TB876BSX-3WH Class E A / Cat.6A STP Keystone Jack (Auto press-fit)

Similar documents
TB806AUX Class E A / Cat.6A UTP Keystone Jack (Auto press-fit)

Class E A / Cat.6A Screened Coupler

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 5e CABLING SOLUTIONS

CATEGORY 6A CABLING SOLUTIONS

CATEGORY 6 CABLING SOLUTIONS

LCS 2 RJ 45 Cat. 6A HD panels and units

LCS2 Cat. 6 RJ 45 Patch panels and units

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

Copper Solution Contents Cabinets Fiber Optic Solution

STRUCTURED CABLING SYSTEMS (SCS)

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

Volition TM RJ45 K5e Jacks

Cat.6 4 Pair UTP Cable

C6 A modul and C6 A modul K. The new connection system for a wide variety of applications of course with Cat.6 A

INFRASTONE BLACKSTONE 10G 6A(U/UTP) Europe, Middle East and Africa regions UNLIMITED USAGE 1

Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*

RJ45FC6-BLU. Base Data. Category 6 modular keystone jack - Blue - 1/bag. Article Number: Part No. RJ45FC6-BLU. Type RJ45FC6. Color.

STRUCTURED CABLING SOLUTIONS

CAT5E NETWORK PATCH LEADS

DINTEK LAN Cabling Systems

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

BTNS TM. FTP Compact Module

Magic Patch Patch Leads & Accessories

C6Amodul and C6Amodul K. The connection system for a wide variety of applications of course with Cat.6A

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

PREMIUM 5e F/UTP PRODUCTS


DIN EUROCARD CONNECTORS

HARTING Ethernet cabling cables and connectors, 4 wire

HDBaseT Installation Guide

SMART CLASSix 24/48 UTP Patch Panels -

MIDDLESEX COUNTY COLLEGE WIRE AND CABLE NETWORK REQUIREMENTS BH, CB, CH, ED, MH, LH, Camera Project


CAT 6 Data Wiring System Connectors

Connect with the industry s best CAT6 and CAT5e channel solutions!

ENTERPRISE COPPER SOLUTIONS

CAT 6 Data Wiring System Connectors

SMART CLASSix 48 UTP Patch Panels (with patching switches) -

Clarity. Advanced solutions for 10 Gig, Category 6 and 5e copper connectivity PRODUCT SOLUTION GUIDE EXPERTISE. TECHNOLOGY. SOLUTIONS.

How to Implement PoE in Your Harsh Industrial Environment

6-Connector- Channel-Link Class E A (STP)

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

HighBand 25. TrueNet Category 6 Solutions

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

Quickreference: Cat.6A EL / Class EA unshielded. Horizontal floor cabling subsystem with unshielded twisted pair technology

What really changes with Category 6

SECTION COMMUNICATIONS HORIZONTAL CABLING

IEEE 802.3af Power via MDI Standard Compliant Mid-Span Insertion Solution. Presented by PowerDsine: David Pincu -

SECTION Structured Cabling Systems

PulseJack 1xN Tab-Down

Manual #: UMA1074 Rev. 2 October, Hall Research Technologies, Inc 1163 Warner Ave. Tustin, CA 92780

Quickreference: Cat.6 A. unshielded. / Class E A. Horizontal floor cabling subsystem with unshielded twisted pair technology

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

Quickreference: Cat.6A EL / Class EA shielded. Horizontal floor cabling subsystem with shielded twisted pair technology

Compact Module. Category 6 FTP Cabling System

EXTENDER ELE8080. INSTALLATION Manual. Made in Taiwan

Quickreference: Cat.6 / Class E shielded. Horizontal floor cabling subsystem with shielded twisted pair technology

Next Generation PoE Standards and Codes Update. Frank Straka Panduit Corporation

APPLIANCES /// MTA, CST-100 II AND SL-156 CONNECTORS. CONNECTORS/ APPLIANCES MTA, CST-100 II and SL-156 Connectors

LAN / NETWORKING PRODUCTS

EFFICIENT CABLING SYSTEM SOLUTIONS.

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Multi-Media Installation Guide

Infinite ways to link... Solution Catalog

Clarity Advanced Solutions6A

blackbox.com/connect The smart choice when price matters most. Need help? Talk to a Black Box cable expert 24/7 at

HD-One DX/DX500 HDMI Extender

BLACK-BOX.EU/CONNECT

CAT6 Cable Tester. Operating Manual. Part No TRIAX - your ultimate connection

RESIDENTIAL CONNECTION OMMERCIAL EXPERT CABLING SAE CATALOG

SECTION 7 -- CROSS-CONNECT SYSTEMS

Advanced PoE - The Impact of Higher Power PoE++ on Twisted-Pair Structured Cabling

A. All communications equipment rooms shall be installed in a neat and workmanlike manner.

Coastal Carolina University RE-BID WILLIAMS BRICE RENOVATION AND REPAIR October 19, 2018 Construction Documents

Simple View TM. From the beginning to the end. We leave nothing out when it comes to your satisfaction.

Quickreference: Cat.6 / Class E unshielded. Horizontal floor cabling subsystem with unshielded twisted pair technology

Volition TM Category 5e cable 100 Ω, FTP

UC Copper / Fibre summary on USPs. Zoran Borcic, Axel Koplev

REQUEST FOR PROPOSAL FOR Supply and Installation UTP Network in the following location

Horizontal or Vertical PCB contacts Bulk Packaging LED colour - Red, Green, Yellow or Blue combinations. Ordering Codes

CAT5 VGA Extender. Mode 1 Mode 2

HD1-LX HDMI & IR Extender

Data Centre & Communications Room. Category 6. Data Centre & Communications Room. 1 0 / B E TrueNet Structured Cabling

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

Professionally Install Products Right the First Time. TOOL-CRIMP Radial Linear compression tool for BNC, F & RCA connectors

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

CAT6Plus System. Brand-Rex Limited

Content BULK CABLES VIDEO CABLES AUDIO CABLES EXTENDERS USB CABLES ETHERNET CABLES VIDEO BALUNS CONNECTORS ADAPTERS PATCH PANELS & WALLPLATES TOOLS

FibrainDATA Vademecum. Premise Networking 2013/14

Belden IBDN System 10GX The next level of cabling performance

Electrical 25 C Operating Temperature 0 C to +70 C TX RX L/R. RJ45 Durability Testing Rating

HDMI EXTENDER ELE8088

FUTURE PROOF YOUR CONNECTIONS

1x12 VGA & Audio over CAT5 Splitter

CONNECT TO VALUE THE SMART CHOICE WHEN PRICE MATTERS MOST BLACK-BOX.EU/CONNECT

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Transcription:

TB876BSX-3WH / Cat.6A STP Keystone Jack (Auto press-fit) Copper braid can be fully contacted and covered for 23-26 AWG solid wire. Press-fit process. 100% RoHS compliant, without soldering. Unique design can resist RJ11/ RJ12 for 200 insertion. IDC contacts: IDC layout for reduced crosstalk. Robust shield cover geometry for better contact resistance and transfer impedance. The keystone jacks come with T568A or T568B wiring and fully comply with ANSI/TIA568-C-2 specifications for Insertion Loss (Attenuation), Near-End Crosstalk (NEXT), Return Loss, and Far-End Crosstalk (FEXT) for data transmissions of any pair combination with frequencies up to 500. Compliance Statement ISO/IEC, EN & TIA Screened / Category 6A Two Connector 4F, No. 306, Tatung Road, Sec 1 Hsichih-Taipei 221, Taiwan, R.O.C Compliance Statement No. 112733B This type of / Category 6A screened two connector permanent link has been tested by 3P Third Party Testing and complies with the 10 Gigabit Ethernet requirements of IEEE P802.3an, requirements of Edition 2.2 of and CENELEC EN 50173-1:2011, and Category 6A requirements of ANSI/TIA-568-C.2. The Compliance Statement is valid for the permanent link type in T568B designation connected with RJ 45 plugs from Telebox, P/N TA3368DS. The qualification may be suspended or withdrawn if it fails to pass a Maintenance Testing performed at 24 month intervals. The permanent link consists of the following components: Cable: Horizontal Cable from Draka, Type Silverline Gold 1000 Qualification Status: Manufacturer verified Conn. Hardw.: Keystone Jack from Telebox, P/N TB876BSx having PCB Marking Cat.6A 001-87620 Patch Panel from Telebox: P/N LB246ASx and P/N MLB246ASx having PCB Marking Cat.6A 001-0895 Qualification Status: Manufacturer Verified th th Hoersholm, 30 November 2012 Hoersholm, 30 November 2012 Ole Lambertsen Test Responsible Poul Villien Coordinating Manager Independent Testing - For End User Confidence

Specification Specification: Qualified Screened Class EA / Category 6A / of ANSI/TIA-568-C.2 IEC 60603-7-51 2.2 Edition CENELEC EN 50173-1:2011 Physicals: Housing : PC UL 94V-0 PCB MODULE Insertion : PBT UL 94V-0 Contact : Ø 0.46 mm Phosphor bronze, gold over nickel plating IDC Holder : PC UL 94V-0 PCB : FR4 UL 94V-0 Cap : PC UL 94V-0 Color code label : Paper Door : PC UL 94V-0 Contact spring : Phosphor bronze, nikel plating. Shield base : SPTE Shield cap : SPTE KT8702 Compress Tool HT87X8 Hand Tool TB87 XX X X - 3 XX 58 : Cat.5e 68 : Cat.6 6A : Cat.6A 62 : Conn.H U : Unshielded S : Shielded D : door T : withdoor WH : White BK : Black

/ Cat.6A Standard Configuration Cat.6A or (500) AMD 2 CENELEC EN50173-1 EIA/TIA 568-C.2 <<Comparison Chart I>> Cat.6A Cat.6A For the regional US American cabling standard EIA/ TIA 568-C.2, see <<Comparison Chart I>>, it describes channels and permanent links as Cat. 6A. For the international cabling standard and the European cabling standard EN 50173-1, both standards configurations like channels and permanent links are called. When you compare EIA/TIA with ISO/IEC or EN, they are not only naming differently, but also transmission performance requirements show significant variations, see below comparison charts. Minimum NEXT db -20-30 -40 v.s. EIA/TIA568-C.2 NEXT Limits -50 100 200 300 400 500 Transmission performance differences between ISO/IEC and EIA/TIA 1.0 16.0 100.0 200.0 250.0 350.0 500.0 53.2 39.9 34.8 33.1 30.6 27.9 53.2 39.9 34.8 33.1 30.3 26.1 Minimum NEXT db -20-30 -40 v.s. EIA/TIA568-C.2 NEXT Limits -50 100 200 300 400 500 Transmission performance differences between ISO/IEC and EIA/TIA 1.0 16.0 100.0 200.0 250.0 350.0 450.0 500.0 54.6 41.8 36.9 35.3 32.6 30.2 27.8 54.6 41.8 36.9 35.3 31.8 26.7 Automatically Pressing contacts and IDC into a plated-through hole in the PCB. Advantages of Press-fit Connectors: - Stable and reliable form of the contact - Time-saving production - Cost effective, no manual soldering - Environmentally friendly - Reduced inspection process

L L R R Cat.6A 10G Relative Products KP24XX Keystone Type KP16XX Keystone Type 151.30 151.30 482.60 40 @27*15=405.00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Cat.6 31.80 44.00 PANEL & KSJ ASS'Y SIDE VIEW DR0101S-XX STP DIN Rail Adapter for Keystone Jack TA3700-X USA type Wall Plate for Keystone Jack

Relative Products TA6288-KWH 2P Surface Mount Box TA52202 French Wallplate (81x81) + Backbox Single Gang Backbox