Lighting Design Manufacturing Service Stellar Series Lighting Application Guide With the dynamic advancement in LED technology and its brightness efficacy exceed traditional light source, LED used in general lighting is an inevitable replacement as it brings many benefit with its advantage in reducing energy consumption. Since the beginning, Edison Opto has been devoted to promote high brightness LED used in the lighting market. As we have enable many custom pioneering design and applications. Edison Opto introduces this Step by step, easy read through guide book solely purpose to accelerate the integration of LED into various lighting products, and to help the customers in specifying the right Edison LEDs at Lighting.
Table of Contents Absolute Maximum Ratings...3 Application note...4 Accessory : Connector...6 Front connector and End Connector Series...7 Cutting spec & Cutting Caution...11 Assembly Caution...12 Revision History...13 About Edison Opto...13 2
Absolute Maximum Ratings Parameter Symbol Rating Units LED junction Temperature T j 90 Operating Temperature T opr 0 ~ +45 Storage Temperature T stg -20 ~ +45 o C o C o C Maximum Connection [2] -- 15 M Notes: 1. Proper current derating must be observed to maintain operating temperature below the maximum at all time. 2. Single side power input maximum length is 15m, if over 15m suggestion two side power input. Single side input power DC Input Two side input power DC Input DC Input 3
Application note 4
RGB Controller Signal Output RGB Controller Signal Output Signal Repeater Signal Repeater Signal Output Signal Output Adapter RGB Controller Signal Output 5
Accessory : Connector Waterproof connector Order Code : 13CNP2000001 Assembling Methods Step1 Make a connection between the male and female side of the wire. Please notice that the colors of the wires are different. Be sure the same color is connected at the same side. Step2 Use the recommended connector to link a light bar and a driver. Put the cables of the wire and driver into each side of the connector. Make sure the red cable of the wire is linked to the positive terminal of the driver (also in red), and vice versa. Step3 Ones the cables are inside of the connector, press down the bottom of the connector and make sure the cables are tight fixed. Cable preparation Before using, make sure the applicable cable is clean and free of superficial pollution like dust or other substances that can compromise the insulation level. When stripping the cable jacket make sure it is a straight clean cut and prevent at all times that the insulation of the wires within the cable are damaged or cut in. The stripped jacket end shall be cut under a maximum angle of 10. Proper cutting tooling shall be used to avoid spacing deformation and burrs. Wires terminated correctly Wires terminated incorrectly Notes: 1. The connector is used in Waterproof FPC Series. 2. The connector do not reuse. 3. To prevent the defect of water resistance, the bare wire is recommended to be cut off or be kept less than 2 millimeter. 6
Front connector and End Connector Series EDFRF10B Series Connector Picture Part No. Stellar series Wire Length 13CNP3000003 13CNP3000004 13CNP3000005 13CNP3000015 13CNP3000016 13CNP3000017 F10 Input - 01 F10 Input - 02 13MAFT000022 F10 End cap -- EDFRF F15 Series Connector Picture Part No. Stellar series Wire Length 13CNP3000006 13CNP3000007 13CNP3000008 13CNP3000018 13CNP3000019 13CNP3000020 13CNP3000009 13CNP3000010 13CNP3000011 13CNP3000021 13CNP3000022 13CNP3000023 F15A Input - 01 F15A Input - 02 F15B Input - 01 F15B Input - 02 13MAFT000023 F10 End cap -- 7
EDFRF F22 Series Connector Picture Part No. Stellar series Wire Length 13CNP3000027 13CNP3000030 13CNP3000033 13CNP3000028 13CNP3000031 13CNP3000034 13CNP3000029 13CNP3000032 13CNP3000035 F22A Input 13MAFT000025 F22A End cap --- 13CNP3000012 13CNP3000013 13CNP3000014 13CNP3000024 13CNP3000025 13CNP3000026 F22B Input - 01 F22B Input - 02 13MAFT000024 F22B End cap -- 8
Connector Type 01/02 Identification Wire anode and cathode or "+ Connector pin position 9
Clasp type Connector and End cap Installation Clasp Front Connector Installation Step Clasp End Cap Installation Step Screw type Connector and End cap Installation Screw Front Connector Installation Screw End Cap Installation Step 10
Cutting spec & Cutting Caution Cutting unit and LED Reduced Picture Part No. Stellar series Wire Length 6LBU1RXJK0G07201 125mm 9 6LBU1AXJK0G07201 125mm 9 EDFRF10 Series 6LBU1TXJK0G07201 83.3mm 6 6LBU1BXJK0G07201 83.3mm 6 6LBU1CWJK0G07201 83.3mm 6 6LBU1WWJK0G07201 83.3mm 6 6LBU1M1JK0M06001 100mm 6 EDFRF15 Series 6LBU1CWJK0M06001 100mm 6 6LBU1WWJK0M06001 100mm 6 6LBU1M1JJ0L07201 83.3mm 6 EDFRF22 Series 6LBU1CWJK0G10801 56mm 6 6LBU1WWJK0G10801 56mm 6 Cutting Caution 11
Assembly Caution EDFRF10B series minimum bent diameter and bending direction. Light Surface Light Surface Light Surface Light Surface Φ90mm Light Surface Light Surface Recommened Use EDFRF15A/B series minimum bent diameter and bending direction. Ligh t Surfac e 12 0mm Ligh t Surfac e Recommened Use EDFRF22A/B series minimum bent diameter and bending direction. Ligh t Surfac e 120m m Li gh t Su rfac e Ligh t Surfac e Recommened Use 12
Revision History Versions Description Release Date 1 Establish order code information 2016/02/02 About Edison Opto Edison Opto is a leading manufacturer of high power LED and a solution provider experienced in LDMS. LDMS is an integrated program derived from the four essential technologies in LED lighting applications- Thermal Management, Electrical Scheme, Mechanical Refinement, Optical Optimization, to provide customer with various LED components and modules. More Information about the company and our products can be found at Copyright 2016 Edison Opto. All rights reserved. No part of publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photo copy, recording or any other information storage and retrieval system, without prior permission in writing from the publisher. The information in this publication are subject to change without notice. For general assistance please contact: service@edison-opto.com.tw For technical assistance please contact: LED.Detective@edison-opto.com.tw 13