Agilent N4876A 28 Gb/s Multiplexer 2:1

Similar documents
Agilent N4876A 28 Gb/s Multiplexer 2:1

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Exceptional performance

Electrical and Optical Clock Data Recovery Solutions up to 32 Gb/s

Agilent Series Harmonic Mixers

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Agilent 86120B, 86120C, 86122B Multi-Wavelength Meters. Data Sheet

Keysight Technologies Achieve High-Quality Compliance Test Results Using A Top-Quality Test Fixture. Application Note

FlexRay Physical Layer Eye-diagram Mask Testing

Keysight Technologies M8048A ISI Channels

Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster

Keysight N1085A PAM-4 Measurement Application For 86100D DCA-X Series Oscilloscopes. Data Sheet

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Agilent N4965A Multi-Channel BERT 12.5 Gb/s Data Sheet

Agilent N5183A MXG Microwave Signal Generator

Evaluating Oscilloscope Mask Testing for Six Sigma Quality Standards

Keysight Technologies ad Integrated RF Test Solution

Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details

Agilent E4887A HDMI TMDS Signal Generator Platform

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Agilent M9362A-D01-F26 PXIe Quad Downconverter

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Keysight Technologies N4917A Optical Receiver Stress Test Solution. Data Sheet Version 1.3 New: Extension to 8G Fibre Channel

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Keysight E4887A HDMI TMDS Signal Generator Platform. Data Sheet Version 2.1

Keysight Technologies N5998A HDMI Protocol/Audio/Video Analyzer and Generator

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Time-Saving Features in Economy Oscilloscopes Streamline Test

Keysight Technologies Using Oscilloscope Segmented Memory for Serial Bus Applications. Application Note

Agilent V3500A Handheld RF Power Meter

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Keysight N4965A Multi-Channel BERT 12.5 Gb/s. Data Sheet

Electrical Sampling Modules

Agilent M9361A PXI Downconverter

Keysight Technologies Oscilloscope Display Quality Impacts Ability to View Subtle Signal Details. Application Note

Keysight Technologies Segmented Memory Acquisition for InfiniiVision Series Oscilloscopes. Data Sheet

46 GBaud Multi-Format Optical Transmitter

Agilent Technologies Series of RF and Universal Frequency Counter/Timers. Family Overview

M809256PA OIF-CEI CEI-56G Pre-Compliance Receiver Test Application

Keysight Technologies

Logic Analysis Fundamentals

Keysight Technologies High-Power Measurements Using the E5072A ENA Series Network Analyzer. Application Note

Agilent 83000A Series Microwave System Amplifiers

Selecting the Right Oscilloscope for Protocol Analysis Applications

Keysight Technologies

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

Agilent Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Data Sheet

CAN/LIN Measurements (Option AMS) for Agilent s InfiniiVision Series Oscilloscopes

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

Optical Sampling Modules 80C02 80C07B 80C08C 80C10 80C10B 80C11 80C12

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

Agilent E4416A/E4417A EPM-P Series Power Meters and E-Series E9320 Peak and Average Power Sensors. Data Sheet

Keysight Technologies ad Waveform Generation & Analysis Testbed, Reference Solution

Agilent Understanding the Agilent 34405A DMM Operation Application Note

Agilent Series Preselected Millimeter Mixers

N4917BACA Optical Receiver Stress Test Solution 100 Gb/s Ethernet

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

Keysight Technologies Electrical and Optical Clock Data Recovery Solutions

Agilent Migration from 8712/8714 Series to ENA-L Network Analyzers

Agilent Technologies Pulse Pattern and Data Generators Digital Stimulus Solutions

Agilent E6701G GSM/GPRS and E6704A EGPRS Lab Applications

PBR-310C E-BERT. 10Gb/s BERT System with Eye Diagram Tracer

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

A Simple, Yet Powerful Method to Characterize Differential Interconnects

RS-232/UART Triggering and Hardware-Based Decode (N5457A) for Agilent InfiniiVision Oscilloscopes

Keysight Technologies Millimeter Wave Frequency Extenders From Virginia Diodes Inc. for the Keysight X-Series Signal Analyzers. Technical Overview

Full-featured CW Microwave Counters for Field, Factory or Lab

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Agilent Power Meters and Sensors

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Single-Output 2000 W

serial cell generator & analyzer central line interface clk in** data in main out detect enable HP E4853A (**: opt 002)

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Data Pattern Generator

R&S ZN-Z154 Calibration Unit Specifications

Agilent M9202A PXI-Express Wideband IF Digitizer

32 G/64 Gbaud Multi Channel PAM4 BERT

Keysight Technologies 83000A Series Microwave System Amplifiers

Keysight Technologies Oscilloscope Measurement Tools to Help Debug Automotive Serial Buses Faster. Application Note


80C00 Optical Modules for DSA8300 Sampling Oscilloscope Datasheet

Automatic Changeover Unit ECO8000 Datasheet

R&S ZN-Z85 Switch Matrix Specifications

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

R&S FPC1000 Spectrum Analyzer Specifications

Tektronix Video Signal Generators

Automatic Changeover Unit ECO8020 Datasheet

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Digital Storage Oscilloscopes 2550 Series

Keysight Technologies Decoding Automotive Key Fob Communication based on Manchester-encoded ASK Modulation

Datasheet SHF A Multi-Channel Error Analyzer

Microwave Counter, Power Meter and DVM in One Portable Package

R&S ZVA110 Vector Network Analyzer Specifications

Agilent Technologies N5454A Segmented Memory Acquisition for Agilent InfiniiVision Series Oscilloscopes

Agilent 11713A Attenuator/Switch Driver

Transcription:

Agilent N4876A 28 Gb/s Multiplexer 2:1 Data Sheet, Revision 1.1 Features and Benefits Variable data rate up to 28.4 Gb/s Multiplexes two generator channels Front-end box for J-BERT or ParBERT Control via J-BERT or with stand-alone user interface via USB/LAN interface Small size

Applications Accurate characterization up to 28 Gb/s The N4876A 28 Gb/s Multiplexer allows to extend the pattern gene-rator data rate of the J-BERT N4903B and ParBERT 81250A up to 28.4 Gb/s. Design and test engineers in the semiconductor, communications, storage and computer industry can now accurately characterize the next generation of serial interfaces operating at bit rates of up to 28.4 Gb/s. With its excellent performance the N4876A helps to optimize design margins by minimizing the influence of the test equipment on measurement results. The multiplexer is transparent to jitter, so when using it with the J-BERT N4903B, calibrated RJ and PJ can be generated. The small size allows locating the device under test closely to the s of the N4876A. Affordable path to 28 Gb/s pattern generation The N4876A multiplexer doubles the pattern generator data rate by multiplexing two pattern generator channels. The N4876A extends the variable generator data rate of J-BERT N4903B up to 28.4 Gb/s and of ParBERT 81250A up to 27.0 Gb/s. It s an affordable path to extend the operating rate up to 28.4 Gb/s by just adding the multiplexer frontend to a 12.5/13.5/14.2 Gb/s BERT pattern generator. Accurate eye, mask and jitter analysis The Agilent Infiniium DCA-X wide bandwidth oscilloscope offers the most precise waveform, eye, mask and jitter analysis of optical or electrical and advanced eye analysis options. Figure 1. The N4876A multiplexer offers excellent performance. The example shows a 28.4 Gb/s signal, using J-BERT s internal clock, PRBS15 and is captured with Agilent 86118A and 86107A precision time-based modules. Target Applications for N4876A IEEE 802.3 ba 100GBASE-LR4, -ER4 interfaces operating at data rates of 25.78125 Gb/s OIF CEI backplanes operating between 19.9 and 28 Gb/s T11 16x or 32x fibre channel 14.025 and 25.8 Gb/s Infiniband EDR 25.78125 Gb/s Clean generator for transmitter test Stressed generator for receiver tolerance testing Clock/2 jitter injection Two differential 28 Gb/s channels when driving two MUXes from one J-BERT J-BERT N4903B Up to 14.2 Gb/s data 2 4 6 8 Main data 1 3 5 7 clock N4876A Up to 28.4 Gb/s 1 2 3 4 5 6 7 8 9 Figure 2. Two generator channels are multiplexed by the N4876A, doubling the generator data rate and interleaving the pattern bits from aux data and main data input. Example shows setup with J-BERT N4903B. 2

J-BERT N4903B Clock Infiniium DCA-X 86100D data Main data clock N4876A multiplexer Up to 28.4 Gb/s Transmitter under test Optical or electical Figure 3. Transmitter test setup with N4876A, J-BERT N4903B and Infiniium DCA-X. J-BERT N4903B data N4876A multiplexer Data clock Golden TX or Agilent E/O Up to 28.4 Gb/s Data to J-BERT error detector Attenuator Receiver under test 8164B lightwave measurement system Figure 4. Receiver Tolerance Test Setup with N4876A, J-BERT N4903B using error detector clocked from main clock out and undersampling technique. 3

Specifications N4876A Figure 5. Front panel view of N4876A. Table 1. Specifications for multiplexer s Output data rate Output format Output amplitude Output voltage window External termination voltage 1.25 Gb/s to 27.0 Gb/s (28.4 Gb/s when using J-BERT N4903B option D14) NRZ 0.05 V pp to 1.800 Vpp, 5 mv resolution (for single ended operation) -2.00 V to + 3.00 V - 2.00 V to +3.00 V Output transition times 10 ps typ. (20% - 80%) 15 ps typ. (10% - 90%) Differential skew Intrinsic jitter Jitter feed-through Variable Clk/2 jitter Crossing point Interface Connectors 0 ps typ. 1 ps rms typical with disabled jitter sources and J-BERT N4903B internal clock and clock pattern Transparent for timing jitter on clock (data must be provided accordingly when used with ParBERT). S.I. and ISI shall be added after multiplexer. Notice: after multiplexing 1UI will be 2 UI 45% to 55% or -10 ps to + 10 ps whatever is less. Notice: this means that eye 1 can be up to 10 ps longer/shorter than eye 2 Adjustable 20% to 80% typical Differential or single-ended, DC coupled, 50 Ω impedance 2.4 mm, female Table 2. Specifications for multiplexer inputs Input voltage data inputs Input format Input voltage clock input Interface Connectors Hi-level: 0 V nominal, max: +0.4 V Low-level: -0.8 V nominal, min.: -1.2 V, DC coupled Data: NRZ; Clock: RZ, full-rate 0.4 Vpp nominal, max: 800 mv in +/- 8V window, AC-coupled single-ended, 50 Ω input impedance SMA, female Figure 6. The N4876A allows generating bit streams where even bits have a longer (or shorter) pulse duration than odd bits. (Clock/2 jitter). Example is captured with Agilent 86118A and 86107A precision time base module. 4

Specifications N4876A Table 3. General characteristics Operating temperature Storage temperature Operating humidity Storage humidity Power requirements Physical dimensions (W x H x D) Weight net Weight shipping Recommended recalibration period Warranty period 5 ºC to 40 ºC (-23 ºF to 104 ºF) Auto-adjustment required after warm-up. If operating temperature changes > 5 ºC auto adjustment is needed -40 ºC to +70 ºC (-65 ºF to 158 ºF) 95% relative humidity, non-condensing 50% relative humidity 100V to 240V +/-10%, 50 Hz to 60 Hz, 80 VA Bench top with bumper: 228 x 59 x 360 mm (9.0 x 2.3 x 14.2 in) Rack mount without bumper: 1/2 x 19 width, 1U height: 213 x 44.5 x 360 mm (8.4 x 1.8 x 14.2 in) 2,9 kg (6.4 lb) 5.5 kg (12.1 lb) 1 year recommended. For calibration services see ordering information 1 year return to Agilent. See ordering instructions for extended warranty Control and Programming The N4876A can be controlled via USB interface from J-BERT N4903B user interface or from a stand-alone user interface with programming examples. When using J-BERT with second channel option 002/U02, users can select MUX mode for the AUX DATA to automatically generate a multiplexed pattern stream. Figure 7. Controlling the N4876A multiplexer parameters from a stand-alone user interface. Remote control interfaces: Connectivity: USB 2.0, LAN (rear panel) Programming language: SCPI Via J-BERT N4903B: via USB, required SW rev. 6.7x or later Download the latest software from: www.agilent.com/find/n4876 Stand-alone user interface: System requirements: Microsoft Windows, Agilent IO library suite rev. 15.5, Microsoft.NET 2.0. Figure 8. Rear panel view of N4876A. 5

Specifications N4876A Regulatory standards: Safety: IEC61010-1:2001, EN61010-1:2001, CAN/CSA-C22 No 61010-04, UL 61010-1:2004 EMC: IEC 61326-1:2005, EN 61326-1:2006 Quality management: ISO 9001, ISO 14001 Specification assumptions: The specifications in this document describe the instruments warranted performance. Non-warranted values are described as typical. All specifications are valid in a range from 5 ºC to 40 ºC ambient temperature after a warm-up time of 30 minutes and after Auto-Adjustment. If not otherwise stated, all inputs and s need to be terminated with 50 Ω to GND. All specifications, if not otherwise stated, are valid using the recommended cable set N4910A (2.4 mm, 24 matched pair). Related Agilent Literature Table 6. Related literature for N4876A Publication title J-BERT N4903B Data Sheet Pub number 5990-3217EN 81250A ParBERT Data Sheet 5968-9188E Error Detection up to 28.4 Gb/s using undersampling techniques with J-BERT N4903B, Application Note Learn more www.agilent.com/find/n4876 www.agilent.com/find/contactus 5990-6239EN Ordering Information Accessories included in N4876A-001: three 50 Ω terminations, three adapters 2.4 mm to 3.5 mm, USB cable, UK6 test report, USB stick with getting started guide, user software and documentation Table 4. Ordering information for N4876A 28 Gb/s Multiplexer 2:1 N4876A-001 Recommended accessories 2.4 mm matched cable pair N4910A Matched cable kit for connecting N4876A with J-BERT N4903B (2 x 2.4 mm to SMA for data/aux data, 1x SMA to SMA for clk) Short matched cable pair (2.4 mm (f) to 2.4 mm (f)) for connecting power dividers for external channel addition of N4876A or N4903B data s Power divider 2.4 mm, 50 GHz for external channel addition of two N4876A or N4903B s Rack mount kit Warranty and calibration services Return-to-Agilent (3 or 5 years) On-site (not all geographies) Productivity assistance Rack mount kit N4915A-011 N4915A-012 11636C Recommended J-BERT configuration N4903B with Options C13, 002, and D14 Optional: -J10 (jitter sources) and all others E5810A-100 R1280,R1282 R1288A,R1298A R1380-N49xx E5810A-100 Recommended ParBERT 81250A configuration 1x 81250A-149 13-slot ParBERT mainframe 1x controller (see ParBERT data sheet for options) 1x E4909A clock module 2x N4872A pattern generator module 1x E4875A ParBERT software 6

TM www.agilent.com www.agilent.com/find/n4876 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. http://www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair, reduce your cost of ownership, and move us ahead of your development curve. www.agilent.com/find/advantageservices For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 9276201 For other unlisted Countries: www.agilent.com/find/contactus Revised: October 14, 2010 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011 Printed in USA, March 17, 2011 5990-5247EN www.agilent.com/quality