Data Communication Products

Similar documents
About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

GenSPEED Category 5e Cables 3

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

Detailed Specifications & Technical Data

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

Combining Value and Performance Like No One Else

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

Mohawk Master Catalog

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Detailed Specifications & Technical Data

CATEGORY 6 CABLING SOLUTIONS

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

PREMIUM 5e F/UTP PRODUCTS

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

STRUCTURED CABLING SYSTEMS (SCS)

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

PATCH CORDS, PLUGS & CABLES

Detailed Specifications & Technical Data

TABLE Of CONTENTS JACKET COLOR OPTIONS TABLE OF CONTENTS COMPANY INFORMATION CATEGORY 5E CABLES CATEGORY 6 CABLES CATEGORY 6A CABLES

Detailed Specifications & Technical Data

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

ACOM General Cable General Cable Canada

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

Volition TM Category 5e cable 100 Ω, FTP

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

Detailed Specifications & Technical Data

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

Table of Contents. Open Matrix System (OMS) 1-2

Category 5e F/UTP Euroclass D ca Cables

Detailed Specifications & Technical Data

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

CATEGORY 5e CABLING SOLUTIONS

SHIELDED DIGITAL CABLES (1249C SERIES)

1 1/2 13.5, 625 JCASS)

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

System List. Structured Cabling System. In-Building RF Solution. Shield/Unshield 4pr Cable. Patch Panel. Multi-pair Cable. Patch Cord.

Compact Module. Category 6 FTP Cabling System

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

UNIVERSITY of NORTH DAKOTA LOW VOLTAGE COMMUNICATIONS STANDARDS FOR CABLING, PATHWAYS, AND SPACE

Copper Solution Contents Cabinets Fiber Optic Solution

SECTION COMMUNICATIONS HORIZONTAL CABLING

3M Supported Applications Map 100,000 (2005) Single-mode. Fiber. Multimode. Fiber. Copper

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Multi-Media Installation Guide

Category 6A UTP cables shall be tested and proved to conform to TIA-568-C.2 standards.

How Wire Fails Originally presented to the Society of Motion Picture and Television Engineers Convention, Sydney, Australia, on Friday, July 4, 1997.

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Finding List by Question by State

VERICOM GLOBAL SOLUTIONS Knoxville, Tennessee

Magic Patch Patch Leads & Accessories

ENTERPRISE COPPER SOLUTIONS

DINTEK LAN Cabling Systems

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

STRUCTURED CABLING SOLUTIONS

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

75 Ohm BNC Male Connector Crimp/Solder Attachment for PE-B159, 1855A, Mini 59

What really changes with Category 6

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project

ULTIMATE SNAP-N-SEAL

LITWARRANTY Rev. 5 W a r r a n t y P r o g r a m S t r u c t u r e d C a b l i n g S y s t e m s

Structured Cabling System. Leading Solution

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

LAN Cabling Systems Copper

Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

SECTION TESTING OF COPPER CABLES

KACO-display. Wireless Solar Monitoring System. Operating Instructions KACO-display. full of energy...

CAT5E NETWORK PATCH LEADS

1x4, 1x8, 1x12, 1x16 VGA Extender / Splitter over Single CAT5

Cat.6 4 Pair UTP Cable

Gear up for the future.

384A Adapter Installation Instructions

VGA & Audio Receiver SET over Single CAT5 with RGB Delay Control

5O years of innovation and leadership.

25Years. System Warranty

CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

ENGINEERING COMMITTEE Interface Practices Subcommittee. ANSI/SCTE (Formerly IPS SP 001)

OXYFUEL. [Mk.I/II] AD COPY + SPECIFICATIONS Er / 75Z

CUSTOM COLLECTION. Welcome to the Tributaries Custom Collection.

Finding List by Question by State *


4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

PoE Over Coax Extender Kit

FUTURE PROOF YOUR CONNECTIONS

VGA, Audio & RS232 Extender SET over Single CAT5 with RGB Delay Control & IR Pass Through

BTNS TM. FTP Compact Module

Premise Installation Guide

SECTION 7 -- CROSS-CONNECT SYSTEMS

4, 8, 16 Port VGA/ Audio Extender / Splitter With Local Output with SPDIF Model #: VGA-C5SP-8

CUSTOM-LENGTH PATCH CABLES CUT-TO-LENGTH BULK FIBER PRE-TERMINATED FIBER MULTI-COLORED FIBER

Transcription:

Data Communication Products Premises Copper

Table of Contents Premises Category cables Category 6A 650MHz UTP Cable... 2 Category 6A 650MHz FTP Cable... 4 Category 6+ 550MHz UTP Cable... 6 Category 6+ 550MHz FTP Cable... 8 Category 6 500MHz UTP Cable... 10 Category 5e 350MHz UTP Cable... 12 RG cables RG6 Coax Cable... 14 Category Cable Part Number Key - - A B C D E F U Unshielded Twisted Pair A Cable Type F Foiled Twisted Pair 5350 Category 5e 350MHz 6500 Category 6 500MHz B Category 6550 Category 6+ 550MHz 6A650 Category 6A 650MHz C Pair Count 004 4-Pair P Plenum D Listing R Riser BL Blue WH White GY Grey BK Black E Jacket Color YL Yellow GN Green RD Red OR Orange VI Violet 1 Reelex I 2 Reelex II F Package Type 3 Reel In a Box 4 Reel RG6 Cable Part Number Index - - - - A B C D E F G A Cable Type RG6 S (60%) B Shield Q Quad C Conductor Material S CCS M CM D Listing R CMR E Jacket Color F Appendix Optional G Packaging Type 2 Reelex WH White BK Black e.g. RG6Q-S-RBK-2 RG6 Quad Cable, CCS Conductor Riser, Black, Reelex Box 1

Category 6A 650MHz UTP Cable U6A650-004-xxxx Riser Conductor Insulation (HDPE/FEP) Rip Cord (Optional) Twisted Pair Jacket (PVC) Conductor Insulation (HDPE/FEP) Rip Cord (Optional) Twisted Pair Jacket (PVC) Plenum UL Listed CMR and CMP UL Verified Capable of handling full broadband and baseband video signals Tight balance requirements improve cable performance Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) RoHS compliant Application Horizontal Distribution & Backbone Cabling 155Mbps ATM, 100Mbps TP-PMD 10/100/1000/10GBASE-T (IEEE 802.3) ISDN, ADSL ATM LAN 1.2G PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3 & 4) Part Numbers Jacket Color Category 6A UTP Cable, 4-Pair, Riser Rated Category 6A UTP Cable, 4-Pair, Plenum Rated Blue U6A650-004-RBL4 U6A650-004-PBL4 White U6A650-004-RWH4 U6A650-004-PWH4 Grey U6A650-004-RGY4 U6A650-004-PGY4 Black U6A650-004-RBK4 U6A650-004-PBK4 Yellow U6A650-004-RYL4 U6A650-004-PYL4 Green U6A650-004-RGN4 U6A650-004-PGN4 Red U6A650-004-RRD4 U6A650-004-PRD4 Orange U6A650-004-ROR4 U6A650-004-POR4 Violet U6A650-004-RVI4 U6A650-004-PVI4 2

Performance Characteristics Meet or exceed Category 6A requirements Frequency¹ Return Loss (RL) Minimum U6A650-R U6A650-P Insertion Loss (Attenuation) Maximum U6A650-R U6A650-P 1 20.0 37.27 41.08 2.1 1.78 1.62 4 23.0 33.71 31.43 3.8 3.46 3.18 10 25.0 36.72 33.12 5.9 5.62 5.19 16 25.0 37.27 34.04 7.5 7.14 6.60 20 25.0 37.81 34.91 8.4 8.00 7.43 31.25 23.6 40.45 37.59 10.5 10.04 9.36 62.5 21.5 39.91 37.55 15.0 14.47 13.68 100 20.1 39.33 36.52 19.1 18.41 17.61 200 18.0 38.02 36.14 27.6 26.44 25.91 250 17.3 36.34 35.71 31.1 29.55 29.19 300 16.8 34.97 33.50 34.3 33.13 32.60 400 15.9 34.27 32.27 40.1 37.71 38.01 500 15.2 34.08 31.56 45.3 42.53 43.27 600 30.00 28.00 47.00 47.00 650 30.00 49.00 49.00 Frequency¹ Near End Cross Talk (NEXT) Minimum U6A550-R U6A550-P Equal Level Far End Cross Talk (ELFEXT) Minimum U6A650-R U6A650-P 1 74.3 89.37 88.21 67.8 88.93 88.19 4 65.3 83.69 82.63 55.8 83.49 83.83 10 59.3 81.90 74.19 47.8 82.35 77.18 16 56.2 75.24 73.86 43.7 77.09 74.12 20 54.8 72.85 73.24 41.8 72.19 71.22 31.25 51.9 67.22 67.10 37.9 68.05 63.13 62.5 47.4 62.60 63.26 31.9 63.08 62.93 100 44.3 61.45 58.33 27.8 58.99 56.97 200 39.8 54.77 53.27 21.8 56.08 55.22 250 38.3 54.73 53.00 19.8 54.81 54.90 300 37.1 53.36 52.54 18.3 54.53 48.22 400 35.3 47.48 50.50 15.8 53.51 47.49 500 33.8 46.25 45.81 13.8 42.66 43.99 600 45.00 45.00 42.00 42.00 650 45.00 45.00 41.50 41.50 ¹Value above 550Mhz are for informational purposes only Technical Details Item Unit Riser Plenum Conductor DC Resistance Max. Ohms/100 m 9.38 9.38 Resistance Unbalance Max. % 5 5 Mutual Capacitance Max. nf/100 m 5.6 5.6 Capacitance Unbalance Max. pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay Max. ns/100 m 535 @ 650MHz 535 @ 650MHz Delay Skew Max. ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reel Reel Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65) Packages Per Pallet 12 12 Conductors 23 AWG, Solid copper 23 AWG, Solid copper Materials: Insulation in (mm) 0.045 (1.15), HDPE 0.041 (1.05), FEP Jacket in (mm) 0.331 (8.4), PVC 0.334 (8.5), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance Balanced Twisted-Pair Telecommunications Cabling and Components s 3

Category 6A 650MHz FTP Cable F6A650-004-xxxx Conductor Insulation (HDPE/FEP) Drain Wire Twisted Pair Aluminum Tape Jacket (PVC) UL Listed and Verified Capable of handling full broadband and baseband video signals Tight balance requirements improve cable performance Superior RFI, EMI and alien crosstalk performance by shield technology Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) Slim Cable Diameter of 0.283 in. (7.2 mm) RoHS compliant Application Horizontal Distribution & Backbone Cabling 155Mbps ATM, 100Mbps TP-PMD 10/100/1000/10GBASE-T (IEEE 802.3) ISDN, ADSL ATM LAN 1.2G PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3 & 4) Part Numbers Jacket Color Category 6A FTP Cable, 4-Pair, Riser Rated Category 6A FTP Cable, 4-Pair, Plenum Rated Blue F6A650-004-RBL4 F6A650-004-PBL4 White F6A650-004-RWH4 F6A650-004-PWH4 Grey F6A650-004-RGY4 F6A650-004-PGY4 Black F6A650-004-RBK4 F6A650-004-PBK4 Yellow F6A650-004-RYL4 F6A650-004-PYL4 Green F6A650-004-RGN4 F6A650-004-PGN4 Red F6A650-004-RRD4 F6A650-004-PRD4 Orange F6A650-004-ROR4 F6A650-004-POR4 Violet F6A650-004-RVI4 F6A650-004-PVI4 4

Performance Characteristics Meet or exceed Category 6A requirements Frequency¹ Return Loss (RL) Minimum F6A650-R F6A650-P Insertion Loss (Attenuation) Maximum F6A650-R F6A650-P 1 20.0 37.30 37.30 2.1 1.79 1.79 4 23.0 31.83 31.83 3.8 3.30 3.30 10 25.0 32.72 32.72 5.9 5.26 5.26 16 25.0 36.61 36.61 7.5 6.69 6.69 20 25.0 39.05 39.05 8.4 7.52 7.52 31.25 23.6 37.54 37.54 10.5 9.39 9.39 62.5 21.5 37.04 37.04 15.0 13.47 13.47 100 20.1 30.14 30.14 19.1 17.11 17.11 200 18.0 29.21 29.21 27.6 24.50 24.50 250 17.3 28.70 28.70 31.1 27.29 27.29 300 16.8 28.43 28.43 34.3 29.81 29.81 400 15.9 25.95 25.95 40.1 34.70 34.70 500 15.2 24.28 24.28 45.3 39.00 39.00 600 23.70 23.70 44.00 44.00 650 23.50 23.50 46.00 46.00 Frequency¹ Near End Cross Talk (NEXT) Minimum F6A650-R F6A650-P Equal Level Far End Cross Talk (ELFEXT) Minimum F6A650-R F6A650-P 1 74.3 88.03 88.03 67.8 84.38 84.38 4 65.3 81.50 81.50 55.8 83.14 83.14 10 59.3 72.16 72.16 47.8 71.06 71.06 16 56.2 69.38 69.38 43.7 68.75 68.75 20 54.8 68.22 68.22 41.8 68.40 68.40 31.25 51.9 64.58 64.58 37.9 68.29 68.29 62.5 47.4 59.63 59.63 31.9 59.49 59.49 100 44.3 55.67 55.67 27.8 57.56 57.56 200 39.8 54.20 54.20 21.8 52.77 52.77 250 38.3 53.28 53.28 19.8 51.06 51.06 300 37.1 51.37 51.37 18.3 50.03 50.03 400 35.3 48.82 48.82 15.8 48.38 48.38 500 33.8 48.70 48.70 13.8 48.04 48.04 600 47.00 47.00 46.00 46.00 650 46.50 46.50 45.55 45.55 ¹Value above 550Mhz are for informational purposes only Technical Details Item Unit Riser Plenum Conductor DC Resistance Max. Ohms/100 m 9.38 9.38 Resistance Unbalance Max. % 5 5 Mutual Capacitance Max. nf/100 m 5.6 5.6 Capacitance Unbalance Max. pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay Max. ns/100 m 535 @ 650MHz 535 @ 650MHz Delay Skew Max. ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reel Reel Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65) Packages Per Pallet 12 12 Conductors 23 AWG, Solid copper 23 AWG, Solid copper Materials: Insulation in (mm) 0.043 (1.1), HDPE 0.043 (1.1), FEP Jacket in (mm) 0.283 (7.2), PVC 0.295 (7.5), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance Balanced Twisted-Pair Telecommunications Cabling and Components s 5

Category 6+ 550MHz UTP Cable U6550-004-xxxx Conductor Insulation (HDPE/FEP) Rip Cord (Optional) Twisted Pair Jacket (PVC) UL Listed CMR and CMP UL and ETL Verified Capable of handling full broadband and baseband video signals Tight balance requirements improve cable performance Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) Plastic Reel-in-a-Box packaging allows easy access and low tension pulls RoHS compliant Application Horizontal Distribution and Backbone Cabling 155 Mbps ATM, 100 Mbps TP-PMD 10/100/1000 BASE-T (IEEE 802.3) 10GBASE-T up to max. 55 m ISDN, ADSL ATM LAN 1.2G PoE, PoE+ (IEEE 802.3af, IEEE 802.3at) Part Numbers Jacket Color Category 6+ UTP Cable, 4-Pair, Riser Rated Category 6+ UTP Cable, 4-Pair, Plenum Rated Blue U6550-004-RBL3 U6550-004-PBL3 White U6550-004-RWH3 U6550-004-PWH3 Grey U6550-004-RGY3 U6550-004-PGY3 Black U6550-004-RBK3 U6550-004-PBK3 Yellow U6550-004-RYL3 U6550-004-PYL3 Green U6550-004-RGN3 U6550-004-PGN3 Red U6550-004-RRD3 U6550-004-PRD3 Orange U6550-004-ROR3 U6550-004-POR3 Violet U6550-004-RVI3 U6550-004-PVI3 6

Performance Characteristics Meet or exceed Category 6 requirements Frequency² Return Loss (RL) Minimum U6550-R U6550-P Insertion Loss (Attenuation) Maximum U6550-R U6550-P 1 20.0 32.47 29.11 2.0 1.67 1.64 4 23.0 35.22 32.41 3.8 3.28 3.23 10 25.0 35.37 33.16 6.0 5.33 5.31 16 25.0 36.36 34.00 7.6 6.77 6.76 20 25.0 40.57 37.15 8.5 7.61 7.58 31.25 23.6 40.31 37.04 10.7 9.58 9.58 62.5 21.5 38.18 36.64 15.4 13.91 13.92 100 20.1 38.12 34.00 19.8 17.75 17.86 200 18.0 36.48 33.25 29.0 25.57 25.87 250 17.3 33.96 33.24 32.8 28.70 29.52 300 33.08 32.48 31.70 32.91 400 32.82 29.54 36.63 38.09 500 30.00 27.00 37.60 39.00 550 29.00 26.00 38.00 40.00 Frequency² Near End Cross Talk (NEXT) Minimum U6550-R U6550-P Equal Level Far End Cross Talk (ELFEXT) Minimum U6550-R U6550-P 1 74.3 90.90 90.20 67.8 90.02 87.94 4 65.3 87.56 78.98 55.8 88.03 78.84 10 59.3 77.42 75.67 47.8 74.72 75.82 16 56.2 74.65 73.12 43.7 73.97 75.29 20 54.8 73.30 70.97 41.8 69.69 71.51 31.25 51.9 69.83 66.18 37.9 67.73 65.01 62.5 47.4 68.79 63.70 31.9 65.12 64.39 100 44.3 65.48 61.67 27.8 60.79 60.07 200 39.8 63.59 54.78 21.8 59.75 56.31 250 38.3 55.89 51.36 19.8 57.54 47.75 300 53.31 50.54 54.17 47.72 400 53.11 43.43 49.60 45.71 500 52.00 42.10 48.00 44.50 550 51.00 41.00 47.00 43.00 ²Value above 250Mhz are for informational purposes only Technical Details Item Unit Riser Plenum Conductor DC Resistance Max. Ohms/100 m 9.38 9.38 Resistance Unbalance Max. % 5 5 Mutual Capacitance Max. nf/100 m 5.6 5.6 Capacitance Unbalance Max. pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay Max. ns/100 m 536 @ 550MHz 536 @ 550MHz Delay Skew Max. ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reel-in-a-Box Reel-in-a-Box Packaging: Weight lb/kft (kg/km) 24 (36) 26 (39) Packages Per Pallet 27 27 Conductors 23 AWG, Solid copper 23 AWG, Solid copper Materials: Insulation in (mm) 0.038 (0.97), HDPE 0.037 (0.95), FEP Jacket in (mm) 0.236 (6.0), PVC 0.228 (5.8), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance Balanced Twisted-Pair Telecommunications Cabling and Components s 7

Category 6+ 550MHz FTP Cable F6550-004-xxxx Conductor Insulation (HDPE/FEP) Drain Wire Twisted Pair Aluminum Tape Jacket (PVC) UL Listed and Verified Capable of handling full broadband and baseband video signals Tight balance requirements improve cable performance Superior RFI, EMI and alien crosstalk performance by shield technology Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) RoHS compliant Application Horizontal Distribution & Backbone Cabling 155Mbps ATM, 100Mbps TP-PMD 10/100/1000BASE-T (IEEE 802.3) 10GBASE-T up to max. 55 m ISDN, ADSL ATM LAN 1.2G PoE, PoE+ and PoE++ (IEEE 802.3bt draft. Type 3) Part Numbers Jacket Color Category 6+ FTP Cable, 4-Pair, Riser Rated Category 6+ FTP Cable, 4-Pair, Plenum Rated Blue F6550-004-RBL4 F6550-004-PBL4 White F6550-004-RWH4 F6550-004-PWH4 Grey F6550-004-RGY4 F6550-004-PGY4 Black F6550-004-RBK4 F6550-004-PBK4 Yellow F6550-004-RYL4 F6550-004-PYL4 Green F6550-004-RGN4 F6550-004-PGN4 Red F6550-004-RRD4 F6550-004-PRD4 Orange F6550-004-ROR4 F6550-004-POR4 Violet F6550-004-RVI4 F6550-004-PVI4 8

Performance Characteristics Meet or exceed Category 6 requirements Frequency² Return Loss (RL) Minimum F6550-R F6550-P Insertion Loss (Attenuation) Maximum F6550-R 1 20.0 35.13 29.51 2.0 1.84 1.79 4 23.0 35.88 32.23 3.8 3.36 3.34 10 25.0 39.06 35.55 6.0 5.35 5.33 16 25.0 42.62 39.13 7.6 6.78 6.81 20 25.0 36.10 34.90 8.5 7.66 7.65 31.25 23.6 35.92 33.96 10.7 9.52 9.60 62.5 21.5 35.01 33.71 15.4 13.65 13.90 100 20.1 34.52 32.62 19.8 17.25 17.56 200 18.0 33.80 32.31 29.0 24.61 25.50 250 17.3 32.44 30.23 32.8 27.49 28.51 300 30.00 29.00 34.10 33.90 400 29.00 28.00 36.60 36.40 500 28.00 27.00 38.60 38.40 550 27.00 26.00 40.00 40.00 Frequency² Near End Cross Talk (NEXT) Minimum F6550-R F6550-P Equal Level Far End Cross Talk (ELFEXT) Minimum F6550-R 1 74.3 92.20 87.56 67.8 86.41 89.61 4 65.3 77.38 77.98 55.8 77.85 79.51 10 59.3 73.35 72.79 47.8 75.54 75.44 16 56.2 67.18 71.88 43.7 68.18 71.73 20 54.8 65.58 67.29 41.8 66.35 68.93 31.25 51.9 62.87 66.60 37.9 63.68 66.37 62.5 47.4 59.73 63.90 31.9 62.95 62.77 100 44.3 57.22 63.28 27.8 59.70 58.35 200 39.8 55.05 53.58 21.8 47.70 57.42 250 38.3 51.96 51.74 19.8 46.36 54.63 300 45.00 46.00 36.00 35.00 400 41.00 42.00 34.00 34.00 500 39.00 40.00 32.00 32.00 550 38.40 39.40 31.00 31.00 ²Value above 250Mhz are for informational purposes only F6550-P F6550-P Technical Details Item Unit Riser Plenum Conductor DC Resistance Max. Ohms/100 m 9.38 9.38 Resistance Unbalance Max. % 5 5 Mutual Capacitance Max. nf/100 m 5.6 5.6 Capacitance Unbalance Max. pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay Max. ns/100 m 536 @ 550MHz 536 @ 550MHz Delay Skew Max. ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +167 (-20 to +75) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +194 (-20 to +90) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reel Reel Packaging: Weight lb/kft (kg/km) 43 (65) 43 (65) Packages Per Pallet 12 12 Conductors 23 AWG, Solid copper 23 AWG, Solid copper Materials: Insulation in (mm) 0.043 (1.1), HDPE 0.043 (1.1), FEP Jacket in (mm) 0.283 (7.2), PVC 0.283 (7.2), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance Balanced Twisted-Pair Telecommunications Cabling and Components s 9

Category 6 500MHz UTP Cable U6500-004-xxxx Conductor Insulation (HDPE/FEP) Rip Cord (Optional) Twisted Pair Jacket (PVC) UL Listed CMR and CMP UL and ETL Verified 90 C UL Listed & 0.5A-LP Rating for CMP Filler-less design simplifies installation Capable of handling full broadband and baseband video signals Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) Lightweight, easy-pull Reelex packaging eases installation Plastic Reel-in-a-Box packaging allows easy access and low tension pulls Slim cable outer diameter of 0.213 in. (Riser Rated), 0.205 in. (Plenum Rated) RoHS compliant Application Horizontal Distribution & Backbone Cabling 155Mbps ATM, 100Mbps TP-PMD 10/100/1000BASE-T (IEEE 802.3) 10GBASE-T up to max. 55 m ISDN, ADSL ATM LAN 1.2G PoE, PoE+ (IEEE 802.3af, IEEE 802.3at) Part Numbers Category 6 UTP Cable, Non X-filler 4-Pair, Riser Rated Category 6 UTP Cable, Non X-filler 4-Pair, Plenum Rated Jacket Color* Reelex Reel-in-a-Box Reelex Reel-in-a-Box Blue U6500-004-RBL2 U6500-004-RBL3 U6500-004-PBL2 U6500-004-PBL3 White U6500-004-RWH2 U6500-004-RWH3 U6500-004-PWH2 U6500-004-PWH3 Grey U6500-004-RGY2 U6500-004-RGY3 U6500-004-PGY2 U6500-004-PGY3 Black U6500-004-RBK2 U6500-004-RBK3 U6500-004-PBK2 U6500-004-PBK3 Yellow U6500-004-RYL2 U6500-004-RYL3 U6500-004-PYL2 U6500-004-PYL3 Green U6500-004-RGN2 U6500-004-RGN3 U6500-004-PGN2 U6500-004-PGN3 Red U6500-004-RRD2 U6500-004-RRD3 U6500-004-PRD2 U6500-004-PRD3 Orange U6500-004-ROR2 U6500-004-ROR3 U6500-004-POR2 U6500-004-POR3 Violet U6500-004-RVL2 U6500-004-RVI3 U6500-004-PVL2 U6500-004-PVI3 *Other jacket colors available upon request with leadtime and minimum order quantities 10

Performance Characteristics Meet or exceed Category 6 requirements Frequency² Return Loss (RL) Minimum U6500-R U6500-P Insertion Loss (Attenuation) Maximum U6500-R U6500-P 1 20.0 26.65 27.52 2.0 1.75 1.67 4 23.0 34.63 30.54 3.8 3.45 3.28 10 25.0 36.19 30.78 6.0 5.47 5.37 16 25.0 38.58 32.42 7.6 6.97 6.85 20 25.0 44.48 36.16 8.5 7.79 7.70 31.25 23.6 39.60 35.64 10.7 9.81 9.74 62.5 21.5 39.56 34.45 15.4 14.13 14.09 100 20.1 37.99 33.04 19.8 18.08 18.09 200 18.0 34.95 32.49 29.0 26.03 26.44 250 17.3 34.38 27.51 32.8 29.33 29.69 300 38.10 29.85 33.13 33.20 400 33.81 34.86 38.34 38.85 500 35.61 32.97 43.56 43.95 Frequency² Near End Cross Talk (NEXT) Minimum U6500-R U6500-P Equal Level Far End Cross Talk (ELFEXT) Minimum U6500-R U6500-P 1 74.3 94.84 88.35 67.8 92.41 88.03 4 65.3 84.54 74.40 55.8 83.86 75.90 10 59.3 77.86 71.53 47.8 78.20 70.39 16 56.2 75.98 69.46 43.7 76.86 68.13 20 54.8 73.23 69.13 41.8 74.63 65.46 31.25 51.9 70.48 62.72 37.9 72.35 61.81 62.5 47.4 65.07 60.55 31.9 71.30 58.69 100 44.3 63.12 55.10 27.8 64.88 57.71 200 39.8 58.39 54.33 21.8 60.37 49.03 250 38.3 50.62 53.58 19.8 56.90 44.99 300 52.51 49.97 48.40 38.38 400 54.01 55.13 35.33 41.00 500 46.70 64.98 42.04 32.59 ²Value above 250Mhz are for informational purposes only Technical Details Item Unit Riser Plenum Conductor DC Resistance Max. Ohms/100 m 9.38 9.38 Resistance Unbalance Max. % 5 5 Mutual Capacitance Max. nf/100 m 5.6 5.6 Capacitance Unbalance Max. pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay Max. ns/100 m 536 @ 500MHz 536 @ 500MHz Delay Skew Max. ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +140 (-20 to +60) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +176 (-20 to +80) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reelex II Reelex II Packaging: Weight lb/kft (kg/km) 17 (25) 20 (30) Packages Per Pallet 36 36 Conductors 23 AWG, Solid copper 23 AWG, Solid copper Materials: Insulation in (mm) 0.035 (0.90), HDPE 0.034 (0.86), FEP Jacket in (mm) 0.193 (4.9), PVC 0.173 (4.4), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance Balanced Twisted-Pair Telecommunications Cabling and Components s 11

Category 5e 350MHz UTP Cable U5350-004-xxxx Conductor Insulation (HDPE/FEP) Rip Cord Twisted Pair Jacket (PVC) UL Listed CMR and CMP UL and ETL Verified Supports Fast Ethernet, Gigabit Ethernet, 155 Mbps ATM, Multimedia Simplified structured cabling solution preserves long-term network investment Every master reel is tested for electrical performance compliance Dual length marking in feet and meters from 1000 ft (305 m) to 0 ft (0 m) Lightweight, easy-pull Reelex packaging eases installation RoHS compliant Application Horizontal Distribution & Backbone Cabling 155Mbps ATM, 100Mbps TP-PMD 10/100/1000BASE-T (IEEE 802.3) ISDN, ADSL PoE, PoE+ (IEEE 802.3af, IEEE 802.3at) Part Numbers Jacket Color Enhanced Category 5e UTP Cable, 4-Pair, Riser Rated Enhanced Category 5e UTP Cable, 4-Pair, Plenum Rated Blue U5350-004-RBL2 U5350-004-PBL2 White U5350-004-RWH2 U5350-004-PWH2 Grey U5350-004-RGY2 U5350-004-PGY2 Black U5350-004-RBK2 U5350-004-PBK2 Yellow U5350-004-RYL2 U5350-004-PYL2 Green U5350-004-RGN2 U5350-004-PGN2 Red U5350-004-RRD2 U5350-004-PRD2 Orange U5350-004-ROR2 U5350-004-POR2 Violet U5350-004-RVI2 U5350-004-PVI2 12

Performance Characteristics Meet or exceed Category 5e requirements Frequency3 Return Loss (RL) Minimum U5350-R U5350-P Insertion Loss (Attenuation) Maximum U5350-R U5350-P 1 20.0 27.30 27.23 2.0 1.88 1.85 4 23.0 32.46 30.89 4.1 3.75 3.71 10 25.0 35.73 35.47 6.5 6.02 5.97 16 25.0 37.29 36.36 8.2 7.66 7.60 20 25.0 38.84 36.42 9.3 8.60 8.53 31.25 23.6 35.93 34.67 11.7 10.82 10.74 62.5 21.5 33.22 33.37 17.0 15.55 15.47 100 20.1 29.53 31.27 22.0 19.84 19.84 200 29.28 30.39 25.44 21.34 300 28.50 29.50 26.00 22.00 350 27.78 28.26 26.81 22.47 Frequency3 Near End Cross Talk (NEXT) Minimum U5350-R U5350-P Equal Level Far End Cross Talk (ELFEXT) Minimum U5350-R U5350-P 1 65.3 74.32 74.20 63.8 76.96 71.71 4 56.3 72.68 69.65 51.8 68.53 70.38 10 50.3 63.04 62.56 43.8 62.59 65.12 16 47.2 62.02 57.86 39.7 58.18 57.53 20 45.8 57.67 55.20 37.8 57.85 56.97 31.25 42.9 56.72 53.36 33.9 54.83 54.34 62.5 38.4 56.38 52.00 27.9 52.09 49.87 100 35.3 49.38 49.24 23.8 46.60 46.49 200 38.94 41.99 43.13 45.98 300 36.00 41.95 42.50 42.00 350 35.25 41.91 42.08 41.41 3Value above 100Mhz are for informational purposes only Technical Details Item Unit Riser Plenum Conductor DC Resistance Ohms/100 m 9.38 9.38 Resistance Unbalance % 5 5 Mutual Capacitance nf/100 m 5.6 5.6 Capacitance Unbalance pf/100 m 330 330 Characteristic Impedance Ohms 100 ± 15% 100 ± 15% Propagation Delay ns/100 m 536 @ 350 MHz 536 @ 350 MHz Delay Skew ns 45 45 Nominal Velocity of Propagation % 67 70 Operating Temperature F ( C) -4 to +140 (-20 to +60) -4 to +140 (-20 to +60) Storage Temperature F ( C) -4 to +176 (-20 to +80) -4 to +176 (-20 to +80) Bending Radius 4 x Cable diameter 4 x Cable diameter Type 1 kft (305 m) Reelex II Reelex II Packaging: Weight lb/kft (kg/km) 17 (25) 20 (30) Packages Per Pallet 36 36 Conductors 24 AWG, Solid copper 24 AWG, Solid copper Materials: Insulation in (mm) 0.035 (0.90), HDPE 0.034 (0.86), FEP Jacket in (mm) 0.193 (4.9), PVC 0.173 (4.4), LS-PVC (Plenum Rated) Approvals: Safety UL 444, UL 1666 UL 444, NFPA 262 Performance ANSI/ Balanced Twisted-Pair Telecommunications Cabling and Components s 13

RG6 Coax Cable RG6x-x-xxx-x RG-6/U Jacket Foil Conductor Dielectric Braid Jacket Foil Conductor Dielectric Braid RG-6/Q UL Listed CM and CMR Flexible braided 75 ohm coaxial drop cable Support analog, digital and high-bandwidth technologies Maintains tight tolerances to cable diameter requirements of leading connector manufacturers Every master reel is tested for electrical performance compliance RoHS compliant Application HDTV, CATV and CCTV Two-way cable modems Extended bandwidth satellite service Part Numbers Shield/Jacket Color/Package RG 6 Coax Cable, CM (CL2) Rated RG 6 Coax Cable, CMR (CL2R) Rated Dual Shield (60%)/Black/Reelex RG6S-S-MBK-2 RG6S-S-RBK-2 Dual Shield (60%)/White/Reelex RG6S-S-MWH-2 RG6S-S-RWH-2 Quad Shield/Black/Reelex RG6Q-S-MBK-2 RG6Q-S-RBK-2 Quad Shield/White/Reelex RG6Q-S-MWH-2 RG6Q-S-RWH-2 14

Performance Characteristics Attenuation @68 C (20 C) Frequency Insertion Loss (Attenuation) Maximum 55 5.25 211 10 250 10.82 270 11.04 300 11.64 Frequency Insertion Loss (Attenuation) Maximum 330 12.26 350 12.63 400 13.61 450 14.43 500 15.29 Frequency Insertion Loss (Attenuation) Maximum 550 16.08 600 16.3 750 18.54 870 20.04 1,000 21.49 Product Construction Structure Material RG6/U RG6/U Q Inner conductor Copper Clad Steel 1.02±0.01 mm (18AWG) 1.02±0.01 mm (18AWG) Dielectric Foamed PE Nom. 4.57 mm Nom. 4.57 mm Outer 1st shield Bonded Aluminum Foil 4.78±0.13 mm 4.78±0.13 mm Outer 2nd shield Aluminum Braid Outer 3rd shield Aluminum Foil None Outer 4th shield Aluminum Braid None Jacket (Thickness) PVC 6.93±0.10 mm (Nom. 0.80 mm) 7.30±0.10 mm (Nom. 0.86 mm) Technical Details Item Unit Riser Plenum Conduct Resistance (Inner) Ω/km 102 102 Conduct Resistance (DC Loop) Ω/km 150 145 Capacitance (pf/m) pf/m 50±3 50±3 Relative Propagation Velocity % 82 82 SRL (db) [5MHz 1000MHz] db 20 20 SRL (db) [1000MHz 3000MHz] db 15 15 Impedance Ω 75±3 75±3 Operating Temperature F C -4 to +140 (-20 to 60) -4 to +140 (-20 to 60) Type 1 kft (305 m) Reelex II Reelex II Packaging Weight lb/kft (kg/km) 29 (43) 34 (51) Packages Per Pallet 20 20 Approvals Safety UL 444, UL 1685 UL 444, UL 1685 15

PureLink Warranty Terms and Conditions WARRANTY The PureLink Warranty provides that any indoor PureNet Category 5e, 6 and 6A premises copper cable will conform substantially to the ANSI/TIA-568 series industry specifications in force at the time of purchase for a period of (i) twenty five (25) years from the delivery date for any approved connectivity manufacturer (the PureLink Warranty which is issued and administered by Essex Group, Inc. in association with PureNet category cable). SCOPE The PureLink Warranty covers the Cabling Subsystem(s) of the network as defined by the ANSI/TIA-568, which includes the qualifying premises cable and connecting hardware. The PureLink Warranty does not cover other elements of the cabling, such as patch cords and workstation cords. QUALIFICATION To qualify for the PureLink Warranty, customer must meet the following conditions: 1. The connectivity components used in the network must be supplied by one or more of the approved connectivity manufacturers AND each component must be manufactured, tested, and independently verified by UL, ITS/ ETL, or any approved independent testing agency to meet the ANSI/ TIA-568 series industry standard in force at the time of purchase. The approved connectivity manufacturers are subject to change at any time. Please contact Essex Group,Inc. at purelinkwarranty@ for an up-to-date list. The companies currently recognized as approved connectivity manufacturers are: AllenTel Belden IBDN Dynacom Hellermann Tyton Hubbell Legrand/ Ortronics Leviton Molex Panduit Signamax Siemon Superior Modular (OCC) Systimax/ CommScope Uniprise/ CommScope 2. The network system must be designed and installed by BICSI Certified or other designers and installers approved for the PureLink Warranty; 3. Each link in the network must be field tested in accordance with the ANSI/TIA-568 series industry standard in force at the time of purchase AND the installed network links must have passed all ANSI/TIA-568 requirements; 4. The PureLink Warranty application form must be properly completed and submitted to Essex Group, Inc. within 10 days of installation completion; 5. Copies of all test reports must be submitted along with the warranty application form and the Bill of Materials (BOM) to Essex Group, Inc. and be kept on file by the customer for submission to Essex Group, Inc. in the event of a warranty claim. Data must be submitted in the original native file format of the tester (see below) used in the installation and submitted via CD or electronically with the warranty application form. Text or spreadsheet files will not be accepted; 6. The following field testers are acceptable for use to certify installations for warranty coverage: Fluke Networks: DTX 1200/1800/5000 Versiv Psiber Data Systems: WireXpert Ideal Industries: LanTEK II Series Cable Certifier Utilized test equipment must have valid certificate of calibration at time of testing. The acceptable field testers are subject to change at any time. Please contact Essex Group, Inc. at purelinkwarranty@ for an up to date list; and 7. A registered warranty certificate has been issued to the customer for the PureLink Warranty. The PureLink Warranty will be void unless the system is maintained in accordance with industry standards and no changes are made after warranty issuance and acceptance date, unless written consent is granted by Essex Group, Inc. in association with PureNet category cable. WARRANTY EXCLUSIONS The PureLink Warranty does not cover: 1. The installation and maintenance of any other non-performing portions of the Cabling Subsystem(s); 2. PureNet products not specifically designated as being eligible for the PureLink Warranty coverage; 3. PureNet products not supplied directly by Essex Group, Inc. or obtained through unapproved channels; 4. PureNet products which were falsely represented as being in compliance with the PureLink Warranty registration requirements and procedures; 5. PureNet products that are exposed to moisture, liquids (such as paint), or water; 6. Defects resulting from environmental or third party materials, including but not limited to work areas, patching or equipment cords, or from moves, additions and changes by parties other than a Certified Contractor; 7. Defects resulting from a non-compliant or improper system design, installation, use, repair, or any system alterations, misuse, neglect, accident or abuse; or 8. Damage caused by persons, machinery, foreign objects, animals, chemicals, acts of God, or by other means that are beyond normal use. ADMINISTRATION Warranty applications will be approved or disapproved with a response sent to the applicant. Warranty applications and supporting documentation may be sent using one of the following below: 1. PureLink Warranty (Administered by Essex Group, Inc.) Attn; J. Krauskopf 1601 Wall Street Fort Wayne, IN 46802 2. E-mail: purelinkwarranty@ CLAIMS, EXCLUSIVE REMEDIES AND DISCLAIMERS The validity of any warranty claim shall be determined by Essex Group, Inc. in its sole discretion. A claim will be reviewed for validity only if all of the following are satisfied: 1. 1. Reported in writing to Essex Group, Inc. within ten (10) days of date of nonconformity discovery; 2. All installation records are provided to Essex Group, Inc. (original network installation design prints, test results, warranty registration) evidence of original test, including reports showing compliance to all applicable ANSI/TIA 568 requirements; 3. Copies of all original receipts for materials and labor from the date of initial installation are provided to Essex Group, Inc.; and 4. Essex Group, Inc. has full and open access to inspect and evaluate the products and installation site. If a warranty claim is determined by Essex Group, Inc. in its sole discretion to be valid, as customer s sole and exclusive remedy, Essex Group, Inc. will, at its option and using Certified Contractor(s) of its choosing, replace or repair the non-compliant qualifying components of the Cabling Subsystem(s) and cover reasonable cost of labor to affect necessary work. If the customer provides a quote from a Certified Contractor of its choosing, Essex Group, Inc., in its sole discretion, may alternatively elect to allow such Certified Contractor to affect the warranty repair and reimburse the customer for reasonable and customary labor costs, provided prior written approval is obtained from Essex Group, Inc. for proposed materials and labor. If the cause of any error is determined to be improper installation, maintenance or third party repair, the customer may be referred back to the appropriate contractor or third party for support. The remedies of the customer for non-compliant products shall be strictly limited to those provided herein to the exclusion of any and all other remedies including, without limitation, claims for incidental or consequential damages. EXCEPT WITH RESPECT TO THE SPECIFIC WARRANTIES SET FORTH HEREIN, ESSEX GROUP, INC. MAKES NO OTHER WARRANTIES WHATSOEVER, EXPRESS OR IMPLIED, REGARDING THE PRODUCTS, INSTALLATION OR PERFORMANCE OF ITS OBLIGATIONS HEREUNDER, AND SPECIFICALLY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. All information, content, data, specifications, packaging and part numbers detailed herein are subject to change. For the most up to date information, please visit Rev 01/18

Purenet, In-Stock and Ready to Ship! We Have a Convenient Stocking Location Near You. Contact Us Today! 13 WA ME CA OR NV ID UT MT WY 02 CO ND SD NE KS MN IA MO WI IL 01 MI 05 IN KY OH 14 WV PA VA NY VT NH 03 CT MA NJ DE MD DC RI 12 AZ 11 NM 07 OK AR 10 TN 09 SC NC 04 MS AL GA TX 06 LA MX 08 FL 15 Stocking Locations 01 Chicago, IL 05 Fort Wayne, IN 09 McDonough, GA 13 Portland, OR 02 Denver, CO 06 Houston, TX 10 Memphis, TN 14 Simcoe, ON 03 Edison, NJ 07 Lubbock, TX 11 Tempe, AZ 15 Torreon, MX 04 El Paso, TX 08 McAllen, TX 12 Ontario, CA

1601 Wall Street Fort Wayne, Indiana 46802 260.461.4065 LIT 004-E 01/18