with EcoSystem Please Read

Similar documents
DALI with KNX Control Unit

with EcoSystem Control Unit Installation and Operation Guide Please Read

Control Unit. Installation and Operation Guide. Please Read

Control Unit. Installation and Operation Guide. Please Read

Lighting Zone Controller. Specifications

DIN Power Module - Phase Adaptive

Softswitch128TM. SwitchingSystem. Setup and Maintenance Guide

RA-RS232, RB-RS232. Setup and Installation Guide Addendum For RadioRA RS232 Interface

LCP128TM Dimming and Switching

PowPak Dimming Module with 0 10 V Control

PowPak Dimming Module with 0 10 V- Control

EcoSystem with Shades Energi Savr Node. Installation Instructions QSN-2ECO-PS120

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

Caseta Wireless 3-Way/Single-Pole RF Dimmer For Led, Elv, MLV, or Halogen Lights In White

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

QS DMX Control Interface

By CHANNEL VISION. Flush Mount Amplifier A0350

MRF2600MLA 600W 120V RF Wireless Dimmer LT Almond

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Maestro Wireless Dimmers and Switches

VNS2200 Amplifier & Controller Installation Guide

USER MANUAL Full HD Widescreen LED Monitor L215ADS

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

USER MANUAL Full HD Widescreen LED Monitor L215IPS

2.0 Wall Mount TV Soundbar Instruction Manual

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

Application Note #247 Revision E November 2014

Application Note #428 Revision A April 2012 Wired seetouchr QS Wallstation: Advanced Programming Mode

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

4 Wiring Brochure Wiring and installation of specific control

2.4GHz Digital Wireless Video Door Phone User Manual

SceneStyle2 User Guide

Switching Power Module

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

USER MANUAL Full HD Widescreen LED Monitor L236VA

PLL2210MW LED Monitor

Golf ball tracker. Instruction manual

Aspect 2 Circuit Digital Scene Control

Wireless Sound Bar *MFL * SIMPLE MANUAL

Spacer System dimmers and switches

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

HD Digital MPEG2 Encoder / QAM Modulator

INSTALLATION AND OPERATION MANUAL

MODEL HA07 - MASTER CONTROLLER INSTRUCTIONS

PL2410W LCD Monitor USER'S GUIDE.

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

DDW36C Advanced Wireless Gateway - Safety and Installation Product Insert. Federal Communications Commission (FCC) Interference Statement

Nova T* Controls. Nova T*

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

PREPROGRAMMED FOR YOUR SET-TOP BOX

IPSTB1200 /IPC3200 Media Client User guide

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

SMART Hi-Fi AUDIO *MFL * SJ8 SIMPLE MANUAL. Wireless Multi-room Sound Bar

RadioRA 2 Enhancement and Interface, 120V main repeater with MHz to MHz or MHz to MHz

Cyclo Series. user manual. MartinArchitectural

OWNERS MANUAL. Revision /29/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

3000 Series. The World s Finest Multi-Scene Preset Lighting Control. Product Family Features. Specification Features. System Features.

WaveLinx Mobile. WaveLinx Mobile Quick Start Guide. Programming Steps

QUICK START GUIDE. IP Camera & NVR Bundle ENGLISH

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

PQ Labs Multi-Touch Screen G 2 Overlay

Evolution Digital HD Set-Top Box Important Safety Instructions

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Figure 1: Device components

PLL1920M LED LCD Monitor

HD Digital Set-Top Box Quick Start Guide

PXL2760MW LED LCD Monitor

HD Digital MPEG2 Encoder / QAM Modulator

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

User s Guide. Dimensions 4000 Series Control System. Topics at a Glance

Welcome to NEED HELP? DIRECTV offers the best entertainment experience. Use this guide to make the most of it LKR FCC ID : ORS

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT

Wireless SMART1+ Remote Operating Instructions. P/N Rev. A

INSTALLATION INSTRUCTIONS FOR

1-In / 2-Out. HDMI Splitter User s Guide

DCL9AW. User Manual. English

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

Special Order To order, add color/finish suffix code to model number. Example: NT-600-BB Metal Finishes. Special Metal Finishes

22" Touchscreen LED Monitor USER'S GUIDE

PLL2710W LED LCD Monitor

DTA Easy Setup Guide. Installation Operation Troubleshooting

Wireless Sound Bar *MFL * SIMPLE MANUAL

USER S MANUAL CCTV LED MONITOR MODEL: ADE-117N1 ADE-119N1 ADE-118W1 ADE-121W1 ADE-124W Atherton Electronics Corp. All rights reserved.

Inside the Box. Touchscreen LCD 1 WAN 2 LAN. Reset Button. Power Connector. Stylus

Power Injector 1520 Series

Installation Manual SaVi Note Underwater LED Light

MiraScreen Wire Powered by EZCast

IRISPen Air 7. Quick User Guide. (ios - ipad)

Always there to help you. Register your product and get support at SRP3013. Question? Contact Philips.

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

15 Series - Dimmer

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

VGA Extender over Cat 6 with Audio Support. Model Extend both video and audio up to 300 meters

ZvBox 150. HD video distribution over COAX Get Going Guide

Programming Guide and User Manual INS # Model # CKM. ControlKeeper M

Always there to help you. Register your product and get support at SRP5018. Question? Contact Philips.

Transcription:

with EcoSystem Please ead Installation and Operation Guide The GAFIK Eye QS with EcoSystem control unit allows for control of both lights and shades, without interfaces, using a single control unit. Features include push scene recall, info screen that displays energy savings and status, I receiver, astronomic timeclock, contact closure input, and engravable backlit s that are easy to find and operate. The built-in EcoSystem bus link can control up to 64 EcoSystem devices. LUTON Model Numbers: QSGJ-6E, QSGJ-8E, QSGJ-E QSG-6E, QSG-8E, QSG-E 120 V 50/60 Hz 220-240 V 50/60 Hz Unit Capacity (watts) 2000 W 3000 W MLV 2000 VA / 00 W 3000 VA / 2400 W Zone Capacity (watts) 25 800 W 40 1200 W MLV 25 800 VA / 25 600 W 40 1200 VA / 40 960 W See page 7 for EcoSystem bus ratings; see page 9 for PELV (Class 2: USA) ratings.

Contents Features and Functions of the GAFIK Eye QS with EcoSystem.......... 3 Wiring the GAFIK Eye QS with EcoSystem Overview of Line Voltage/Mains and EcoSystem Wiring..................... 4 Line Voltage Wiring Details.................. 5 EcoSystem Bus Wiring Details............. 7 Overview of PELV (Class 2: USA) Wiring....... 8 QS Link Control Wiring Details............... 9 QS Link Control Wiring and Terminal Connection Example......... 10 Powering More Than 3 Wallstations......... 11 Completing Installation of the GAFIK Eye QS with EcoSystem........ 12 General Functionality................... 13 Pre-Programmed Button Functionality..... 14 Zone Button Operation Zone LED Displays for % of Lighting Levels... 15 Programming Mode Entering and Exiting Programming Mode..... Navigating Menus in Programming Mode..... Wireless Mode......................... 17 FCC Information......................... 17 Zone Setup Assign Load Types....................... 18 Assign Non-Dim Load Type................ 18 Setting Load Types....................... 19 Set High End or Low End Trim.............. 20 Set Minimum Level (optional)............... 20 Label a Zone (optional).................... 21 Application Suggestions and Differences between GAFIK Eye QS with EcoSystem and Standard EcoSystem Bus Supply... 22 EcoSystem Setup Overview Build System............................ 23 EcoSystem Setup Assign/Unassign an EcoSystem Device to a Zone (Zone setup)................... 24 Address EcoSystem Devices............... 25 Contact Closure Input (CCI) Mode Setup... 26 Associating Wireless Occupancy Sensors and GAFIK Eye QS Wireless Control Units......................... 27 Occupancy Sensor Setup Mode Assignment........................ 28 Scene Mode............................ 29 Zone Mode............................. 30 Label an Occupancy Sensor (optional)....... 31 Configure Occupancy Sensor Settings....... 32 Associating Wireless Daylight Sensors and GAFIK Eye QS Wireless Control Units......................... 33 Daylight Sensor Setup Mode Assignment........................ 34 Zone Mode............................. 35 Group Mode............................ 36 Label a Daylight Sensor (optional)........... 38 Scene Setup Set Zone Levels, Fade ates, and Shade Group Actions................ 39 Label a Scene (optional)................... 40 Enable/Disable Daylighting per Scene........ 40 Set Save Mode Save Modes............................. 41 Quick Scene Programming Save by Mode........................ 42 Operation Set Time and Date....................... 43 Set Location............................ 44 Set Daylight Saving Time.................. 44 Add an Event............................ 45 Delete an Event.......................... 46 View an Event........................... 46 Set a Holiday............................ 47 View a Holiday........................... 47 Delete a Holiday......................... 47 Copy a Schedule......................... 48 Delete a Schedule........................ 48 Afterhours Mode......................... 49 Set Up Afterhours Mode................... 50 End Afterhours Mode..................... 50 Associating PICOTM Wireless Controls and GAFIK Eye QS Wireless Control Units To use the PICO Wireless Control as a Scene Controller........................ 51 To use the PICO Wireless Control as a Zone Controller......................... 52 Associating Sivoia QS Shades/Drapes and GAFIK Eye QS Control Units...... 53 Adjusting Shade Settings Setting Limits............................ 54 Preset Adjustment: Simple Method.......... 55 Preset Adjustment: Advanced Method....... 55 Name a Group of Shades.................. 56 Associating Multiple GAFIK Eye QS Control Units......................... 57 Diagnostics and Special Settings Enable/Disable................. 58 Enable/Disable I eceiver................ 58 Enable/Disable Backlighting................ 58 Diagnostics............................. 58 Activate System Accessories............. 59 Faceplate emoval..................... 59 Language Selection.................... 59 Troubleshooting....................... 60 Troubleshooting: Wireless Functions....... 61 Troubleshooting: Shade Functions........ 62 Troubleshooting: EcoSystem Functions... 63 Warranty............................. 64 Contact Information.................... 64 GAFIK Eye QS with EcoSystem Installation and Operation Guide

Features and Functions of the GAFIK Eye QS with EcoSystem Hinged faceplate Page Switches between displaying zones 1 to 8 and 9 to on -zone unit Zone numbers Zone raise/lower s Zone LEDs display current lighting zone levels Note: Zones 1, 2, and 3 are integral line voltage dimming zones that can control line voltage loads. emaining zones are EcoSystem zones only. Zones 1, 2, and 3 can be either EcoSystem zones or line voltage zones (no zone can be both) { 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 Info screen Displays status or programming functions s Temporarily raise and lower lighting levels on unit Optional Shade groups Preset and raise/lower s with integral LEDs (maximum of 3 groups) Displays current timeclock info Used for programming, fade time Scene s With integral scene indicator LEDs Hinged faceplate Infrared receiver For handheld remote use USB type mini B For programming via PC Note: 6-zone control unit will show only zones 1 through 6. GAFIK Eye QS with EcoSystem Installation and Operation Guide

Wiring the GAFIK Eye QS with EcoSystem : Overview of Line Voltage/Mains and EcoSystem Wiring Two E1 and two E2 connections are provided for ease of wiring, and to provide two connecting points; there is only one EcoSystem link on the unit. Note: Ballasts and other EcoSystem devices must NOT obtain power from a line voltage output on the GAFIK Eye QS with EcoSystem. EcoSystem Bus Wiring (See page 7 for complete wiring specification) Two AWG (1.5 mm 2 ) each terminal E1 E2 L N Line Voltage/Mains Cables and Load Wiring 12 AWG (4.0 mm 2 ) each terminal E1 E2 EcoSystem devices: ballasts, drivers, or interfaces L N To additional EcoSystem devices Distribution Panel Terminal labels: L: Hot/Live N: Neutral : Ground 1, 2, 3: Dimmed/Switched line voltage outputs Incandescent load 120-127 V or 220-240 V Distribution Panel Load controlled by power module Power module GAFIK Eye QS with EcoSystem Installation and Operation Guide 4

LUTON LUTON Wiring the GAFIK Eye QS with EcoSystem : Line Voltage Wiring Details Use properly certified cable for all line voltage/mains cables. Proper short-circuit and overload protection must be provided at the distribution panel. You can use up to a 20 A circuit breaker for your installation. Install in accordance with all local and national electrical codes. PELV (Class 2: USA) terminals may be temporarily unplugged for ease of I, occupancy sensor, and control wiring. Notice: isk of damage to unit. Do not connect line voltage/mains cable to PELV (Class 2: USA) terminals. Step 1: Install wallbox. Mount a 3½-in (89 mm) deep 4-gang U.S. wallbox on a dry, flat indoor surface that is accessible and allows for system programming and operation. Allow at least 4½ in (110 mm) clearance above and below the faceplate to ensure proper heat dissipation. Allow 1 in (25 mm) for faceplate overhang on all sides. Note: 4-gang wallbox available from Lutron; P/N 241400. 4.5 in (110 mm) Faceplate overhangs wallbox on all sides; allow 1 in (25 mm) Step 2: Test load wiring. Turn power OFF at the circuit breaker or fuse box. Connect a standard light switch between the live lead and load wire to test the circuit. Turn power ON and check for short or open circuits. If load does not operate, the circuit is open. If the circuit breaker trips (fuse blows or opens), a load short may exist. Correct short or open circuits and test again. ` Hot/Live Neutral Switch Load Step 3: Check control unit wiring. Earth/ground terminal connection must be made as shown in wiring diagrams (see page 4). Do not mix different load types on the same zone. Follow all local and national electrical codes when installing PELV (Class 2: USA) wiring with line voltage/mains wiring. WANING! Shock hazard. May result in serious injury or death. Always turn off circuit breaker or remove main fuse from power line before doing any work. Before connecting the loads to the GAFIK Eye QS with EcoSystem control unit, test the loads for short-circuits. GAFIK Eye QS with EcoSystem Installation and Operation Guide 5

Wiring the GAFIK Eye QS with EcoSystem : Line Voltage Wiring Details (continued) Step 4: Connect line voltage and loads to control unit. Strip 5/ inch (8 mm) of insulation off the line voltage/mains cables in the wallbox. 5/ inch (8 mm) Connect the line voltage/mains, ground, and load wires to the appropriate terminals on the back of the control unit. L: Hot/Live N: Neutral : Ground Terminals 1, 2, 3: Dimmed/Switched line voltage outputs The recommended installation torque is 5.0 in lbs (0.6 N m) for line voltage/mains connections and 5.0 in lbs (0.6 N m) for the earth/ground connection. Note: See page 19 for a list of compatible load types and instructions for programming the GAFIK Eye QS with EcoSystem to properly recognize them. Notice: isk of damage to unit. GAFIK Eye QS with EcoSystem control units must be installed by a qualified electrician in accordance with all applicable regulations and building codes. Improper wiring can result in damage to control units or other equipment. Note: To avoid overheating and possible damage to equipment, do not install control units to dim receptacles, motor-operated appliances, or fluorescent lighting not equipped with Lutron Hi-lume, Eco-10, Tu-Wire, EcoSystem electronic dimming ballasts, or other EcoSystem devices approved for your location. In dimmed magnetic low-voltage circuits, you can prevent transformer overheating and failure by avoiding excessively high current flow. Do not operate control units with any lamps removed or burned out; replace any burned out lamps immediately; use only transformers that incorporate thermal protection or fused primary windings. Control units are designed for residential and commercial use, for indoor use only. GAFIK Eye QS with EcoSystem Installation and Operation Guide 6

Wiring the GAFIK Eye QS with EcoSystem : EcoSystem Bus Wiring Details EcoSystem bus wiring may be considered NEC Class 1 or PELV (Class 2: USA). NEC Class 1: EcoSystem bus wiring may be run in the same conduit as mains voltage wiring to fixtures. PELV (Class 2: USA): EcoSystem bus wiring must be separated from all mains and NEC Class 1 wiring. Consult applicable national and local codes for compliance. Lutron recommends using two different colors for E1 and E2 (EcoSystem bus) wires. This will prevent wiring mistakes in junction boxes where several different EcoSystem bus wires combine. Use the following instructions for wiring the EcoSystem bus. Each EcoSystem link can have only 1 GAFIK Eye QS with EcoSystem connected to it. No additional EcoSystem bus supplies can be on the link. Up to 64 EcoSystem devices can be connected to the EcoSystem link. No other devices may be connected to the EcoSystem link. WANING! Shock hazard. May result in serious injury or death. Do not wire live. Interrupt power via circuit breaker before wiring and servicing the EcoSystem bus supply. Step 1: Use the wire size chart at right to determine which wire size to use based on the length of the EcoSystem bus. Step 2: Wire the EcoSystem bus from terminal E1 and terminal E2 to all EcoSystem devices. Step 3: Separate EcoSystem wiring from the mains wiring. If wiring the EcoSystem bus as PELV (Class 2: USA), maintain proper separation from mains and NEC Class 1 wiring. Step 4: Turn on circuit breaker to energize. EcoSystem Bus 18 V 250 ma Wiring Size and Bus Length EcoSystem bus wires E1 and E2 are not polarity sensitive. EcoSystem bus length is limited by the wire gauge used for E1 and E2 as follows: Wire Gauge 12 AWG (4.0 mm 2 ) 14 AWG (2.5 mm 2 ) AWG (1.5 mm 2 ) 18 AWG (1.0 mm 2 ) Maximum EcoSystem Bus Length 2200 ft (671 m) 1400 ft (427 m) 900 ft (275 m) 570 ft (175 m) Note: Some EcoSystem devices (ballasts, drivers, and interfaces) accept connections to daylight sensors and occupancy sensors. For instructions on installing and operating these devices, refer to their individual instruction sheets. EcoSystem bus wiring cables ( AWG) are available from Lutron, part numbers C-CBL-2-G-1 (non-plenum) and C-PCBL-2-CL-1 (plenum). GAFIK Eye QS with EcoSystem Installation and Operation Guide 7

Wiring the GAFIK Eye QS with EcoSystem : Overview of PELV (Class 2: USA) Wiring I Wiring 18 AWG (1.0 mm 2 ) each terminal From external I connection (by others) 1 2 1: I DATA 2: I COM Contact Closure Input Wiring For settings, see page 26. Example: Occupancy sensor (maximum 1) Signal +V Input Circuit Common LUT-ELI-3PH A B C 18 AWG (1.0 mm 2 ) each terminal A B C Example: Emergency lighting interface (maximum 1) Note: The GAFIK Eye QS control unit must be powered by a Normal/Emergency distribution panel for proper ELI operation. efer to the LUT-ELI-3PH Installation Guide for the complete wiring diagram. A: CCI SIG B: 24 V C: CCI COM A: CCI SIG B: 24 V C: CCI COM Control Wiring Common and power (terminals 1 and 2): Two 18 AWG (1.0 mm 2 ) each terminal To control stations, shades, or other GAFIK Eye QS control units 1 2 3 4 Data (terminals 3 and 4): Twisted, shielded pair 22 AWG (0.5 mm 2 ) each terminal 1: COM 2: 24 V * 3: MUX 4: MUX * Do not connect terminal 2 between any GAFIK Eye QS and any other power supply, including another GAFIK Eye QS. See page 10 for detailed wiring example. Note: Use appropriate wire connecting devices as specified by local codes. GAFIK Eye QS with EcoSystem Installation and Operation Guide 8

LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON 3.75 1.06 LUTON LUTON LUTON LUTON LUTON 2.50 5.26 4.26 LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON LUTON Wiring the GAFIK Eye QS with EcoSystem : QS Link Control Wiring Details System communication uses PELV (Class 2: USA) wiring. Follow all local and national electrical codes when installing PELV (Class 2: USA) wiring with line voltage/mains wiring. Each terminal accepts up to two 18 AWG (1.0 mm 2 ) wires. Total length of control link must not exceed 2000 feet (610 m). Make all connections in the control unit s wallbox. Wiring can be T-tapped or daisy-chained. Wire sizes: - Two 18 AWG (1.0 mm 2 ) conductors for control power. - One twisted, shielded pair of 22 AWG (0.5 mm 2 ) for data link. - Cable is available from Lutron: GX-CBL-346S-500 (non-plenum) and GX-PCBL-346S-500 (plenum). Check compatibility in your area. PELV (Class 2: USA) 24 V 150 ma. T-Tap Wiring Example To EcoSystem link 1 System Limits The QS wired communication link is limited to 100 devices or 100 zones. Please note the zone count and power draw unit information in the following table. QS Device Zone Count Power Draw Units (supplied) 3-zone GAFIK Eye QS 3 3 0 4-zone GAFIK Eye QS 4 3 0 6-zone GAFIK Eye QS 6 3 0 8-zone GAFIK Eye QS 8 3 0 -zone GAFIK Eye QS 3 0 seetouch QS 0 0 1 International seetouch QS 0 0 1 Power Draw Units (consumed) Sivoia QS 1 0 (efer to Spec. Submittal) Contact closure interface 5 0 3 Network interface 0 0 2 DMX interface 0 0 2 QS smart power panel 0 (efer to Spec. Submittal) QS link power supply 0 8 0 0 GAFIK Eye QS with EcoSystem seetouch QS QS smart power panel To EcoSystem link 2 GAFIK Eye QS with EcoSystem Daisy-Chain Wiring Example To EcoSystem link 1 Sivoia QS GAFIK Eye QS with EcoSystem To EcoSystem link 2 seetouch QS Sivoia QS QS smart power panel GAFIK Eye QS with EcoSystem Installation and Operation Guide 9

Wiring the GAFIK Eye QS with EcoSystem : QS Link Control Wiring and Terminal Connection Example Control units shown in rear view QS1 QS3 QS2 and QS3 have their own power supply; no terminal 2 connection QS3 powers wallstations 2, 3, and 4; no terminal 2 connection between wallstations 4 and 5 4 3 2 1 5 Connect the terminal 1, 3, and 4 connections to all control units, wallstations, and control interfaces. Each control unit has its own power supply. Terminate the terminal 2 connection (24 V power) so that each control unit supplies power to a maximum of three wallstations. Do not connect terminal 2 between a GAFIK Eye QS control unit and any other GAFIK Eye QS control unit and/or another power supply. Each wallstation should receive power from only one control unit. 6 4 3 2 1 1 QS1 powers wallstation 1 only; terminal 2 terminates at wallstation 1 4 3 2 1 4 3 2 2 3 4 3 2 1 4 3 2 1 7 Sivoia QS smart power supply panel Power panel powers this shade only QS2 1 4 3 2 1 4 1 2 3 4 5 6 L N QS4 GAFIK Eye QS control unit (no EcoSystem link) 1 2 A B C 1 2 3 4 Sivoia QS shade E1 EcoSystem link E1 E2 E2 EcoSystem devices: ballasts, drivers, and interfaces QS4 powers wallstations 5, 6, and 7 only; no terminal 2 connection between wallstations 4 and 5 To additional EcoSystem devices GAFIK Eye QS with EcoSystem Installation and Operation Guide 10

Wiring the GAFIK Eye QS with EcoSystem : Powering More Than 3 Wallstations The GAFIK Eye QS with EcoSystem can power up to 3 seetouch wallstations. An external 24 V power supply is required to power more than three wallstations. The +24 VDC wire from the power supply connects to QS link terminal 2 on all of the wallstations it is powering. This wire does not connect to terminal 2 on the GAFIK Eye QS. The Common wire from the power supply connects to QS link terminal 1 on all of the wallstations it is powering and terminal 1 on the GAFIK Eye QS. The communication signals on the QS link (terminals 3 and 4) connect from the wallstations to the GAFIK Eye QS on twisted, shielded cable just as when an additional power supply is not being used. Control unit shown in rear view. GAFIK Eye QS with EcoSystem control unit (rear view) 1 twisted pair 22 AWG (0.5 mm 2 ) Lutron cable GX-CBL-346S-500 (non-plenum) or GX-PCBL-346S-500 (plenum) seetouch QS wallstations 1 2 3 4 4 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 1 2 A B C (1) 18 AWG (1.0 mm 2 ) Common QSPS-P1-1-50 (powers up to 8 seetouch QS wallstations) To power source GAFIK Eye QS with EcoSystem Installation and Operation Guide 11

Completing Installation of the GAFIK Eye QS with EcoSystem 1. Mount the control unit in the wallbox as shown using the four screws provided. Note: Follow all local and national electrical codes when installing PELV (Class 2: USA) wiring with line voltage/ mains wiring. 2. Verify installation: estore power. Press the top scene. The LED will light. Press the zone raise or lower. Make sure the control unit is dimming all connected loads. 3. Apply the protective overlay to the control unit. See page 21 for instructions for naming zones. 7.9 in (200 mm) 3.5 in (87 mm) 3.75 in (95 mm) Note: When tightening mounting screws, make sure that the hinged cover and faceplate will open fully, as shown. Wall Protective overlay (apply after installation) GAFIK Eye QS with EcoSystem Installation and Operation Guide 12

General Functionality The info screen turns off 30 seconds after the last press or completion of the last scene change. See example screens below. The s activate the info screen. These s temporarily raise or lower all dimmable lights (except those programmed as unaffected in the current scene). Adjustments are temporary and do not affect scene programming. Note: s affect all zones. Scene 1 raise lower The activates the info screen (when off), which then Scene 1 shows the current scene and its fade time. In Save Always mode, it allows fade time adjustment. In Save by mode, pressing Adjust fade a second time allows zone adjustment; pressing a third time 3 seconds allows fade adjustment. The timeclock activates the info screen and displays the current time and the next event scheduled to occur. Pressing a second time displays the time, date, and afterhours status. Pressing a third time displays location and sunrise/sunset times. Pressing a fourth time displays the language selection screen. Pressing once more returns to the first screen. 11:23 AM Fri Next: 5:00 PM Scene 1 The page is on -zone units only. Pressing the page will toggle the unit between page 1 (zones 1 through 8) and page 2 (zones 9 through ). Two LEDs above each zone LED bar indicate the unit s current page. Upon switching pages, the LED bars for all 8 zones of that page will show their level for the current scene. GAFIK Eye QS with EcoSystem Installation and Operation Guide 13

Pre-Programmed Button Functionality The GAFIK Eye QS with EcoSystem controls most lighting loads without special programming. Each unit ships with pre-programmed default settings for the scene and shade s. For load types other than those shown below (dimmable or non-dim), set the load type before proceeding. See pages 18-19 for instructions on setting load type. See page 39 for instructions on changing scene settings. Scene Button Pre-Programming for Dimmable Loads Scene 1: All zones to 100% Scene 2: All zones to 75% Scene 3: All zones to 50% Scene 4: All zones to 25% All zones Off Shade Button Pre-Programming for Sivoia QS shades All shades fully open All shades to 50% All shades fully closed Lower/aise all shades (Applies only to units with shade keypads) GAFIK Eye QS with EcoSystem Installation and Operation Guide 14

Zone Button Operation Each zone column (LEDs and s) represents one zone of lights. On -zone units, the page toggles between zones 1 through 8 and zones 9 through. Page LEDs above each column will indicate which zone is currently active on the control unit. Pressing any on a column turns on the info screen and displays the zone s current light level and current energy savings. Zone LEDs LEDs indicate light level (see below) Zone aise Zone Lower 2 10 3 11 1 9 2 10 3 11 4 12 5 13 Pressing the raise and lower s on a zone causes different actions depending on zone type (see below). Dimmable zones: Press and hold to raise/lower all lights in a zone; release to stop Press raise or lower to stop a zone that is fading aising lights from off to full on or lowering from full on to off takes 5 seconds Press raise and lower simultaneously to toggle between full on and off Press and hold lower for 6 seconds after the zone has gone to 0% light level to set the zone as unaffected in the current scene (the zone will not change when this scene is initiated) Non-dim zones: Press raise to turn zone on Press lower to turn zone off Note: To set zone types, see pages 18-19. Zone LED Displays for % of Lighting Levels Light Level (%) Dimmable Load Types Non-Dim Load Types Off 1 17 18-33 34-49 50-66 67-82 83-99 On/ 100 Legend: UA = Unaffected (lights are not affected by scene or s) LED lit LED off UA GAFIK Eye QS with EcoSystem Installation and Operation Guide 15

Programming Mode Entering and Exiting Programming Mode Main menu Scene setup Scene 1 Fade time 3 seconds To enter programming mode: Press and hold the top and bottom scene s simultaneously for 3 seconds. The LEDs in the scene s will scroll from top to bottom, confirming that you are in programming mode, and the info screen will display the main menu. To exit programming mode: Press and hold the top and bottom scene s simultaneously for 3 seconds. The info screen will go to Scene 1. s (back) Press and hold the top and bottom s for 3 seconds to enter or exit programming mode Navigating Menus in Programming Mode Buttons The s allow you to move through the menu choices. The current choice is highlighted on the info screen. Button The chooses the current highlighted menu choice. This will either take you to the next menu or accept a setting you have selected. When the screen displays a Yes/No question, the is Yes. Button The timeclock functions as a back during programming mode. Pressing the timeclock takes you back one step in the current menu. Pressing it repeatedly will eventually return you to the main menu, but will not exit programming mode. When the screen displays a Yes/No question, the is No. GAFIK Eye QS with EcoSystem Installation and Operation Guide

Wireless Mode Many models of the GAFIK Eye QS support wireless communication with other Lutron products. This feature allows for easy integration of wireless sensors, keypads, remotes, and shades for single-room wireless applications, as well as compatibility with other Lutron wireless systems such as adioa 2. (See the adioa 2 Installation Guide for adioa 2 setup.) Units supporting wireless communication have model numbers beginning with QSGJ or QSGK. The wireless feature of the GAFIK Eye QS Wireless control unit has three (3) modes of operation. Disabled: Use for wired-only systems. Enabled: The GAFIK Eye QS Wireless control unit will respond to any programming commands from nearby Lutron QS wireless (and compatible) products. Ignore Programming (default): The GAFIK Eye QS Wireless control unit will only respond to normal operation commands from wireless devices programmed while in Enabled mode. To change the wireless mode of the GAFIK Eye QS wireless control unit: Main menu 1. Enter programming mode (see page ). 2. Use the s to highlight Wireless Mode and press Shade labels the to accept. Wireless Mode 3. Use the s to highlight the desired wireless mode, and press the to accept. 4. The info screen will display a confirming Saved message. Wireless Mode 5. Exit programming mode (see page ). Enabled SavedSaved Notes The wireless signal has a range of 30 feet (10 m) through standard construction. When used within a adioa 2 system, the wired QS link on the GAFIK Eye QS is disabled, and certain features that do not pertain to adioa 2 are not accessible. s (back) FCC Information Changes or modifications not expressly approved by Lutron Electronics Co. could void the user s authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. Operation is subject to the following: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential and commercial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: eorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. GAFIK Eye QS with EcoSystem Installation and Operation Guide 17

Zone Setup Assign Load Types Main menu CCI Mode Zone setup Zone Setup Load Type Non-Dim Load Type Load Type Set zones Saved 1. Enter programming mode (see page ). 2. Use the s to highlight Zone setup and press the to accept. 3. Use the s to highlight Load type. Press the to accept. See Setting Load Types table on the next page. 4. Use the zone raise/lower s to choose the load type for that zone. See the list on the next page for supported load types. Press the to accept. 5. The info screen will confirm that your load type has been saved. 6. Exit programming mode (see page ). 1 9 2 10 3 11 4 12 5 13 6 1 s Use the zone raise/lower s to choose the load type for that zone. Assign Non-Dim Load Type Zones assigned to non-dim loads have three available configurations: Main menu LOFO: Last On, First Off FOFO: First On, First Off CCI Mode FOLO: First On, Last Off Zone setup Scenes made up of both dim and non-dim load types will toggle the non-dim loads before the dim loads in a First on/off Zone Setup configuration, and after the dim loads in a Last on/off configuration. Load Type 1. Enter programming mode (see page ). Non-Dim Load Type 2. Use the s to highlight Zone setup and press the to accept. 3. Use the s to highlight Non-Dim Load Type Load type. Press the to accept. Set zones See Setting Load Types table on the next page. 4. Use the zone raise/lower s to choose the non-dim load type for that zone. (Zones not programmed as non-dim will be displayed as Unaffected.) Press the to accept. Saved 5. The info screen will confirm that your load type has been saved. 6. Exit programming mode (see page ). GAFIK Eye QS with EcoSystem Installation and Operation Guide 18

LUTON LUTON Zone Setup (continued) Zones 1 3 Zones 4 Setting Load Types Fixture load type Direct control via GAFIK Eye QS To EcoSystem link Control via power module Choose this load type from the menu on the GAFIK Eye QS: Incandescent Incandescent Power module MLV (magnetic low-voltage) MLV Power module ELV (electronic low-voltage) Power module Hi-Lume /Eco-10 Fluorescent module Non-dim lighting loads Non-dim Neon/Cold cathode Neon, CC Neon, CC Tu-Wire Tu-Wire Tu-Wire EcoSystem EcoSystem DMX DMX GB/CMYK DMX GB/CMYK DMX EcoSystem switching (e.g., XPJ) Non-dim digital EcoSystem EcoSystem DMX DMX GB/CMYK DMX GB/CMYK DMX EcoSystem switching (e.g., XPJ) Non-dim digital Power module Load Type Notes All electronic low-voltage (ELV) lighting used with an interface must be rated for reverse phase control dimming. Before installing an ELV light source, verify with the manufacturer that their transformer can be dimmed. When dimming, an ELV interface (such as the PHPM-PA-DV-WH) must be used with the control unit. For all DMX or GB/CMY DMX lighting, an external DMX interface (such as the QSE-CI-DMX) must be used with the control unit. For non-ecosystem loads: Not all zones must be connected; however, connected zones must have a minimum load: 120-127 V : 25 W 220-240 V : 40 W Maximum zone loads: 120-127 V : 800 W 220-240 V : 1200 W Maximum total lighting load for a magnetic low-voltage (MLV) varies by input voltage: 120-127 V : 800 VA / 600 W 220-240 V : 1200 VA / 960 W GAFIK Eye QS with EcoSystem Installation and Operation Guide 19

Zone Setup Set High End or Low End Trim If you are unsure about appropriate high and low end settings, please contact Lutron Technical Support for assistance. High and low end trim settings limit the maximum and minimum output of a dimming zone. Trim levels are set automatically when the load type is programmed. High end and low end trims are not applicable to EcoSystem zones. Main menu 1. Enter programming mode (see page ). 2. Use the s to highlight CCI Mode Zone setup and press the to Zone setup accept. 3. Use the s to highlight High end or Low end (this example shows Zone setup low end). Press the to accept. High end 4. Use the zone raise/lower s to set the high end or low end trim for that Low end zone. The info screen will display each zone number and percentage as you adjust it. Press the to accept. Low end 5. The info screen will confirm that your setting has been saved. Set zones 6. Exit programming mode (see page ). Zone 2 10% Set Minimum Level (optional) Some local regulations specify a minimum lighting level for dimming zones in occupied buildings. If this pertains to you, follow these steps to set up your minimum lighting level. Zone setup 1. Enter programming mode (see page ) and select Zone setup, then Min level. Low end Press the to accept. Min level 2. Use the s to highlight OFF if you want your lights to go all the way off at their minimum light level, Min level or 10% if you want that to be the minimum light level. Press the to accept. Off Note: Non-dim loads will turn off regardless of the minimum level setting. 3. The info screen will confirm that your minimum level has been saved. 4. Exit programming mode (see page ). Saved 1 9 2 10 3 11 4 12 5 13 6 1 s Use the zone raise/lower s to set the high end or low end trim for that zone. Saved GAFIK Eye QS with EcoSystem Installation and Operation Guide 20

Zone Setup Label a Zone (optional) Main menu 1. Enter programming mode (see page ). 2. Use the s to highlight Zone setup and press CCI Mode the to accept. Zone setup 3. Use the s to highlight Label and press the to accept. 4. Use the s to change the zone number to your Zone setup desired zone. Custom zone labels will appear if previously set. Press the to accept. Min level 5. Use the s to highlight Custom and press the Label to accept. Or, highlight Default to return the zone label to the default (e.g., Zone 1). 6. Use the s to scroll through the characters Label zone (lowercase and uppercase letters, plus numbers 0 through 9). The character you are currently changing will be underlined Zone 2 on the screen. Press to select the character you want, then repeat for all available characters. Choose a space (no character) and press for any remaining characters. Press the to accept. Label zone 2 Note: Custom zone labels will always begin with the zone number and a colon (e.g., 1: Uplights). Custom 7. The info screen will confirm that your name has been saved. 8. Exit programming mode (see page ). Note: On -zone units, each column of s will represent Label zone 2 2 zones of light, one on page 1 and the other on page 2. Pressing a raise/lower in column 1 while on page 1 (Zone 1) 1 / 11 A does not affect the level of column 1/page 2 (Zone 9). 1: A s Saved GAFIK Eye QS with EcoSystem Installation and Operation Guide 21

Application Suggestions and Differences between GAFIK Eye QS with EcoSystem and Standard EcoSystem Bus Supply Lutron s EcoSystem is a powerful system comprised of sensors and lighting loads (ballasts, drivers, and interfaces). The functionality, feature set, and setup procedures for EcoSystem depend upon the main controlling device, or bus supply. The GAFIK Eye QS with EcoSystem differs from the standard EcoSystem bus supply as indicated below. Suggested/ecommended Applications GAFIK Eye QS with EcoSystem Single rooms, partitioned spaces e.g., conference room, classroom, ballroom, lobby EcoSystem Bus Supply Open spaces, multiple enclosed rooms e.g., open office, window offices Programming Method Info Screen on the QS control unit Via PDA or EcoSystem keypads Yes (integral) No Compatible with seetouch QS Keypads Compatible with EcoSystem Wall Controls Yes No Compatible with EcoSystem I Sensors No Yes Programming from EcoSystem PDA No Yes Programming from EcoSystem Wall Control Includes dry contact closures for integration to BMS or Security Systems No No Yes Yes Yes (1) Yes (2) Input Voltage 120-127 V or 220-240 V 50/60 Hz 120 / 240 / 277 V 50/60 Hz Number of EcoSystem Busses 1 1 or 2 Number of Zones 6, 8, or Number of Line Voltage Zones 3 (Zones 1-3 only) Compatible with other QS Devices Yes No GAFIK Eye QS with EcoSystem Installation and Operation Guide 22

EcoSystem Setup Overview After EcoSystem devices are wired and powered, they must be reset and addressed so the system can control them. The Build System command automates this process, as shown below. (For best results, force occupancy sensors attached to EcoSystem devices to the occupied state by creating motion within their range while building the system.) Note: All existing EcoSystem programming will be deleted when the Build System command is run. Build System Main menu Zone setup EcoSystem EcoSystem Build system Assign zones Build system Erase digital load Programming? 1. Enter programming mode (see page ). 2. Use the s to highlight EcoSystem and press the to accept. 3. Use the s to highlight Build system and press the to accept. 4. Press the to erase all current programming, reset and address EcoSystem devices, and find sensors on the system. 5. Exit programming mode (see page ). Note: After running Build System, Zone 4 will control all EcoSystem devices for diagnostics and verification of wiring. (This feature is disabled once any of the addressed devices are assigned to a zone on the GAFIK Eye QS.) Use the Zone 4 raise/lower s to verify that all devices are correctly addressed. If a device does not respond, repeat the Build System command and/or check the wiring. 1 9 2 10 3 11 4 12 5 13 6 1 s (back) Use Zone 4 raise/lower s to verify all EcoSystem devices have been addressed. Searching... x Found x Loads Found GAFIK Eye QS with EcoSystem Installation and Operation Guide 23

EcoSystem Setup Assign/Unassign an EcoSystem Device to a Zone (Zone setup) EcoSystem devices must be addressed on the system (see previous page) before assigning or unassigning to a zone. Main menu Zone setup EcoSystem Zone setup EcoSystem Assign zones Address All Assign zones Ballast 2 / 23 *Unassigned* Assign zones Ballast 2 / 23 1. Enter programming mode (see page ). 2. Use the s to highlight EcoSystem and press the to accept. 3. Use the s to highlight Assign zones and press the to accept. 4. Press the to select Ballast. 5. Use the s to scroll through the EcoSystem devices on the link. The selected device will flash, and the info screen will display the device number and the number of devices on the link. If the device is currently assigned to a zone, the zone number will display at the bottom of the screen and the LEDs for the zone will go on; otherwise, the info screen will display *Unassigned*. Press the zone raise to assign the device to that zone. Press the zone lower to unassign the device to that zone. 6. Press the timeclock (back) to return to the EcoSystem menu. EcoSystem devices will return to normal levels. 7. Exit programming mode (see page ). 1 9 2 10 3 11 4 12 5 13 6 1 Zone LEDs s (back) Use the zone raise or lower to assign or unassign an EcoSystem device to that zone. Zone 3 Notes Devices that were previously assigned to a zone will be removed from the old zone and assigned to the new zone (each device can be assigned to only 1 zone at a time). Devices can be assigned only to zones set to EcoSystem load type. efer to page 18 for instructions on changing load type. GAFIK Eye QS with EcoSystem Installation and Operation Guide 24

EcoSystem Setup Address EcoSystem Devices Note: This step is needed if EcoSystem devices are replaced or added to the system after the Build System command is run (see page 23). EcoSystem Assign zones Address all Address all Address all? Press 1. Enter programming mode (see page ). 2. Use the s to highlight EcoSystem and press the to accept. 3. Use the s to highlight Address all and press the to accept. All EcoSystem devices in the system will go to full On. As each EcoSystem device is addressed, the GAFIK Eye QS will display information about it, and the device will go to its low end. This will take several minutes. The system will then return to the main menu. 4. Exit programming mode (see page ). s Addressing info GAFIK Eye QS with EcoSystem Installation and Operation Guide 25

Contact Closure Input (CCI) Mode Setup (wired directly to the GAFIK Eye QS) The integral contact closure input (CCI) on the back of the GAFIK Eye QS can be configured to match the installation requirements. The choices are listed and explained below. (See page 8 for wiring details.) To change the operation of the contact closure input: Main menu Save Mode CCI Mode CCI Mode 1. Enter programming mode (see page ). 2. Use the s to highlight CCI Mode and press the to accept. 3. Use the s to highlight the mode you wish the CCI to control. Press the to accept. 4. The info screen will confirm that your setting has been saved. 8. Exit programming mode (see page ). s (back) Occupancy Saved Saved CCI Mode Settings Occupancy: Allows a wired occupancy sensor to be included in the list of available sensors when setting up occupancy actions. Emergency: This setting allows the GAFIK Eye QS to work with a LUT-ELI-3PH emergency lighting interface. When an emergency situation is detected, all lights will go to full on, and no operations will be allowed until the emergency signal is cleared. Afterhours: Allows the CCI to start and end the afterhours mode. : Allows the CCI to enable and disable the timeclock. Lockout: Prevents the user from making any changes to the control unit. The current scene will stay on until the CCI enables normal operation. Never Save: Prevents any changes from being saved while the CCI is being used. Disable CCI: The CCI will have no effect on the system and will not appear on the list of available occupancy sensors within the sensor setup menu. GAFIK Eye QS with EcoSystem Installation and Operation Guide 26

Associating Wireless Occupancy Sensors and GAFIK Eye QS Wireless Control Units (for wireless enabled units only) Lutron s wireless adio Powr SavrTM occupancy and vacancy sensors can be associated with the GAFIK Eye QS Wireless to activate scenes when occupancy or vacancy is detected. This section applies to installations where the GAFIK Eye QS Wireless is being used in a single-room wireless installation. efer to the adioa 2 installation guide for setting up occupancy and vacancy sensors in a adioa 2 system. To associate wireless occupancy sensors and GAFIK Eye QS control units: 1. Make sure the wireless mode of the GAFIK Eye QS control unit is Enabled (see page 17). 2. Press and hold the Lights On and Lights Off s on the front of the occupancy/vacancy sensor simultaneously until the lens starts flashing (about 3 seconds). The info screen on the GAFIK Eye QS will display Occ Sensor Programming. 3. Press and hold the top scene of the GAFIK Eye QS Wireless control unit until the LEDs flash (about 3 seconds). 4. eturn to the occupancy sensor. Press and hold the Lights On and Lights Off s simultaneously until the lens stops flashing (about 3 seconds). 5. Test communication between the devices using the Lights On and Lights Off s. To disassociate wireless occupancy sensors and GAFIK Eye control units: Simply repeat the association steps, in the same order; press and hold the bottom scene on the GAFIK Eye QS to disassociate. Note: The wireless signal has a range of 30 feet (10 m) through standard construction. Lens 1 2 3 4 5 6 On the wireless occupancy sensor, press and hold the Lights On and Lights Off s for 3 seconds to begin or end association or disassociation with the GAFIK Eye QS control unit. Note: Pressing the Lights On initiates the occupied action on the GAFIK Eye QS control unit. Pressing the Lights Off initiates the unoccupied action. Associate O Disassociate On the GAFIK Eye QS control unit, press and hold the top scene for 3 seconds to associate, or press and hold the bottom scene for 3 seconds to disassociate with the occupancy sensor. Wireless Occupancy Sensor Talks to GAFIK Eye QS control unit, activating scenes on the GAFIK Eye QS. GAFIK Eye QS Control Unit Listens to wireless occupancy sensor, so that the occupancy sensor activates scenes on the GAFIK Eye QS. GAFIK Eye QS with EcoSystem Installation and Operation Guide 27

Occupancy Sensor Setup Mode Assignment This step allows you to assign occupancy sensors (wired and wireless) on the QS link or connected to the GAFIK Eye QS control unit. Sensors can be assigned in either Scene Mode or Zone Mode. Scene Mode (default) is useful when the GAFIK Eye QS is controlling lights in a single room or area. Up to four sensors can be assigned to the GAFIK Eye QS to activate a scene when the space is occupied, and another scene when unoccupied. Zone Mode is useful when the GAFIK Eye QS is controlling lights in multiple rooms or areas. Up to four sensors can be assigned to each zone (a sensor can be assigned to more than one zone) to send the zones to user-selectable occupied and unoccupied levels. Main menu 1. Enter programming mode (see page ). 2. Use the s to highlight Sensor setup and press Sensor Setup the to accept. Shade Labels 3. Use the s to highlight Occupancy and press the to accept. 4. Use the s to highlight Mode and press the Sensor Setup to accept. Daylight 5. Use the s to highlight Scene Mode to assign Occupancy sensors to scenes, or Zone Mode to assign sensors to zones. Press the to accept. A screen will confirm your selected mode has been saved and you will return to the Occ Sensor screen. Occ Sensor s (back) Mode Actions To configure Scene Mode, see page 29. To configure Zone Mode, see page 30. Occ Sensor Occ Sensor Scene Mode O Zone Mode SavedSaved GAFIK Eye QS with EcoSystem Installation and Operation Guide 28

Occupancy Sensor Setup Scene Mode This step allows you to assign occupied and unoccupied scenes to up to four occupancy sensors connected to the GAFIK Eye QS control unit. Occ Sensor Setup Labels Saved Searching Sensor SN: xxxx-xxxx x/y Source: F 1/n Assignment Assign Unassign Select Sensors 1. If not already done, complete the steps on page 28, and select Scene Mode. 2. Use the s to highlight Setup and press the to accept. The screen will display Searching while the unit detects available occupancy sensors. 3. Use the s to scroll through the list of available occupancy sensors. When the desired sensor is displayed, press the to select it. Then choose Assign or Unassign from the following menu and press. A screen will verify your choice has been completed. epeat for additional sensors. Set Sensor Action 4. Press the Back to return to the Occ Sensor screen. Use the s to highlight Actions and press the to accept. By default, the occupied scene is set to No Action and the unoccupied scene is set to Scene Off. 5. Use the s to highlight the scene you wish to use for occupied status and press the to accept. epeat for the scene you wish to use for unoccupied status. Press the to accept. 6. Exit programming mode (see page ). Note: If wireless sensors are not found, verify that they are associated correctly (see page 27). s (back) Saved *Assigned* Occ Sensor Occupied Scene Unoccupied Scene Actions Setup 3 seconds Scene 1 Scene Off SavedSaved GAFIK Eye QS with EcoSystem Installation and Operation Guide 29

Occupancy Sensor Setup Zone Mode This step allows you to assign occupied and unoccupied zone levels to up to four occupancy sensors per zone connected to the GAFIK Eye QS control unit. Sensors can be added to more than one zone. Occ Sensor Select Sensors 1. If not already done, complete the steps on page 28, and Setup select Zone Mode. Labels 2. Use the s to highlight Setup and press the to accept. 3. Use the s to highlight Add/Modify and press Sensors the to accept. Available sensors will be displayed. 4. You can assign up to four sensors per zone, and a sensor can Add/Modify emove be assigned to more than one zone. Use the s to scroll through the sensors until the one you wish to assign or unassign is highlighted, and press the to select it. Sensor x/y 5. Use the zone raise and lower s for each zone to assign or unassign the sensor to that zone. The zone raise SN: xxxx-xxxx assigns the displayed sensor, and the zone lower Source: F 1/n unassigns it. epeat for all desired sensors and press. A screen will verify your settings have been saved. Saved Searching Sensor x/y Select Zones to Assign Set Sensor Action 6. Press the Back to return to the Occ Sensor screen. Use the s to highlight Actions and press the to accept. 7. Use the zone raise and lower s to adjust each zone to its desired occupied level and press the to accept. Press and hold the zone lower to designate a zone as unaffected by the sensor. epeat for the zone levels you wish to use for unoccupied status. Press the to accept. 8. Exit programming mode (see page ). Note: If wireless sensors are not found, verify that they are associated correctly (see page 27). 1 9 2 10 3 11 4 12 5 13 2 10 3 11 Zone raise Zone lower s (back) Occ Sensor Occupied Unoccupied Actions Setup 3 seconds Set Occupied Level for zones Set Unoccupied Level for zones SavedSaved GAFIK Eye QS with EcoSystem Installation and Operation Guide 30

Occupancy Sensor Setup Label an Occupancy Sensor (optional) Main menu Zone Setup Sensor Setup 1. Enter programming mode (see page ). 2. Use the s to highlight Sensor Setup and press the to accept. 3. Use the s to highlight Occupancy and press the to accept. Sensor Setup Daylight Occupancy 4. Use the s to highlight Labels and press the to accept. 5. Use the s to display an occupancy sensor to label and press to select. 6. Use the s to scroll through the characters (lowercase and uppercase letters, plus numbers 0 through 9). Occ Sensor The character you are currently changing will be underlined on the screen. Press to select the character you want, Labels Settings then repeat for all available characters. Choose a space (no character) and press for any remaining characters. Press the to accept. Sensor x/y 7. The info screen will confirm that your name has been saved. 8. Exit programming mode (see page ). s (back) SN: xxxx-xxxx Source: F 1/n Label sensor x/y 1: A 1 / 11 A Saved Saved GAFIK Eye QS with EcoSystem Installation and Operation Guide 31