SERTEL NTP SERVER Teleclock - [T-GPS-300-TL]

Similar documents
Precision Time Protocol - PTP (IEEE 1588 v2) OSA PTP Products. slide 1

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

DA E: Series of Narrowband or Wideband Distribution Amplifiers

ThinkRF D GHz RF Downconverter

10MHz Source/Inserter

G4500. Portable Power Quality Analyser. Energy Efficiency through power quality

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

SAPLING MASTER CLOCKS

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

1/3 RACK-MOUNTED BLOCK CONVERTERS

SAPLING WIRED SYSTEM

Instruction Manual Model # Block Upconverter

MULTIBAND 1/3 RACK-MOUNTED

L-Band Block Upconverter

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

L-Band Block Up- and Downconverter Indoor / Outdoor

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Model 5401 Dante Master Clock

TRIMBLE GPS / 10MHz REFERENCE MONITOR DISPLAY V January 2015

Primary Reference Clocks (PRC/SSU)

Inmarsat Downconverter Narrowband Downconverter

GlobalTime Electronic Co.,Ltd.

GFT Channel Digital Delay Generator

Digital Clock with Second Circle DA Series

Synthesized Block Up- and Downconverter Indoor / Outdoor

Advanced Test Equipment Rentals ATEC (2832)

Satellite Up- and Downconverter Indoor / Outdoor

5600MSC, 5601MSC Master SPG/Master Clock Systems

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model BlockUpconverter

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

5600MSC, 5601MSC Master SPG/Master Clock Systems

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Q516 HIGH RES AUDIO DELAY ORDERING OPTIONS SUPPORT OPTIONS MANAGEMENT AND CONTROL HIGH PRECISION AUDIO DELAY FOR MICRO SECOND ACCURACY

Synthesized Clock Generator

SAL Series Wireless Clock (V1)

Sapling Wired System. Synchronized Clock Systems

Quick Operation Guide of LTN7700/7600 Series NVR

ALPAN W Compact DTV Transmitters 3-4U 19 HE DIGITAL ANALOG

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Sapling Wired System. The Sapling Company, Inc Republic Road Huntingdon Valley, PA P F

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Datasheet SHF A

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Multiple Band Outdoor Block Up- and Downconverters

CRT1041M-C-02 CRT1041M-C-02 DATASHEET DATASHEET. 4-channel DVB-C modulator

Signal Stability Analyser

Modular Block Converter Systems

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Instruction Manual Model Block Downconverter

2 MHz Lock-In Amplifier

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

JD725A Cable and Antenna Analyzer - Dual Port

DS-7204/7208/7216HVI-ST Series DVR Technical Manual

Instruction Manual Model Downconverter

Synthesized Block Up- and Downconverter

Introduction This application note describes the XTREME-1000E 8VSB Digital Exciter and its applications.

Power Amplifier 1.5 MHz to 18 GHz, Split Bands. Now with smart digital monitoring and control options 19 Rack Mount Family Data Sheet

GFT Channel Slave Generator

Instruction Manual Model Up/Downconverter

Satellite Up- and Downconverter

POLMON WIRELESS CLOCK NETWORK. Rev:00 POLMON SYNCRONIZED WIRELESS CLOCK NETWORK PRODUCT DETAILS

Instruction Manual Model Upconverter

High-Value 100 Series (Outdoor)

MULTIMIX 8/4 DIGITAL AUDIO-PROCESSING

Dragon. manual version 1.6

35058-TE. PLJ-6LED-A LED Frequency Display Module Manual

DS-7200HVI/HFI-SH Series DVR Quick Operation Guide

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

OTX Optical Transmitter. Operation Instructions

National Park Service Photo TSG-460 & CO 465. Universal SPG/TPG, Time Reference and Changeover Series.

LAUREL ELECTRONICS, INC.

Product Catalogue January 2018

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Satellite Up- and Downconverter

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

MICROLITHIC DOUBLE-BALANCED MIXER

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

i-repeater Control and monitor all your repeaters through the cloud Rackmount Wallmount

QRF5000 MDU ENCODER. Data Sheet

Typical applications:

DSIM-AF Installation Guide Revision B

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Modular Lube Lubrication Systems System Controls

DSIM-GI Installation Guide Revision P

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Technical Description

9700/9700AT 9710 Programmable Time System

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

L-BAND FREQUENCY CONVERTER

OPTICAL DISTRIBUTION STATION -

Agilent 5345A Universal Counter, 500 MHz

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Transcription:

A Sertel Electronics Manual No. 377, Nehru Nagar, Chennai, Tamil Nadu 600-096 Ph: 044-23454060/61 www.serteltelser.com,www.sertelelectronics.com SERTEL NTP SERVER Teleclock - [T-GPS-300-TL] Date : 25-05-2012

Introduction: OPERATIONAL MANUAL This document details the operations of our T-GPS-300 which is a Time Sync Server with capabilities to provide time synchronization outputs through NTP protocols. OVERVIEW: One of the primary necessities in power plants and substations control, supervisory data recorders are time synchronized using a Master Clock system. Time synchronization simplifies the task of fault analysis in the incident of a fault situation event between networks. Time synchronization also increases the accuracy of control decisions by automatic control and protection equipment in the power network, therefore allowing optimal utilization of network assets. Most modern protection Relays and Intelligent Electronic Devices (IED) come fitted with a port to accept a time synchronization signal- NTP Ethernet based synchronization. Sertel provide precise time and frequency signals that keeps time for sophisticated communication systems maintaining accuracies of data to order of micro, nano-seconds. The GPS Time Sync Server model T-GPS-300 is a compact all-in-one box solution in 3U (133.5mm H) size, featured and cost effective system of GPS time synchronization solution. Date : 25-05-2012

Basic Features: 1. Receive up to 12 channels (satellites) in parallel mode. 2. 16x2 LCD display to show the TIME, DATE, LATITUDE, LONGITUDE, AND TIME ZONE. 3. Most compact in size and specially designed to suit the requirement in power, process utilities. 4. Usage of High precision OCXO crystal for frequency maintaining ns level accuracy. 5. Ethernet sync server provides time and date through NTP port to be accessed by other system. 6. Time adjustment is provided with given keys and can be saved in RTC for master clock mode operation. 7. Packed in 3U of compact size with redundant power supply unit. 8. Universal Power supply: 90 to 230V AC/DC

HIGH STABILITY OF OCXO: High Stability OCXO suitable for synchrophasor equipments accuracy OUTPUT SIGNAL: Sine wave HARMONICS: -10 dbc * SPURIOUS: -70 dbc * OUTPUT IMPEDANCE: 50 LEVEL / LOAD: 20MHz 4 dbm / 50 > 20MHz 0 dbm / 50 TEMP. RANGE * -40 to +85 C STABILITY * ±0.25 ppm (0.5 ppm peak to peak) Timing Accuracy will be better than 1 micro-second. Timing Accuracy of T-GPS-300: 14ns (NPL certificate) CALCULATION FOR STABILITY OF OCXO: Higher Stability of OCXO We use higher stability of Oscillator to achieve 10-8 5 MHz = 5x0.25 PPM =1.25 Cycles For ONE MONTH = 31 x 24 x 60 x 60 x 0.25µSec = ± 669600 µsec = ± 0.67 Seconds For One Day = ± 0.67/30 = ± 0.022 Secs/Day

OPERATION: NTP Time Sync Server is connected with power supply and the system runs with high precision OCXO Crystal for frequency. The LCD display time, date and Time zone can be set through a simple user-interface using buttons ENTER, NEXT, INC and then saved internally. Priority Basis for the Input Source: 1. Source: NTP- Signal as Highest Priority as time source 2. Source: Internal Master Clock. The RS232 outputs are also available from the output ports. The statuses of input modes like GPS/ Master Mode are indicated by the corresponding LCD s. GPS Time Sync Server also provides time and date in SERTEL format through RS232 output which is electrically and mechanically standardized to be called as DTE. INPUTS: Power Supply 90 to 230V AC/DC NTP Source OCXO-Crystal as external source. Keypad inputs for time and date updates.

OUTPUTS: NTP outputs for NTP client access (Default IP: 192.168.1.254). RS232 serial port output in SERTEL format. Alarm signal output for GPS fails indication. LCD displays Time, Date, Time zone, Latitude and Longitude. NTP/SNTP Capabilities: Network Time Protocol (NTP) is TCP/UDP protocol uses Ethernet Time Server for synchronizing the time on computers across a network. A NTP time server is used to obtain the correct time from a time source and adjust the local time in each connecting computer. NTP provides accuracies of between 1 and 50 milliseconds depending on the time source and network paths. Simple Network Time Protocol (SNTP) can be described exactly the same as NTP, the differences can be found in the time synchronization program running on each individual server. SNTP is usually used on preset time of a network to synchronize workstations where the accuracy of NTP is not required. NTP normally uses multiple time servers to verify the time, while SNTP uses just one Ethernet Time Server to calculate the time. The NTP algorithm is much more complicated than the SNTP algorithm. Sertel GPS Time Sync Server is NTP Version 4, which can operate in either unicast (point to point), multicast (point to multipoint) or any cast (multipoint to point) modes. For synchronizing time and date of the system in point to point mode, click on date and time of the system and then a window will pop out and then click on properties and then click on internet time and enter NTP server IP address (192.165.1.254) inside the server box and then click on apply and then close the window, now the system access the server time and date. For the details go through SERTEL NTP README file instructions.

ELECTRICAL CHARATERISTICS: Temperature range operation : -40 C to +85 C Voltage Require : 90-260V AC/DCC Current : 2Amps Power consumed : 24Watts MECHANICAL SPECIFICATION: Size in mm Weight :3(U) 485 (W) X 325 (D), U=44.5mm :4.5Kg (±0.5)Kg

FRONT VIEW: REAR VIEW:

NTP SERVER DATASHEET MANUFACTURER SPECIFICATION SERTEL DESCRIPTION MODEL NO. TYPE DISPLAY T-GPS-300 NTP SERVER CHARACTER 16 X 2 LCD OCXO CRYSTAL OUTPUT SIGNAL SINE WAVE HARMONICS -10 dbc * SPURIOUS: -70 dbc * OUTPUT IMPEDANCE: 50 LEVEL / LOAD 20MHz 4 dbm / 50 > 20MHz 0 dbm / 50 TEMP. RANGE -40 to +85 C STABILITY ±0.25 ppm (0.5 ppm peak to peak) TIMING ACCURACY OF IRIG-B 1 micro-second TIMING ACCURACY OF T-GPS-300 14ns (NPL certificate) POWER SUPPLY REDUNDANT POWER SUPPLY INPUT POWER 90-230 V AC / DC BATTERY BACKUP ONLY FOR GPS RECEIVER CPU ASSEMBLY DIMENSIONS 3U(H)X 325 (D) X 485(W) [Note: 1U = 44.5mm] MOUNTING 19 INCH RACK PANEL MOUNTING