TELEDYNE HASTINGS INSTRUMENTS

Similar documents
Operating Instructions

Vacuum measurement and control units

SCALE & WEIGHT DISPLAYS

Electromagnetic Block Valves Direct Acting

263 Series LED Bargraph Indicator and Controllers

LAUREL ELECTRONICS, INC.

Modular Lube Lubrication Systems System Controls

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

PROPORTIONAL VALVES Sentronic plus

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

IONIVAC Transmitter ITR 90

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Single Point Flow Monitor SW118 SW119

Process Transmitter RMA 422

Pen and Multichannel Recorder: Digital Display

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

ITER Product Catalog Total Pressure Measurement. ITER Product Catalogue Total Pressure Measurement V Page 1 / 15

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Engineered to meet your needs T he oldest name in stud welding,

Micro-Machined Silicon Transducers

Wall-/Pipe-Mount Level Indicator

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

SAL Series Wireless Clock (V1)

DCP100 Digital Control Programmer Specifications

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

OTS-300 Express Series Power Meters/Sources and Testers

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

PRINCIPLES AND APPLICATIONS

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Level Measurement silometer FMC 420, FMC 423

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

SERIES 400 SERIES 620

SRM W 15" Portable Powered Subwoofer

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Dissolved Oxygen Transmitter

DMP 331i / DMP 333i LMP 331 i

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Meteor Product Catalogue

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Dissolved Oxygen Transmitter

HDBaseT HDMI Extender

MS2540 Current Loop Receiver with RS485 Communication

OPERATION MANUAL JENDPM008 THERMOCOUPLE PANEL THERMOMETER. TIP TEMPerature Products 340 W Broad Street Burlington, NJ 08016

FN Series Scalable N+1 UPS 3kVA to 40kVA Tower

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Micro-DCI 53ML5100 Manual Loader

HOBO H Energy Logger

Section C Recorders. DPR mm Digital Strip Chart Recorder

HDMI over IP Extender Kit with Video Wall Support p

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Ocean Sensor Systems, Inc. Wave Staff, OSSI F, Water Level Sensor With 0-5V, RS232 & Alarm Outputs, 1 to 20 Meter Staff

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

PACSystems* RX3i Thermocouple Input Module, 12 Channels, IC695ALG412-CB

TempScan/1100 & MultiScan/1200

GP-500 SERIES - Low Voltage

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

TABLE OF CONTENTS. Instructions:

SPECIFICATION NO Model 207 Automatic GTAW Welding System

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

HiPace 300 with TC 110 and power supply OPS 100, DN 100 ISO-F

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

LINE DRIVERS MANUAL PART NUMBER: DA3000TM0 1-IN, 1-OUT COMPOSITE VIDEO + AUDIO LINE DRIVER TABLE MOUNT USER S GUIDE

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

Table of contents 1. INTRODUCTION GENERAL CONTENTS OF PACKAGE GENERAL USE OF THE EQUFLOW 6100 D/A CONVERTER STORAGE..

Series 937B. Features & Benefits

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Model KBF 1020 Constant climate chambers with large temperature / humidity range

SPECIFICATION NO NOTE

Model KBF 115 Constant climate chambers with large temperature / humidity range

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

Specifications. End-Point Linearity - ±5% F.S., when used with HACO SCR-speed control

Phono Amplifier brinkmann «EDISON» Manual.

ELE C TRO MAG N E T I C FLO W M E T E RS

Stud Welding Equipment

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Modular Block Converter Systems

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

HDMI over CAT5 HDBaseT Extender - Power over Cable - IR - RS232-10/100 Ethernet - Ultra HD 4K ft (100m)

Single sensor setup with NIVEL210

8 Ports. 16 Ports. ED5219LGT Series. CATV Single Channel EDFA 1310nm Forward Optical Transmitter

HDMI Over IP Extender Kit - 4K

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

IMPAC Infrared Thermometers

PT8420 Cable Actuated Sensor Industrial ma 0..20mA

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

TC3301. User's Manual

PACSystems* RX3i. Isolated Thermocouple Input Module, 6 Channels, IC695ALG306-EB Isolated Thermocouple Input Module, 12 Channels, IC695ALG312-EB

Transcription:

DVT (Digital VT) DCVT (Digital CVT) www.teledyne-hi.com TELEDYNE HASTINGS INSTRUMENTS Vacuum Measurement RANGES DV-4 (0.1 20 Torr) DV-5 (0.1 100 mtorr) DV-6 (1 999 mtorr) FEATURES Linear Analog Output (DCVT): 0-1 VDC / 0-5 VDC / 0-10 VDC 0-20 ma / 4-20 ma Digital Output - RS232 (DCVT) Dual Setpoint Control Relays (DCVT) Bright, Easy-to-Read Digital Display Available in Torr, mbar, or Pascal Compatible with Calibration Reference Tubes APPLICATIONS Refrigeration / HVAC Power/Transformer Fill & Maintenance Cryogenics/Vacuum Insulation Vacuum Coating Vacuum Furnaces Freeze Drying Accelerators BENEFITS Proven Reliability / Less Downtime Easy Installation and Operation Low Cost DVT & DCVT Vacuum Measurement Download a free QR reader from your smart phone app store

www.teledyne-hi.com Description & Specifications DESCRIPTION The Teledyne Hastings Instruments DVT & DCVT are digital readout versions of the successful VT/CVT-Series Hastings Gauges which have generated loyal customers for over 50 years. A reputation has been built on exceptional stability, accuracy, and reliability under the most demanding conditions. Both the DVT & DCVT feature a precision A/D converter along with a microprocessor to measure the thermocouple vacuum gauge tube s signal output. The microprocessor converts the measurement to a pressure reading by employing the gauge tube s welldefined output/pressure relationship. The result is displayed using a bright 3-digit green LED display. Both the DVT & DCVT are packaged in an 1/8 DIN case which can be panel mounted. The Digital VT/CVT Vacuum Gauge Meters are available for three of THI s most popular gauge tube families: DV-4, DV-5 and DV-6. These tubes utilize THI s rugged but sensitive noble metal thermocouples that are designed specifically for each range. Tubes are matched and interchangeable without calibration adjustments. They are compensated for temperature and rate of temperature change and are corrosion resistant. DCVT - Digital Vacuum Controller The DCVT includes several enhanced features which makes it an attractive solution for many vacuum control automation applications. The DCVT can provide linear analog output (voltage or current) for integration of vacuum measurement with a PLC or other data acquisition system. In addition, the DCVT provides RS232 communication for direct connection of the instrument to a computer. The DCVT also includes two independent user selectable set point relays for process control. The control relays are durable 10 Amp single pole double throw which can be wired in a normally open or normally closed configuration. Hastings Instruments reserves the right to change or modify the design of its equipment without any obligation to provide notification of change or intent to change. VCR is a registered trademark of Cajon Company. Conflat is a registered trademark of Varian Associates, Inc. Mini-Conflat is a trademark of Varian Associates, Inc. COMMON SPECIFICATIONS (DVT & DCVT) Range Digital Accuracy (Display and RS232) Cables DVT-4 / DCVT-4 DCVT-5 DVT-6 / DCVT-6 SPECIFICATIONS DVT (Digital VT) Operating Temperature 5 50 C Power Requirements With universal power converter (included) DC Input Requirements (If not using universal converter) Connector Weight (approx.) 0.1 20 Torr 0.1 100 mtorr 1 999 mtorr DCVT-4 ± (20% of reading + 0.01 Torr) (max) DCVT-5 ± (20% of reading + 0.2 mtorr) (max) DCVT-6 ± (15% of reading + 1 mtorr) (max) 6-ft power cable and 8-ft sensor cable included. Sensor cable lengths up to 100 ft. are available. 90 240 VAC, 47 63 Hz, 2 W 4.5 5.3 VDC @ 155 ma 6 pin Terminal Block 0.5 lbs. (0.2 kg) SPECIFICATIONS DCVT (Digital CVT) Operating Temperature -20 70 C Power Requirements DC Input Requirements (If not using AC input ) Connector (Gauge Tube, Analog Out, Relays) Connector (RS232 Serial Port) Weight (approx.) Analog Output Accuracy Serial Communications Relays 90-250 VAC, 47-63 Hz, 5 W 22-25 VDC, 1.5 W 12 pin Terminal Block 6P6C Modular 0.7 lbs. (0.3 kg) DCVT-4 ± (20% of reading + 0.02 Torr) (max) DCVT-5 ± (20% of reading + 0.4 mtorr) (max) DCVT-6 ± (15% of reading + 2 mtorr) (max) RS232, 9600 19200 baud 250 VAC @ 10 Amp 100 VDC @ 5 A (max) 5 VDC @ 0.1 Amp (min)

Outline Drawings www.teledyne-hi.com

www.teledyne-hi.com DVT Selection Chart Model Number DVT-4 DVT-6 Standard B Cabinet DVT Shipment Includes DVT Electronics Module 8 Foot Gauge Tube Cable AC/DC Universal Power Supply AC Plug Adapter Panel Mount Hardware DVT in Cabinet Stock # CB-DVT-8 CB-DVT-25 DVT Cables Cable,Digital VT,8' (std) Cable,Digital VT,25' Stock # 12-01-165 12-01-164 DVT Cables UK Service European Service CB-DVT-50 CB-DVT-100 CB-DVT-XXX Cable,Digital VT,50' Cable,Digital VT,100 Cable,Digital VT,SPCL' DVT Rear View

www.teledyne-hi.com DCVT Selection Chart Model Number DCVT-4 DCVT-5 DCVT-6 Pressure Units - - Analog Output B Standard Cabinet Pressure Units 01 Torr 02 mbar 03 Pascal DCVT Shipment Includes DCVT Electronics Module 8 Foot Gauge Tube Cable AC Cordset Panel Mount Hardware 01 02 03 04 05 06 Analog Output 0-1 VDC Non-Linear 0-1 VDC Linear 0-5 VDC Linear 0-10 VDC Linear 4-20 ma Linear 0-20 ma Linear Stock # CB-DCVT-8 CB-DCVT-25 CB-DCVT-50 CB-DCVT-100 CB-DCVT-XXX DCVT Cables Cable,Digital CVT,8' (std) Cable,Digital CVT,25' Cable,Digital CVT,50' Cable,Digital CVT,100 Cable,Digital CVT,SPCL' DCVT Rear View

Gauge Tube Selection Chart www.teledyne-hi.com Gauge tubes are sold separately. For an entire list of available gauge tubes for use with the DVT & DCVT, see Product Bulletin PB-105. Instrument Series DVT DCVT DCVT DVT DCVT Vacuum Range 0.1-20 Torr 0.1-100 mtorr 1-1000 mtorr Color Band Purple Red Yellow 1/8" NPT - Standard DV-4D DV-5M DV-6M 1/8" NPT - Ruggedized DV-4R ---- DV-6R VCR DV-4D-VCR DV-5M-VCR DV-6-VCR KF-16 DV-4D-KF-16 ---- DV-6-KF-16 KF-25 DV-4D-KF-25 ---- DV-6-KF-25 Mini-CF ---- ---- DV-6R-CF Stainless (high temp/pressure) Robust with Protective Cup DV-34 ---- DV-36 ---- ---- DV-6S Glass 3/8" OD ---- ---- DV-20 Reference Tubes DB-16D DB-18 DB-20 Note: Color band is not used on all tubes. For proper accuracy and performance, Teledyne Hastings Vacuum Gauges should always be used with the proper range of Teledyne Hastings Vacuum Gauge Tubes. Telephone: (757) 723-6531 Toll Free: (800) 950-2468 Fax: (757) 723-3925 World Wide Web: http://www.teledyne-hi.com E-mail: hastings_instruments@teledyne.com P.O. Box 1436 Hampton, VA 23661 PB-182_08/11 Teledyne 2011 All Rights Reserved.