Manual PCE-830 power anlayser

Similar documents
User Manual Power and Harmonics Analyzer Model PQ3350

User Manual. Power and Harmonics Analyzer Model PQ3350

Certificate of Calibration

Clamp 200 A AC/DC (+ V AC/DC + Ω)

ISO-TECH IPM3005 Flexible AC Power Quality Tester Instruction Manual

DGC-1000A CLAMP-ON GROUND RESISTANCE TESTER

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

INSTRUCTION MANUAL POWER QUALITY ANALYZER

PQ-Box 100 Quick Start Instructions

multi-function meters

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Fluke 430 Series Three-Phase Power Quality Analyzers

APPLICATION NOTE # Monitoring DTMF Digits Transmitted by a Phone

Spectra Batten (Order code: LEDJ95)

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

PowerMonic. FAQs [2/12]

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

OWL micro+ WIRELESS ELECTRICITY MONITOR

Digital Real Time Recording VCR

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

DTL-4800P. Digital Real Time Recording VCR

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

Good Display Specifications

Operating Instructions

POWER MONITORS ENERIUM RANGE. Minimize your energy consumption and optimize your installation

Experiment 9 Analog/Digital Conversion

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

LM16X21A Dot Matrix LCD Unit

Professional Fidelity Mastering Grade Listening

POWERSCOUT SERIES FEATURES NETWORKED POWER METERS HIGH PERFORMANCE INSTRUMENTS FOR ENERGY MEASUREMENT

Fluke 430 Series Three-Phase Power Quality Analyzers

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION SECTION 16901

# Voltage Performance Monitor Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.

Multifunction Digital Timer

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Aurora Grid-Tie Installation Instructions (Model Number: PVI-3.0-OUTD-US-W) Revision 4.1

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

LAN Network Tester. Operating Manual. Part No TRIAX - your ultimate connection

We ve got the best technology to fit your power monitoring needs. Scenario works on all!

Spectra Flood Q40. Exterior Fixture User Manual. Order code: LEDJ Version LEDJ284N - 15 Version

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

MachineryMate 800 operating guide Handheld vibration meter

RIGOL. Quick Guide DSA800E. DSA800E Series Spectrum Analyzer RIGOL TECHNOLOGIES, INC. All Rights Reserved.

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Fluke 434-II/435-II/437-II

ex 800 Series ematrix System

LCD MODULE SPECIFICATION

SM-10 SAT Level Meter User s Manual

FD Trinitron Colour Television

CUSTOMER: P/N: 802C Y-YG

SC26 Magnetic Field Cancelling System

Ecomind Electricity Monitor Kit EM422EM-E-KBTS EM422EM-E-KMTS. Installation Instructions

FEATURES. Measurement and Verifi cation (M&V) Studies Electrical Load Profi ling Energy Audits New Technology Assessment Studies

Standard RS232 RS ma

Noise Detector ND-1 Operating Manual

FXL8 Pro effects looper. user manual

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

Instructions. P MHz 1X/10X Passive Probe

EDMI Mk 7C Electricity Meter User Guide to LCD Screen Displays

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

192 Channel DMX Controller

Calibration Information

ScopeMeter 190 Series Specifications

WELDING CONTROL UNIT: TE 450 USER MANUAL

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

IQ Analyzer 6400/6600 Series. Cutler-Hammer Power Management Products High End Metering Capabilities

Professional Power Amplifier Specifications...8 SPECIFICATION

1CHDVRD1 USER MANUAL. These instructions apply to unit model 1CHDVRD1 only. Please read carefully before use.

DH7-DK QUICKSTART GUIDE. DH7 4K Support HDMI On-Camera Field Monitor Deluxe Kit

LA-1440 and LA-4440 Sound Level Meter

CrossLine Generator Operation Manual

LED Driver Linear / area fixed output

Full Disclosure Monitoring

Active UTP Transceiver Hub Installation Guide

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

USER S GUIDE. 1 Description PROGRAMMABLE 3-RELAY LOGIC MODULE

Advanced Test Equipment Rentals ATEC (2832)

Simply clever! The digital DIN-rail time switches by Grässlin

LED Driver Compact fixed output

ASNT_PRBS20B_1 18Gbps PRBS7/15 Generator Featuring Jitter Insertion, Selectable Sync, and Output Amplitude Control

PA9PLUS Portable Power Quality Analyzer

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Model P2016. Dual Channel Handheld Digital Storage. Oscilloscope & Multimeter. Quick Scope Guide

Trusted 40 Channel 120 Vac Digital Input FTA

"shell" digital storage oscilloscope (Beta)

Provides an activation of Relay 1 triggered by Input 1. The function also provides an option for reverse-logic on the activation of Input 1.

VXF7 QUICKSTART GUIDE. 7" 4K Full HD HDMI/3G-SDI On-Camera Monitor

HOME GUARD USER MANUAL

PRINCIPLES AND APPLICATIONS

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LED Driver Compact dimming

HD-CM HORIZON DIGITAL CABLE METER

Transcription:

www.pce-indsutrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ Manual PCE-830 power anlayser

1. Definition of Symbols: Caution n: Refer to Acc companying Documents Double Insulation Caution: Risk of Elec ctric Shock 2. Over-voltage category III (CAT III): equipment in fixed installations. WARNING: If the power analyzer is used in a manner Not specified by the manuf acturer, the protection Prov ided by the clamp me ter m ay be impaired. 3. Please read the following instructions before usage 1. Do not operate in wet or dusty environments. 2. Do not operate in presence of combustible or explosive gas 3. Do not touch exposed metal part ts, unused terminals. 4. Cons sider the use of rubber glove in operation. 5. Do not operate in excess of AC 500V (Phase to Neutral), or AC 600V (Phase to Phase) 1. Do not operate when the unit seems to be mal-functioning 4. Don t use the flexiblee current probe before you read the following instructions. 1. Don t install the flex xible current probe around bare conductors carrying a voltage from 30V to 600V unless you are wearing protective clothing and glove suitable for high-voltag e work. 2. Always inspect and check any damage of the current probe assembly before usage. Don t use the flexible current probe if any damage is found. 3. Don t use the flexible current prob be on circuit rated higher than 600V in installation category III. 2

5. FEATURES Analysis for 3P4W, 3P3W, 1P2W, 1P3W True RMS value (V123 and I123) Active Power (W, KW, MW, GW) Apparent and Reactive Power (KVA, KVAR) Power Factor (PF), Phase Angle (Φ) Energy (WH, KWH, KVARH, PFH) Current measurement from 0.1mA to 1000A, capable of analyzing IT standby power consumption to the maximum demand of a factory Display of 35 Parameters in One Screen (3P4W) Programmable CT (1 to 600) and PT (1 to 3000) Ratios Display of Overlapped Voltage and Current Waveform Average Demand (AD in W, KW, MW) Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period Harmonic Analysis to the 99 th Order Display of 50 Harmonics in one Screen with Waveform Display of Waveform with Peak Values (1024 Samples / Period) Analysis of Total Harmonic Distortion (THD-F) Graphic Phasor Diagram with 3 Phase System Parameters Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%) DIP, SWELL, and OUTAGE are included in transient events. 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR) 3 Phase Voltage or Current Unbalance Factor (d0%, d2%) Calculated Unbalanced Current through Neutral Line (In) 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system) Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Optical Isolated RS-232C to USB Interface Built-in timer and calendar for data logging Option: 300XP Portable Thermal Printer 3

6. PANEL DESCRIPTION 4

1. Input Terminal for Neutral Line (Voltage) 2. Voltage Input Terminals for Each Phase (V1, V2, V3) 3. External DC Input (The AC adaptor must be 600V isolated) 4. Current Input Terminals for Each Phase (I1, I2, I3) 5. LCD Display 6. Buttons 7. RS-232C Window 8. Stand Holder 9. Stand 10. Battery Cover 11. Battery Compartment 5

Press this button to exit transient detection or to exit SETUP menu. Press this button to perform transient detection. Press this button to hold the data displayedd in LCD. Press this button and then REC button to record the displayed data. Press HOLD button again to continu ue operation. Press this button to start measurement of harmonics in magnitude. Press this button to select V1, I1, V2, I2, V3, or I3 for harmonics analysis Press this button for the volta age or current input range Press this button to enter SETUP mode and then select the parameter r to be adjuste ed Press this button to increme ent value by one. Hold the button for two seconds or more to speed up the increm ent. Press this butt ton to decrement value by one. Hold the button for two seconds or more to speed up the 6

increment. In the mode of harmon ic analysis, pre ess this button to move the cursor left to the previous order. In the mode of harmon ic analysis, pre ess this button to move the cursor right to the previous order. Press this button to sta rt data logging. Press it again to stop data logging. The sampling interval is displayedd in LCD pointed by SEC indicator. In the mode of power measurement, press this button to display the phasor diagram. In the mode of harmonic anal lysis, press this button to display phase angle instead of magnitude. Press this button to turn the back light on. Press it again to turn the back light off. Press this button to star rt measureme ent of power parameters. Press thi s button to display waveform of voltage and current. Press this button to display waveform of voltage only In the mode of power parameter measurement, press this button to select appropriate system (3P4W, 3P3W, 1P2W or 1P3W). In the mode of displaying waveform, press this button to select (V1, I1), (V2, I2), or (V3, I3). Press this button to turn the power on or off. 7. 6801 Current Probe (100A) 1. Jaw Assembly 2. Trigger 3. Range Selector 4. 6 pin mini DIN connector 7

NOTE: To setup 100 A current probe as selected probe, press the SETUP bottom to select CLAMP. When the CLAMP is reverse video, press the or button to select 100. 8. 6802 Current Probe (1000A) 1. Jaw Assembly 2. Trigger 3. Range Selector 4. 6 pin mini DIN connector NOTE: To setu p 1000A current probe as selected probe, press the SETUP button to select CLAMP. When the CLA AMP is reversee video, press s the or button to select 1000 9. 3007 Current Probe (3000A) 1. Coupling Assembly 2. Flexible Loop 3. Mini- -DIN connector for Output 4. Output Range Select Switch 8

NOTE: To setup 3000A current probe as selected probe, press the SETUP button to select CLAMP. When the CLA AMP is reversee video, press the or button to sele ect 3000. 10. OPERATING INSTRUCTIONS NOTE: Select the correct CLAMP in the SETUP menu. When the current probe is connected to the power analyzer, power analyzer will automatically detect the rang ge selected. NOTE: Select the correct frequency (Hz) in the SETUP menu. WARNING: All the curren nt probes connected to the power ana alyzer must be of the same model and same range. Mixed models and different ranges selected will cause incorre rect result of measurement. NOTE: Please pay special attention to the flex xible current probes (model 3007) conn nected to the power analyzer. 1. 2. 3. Connect the flexible probe around the conductor. Make sure the current flowing direction is in consistent with the arrow marked on the probe coupling. If the flexible current probe is connected in the right orienta a- tion, the correct phase will be displayedd in the oscilloscope. Keep the probe coupling more than 25mm away from the conductor. WARNING: Always wear appropriate gloves in operation. 9

11. Set up before operation a) Press SETUP button to enter setup screen. Press SETUP again to select the item for setting (the selected item will be displayed in reverse video). b) After selecting the item, press or buttons to set up its value. c) After finishing setting up, press EXIT button to leave setup mode. 1. Select the data for download: H means harmonics; H in reverse video means HOLD screen data (if the data is the one you want, you can press HOLD button to display the data, and press HOLD button again to exit); P means power data which can be a reference for downloading, the data in order is 0~84. 2. Shows the total logged data in the analyzer: max. 85 logging data. 3. REC DATE: shows the starting logging time of the 1st downloaded file. 4. Hz: set up the frequency (50, 60 or AUTO) of the system. 5. PT: set up PT value. 6. CT: set up CT value. 7. SEC: set up the interval seconds of logged data. 8. CLAMP: set up the clamps selected (100A, 1000A or 3000A). 9. MD TIME: set up the time of Maximum Demand (1~60 minutes). 10. TRANS REF: set up the transient voltage (which will be automatically changed in accordance with PT). 11. SDVP: set up upper and lower limits % of transient voltage detection. 12. YEAR: Set up year of calendar clock. 13. MONTH: Set up month of calendar clock. 14. DATE: Set up date of calendar clock. 15. HOUR: Set up hour of calendar clock. 16. MINUTE: Set up minute of calendar clock. 17. SECOND: Second can be displayed only (it can not be adjusted). 10

iinfo@tursdaletecchnicalservices.coo.uk 12. Powerr Quality of o a 3 Phas se 4 Wire (3P4W) ( Sy ystem 3 4W a) Turn the powe er on. Press th he POWER an nd the 1Φ3Φ buttons to sele ect the 3P4W system. The type t of system m will be displayyed at the left bottom b corner in the LCD. b) Connect the four fo test leads to the voltage e terminals V1,, V2, V3 and th he VN (Neutra al) of the syste em. c) Connect the test t leads to L1 1, L2, and L3 of o the 3P4W system. s d) Connect the three t current probes p to the power p analyze er input termina al I1, I2, and I3 3. e) Clamp on to the t L1, L2, and d L3 of the 3P4 4W system. Make sure the e current flow ffrom the front of the current probe to the back b of it. f) All parameters rs of the system m will be show wn in LCD. For the meaning of each pa arameter, referr to XIV. NOM MENCLATURE E. 11

13. Power Quality of a 3 Phase 3 Wire (3P3W) Syste 3 3W a) b) c) d) e) Turn the powe er on. Press the POWER and the 1Φ3Φ Φ buttons to select the 3P3W system. The type of system will be display yed at the bottom right of the LCD. Connect the four test leads to the voltage terminals L1, L2, and L3 of the system. Connect the three current probes to the power analyze er input terminal I1, I2, and I3. Clamp on to the L1, L2, and L3. Make sure the current flow from the front of the current probe to the back of it. All parametersrs of the system will be shown in LCD For the meaning of each parameter, refer to XIV. NOMENCLATURE. 12

In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)." 13