Lifetime of MCP-PMTs

Similar documents
Lifetime of MCP-PMTs

Performance of the MCP-PMT for the Belle II TOP counter

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

TORCH a large-area detector for high resolution time-of-flight

Very High QE bialkali PMTs

Review of High Quantum Efficiency Large Area Photomultiplier Tubes

Solid State Photon-Counters

Photon detectors. J. Va vra SLAC

A new Scintillating Fibre Tracker for LHCb experiment

Experimental Astrophysics Group, Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720

CAEN Tools for Discovery

Photodetector Testing Facilities at Nevis Labs & Barnard College. Reshmi Mukherjee Barnard College, Columbia University

PMT Gain & Resolution Measurements in High Magnetic Fields

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

The 20 inch MCP-PMT R&D in China

The hybrid photon detectors for the LHCb-RICH counters

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

High ResolutionCross Strip Anodes for Photon Counting detectors

HAPD and Electronics Updates

PID summary J. Va vra

Large photocathode 20-inch PMT testing methods for the JUNO experiment

SciFi A Large Scintillating Fibre Tracker for LHCb

Tests of Timing Properties of Silicon Photomultipliers

Focusing DIRC R&D. J. Va vra, SLAC

Table. J. Va vra,

MCP Upgrade: Transmission Line and Pore Importance

Production and Development status of MPPC

Development of an Abort Gap Monitor for High-Energy Proton Rings *

An extreme high resolution Timing Counter for the MEG Upgrade

Sensors for precision timing HEP

THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

Status of the CUORE Electronics and the LHCb RICH Upgrade photodetector chain

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Cathode Studies at FLASH: CW and Pulsed QE measurements

Investigation of time-of-flight PET detectors with depth encoding

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

Frontend Electronics for high-precision single photo-electron timing

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

itop (barrel PID) and endcap KLM G. Varner Jan-2011 Trigger/DAQ in Beijing

Updates on the Central TOF System for the CLAS12 detector

Status of the Timing Detector Plastic+SiPM Readout Option

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Application of Hamamatsu MPPC to T2K near neutrino detectors

Operation of CEBAF photoguns at average beam current > 1 ma

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

First evaluation of the prototype 19-modules camera for the Large Size Telescope of the CTA

Silicon PhotoMultiplier Kits

Large Area, High Speed Photo-detectors Readout

LHC Beam Instrumentation Further Discussion

Photonic Devices for Vehicle Evolution

Image Intensifier User Guide

New gas detectors for the PRISMA spectrometer focal plane

Review of photo-sensor R&D for future water Cherenkov detectors NNN10 Dec

Liquid Xenon Scintillation Detector with UV-SiPM Readout for MEG Upgrade

Enhanced quantum efficiency bialkali photo multiplier tubes

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

Performance and Radioactivity Measurements of the PMTs for the LUX and LZ Dark Matter Experiments

Sep 09, APPLICATION NOTE 1193 Electronic Displays Comparison

Ultrafast Inorganic Scintillator Based Front Imager for GHz Hard X-Ray Imaging

Imaging diagnostico in Sanità Stato attuale e prospettive

Beam test of the QMB6 calibration board and HBU0 prototype

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

The Time-of-Flight Detector for the ALICE experiment

ELECTRON OPTICS OF ST-X, ST-Y SERIES OF STREAK & FRAMING CAMERA TUBES

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Commissioning and Performance of the ATLAS Transition Radiation Tracker with High Energy Collisions at LHC

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

MPPC (multi-pixel photon counter)

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

Drift Tubes as Muon Detectors for ILC

Henry Frisch For the LAPPD Collaboration

arxiv: v1 [physics.ins-det] 1 Nov 2015

Comparison of SONY ILX511B CCD and Hamamatsu S10420 BT-CCD for VIS Spectroscopy

IMAGING GROUP. * With dual port readout at 16MHz/port Detector shown with a C-mount nose and lens, sold separately

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

A very brief review of recent SiPM developments

arxiv:hep-ex/ v1 27 Nov 2003

MPPC and MPPC module for precision measurement

Review Report of The SACLA Detector Meeting

Wavelength selective electro-optic flip-flop

Results of recent photocathode studies at FLASH. S. Lederer, S. Schreiber DESY. L. Monaco, D. Sertore, P. Michelato INFN Milano LASA

Psec-Resolution Time-of-Flight Detectors T979

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Photocathodes FLASH: Quantum Efficiency (QE)

News in Photodetectors

These are used for producing a narrow and sharply focus beam of electrons.

Report from the 2015 AHCAL beam test at the SPS. Katja Krüger CALICE Collaboration Meeting MPP Munich 10 September 2015

Introduction. An AFM/NSOM System with Fluorescence Lifetime Imaging. Application Note

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

Progress on the development of a detector mounted analog and digital readout system

Screen investigations for low energetic electron beams at PITZ

BUNCH-BY-BUNCH DIAGNOSTICS AT THE APS USING TIME- CORRELATED SINGLE-PHOTON COUNTING TECHNIQUES*

Photoinjector Laser Operation and Cathode Performance

R&D on high performance RPC for the ATLAS Phase-II upgrade

Transcription:

Lifetime of MCP-PMTs, Alexander Britting, Wolfgang Eyrich, Fred Uhlig (Universität Erlangen-Nürnberg) Motivation A few pros and cons of MCP-PMTs Approaches to increase lifetime Results of aging tests Outlook and summary 1

PANDA Detector at FAIR Endcap DIRC antiproton-annihilation at DArmstadt 3.5 m Barrel DIRC et e m o ctr t e p rd S magne a w For Dipole p er t e trom et c e t Sp magn e g Tar lenoid So r 12 m 20 MHz p-p annihilations All image planes inside 1-2 Tesla B-field 2 C.Schwarz, RICH 2010 Cassis 2

Challenges to Photon Sensors Good geometrical resolution over a large surface multi-pixel sensors with ~5x5 mm2 anodes (smaller for Endcap DIRC) Single photon detection inside B-field high gain (> 5*105) in up to 2 Tesla Time resolution for ToP and/or dispersion correction very good time resolution of <100 ps for single photons Few photons per track high detection efficiency η = QE * CE * GE [QE = quantum efficiency; CE = collection efficiency; GE = geometrical efficiency] low dark count rate Photon rates in the MHz regime high rate capability with rates up to MHz/cm2 long lifetime with integrated anode charge of 0.5 to 2 C/cm2/y 3

Sensor Candidates multi-anode photomultipliers (MaPMTs) ruled out by magnetic field Geiger-mode avalanche photo diodes (SiPMs) huge noise is very problematic radiation hardness unclear micro-channel plate photomultipliers (MCP-PMTs) preferred choice for PANDA DIRC but problems with rate capability and aging (mainly QE) In the year 2011 there was no suitable sensor for the PANDA DIRCs! 4

Gain inside B-Field B-field 10 μm pores sufficient at 2 T Φ PMT-axis PHOTONIS XP85112 (10 μm) gain versus tilt angle Φ Hamamatsu R10754 (10 μm) θ 5*105 Φ = tilt angle between B-field direction and PMT-axis θ = rotation angle of PMT around B-field direction 5*105 Gain loss at high B-fields and large Φ-angles 5

Single Photon Time Resolution Amplifier Ortec FTA820 (x200; 350 MHz) --- Discriminator Philips Scientific 705 BINP #73 6 μm 27 ps XP85011 25 μm 49 ps PHOTONIS XP85012 XP85013 25 μm 25 μm 37 ps 51 ps XP85112 10 μm 36 ps R10754 10 μm 32 ps Hamamatsu R10754X-L4 R10754X-M16 10 μm 10 μm 31 ps 33 ps time resolution of all MCP-PMTs 50 ps and better no dependence on the B-field 6

Gain and Crosstalk of R10754X-M16 gain variations of factor 3 even within the same pixel 50% level of crosstalk extends only little into adjacent pixel long tails in crosstalk are of electronic nature 7

Gain and Crosstalk of XP85112 substantial gain variations between pixels (in center!) 50% crosstalk level extends ~1 mm into adjacent pixel but no long crosstalk tails 8

Rate Estimates for PANDA rate capability and lifetime are the most critical issues for the application of MCP-PMTs in any high-rate experiment expected rates and anode charges of the PANDA DIRCs: total rate anode rate (after Q.E.) integrated anode integrated anode charge / year charge / 10 years [C/cm2/year] at 106 [C/cm2] at 106 gain gain (at 100% dc) (at 50% duty cycle) [MHz/cm2] [MHz/cm2] Barrel DIRC at end of radiator 60 5.6 28 at readout plane 1.7 0.2 1 Endcap DIRC at rim of radiator 19 2 10 focussing 7.5 0.8 4 5 20 Endcap DIRC with much higher photon rate than Barrel DIRC very challenging 9

Rate Capability most MCP-PMTs show stable operation to ~200-300 khz/cm 2 single photons (at gain 106) R10754X and XP85112 are suitable for both PANDA DIRCs 10

Lifetime-Investigated MCP-PMTs BINP PHOTONIS Hamamatsu XP85012 XP85112 XP85112 R10754X-01-M16 R10754X-07-M16M pore size (μm) 6 7 25 10 10 10 10 number of pixels 1 1 8x8 8x8 8x8 4x4 4x4 active area (mm²) 9² π 9² π 53x53 53x53 53x53 22x22 22x22 15.5² π 15.5² π 59x59 59x59 59x59 27.5x27.5 27.5x27.5 36 36 81 81 81 61 61 total area (mm²) geom. efficiency (%) photo cathode peak Q.E. multi-alkali 21% @ 495 nm 21% @ 495 nm 20% @ 380 nm 23% @ 380 nm multi-alkali 22% @ 380 nm better vacuum, better vacuum, better vacuum, better vacuum, new cathode polished surfaces polished surfaces ALD surfaces comments # of tubes measured bi-alkali 1 2 1 1 21% @ 375 nm 22% @ 415 nm protection layer further improved between MCPs lifetime (ALD?) 2 1 (+1 L4) 2 Tubes first measured with no significant lifetime improvements Lifetime improved tubes currently being measured or finished Measurement of tube just started or not yet included in setup 11

Lifetime of former MCP-PMTs Status ~2 year ago BINP with Al2O3 film at MCP entrance to stop feedback ions PHOTONIS with improved vacuum and electron scrubbing of surfaces Quantum efficiency reduced by 50% or more at <200 mc/cm2 By far not sufficient for PANDA 12

Approaches to Increase Lifetime Protection layer In front of first MCP layer (older BINP and Hamamatsu) disadvantage: reduction of collection efficiency Between MCP layers (new Hamamatsu) anode region is hermetically sealed from photo cathode region [NIM A629 (2011) 111] Improved vacuum + treatment of MCP surfaces [NIM A639 (2011) 148] Electron scrubbing (older PHOTONIS and new BINP) Atomic layer deposition (PHOTONIS) New photo cathode [JINST 6 C12026 (2011)] Na2KSb(Cs) + Cs3Sb (new BINP) disadvantage: significantly higher dark count rate 13

Aging of Several MCP-PMTs Problem: The few aging tests existing were done in very different environments results are rather difficult to compare Goal: measure aging behavior for all currently available lifetimeenhanced MCP-PMTs in same environment Simultaneous illumination with common light source same rate MCP-PMTs included in aging tests of last 2 years: 2x BINP improved vacuum and scrubbed surfaces + new photo cathode (one finished) 4x Hamamatsu R10754X L4 and M16: protection layer between 1st and 2nd MCP (both finished) 2x M16M: further counter measures against aging (ALD?) 2x PHOTONIS XP85112 ALD surfaces surface half covered during illumination 14

Measurement of MCP Lifetime Continuous illumination 460 nm LED at 0.25 to 1 MHz rate attenuated to single photon level 3 to 14 mc/cm2/day Positions of QE meas. Permanent monitoring MCP pulse heights and LED light intensity Q.E. measurements 300800 nm wavelength band with monochromator Δλ = 1 nm every few days: wavelength scan every several weeks: complete surface scan 15

Current Setup 16

Illumination Overview BINP Ha ma ma ts u R10754X Photonis XP85112 Integral charge Sensor ID (Sep. 2, 2013) [mc/cm2] Diff. charge (maximum) [mc/cm2/d] # of mea- # of QE surements scans Comments 9001223 5570 13.4 123 11 Start: 23 Aug. 11 ongoing 9001332 2261 14.1 27 3 Start: 12 Dec. 12 ongoing JT0117 (M16) JT0158 (L4) KT0001 (M16M) KT0002 (M16M) 2086 14.1 86 7 Start: 23 Aug. 11 Stop: 24 Jul. 12 649 6.3 83 8 Start: 23 Aug. 11 Stop: 6 Aug. 12 131 16.7 3 1 Start: 20 Aug. 13 ongoing 1359 3648 10.6 90 8 Start: 21 Oct. 11 Stop: 06 May 13 3548 4779 11.7 100 8 Start: 21 Oct. 11 ongoing not yet started 17

Gain vs. Integrated Anode Charge Only moderate gain changes This was different in the former MCP-PMTs! 18

Darkcount vs. Anode Charge Only few changes of darkcount rate for PHOTONIS XP85112 Big reduction in BINP and Hamamatsu R10754X 19

Quantum efficiency MCP-PMT Peak Q.E. (nm) Photo cathode XP85112/A1 HGL (1223) 390 bi-alkali R10754X-01-M16 375 multi-alkali R10754X-07-M16M 415 bi-alkali BINP 1359 495 Na2 KSb (Cs)+ Cs3 Sb BINP 3548 495 Na2 KSb (Cs)+ Cs3 Sb 08.09.09 Alexander Britting 20 20

Q.E. Scans (Hamamatsu R10754X-M16) 22 mm Q.E. measured at 372 nm 21

Q.E. Scans (BINP 3548) 18 mm Q.E. measured at 372 nm 22

Q.E. Scans (Photonis XP85112) Q.E. measured at 372 nm 51 mm 9001223 23

Q.E. Scans (scaled to MCP size) Ham. R10754X-M16 PHOTONIS XP85112 Q.E. measured at 372 nm BINP 3548 24

Q.E.(λ) vs. Integral Anode Charge Hamamatsu: Q.E. drops significantly above ~1 C/cm 2 PHOTONIS: if at all, only moderate Q.E. drop seen 25

Relative Q.E.(λ) vs. Anode Charge Ham. R10754X-M16: longer wavelengths drop faster than short ones BINP 3548 and PHOTONIS XP85112: no relative Q.E. degradation 26

Lifetime of Different MCP-PMTs older BINP and PHOTONIS MCP-PMTs: rapid Q.E. degradation new PHOTONIS XP85112: almost no Q.E. drop at 5.6 C/cm2 27

Accelarate Aging Measurements M.Yu. Barnyakov and A.V. Mironov, 2011 JINST 6 C12026 At 2nd MCP output QE degradation rate depends on count rate At 1st MCP no correlation between QE degradation and count rate 28

Estimate Lifetime from Afterpulsing How to guess MCP-lifetime before (and during) aging? Measure fraction of pulses (p.e.) followed by an afterpulse (ion) The higher the fraction of afterpulses the higher the amount of restgas inside tube Time delay spectrum may allow to guess the type of ions New MCP-PMT with ALD surfaces shows lowest afterpulsing. More statistics (= PMTs) needed! 29

Summary Latest MCP-PMT models fulfill most requirements of PANDA DIRC. Significant increase of lifetime of MCP-PMTs due to the recent improvements in design huge step forward! equipping the PANDA DIRCs with MCP-PMTs seems possible ALD technique appears very promising (reached ~6 C/cm2) Further improvements could possibly come from modified photo cathodes (see BINP) MCP materials with less outgassing (e.g., borsilicate glass instead of lead glass) 30

Microchannel-Plate PMT electron multiplication in glass capillaries ( 10-25 m) usable in high magnetic fields high gain: >106 with 2 MCP stages single photon sensitivity very fast time response: Channel ~400µm φ~10µm signal rise time = 0.3 1.0 ns TTS < 50 ps low dark count rate quantum efficiency comparable to that of standard vacuum PMTs multi-anode PMTs available caveats: lifetime (QE drops) price 31

Q.E.(λ) vs. Integral Anode Charge Hamamatsu: tube was damaged before illumination PHOTONIS: no Q.E. drop seen 32

Relative Q.E.(λ) vs. Anode Charge Ham. R10754X-L4: longer wavelengths drop faster than short ones BINP 1359 and PHOTONIS XP85112: no relative Q.E. degradation 33

Q.E. Scans (Photonis XP85112) Q.E. measured at 372 nm 51 mm 9001332 34

Q.E. Scans (Hamamatsu R10754X-M16M) 22 mm Q.E. measured at 372 nm 35