KEL 24 Cable entry frames

Similar documents
Product group 1. Product description. At a glance. Cable entry systems for entering pre-terminated cables

KVT Split cable glands

KEL 183 Cable entry frames

KVT Split cable glands

Cable entry systems ... p e r f e c t - i n n o v a t i v e - s m a r t

Cable entry systems. perfect innovative smart. Cable entry systems

NEW. Datasheet. Field wiring Cabtite Easy Cable Entry System!

Control cabinet interface and cable entry systems

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

TWINTEC B Signal Circular Connectors

Installation instructions Ex frames

1.2 EUREKA Series... from page c.14

M23 RJ 45 M23 Profinet M16 (10pole)

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

Cable and Pipe Entry Products Cable penetration by design

Installation instructions Roxtec RM ES systems

PKK PKK CHARACTERISTICS. Dimensions. Travel. Travel speed. Acceleration. Temperature. Special versions APPLICATION AREAS. PLE max.

COMBINATION UNITS MARCH 2018

Product information 19" 1U HD Patch Panel 48xRJ45/s, Cat. 6A, gray, fully populated

Installation instructions Roxtec RM BG B systems

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

3M Fiber Closures BPEO

EXPlora. Introduction

Distributed Design Series

Cable ISOBUS Active Termination

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

Grounding-type plugs and sockets K Product information

Installation instructions Cable transit device Roxtec RS ES Ex

Flexible Cord. Inside this section

Installation instructions Roxtec RM PE B

Installation Manual for New or Retrofit Installations

Installation instructions Roxtec RM PE

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Installation instructions Roxtec RM ES B

Installation instructions Roxtec RM ES

EAM PROFIBUS MULTITURN ABSOLUTE ENCODER. Multiturn ABSOLUTE ENCODERS. Presentation. Hardware installation device

Cable entry and cable holding systems Solutions for cable applications

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Ex td A21 IP66 T58 C. max. 3 x 4 mm 2 or 1 x 10 mm 2 with pin cable lug + 1 x 2.5 mm 2 fine wire. max. 4 x M20 metal thread

3M Distribution Box (DDB)

Up to 85% higher Service Life due to efficient sealing method.

Installation instructions Roxtec RM BG systems

03-Durchfuehren_RZ_0708_EN.qxd:03-Durchfuehren GB.qxd :06 Uhr Seite 200 Feed-through

MANUAL CABLE MARKING SYSTEM PMP-30 PUSH-IN CABLE MARKERS WITH HOLDERS

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

Catalog. Industrial Plugs & Sockets The complete range

INSTALLATION INSTRUCTIONS FOR

Connectors for mains connection IEC

Roof-mounted Blue e+ cooling unit Integration solution VX25

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Installation instructions Roxtec RS ES Ex

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

AGRO. The Cable Glands.

Mounting Set ACCESSORIES

Selection matrix for electronic pressure switches

VARIOSOLID Cable entry and Strain-relief systems

PREMIUM 5e F/UTP PRODUCTS

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

7 Lighting Technology


Single Point Flow Monitor SW118 SW119

Size B INDUSTRIAL STANDARD

Ethernet Series. Etherplug Etherlink V Etherlink V Specialty Connectors Specifi cations...

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

TeamWork Installation Guide

Single Pole Devices. Industrial Grade Connectors for Temporary and Semi-Permanent Power Distribution Applications

MAXX BOX. MX102/202 Series. MAXX Box

G.R.A.S. Sound & Vibration

LD OEM/LD PDS/LD PeCo

Bimetal Temperature Switch

Accessories EXTENSION CABLE OPTIONS - HOW TO ORDER. Standard 6-Pin connector type (D60) used with R-Series G-Series. Type DJ.

Connectivity accessories by Nestor Cables

EMC 2 CABLE GLANDS INTRO EMC 2 SERIES. Tighten the cable gland to the housing. Remove outer sheath of shielded cable. Insert cable until EMC spring.

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

HARTING Ethernet cabling cables and connectors, 4 wire

Connecting cables for fieldbuses

D-SUB ACCESSORIES OSSI : CONNECT TO EXCELLENCE D-SUB ACCESSORIES CATALOGUE / EDITION 04 CONNECTORS, PARTS AND EXCELLENCE SINCE 1974

Seal Kits for BUDI Enclosures

SPECIFICATION. Spec No : VSS-1402-CS603B

TECHNICAL SPECIFICATION

Cylindrical Photoelectric Sensor CY-100 SERIES

10 PDUs 19 PDUs Zero-U PDUs

ELECTRICAL. DATA AND INDEX Not all complements shown A shown for reference. Index A leads B, CW (from shaft end) TERMINAL CONNECTIONS COM VCC CASE

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

WLS27 Multicolor LED Strip Light with EZ-STATUS

Connecting cables for valves, Sub-D Type codes

BUS UNITRONIC BUS CAN

EA PROFIBUS SINGLETURN ABSOLUTE ENCODER PRESENTATION HARDWARE INSTALLATION DEVICE SINGLETURN ABSOLUTE ENCODERS EA PROFIBUS

Filters for Power Lines (Low Leakage Current)

SE22HR Small Encoder High Resolution 5V optical encoder up to 2048 CPR

Installation instructions Roxtec CM PE systems

CABLE MANAGEMENT PRODUCTS Cable Managers & Accessories

The FiberMark1 offers an ideal solution for

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

RCA PLUGS & JACKS Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2) Bulk Pkg (2)

EZ-MATE CONNECTORS The Complete Family of Multi-Channel Fiber Optic Connectors for Harsh Environment Deployable Systems

P-2 Installing the monitor (continued) Carry out as necessary

Reference Manual. Notes 9/16 Series H

Transcription:

24 Cable entry frames Split inserts Description Type Order No. Inserts KT PU small large The 24 matches exactly the cut-out dimensions of 24-pole standard industrial connectors. 24 42241 - The split insert matching the cable diameter is placed around the cable and inserted into the cable entry frame. Either a cut out of 36mm or 46mm tall can be chosen depending on the cables being routed. This flexibility is perfect for pre-terminated cables. 24 7 42247 6 1 Retrofitting and maintenance can be carried out easily and quickly High packing density, wide variety of frames and inserts 24 5 42248 5 - Cut-out dimensions Height 36 x 112 mm / page 124 125 17 mm 24 4 42244 2 2 -SNAP SNAP frames -EMC Cable collector KDR2 KDR Base plates FP Flanged plates MP Module plates Page 24 28 Page 17 Page 0 5 Page 6 111 Page 112 6

16 Cable entry frames Split inserts Type Order No. Inserts KT PU Description small large 16 8 42168 8 - The 16 matches exactly the cut-out dimensions of 16-pole standard industrial connectors. The split insert matching the cable diameter is placed around the cable and inserted into the cable entry frame. 16 5 42165 4 1 Either a cut out of 36mm or 46mm tall can be chosen depending on the cables being routed. This flexibility is perfect for pre-terminated cables. 16 4 42164 4 - Retrofitting and maintenance can be carried out easily and quickly High packing density, wide variety of frames and inserts 16 2 42162-2 Cut-out dimensions Height 36 x 86 mm / page 124 125 17 mm -SNAP SNAP frames -EMC Cable collector KDR Base plates FP Flanged plates Page 24 28 Page 17 Page 0 5 Page 6 111 7

Cable entry frames Split inserts Descripton Type Order No. Inserts KT PU small large The matches exactly the cut-out dimensions of -pole standard industrial connectors. 58 32 98,3 83 6 42216 6 - The split insert matching the cable diameter is placed around the cable and inserted into the cable entry frame. 98,3 83 Either a cut out of 36mm or 46mm tall can be chosen depending on the cables being routed. This flexibility is perfect for pre-terminated cables. 58 32 3 42212 2 1 Retrofitting and maintenance can be carried out easily and quickly High packing density, wide variety of frames and inserts Cut-out dimensions Height 36 x 65 mm / page 124 125 17 mm -SNAP SNAP frames -EMC Cable collector Page 24 28 Page 17 8

58 32 - B Cable entry frames Split inserts Type Order No. Inserts KT PU Description small large 72,8 58 - B4 42204 4-58 32 The -B matches exactly the cut-out dimensions of 46 x 46 mm measuring instruments. 72,8 58 The split insert matching the cable diameter is placed around the cable and inserted into the cable entry frame. - B1 42206-1 For routing cables and conduits up to 34 mm diameter. Retrofitting and maintenance can be carried out easily and quickly Space saving shape Small cut-out, high packing density Cut-out dimensions Height 46 x 46 mm / page 124 125 17 mm -SNAP SNAP frames -EMC Cable collector FP Flanged plates Page 24 28 Page 17 Page 6 9 9

- E Cable entry frames Description Type Order Cut-out Inserts KT PU No. [mm] small large The cable entry frames -E are particularly suited for flat connectors. The small frame is ideal for applications with limited space. -E2 42249 43 x 24 2 - For inserting cables up to 17 mm diameter. -E3 42258 65 x 24 3 - Retrofitting and maintenance can be carried out easily and quickly Space saving shape Optimal for D-Sub connectors -E4 42259 86 x 24 4 - Drilling template Height see page 124 125 17 mm 39,5 26,5 -E5 42250 112 x 24 5 - -EMC Cable collector Page 24 25 27

24 - E Cable entry frames Type Order No. Inserts KT PU Description small large 24 15-E 42209 15-1 83,5 13 38 The 24-E offers a larger frame size for routing a greater amount of cables, pipes or conduits. 24 12-E 42208 11 1 1 83,5 13 38 The cable entry frames 24-E series are frames extended with an additional middle frame for routing additional cables. Thus allowing the quick, easy and cost effective routing solution for up to 60 cables. 24 9-E 42207 7 2 1 83,5 13 38 Retrofitting and maintenance can be carried out easily and quickly High packing density Cut-out dimensions Height 62 x 112 mm / page 124 125 17 mm -EMC Cable collector Page 24 28 11

24 - MT Cable entry frames Description Type Order No. Inserts KT PU small large The 24-MT provides additional cable routing possibilities - route up to 80 cables. 2 13 38 38 24 20-MT 42232 20-1 The cable entry frames 24-MT series are frames extended with an additional middle frame for routing additional cables. Thus allowing the quick, easy and cost effective routing solution for up to 80 cables. Retrofitting and maintenance can be carried out easily and quickly High packing density 2 13 38 38 2 13 38 38 24 17-MT 24 14-MT 42224 16 1 1 42225 12 2 1 Cut-out dimensions Height -40 C to + 140 C (static) 82 x 112 mm / page 124 125 17 mm 2 13 38 38 24 8-MT 42221 4 4 1 -EMC Cable collector Page 24 28 12

24-2MT Cable entry frames Type Order No. Inserts KT PU Description small large 24 30-2 MT 24 27-2 MT 42234 30-1 42233 26 1 1 146 13 38 44 38 146 13 38 44 38 The 24-2MT is our largest frame offering with the ability to route up to 120 cables. The cable entry frames 24-2MT series are frames extended with two additional middle frames for routing additional cables. Thus allowing the quick, easy and cost effective routing solution for up to 120 cables. 24 24-2 MT 42227 22 2 1 146 13 38 44 38 Retrofitting and maintenance can be carried out easily and quickly High packing density 24 21-2 MT 42226 18 3 1 146 13 38 44 38 Cut-out dimensions Height -40 C to + 140 C (static) 126 x 112 mm / page 124 125 17 mm 24 12-2 MT 42223 6 6 1 146 13 38 44 38 -EMC Cable collector Page 24 28 13

- FG Flange enclosure Description Type Order No. Inserts KT PU small large The cable entry frames range -FG are suited for installation, sealing and strain relief of pre-terminated cables and conduits at an angle of 90 to the cabinet. -FG A 42320-1 For routing cables and conduits up to 34 mm diameter. -FG A7 42322 6 1 1 Installation at an angle of 90 0 to the cabinet Mechanical protection of cable directly at the place of entry Protection against water spray and drips -FG A4 42324 2 2 1 Cut-out dimensions ABS 36 x 112 mm, page 124 125 -SNAP SNAP frames -EMC Cable collector Page 24 28 Page 17 14 www.icotek.de tel +49 (0) 71 75-923 80 0 fax +49 (0) 71 75-923 80 50

- FG Flange enclosure Type Order No. Inserts KT PU Description small large -FG B4 42330 4-1 The cable entry frames range -FG are suited for installation, sealing and strain relief of pre-terminated cables and conduits at an angle of 90 to the cabinet. For routing cables and conduits up to 34 mm diameter. -FG B1 42332-1 1 Installation at an angle of 90 0 to the cabinet Mechanical protection of cable directly at the place of entry Protection against water spray and drips Cut-out dimensions ABS 46 x 36 mm, page 124 125 -SNAP SNAP frames -EMC Cable collector Page 24 28 Page 17 15

- SNAP SNAP frames Type Order No. Fits Cut-out PU Description for [mm] - SNAP B4 - SNAP 42038 -B -Quick B 46 x 38 42039 46 x 65 The -SNAP frame provides quick assembly of the system when necessary. Control panels already in the factory can be equipped with the -SNAP frame allowing a simple push in of the frame once the associated equipment is delivered to the factory. A cut-out of 46 mm also can be chosen instead of 36mm. Thus pre-fabricated multi pole connectors can be used. - SNAP 16 - SNAP 24 42040 42042 16 -Quick 16 24 -FG A -Quick 24 46 x 85 46 x 112 Upon disassembly (e.g. maintenance) screwing and unscrewing of -frame is not necessary Previously assembled frames are quickly and easily attached Integrated gasket in SNAP-frame Drilling template identical to -frame (except -SNAP B4) - SNAP 24E 42044 24-E 71 x 112 1 Drilling template IP 54 see page 124 125 - SNAP 24MT 42046 24-MT 89 x 112 1 Cable entry frames -QUICK Cable entries MP Module plates BPK-SNAP Blind plates Page 6 15 Page 36 < 37 Page 112 Page 116 17

21 KT Inserts, small 21 Description Type Order No Order No Clamping range PU grey black BTK BTK 41251 41351 Blind insert KT cable inserts small are used with the following cable entry frames: - Page 6-13 -FG - Page 14-15 KVT - Page 18-21 KVT-W90 - Page 22 The model range KT small is designed for cable diameters from 2 to 17mm. Assembly When installing the insert, the smooth side of the insert faces the middle of the cable entry frame. KT grey Elastomer - 40 C to+ 90 C (static) KT KT 2 39934 42 2-3 mm KT 3 41203 43 3-4 mm KT 4 41204 44 4-5 mm KT 5 41205 45 5-6 mm KT 6 41206 46 6-7 mm KT 7 41207 47 7-8 mm KT 8 41208 48 8-9 mm KT 9 41209 49 9 - mm KT 412 413-11 mm KT 11 41211 41311 11-12 mm KT 12 41212 41312 12-13 mm KT 13 41213 41313 13-14 mm KT 14 41214 41314 14-15 mm KT 15 41215 41315 15-16 mm KT tele KTs 16 39901 39912 16 mm KTs 17 39900 39913 17 mm KT black KT oval KT tele 39929 - Telephone cable Elastomer UL-94 HB - 30 C to + 90 C (static) higher chemical resistance, UV-stabilized KT S1 KT oval 39930 - approx. 8 x 4 mm KT S1 39931-24

21 KT Inserts, small 21 Type Order No Order No Clamping range PU Description grey black KT 2 2 39935 39936 2x ø 2 mm KT 2 x KT 2 3 39939 39940 2x ø 3 mm KT 2 4 39906 39907 2x ø 4 mm KT 2 5 41200 39904 2x ø 5 mm KT 2 6 41201 39905 2x ø 6 mm KT cable inserts small are used with the following cable entry frames: KT 2 7 41202 39916 2x ø 7 mm KT 2 8 39917 39918 2x ø 8 mm KT 4 2 39937 39938 4x ø 2 mm KT 4 3 39914 39915 4x ø 3 mm KT 4 x - Page 6-13 -FG - Page 14-15 KVT - Page 18-21 KVT-W90 - Page 22 The model range KT small is designed for cable diameters from 2 to 17mm. KT 4 4 39909 39911 4x ø 4 mm KT 4 5 39908 399 4x ø 5 mm KT 4 6 39932 39933 4x ø 6 mm KT ASI2 rl KT-ASI 39902 39903 1 ASI-cable KT-ASI2 rl 39922 39924 2 ASI-cables KT-ASI2 ll 39921 39923 2 ASI-cables Assembly When installing the insert, the smooth side of the insert faces the middle of the cable entry frame. KT grey KT ASI2 ll Elastomer - 40 C to+ 90 C (static) KTRS 12 39990 - KTRS KTRS 13 39992 - KTRS 16 39996 - KT black Elastomer UL-94 HB - 30 C to + 90 C (static) higher chemical resistance, UV-stabilized 25

KT Inserts, large 41,5 42 Description Type Order No. Order No. Clamping range PU grey black ATG ATG 41253 41353 Adapter insert The KT inserts large accept a wide range of cable diameters from 16 to 34 mm. They are used with the following cable entry frames: - Page 6-13 -FG - Page 14-15 KVT / KVT-W90 - Page 18-22 183 - Page 32 BTG BTG 41252 41352 Blind insert or 5-20 mm ATG adapter inserts provide the possibility to hold a small KT insert to reduce the clamping range down to 2 mm. KT 28 KT 16 41216 41316 16-17 mm KT 17 41217 41317 17-18 mm KT 18 41218 41318 18-19 mm KT grey Elastomer - 40 C to+ 90 C (static) KT 19 41219 41319 19-20 mm KT 20 41220 41320 20-21 mm KT 21 41221 41321 21-22 mm KT 22 41222 41322 22-23 mm KT 23 41223 41323 23-24 mm KT 24 41224 41324 24-25 mm KT black KT 25 41225 41325 25-26 mm KT 26 41226 41326 26-27 mm Elastomer UL-94 HB - 30 C to + 90 C (static) higher chemical resistance, UV-stabilized KT 27 41227 41327 27-28 mm KT 28 41228 41328 28-29 mm KT 29 41229 41329 29-30 mm KT 30 41230 41330 30-32 mm KT 32 41232 41332 32-33 mm KT 34 41234 41334 33-34 mm 26

21 41,50 KTMB Inserts, multi-range 21 42 KTMB large KTMB small Type Order No. Size Clamping range PU Description grey KT KTMB-A 41432 KT small 2.5-6.5 mm KTMB-D KTMB-B 41434 KT small 4.0-7.5 mm KTMB-C 41436 KT small 6.5 - mm KTMB-D 41438 KT small 9.5-13 mm KTMB The KTMB inserts accept a wide range of cable diameters. A great benefit when exact cable diameter is not known in advance. The KTMB inserts are not split and therefore only usable for cables without connectors. KTMB-E 41440 KT small 13-16 mm Cross section KTMB KTMB grey KTMB-G 41460 KT large 13-18 mm KTMB-H 41465 KT large 18-23 mm Elastomer - 40 C to+ 90 C (static) KTMB-I 40 KT large 23-28 mm KTMB-J 45 KT large 28-33 mm The correct size of the KT inserts can easily be determined by using the cable template. Determining the diameter of the cable using the cable template Selecting the KT inserts according the data on the cable template KTMB-K 41480 KT large 2x 13-18 mm Order-No. 39800 27

DT Cable entry inserts Description Type Order No. Number of PU cables The DT cable inserts are designed for standard cables (without connectors). A large number of cables can be routed utilizing minimal space. DT 1 41500 12x max. 6.5 mm 2x max. 12.2 mm DT inserts are designed to fit in KT large insert spaces: 24 16 -B - Page 6-9 24 Extensions - Page 11-13 -FG - Page 14-15 183 - Page 32 DT 2 415 16x max. 7.1 mm DT 3 41520 4x max. 6.5 mm 3x max. 9.5 mm 3x max. 11.3 mm Combination of routing pre-terminated and standard cables with one cable entry frame Enables a sub-assembly of cable harnesses High packing density DT 4 41530 9x max. 9.5 mm Elastomer IP 54-40 C to + 90 C (static) 28

ST Plugs Type Order No. Diameter Length PU Description D L ST 2 42909 2.0 mm 25 mm 25 ST 3 42901 3.0 mm 25 mm 25 ST 4 42908 4.0 mm 25 mm 25 ST 5 42906 5.0 mm 25 mm 25 ST 6 42903 6.0 mm 25 mm 25 Plugs are used to close either KT inserts or -DPZ cable entry plates not equipped with cables. Perfect for appplications where cables have been removed. ST 7 42905 7.0 mm 25 mm 25 ST 8 42899 8.0 mm 20 mm 25 ST 9 42897 9.0 mm 20 mm 25 ST 42895.0 mm 20 mm 25 Sealing unused cable entries ST 11 42893 11.0 mm 20 mm 25 ST 12 42891 12.0 mm 20 mm 25 ST 13 42889 13.0 mm 20 mm 25 ST 14 42887 14.0 mm 20 mm 25 ST 15 42885 15.0 mm 20 mm 25 ST 16 42883 16.0 mm 20 mm 25, white IP 54-40 C to + 120 C ST 17 42881 17.0 mm 20 mm 25 ST ASI 42877-25 mm 25 KT + DT Cable inserts Cable entry plates DPZ Cable entry plates DP Page 24+25 28 Page 46 51 Page 52 54 29

- FL Cable entry for flat cables Description Type Order Cut-out Inserts PU No. [mm] KT FT - FL A 460 43 x 24 0x KT 1x FT - 1 The - FL range enables a simple, fast and flexible cable routing and sealing of flat wires. Split or non-split inserts can be utilized. - FL B 465 65 x 24 0x KT 1x FT - 2 Innovative construction of the inserts compensates for manufacturing inconsistencies in flat cables. - FL C 461 65 x 24 1x KT 1x FT - 1 - FL D 46115 86 x 24 0x KT 1x FT - 3 Routing of flat cables in combination with pre-terminated round cables by using a single cable entry frame Space saving shape - FL E - FL F 46120 86 x 24 46125 86 x 24 1x KT 1x FT - 2 0x KT 2x FT - 1 - FL G 46 86 x 24 2x KT 1x FT - 1 Drilling template see page 124 125 - FL H - FL I 46135 112 x 24 46140 112 x 24 2x KT 1x FT - 2 1x KT 2x FT - 1 - FL J 46145 112 x 24 3x KT 1x FT - 1 FT Cable inserts, flat, small -EMC Cable collector Page 31 Page 24 25 - FL K 46150 112 x 24 1x FT - 1 1x FT - 2 - FL L 46155 112 x 24 1x FT- 4 30

FT Inserts for flat cables Type Order No. Clamping range PU Description grey FT - 1 0 46201 Blind insert 5 FT - 1 A 462 Width: 19.0-23.0 mm Thickness: 5.5-6.0 mm 5 The range of FT inserts are used to route flat cables. Suitable cable entry frames are the -FL range (see page 30). FT - 1 B 46211 Width: 28.0-33.0 mm Thickness: 5.5-6.0 mm 5 Innovative construction of the inserts compensates for manufacturing inconsistencies in flat cables. FT - 1 C 46212 Width: 24.0-30.0 mm Thickness: 8.5-9.0 mm 5 FT - 2 0 46202 Blind insert 5 Routing of flat wires with various dimensions FT - 2 A 46250 Width: 32.5-38.0 mm Thickness: 5.0-5.5 mm 5 FT - 2 B 46251 Width: 45.0-50.5 mm Thickness: 6.0-6.5 mm 5 Specifi cation FT - 2 C 46252 Width: 47.0-52.0 mm Thickness: 9.5 -.0 mm 5 Elastomer - 40 C to + 90 C (static) FT - 3 0 46203 Blind insert 5 FT - 3 A 46300 Width: 72.0-77.0 mm Thickness: 5.0-5.5 mm 5 FT - 4 A 46330 Width: 85.0-99.0 mm Thickness: 4.2-5.2 mm 5 -FL Cable entry frames Page 30 31