The Taal Inc. Rhythm Ensemble Tech Rider

Similar documents
Paradiso (ch. Václav Kuneš) (30min) Technical requirements / List of light equipment Focus sheet on demand - (standard focusing)

Get Funked Compact 6-piece. Technical Rider 2017/18. Contents Page 1/2 Technical Rider Page 3 Channel List Page 4 Monitor List Page 5 Stage Diagram

Little River Band Production Rider 2018

BITUSA 2019 General DRESSING ROOMS

SOUND TECH RIDER FIDO

Hard Rock Cafe Times Square Sound System Advance Sheet

Multi-Purpose Auditorium Sound Reinforcement System Design ECE Spring Zach Vander Missen Muhammad Farooq Garrett McMindes

Monolake Live Surround 2011/2012

US 2015/16 TECH RIDER

Malaviya National Institute of Technology Jaipur Jawahar Lal Nehru Marg, JAIPUR (Rajasthan)

HORACE X PERFORMANCE REQUIREMENTS (Technical)

SHOWBOX SODO TECHNICAL SPECIFICATIONS

TECHNICAL RIDER PA SYSTEM

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

Laura Turner Hall Overview. Sound System Overview

TECHNICAL RIDER SUPERVISION

Rider Part1: Technical Requirements, A Cappella Show

BLITZSCHLAG TH - 26 TH FEBURARY 2017

Corrigendum. Reference: Tender Notification No 87/NITK/DSW/INCI-19, Dated: 08/02/2019

A38 SHIP CONCERT HALL TECHNICAL RIDER 2018!

Dr JOHN GALLAGHER CONCERT CHAMBER

Merry Christmas Darling: Carpenters Christmas FULL RIDER 2018 (8-Piece BAND) (Updated March, 2018)

Section A: Front of House (FOH) Public Address (PA) Speaker System

technical rider version August 2015 People s Place Stadhouderskade ES Amsterdam

Ex-Hire Used Equipment Price List

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Rooming List. Catering & Meals. 10 Hands and 1 Piano TIMELINE SHOW WITH GUEST Tech Sheet

City of Villa Rica 2016 Sound and Lighting. THE MILL amphitheater

Mics, DIs, Stands, and Cables

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Ex-Hire Used Equipment Price List

Barbican Concert Hall Sound System Spec

Lights. Carlos Leyva Cel: (619) (52)(664) Audio

TECHNICAL REQUIREMENTS

Technical Rider "THEATRE" by SUPERAMAS

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Meadow Brook Music Festival 3554 Walton Blvd Rochester Hills, MI Tech Pack

National Theater_sound

Artist: Michael and Amy

REQUEST FOR QUOTE SOUND & LIGHTING for Volunteer Awards Banquet and July 3 rd Fireworks. PROPOSAL NUMBER: Q17-001PR ISSUE DATE: February 1, 2017

SUSAN AGLUKARK. Keynote Speaker/ Solo Presentation TECHNICAL RIDER HOSPITALITY RIDER 2018 Revision 1/15/18 KEY CONTACT:

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Les Docks / Av. de Sévelin Lausanne. Technical Rider

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Digital Effects Manual

PRODUCTION BIBLE. last update November 2015

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

FASO DANCE COMPANY KALAKUTA REPUBLIK

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

The Willoughby Brothers

GENERAL INFORMATION CONTACT DETAILS. Venue Booker: Shaun Adams E: P: (03)

Main Hall. Left side of the building. Ramp available. *elevator available (1,4m x 3,3m)

GENERAL INFO. GENERAL ADMISSION: 1427 TOTAL 1058 main floor, 90 mezzanine, 279 balcony. SEATED: 1145 TOTAL 776 main floor, 90 mezzanine, 279 balcony

Les Docks / Av. de Sévelin Lausanne. Technical Rider. Technical Rider Docks, updated

UNIVERSITY CONCERT HALL. Technical Specification

Complete guide Compiled January 2014

111 North 5 th Street Minneapolis, MN 55403

Main Stage Technical Specs - Hall #2

CONTENTS. CONTACT DETAILS. FINDING US. VENUE INFORMATION. TECHNICAL INFORMATION. ROOM DIAGRAMS.

Not Fade Away. The Ultimate Buddy Holly Experience. TECHNICAL RIDER Video Projection is Recommended

Technical Rider. GöteborgsOperans Danskompani. Spirit Tour to XX DATE to DATE. Table of Contents: 1. The Company

Z SPACE Technical Specifications. Stage & Rigging

Technical Rider Vocal Point Season Performing Arts Management

MAJESTIC (Circus Tent)

ETIENNE CHARLES CALYPSO REVIEW

East Hampton Studio THE HAMPTONS LARGEST VENUE.

Thank you for thinking of The Fonda Theatre for your private event!

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

v. 2.4 Address: Musikhuset Posten Østre Stationsvej 35 DK-5000 Odense C Booking/management: Morten Østlund

Technical Informa on.zack Theater

YAAM Berlin Venue Specifications & Technical Rider. Effective April 2018 Availability, errors and specifications subject to change without notice!

La Gravière/ Chemin de la Gravière 9, 1227 Genève. Technical Rider. Updated 21/10/15

Technical Specification

Quick-Advance Fact Sheet

Technical Specifications

Technical Specifications

VENUE SPECS Channel Music GmbH. 2 Floor Plan. Falckensteinstr Black Room Berlin. 8 Blue Room. 12 Venue Info

AUDIO, LIGHTING & VIDEO DISPLAY SYSTEMS SPECIFICATIONS

mainstage or theatercafe, on demand on demand 103 dba at FOH 6x4x1 meter (if needed bigger) + stairs Max. 4x drumriser (2x1x0,5 meter) No Yes

Technical Services and Specification

SHORT TENDER NOTICE LIGHT SOUND AND FURNITURE COMMITTEE SPICMACAY INTCON 2018

Patriots Theater at the War Memorial Technical Data

Technical Specifications

Tickets will be sold through our ABC account and all tickets are scannable on entry.

Turkuaz Hospitality & Production Rider General Terms: Security- Taping and Cameras ARE allowed.

Sound Equipment Sound Control Room

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

TECHNICAL SPECIFICATION

BLACK VIOLIN. Hospitality Requirements. One large master or star dressing room equipped as follows:

Ed Blackwell Production Manager Mike Weller Head of Music

Treefort Music Fest- March Festival Information Main Stage

Ex-Hire Used Equipment Price List

SECREST AUDITORIUM TECHNICAL PACKAGE

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Technical Specifications

Roberto SOLO Fonseca

Bloomington Center for the Performing Arts. Technical Specifications

Technical Specification (Studio Theatre)

Everyness. Wang Ramirez Company TECHNICAL RIDER

Atlanta Audio Services Information Sheet

Transcription:

The Taal Inc. Rhythm Ensemble Tech Rider In case of any queries regarding sound please contact Janak on +91 9595 680 886 Email: janak@taalinc.net Please go through the full technical rider (including the stage plot) and if necessary have a print out of same. 1. PA System: The PA should be at least a 3-way Line Array System. a. The PA should be setup by the vendor depending on the venue, location and acoustics. b. The PA should be capable of about 115 db SPL at FOH with headroom for a bit more. c. The PA Subs (Subwoofer) should be routed on a separate Aux. d. Acceptable brands of PA are a. Martin Audio, b. Meyer Sound, c. L Acoustics, d. Nexo, D&B,EAW, e. D.A.S. Aero Series and f. JBL Vertec Series. e. In case the above brands are not available, please consult the band engineer about the same. f. The system should be setup, Line Check done, tuned & aligned (with removing all the feedbacks from FOH as well as the monitors) and ready by the time the band reaches the venue.

2. FOH Console: A Digital Console with the following features is to be provided. Please do not substitute with an Analog Console. 1. Minimum 4 internal FX Processors. 2. 8 VCA groups+8 Audio groups. 3. 16 Aux Buses. 4. 31 band graphic equalizer for all outputs The following are suitable in order of preference: 5. Digidesign D Show/ Profile/ SC 48 6. Yamaha QL 5, Yamaha CL 5, Yamaha M7CL. If the above are not available please inform us well in advance as to what equipment is available. Please refrain from providing smaller digital console. 3. Monitor Requirements: a. 6 wedges monitors on 1 aux sends for each of the band members. b. 1 pair of side fills with subwoofers on two separate mixes placed on either side of the stage is required. (Must) c. 2 sets of In Ear Monitors must ( Shure PSM 1000/ 900 or Sennheiser ew 300) d. Note: Please make sure all wedges are of the same make and model and all the wedges should be 15 2- Way ACTIVE/ PASSIVE. No mixing and matching please. e. Preferred brands are EAW MW15 Series, EAW LA215 Series, Martin Audio LE 1500S, Martin Audio LE 2100S, NEXO PS15 R2 Series, JBL VRX915M Series, D.A.S. Avant Series ONLY.

4. OTHER REQUIREMENTS: a. 2* Music/Lyrics notation stand. b. 2-3 Power Points at Different places on Stage ( Indian Style) 5. SOUND GEAR: 1) Mic/Input Requirements: Microphones/ Lines Sr Microphone Stand Quantity 1 Shure B52 Medium 1 2 SM 58 Short 4 3 SM 58 Tall 4 4 SM 57 Short 3 5 Flute Mic - 1 6 Wireless Headset Mic (Shure) - 1 7 Wireless Clip on Condenser ATM 350-1

Channel Stands Aux no. 6. CONSOLE I/O: a. Channel assignment. Artis t Instrument Processing Mic/DI 1 01 Sangban Comp / Gate SM 58 Short 2 02 Kenkeni Comp / Gate SM 58 Short 3 03 Dununba Comp / Gate Shure B52 Medium 4 04 Flute Comp / Gate Flute Condenser - 5 05 Vocal 1 Comp SM 58 Tall 6 06 Vocal 2 Comp SM58 Tall 7 07 Djembe 1 Comp / Gate ATM 350 Clip on Condenser - 8 08 Vocal Comp SM 58 Tall 9 09 Djembe 2 Comp / Gate SM 58 Short 10 010 Djembe 3 Comp / Gate SM 58 Short 11 011 Vocal 3 Comp SM 58 Tall 12 012 Vocal Comp Shure wireless headset -

b) Auxiliaries: Aux Send Processing Remarks Return No of Wedges 01 Graphic EQ Front 4--6 02 Graphic EQ Side fill Left As Mentioned 03 Graphic EQ Side fill Right As Mentioned 04 Graphic EQ 05 Graphic EQ 06 Graphic EQ 07 Graphic EQ 08 Graphic EQ 09 Graphic EQ 10 Graphic EQ 11 Graphic EQ 12 Graphic EQ

NOTE : a. The Stage size should be at least L*D*H 24ft*18ft*3ft.(for indoor venues) b. The Stage size should be at least L*D*H 30ft*24ft*6ft. (for outdoor venues) c. Please call Sound Engineer if the Stage size is less than the above mentioned specification d. Please use a separate generator for sound system and lights system. e. The Band will take minimum of 2.5 hrs for Sound Check, after the system is fully functional n patched (as per mentioned in the Tech Rider) by the sound vendor. f. The Mixing Console should be placed at centre of the Venue (ideally) a. if not it should be on one side of the venue b. ** In no case it will be ACCEPTED next to the PERFORMANCE STAGE. g. Please Carry Mic/ Line Snake Accordingly h. A Riser / Platform of 8ft*8ft*2ft (L*B*H) should be there for the Mixing Console. i. The Stage Area and Mixer Console Area should be properly covered against Sun, Rain etc j. The Monitors, Stage Gear should not be moved/changed from their position after the SOUND CHECK is done.

Ref Channel Ref Channel No. No Mic Stands No No Mic Stands 1 01 SM 58 Short 9 09 SM 58 Short 2 02 SM 58 Short 10 10 SM 58 Short 3 03 Shure B52 Medium 11 011 SM 58 Tall 4 04 Flute Condenser - 12 012 Shure wireless headset - 5 05 SM 58 Tall 15 015 - - 6 06 SM58 Tall 16 016 - - 7 07 ATM 350 Clip on Condenser - 17 017 - - 8 08 SM 58 Tall 18 018 - -

7. Lighting Requirement: Conventional Lighting list Par 64 (wide) 22 nos. Halogen lights 1 kw 08 nos. Molfay 4 cell blinders 02 nos. Haze machine with blowers 02 nos. Jumbo smoke machine 3000 02 nos. Avolite pearl 2010 01 no. Experienced Light Designer / Engineer Automated Lighting 5R or 15 R sharpy 18 nos. LED par 3 watts ROBE 6 chanel 32 nos. Trussing Box trussing of branded make Size W 14met x D 11met x H 8met. (46 x 36 x 27 feet approx.) Please follow the drawing. Other requirements. Total 4 nos. Clear com s. 1 clear Com stage left, 2 clear coms (front of house. On console)