 3.3 3.0 VFNC1-2022P 10 5.6 4.6 6.1 3.3 0.25 VFNC1S-2002PL 1.2 5.6 2.8 3.9 2.2 0.5 VFNC1S-2004PL 2.3 5.6 2.8 4.9 2.2 1.0 VFNC1S-2007PL 4.0 5.6 2.8 5.4 2.2 2.0 VFNC1S-2015PL 7.5 5.6 4.6 6.1 3.3 3.0 VFNC1S-2022PL 10.7 5.6 4.6 6.1 3.3

Medium Voltage Motor North America Headquarters & Manufacturing Facilities (Houston, TX) G7 Drive TOSHIBA Quality by Design Toshiba's culture and history are strongly rooted in quality. Our designs are technologically innovative, and our products are manufactured from start to end using only the highest quality domestic and foreign parts. Product Warranty Toshiba offers a comprehensive warranty program on its full line of industrial products. Consult your salesperson or the factory for specific information. Need to Know More? Be sure to visit our website located at www.toshiba.com/ind for the latest information on Toshiba products and services. Customer Support Services Toshiba offers 24-hour service nationwide. For assistance of any type call: 1-800-231-1412. ADJUSTABLE SPEED DRIVES MOTORS CONTROLS UPS INSTRUMENTATION PLC Available Through: INDUSTRIAL DIVISION 13131 West Little York Road, Houston, Texas 77041 Tel 713/466-0277 Fax 713/466-8773 US 800/231-1412 Canada 800/872-2192 Mexico 01/800/527-1204 www.toshiba.com/ind Copyright 8/2007 *NC1brocct070815*