3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

Similar documents
3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Distribution Box (DDB)

3 SLiC Aerial Closure with Rubber End Seal

Cabinet Tools and Accessories Ordering Guide

3M Coupling Tray FDTC-10S-COUPLINGTRAY

SLiC Fiber Aerial Closure 533 and 733

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Better Buried Closures

4320 SS-25 Self-Strip Terminating Block

3M Locator Plate N

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

SLiC Fiber Aerial Closure System

18mm ECAM Cable Entry Port

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Better Buried Compound Compression Closure System

3M Slim Lock Closures

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Cold Shrink Foldback Splice Jacket Kit

3M No Polish Jacketed SC/APC Connector

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M 8900 Single-mode SC Crimplok Connector

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

Solutions for Electronic Specialty Markets (ESM)

3M New Construction Cross-Connect Cabinets. The. Commitment. Your Copper Requires

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Sensored Termination (15 kv) QX-T15I-vi1-E

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

27mm ECAM Double Cable Entry Port

3M Fiber Closures BPEO

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

Instructions. Cable with Armor F CAUTION. October Rev A

Instruction Guide February 2017

3M MetPak 2-FB Header

Scotch Heavy Duty Vinyl Electrical Tape 22

3M No Polish Jacketed SC/APC Connector

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

3M We are Projectors! When the show must go on, 3M makes it easy:

Built tough for long-term connections

Built tough for long-term connections

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Fiber Optic Closure System LL

3M Cold Shrink Splice Kit QS-III 5515A

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

3M Fiber Optic Wall Mount Enclosure 8430 Series

Installation Instructions

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

Scotchlok Connectors and Tools

3M Cold Shrink Splice Kit QS-III 5416A

Dynatel Advanced Cable Locator 2250

2178-L/S Series Fiber Optic Splice Case with Gasket

3M Pressurized Closure System 2-Type 505

2178 L/S Series Fiber Optic Splice Cases and Accessories

K & B Flame Retardant Building Riser Closures

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

3M Super 23 Electrical Tape

3M Cold Shrink Rubber Splicing Kit 5552

Better dispensing, better results.

3M Mini D Ribbon (MDR) Cable Assembly

3M One Pass Mini Fiber Pathway

FOSC 450 C6 and D6 Closures

Cold Shrink Silicone Rubber Termination QT-II

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

HSK Mine and Portable Cable Splice

Medium Box for Cable Termination

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

IP-LINX. Installation Guide

Quick Release Roof-Mount Kit MB700

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

AtlonA 4x4 HDMI over CAT5 Matrix Switcher with IR Control AT-HD44M-SR. User Manual

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

Instant 802.3af Gigabit Outdoor PoE Converter. Model: INS-3AF-O-G. Quick Start Guide

QCA9-33 Active Combiner

Installation instructions Ex frames

IP-LINX Fiber :: X-XXXX

Component Video + Analog/Digital Audio Wall Plate (6-RCA) AT80COMP7

Size Matters: When it comes to FTTH deployment in MDUs, less is more. By Linnea Wilkes, Business Development Manager Business White Paper

Electrical Markets 3M ScotchCode Wire Marking and Identification System. Quality. Marking. For Most Projects

Instructions for Use of Overlap Seam Repair Kit:

Installation instructions Roxtec CM PE systems

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

User Manual. AtlonA COMPOSITE VIDEO (BNC) + STEREO AUDIO TO HDMI VIDEO FORMAT CONVERTER AND SCALER AT-HD120

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Atlona HDBaseT-Lite Transmitter over Single CAT5e/6/7

Transcription:

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX) In-cabinet and Outdoor AC Power Junction Box (JBOX) for 3M Cross-Connect Cabinets with DSLAM apparatus cases installed Instructions November 2015 78-0015-2735-3-A

2 November 2015 78-0015-2735-3-A Contents 1.0 General 2.0 Accessories - Ordering Information 3.0 Cabinet Overall Description 4.0 Internal 3M Junction Box (JBOX) for AC power 5.0 Outdoor-rated 3M Junction Box (JBOX) installation 1.0 General 1.1 These instructions provide the information necessary for the installation of an internally mounted AC power junction box in 3M Cross-Connect Cabinets 4220SVB, 4220SVC or 4220SVE. These cabinets are designed to mount an indoor rated AC power junction box on the interior side wall. This box is for the connection of the incoming commercial power to the DSLAM AC power supply cord. The outdoor-rated power junction box is to be mounted on an outside structure, not on the 3M Cross-Connect Cabinets, per your local company practice. Note: Follow all of your company safety requirements and specifications with regard to AC power in addition to your local power company and municipal rules and regulations. 1.2 Tools required for installation: a. UAE socket set b. Standard hand tools 1.3 Accessories - general a. Stake mount kit b. Pole/Post/Wall mount kit c. Rear cable entry skirt kit d. Front or rear stabilizer kit e. Rear cable entry skirt with stabilizer kit f. Top cable entry port kit g. Bottom cable entry port kit h. Internal cable sealing port kit i. 3M Quick-Connect System (QCS) 2810 300 maximum pair empty or loaded frame j. QCS 2810 600 maximum pair loaded frame k. QCS 2810 50 pair harness kits l. Fiber box m. AC power box n. Cable/pair count labels 1.4 Additional materials that may needed for total DSLAM point installation: a. Port sealing materials b. Splicing connectors c. 3M Scotchlok Shield Bond Connector 4460D

78-0015-2735-3-A November 2015 3 2.0 Accessories Ordering Information for 3M Cross-Connect Cabinets 4220SVB Cabinet only 80611486061 4220SVBSK-A KIT SKIRT 80611486079 4220SVBSSK-A KIT STABILIZERS/SKIRT 80611486251 4220SVB/VB-PMK-GRADE PEDCAB BTM ENTRY GRADE/POLE MT 80611486293 4220SVB-TCPK KIT TOP CAP PORT 80611486301 4220SVB-BCPK KIT BOTTOM CAP PORT 80611486319 4220SVBS-A KIT STABILIZERS 80611498140 4220SVB-QCS/A CABINET EMPTY ALMOND 80611486244 4297-4220SVB/VB-BP KIT BREAD PAN I.D. 4"X11" 80611498132 QCS3N/300-000/A FRAME EMPTY 4220SVC Cabinet only 80611486400 4220SVC-A KIT STABILIZERS 80611486426 4220SVC-TCPK KIT TOP ENTRY PORT 80611486434 4220SVC-BCPK KIT BTM ENTRY PORT 80611486392 4297-4220SVC/VC-BP KIT BREAD PAN I.D. 4"X11" WIDE FLANGE 80611498173 4220SVCSSK-A KIT STABILIZERS/SKIRT 80611498223 4220SVCSK-A KIT SKIRT ALMOND 80611498215 4220SVC-QCS/A CABINET EMPTY ALMOND 80611481310 QCS6-QCSHC/600-000/-A FRAME EMPTY 4220SVE Cabinet only 80611498231 4220SVESk-A KIT SKIRT ALMOND 80611498157 4220SVE-QCS/A CABINET EMPTY ALMOND All 4220SVB, 4220SVC and 4220SVE Cabinets 80611486202 4220SV/DSLAM/MB-AD-A KIT BKT OSP DSLAM MT SVB, SVC, SVE 80611486228 4220SV/DSLAM/MB-CA-A KIT BKT OSP DSLAM MT SVB, SVC, SVE 80611486095 PBO-S1-2SCA-CL KIT FIBER TERMINAL 80611498165 PBPOC-2-12-CL KIT FIBER TERMINAL 80611498199 MCFK8OD KIT MIDSPAN BOX/2 PIGTAIL, ADAPT, SBOND, GSTRAP 80611498207 4056-SVS-A STAKE MT KIT BULK ALMOND 80611498249 JBOXI INTERNAL TO CABINET 80611498256 JBOXO OUTDOOR 80611498231 4220SVESK-A KIT SKIRT ALMOND 80611486236 4220SVES-A KIT STABILIZERS 80611498181 4220SVESSK-A KIT STABILIZERS/SKIRT

4 November 2015 78-0015-2735-3-A 3.0 Cabinet Overall Description for 3M Cross-Connect Cabinets Cabinet Product Max Pair Count QCS 2810 Max # of Frames QCS 2810 Frame Number Dimensions Height/Width/Depth (inches) Single Sided Low Profile 4220SVB 300 1 QCS3 44 7/8 x 12 3/8 x 10 1/8 X X 4220SVC 600 1 QCS6 44 7/8 x 18 x 10 1/8 X X 4220SVE 1200 2 QCS6 44 7/8 x 33 x 18 X X 4.0 Internal 3M Junction Box (JBOX) for AC power 80611498249 JBOXI INTERNAL TO CABINET Note: A ground strap may be placed between the enclosure buss bar and the bottom left mounting post. This minimum #10 AWG ground strap should include ¼" AMP ring terminal on each end. Consult your local power company and your local company practice to determine correct material and installation per your local practice. Note: The electrician will need to provide retention clamps for all power cables entering the power junction box both inside the cabinet and the remote mounted box. 4220SVB 4220SVC 4220SVE Power junction box mounting positions 1 1 2

78-0015-2735-3-A November 2015 5 4.1 Internal mounting of indoor 3M Junction Box (JBOX) a. Read and follow all manufacturer instructions prior to installation. b. Locate the four interior mounting studs on top left hand side panel. c. Remove the nuts. d. Place the box with the non-painted mounting hole to the bottom left. e. Install the JBOX on the four interior mounting studs and reinstall nuts and tighten. f. Route the DSLAM AC power cord from the cabinet base along the back wall of the cabinet. g. Perform make ready work per your local company practice for the DSLAM AC power cord and commercial power service. 5.0 Outdoor-rated 3M Junction Box for AC power 80611498256 JBOXO OUTDOOR Install per your local company practice

3M and Scotchlok are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any direct, indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 Phone 1-800-426-8688 Web www.3m.com/telecom Please recycle. Printed in USA 3M 2015. All rights reserved. 78-0015-2735-3-A