F70series. Variation. Excellent detection performance

Similar documents
Type F70AB F70ABPN. Digital display. Simple operation featured

Type. NPN output F71R F71G F71B F71W F71RH F71GH F71BH F71WH. Manual setting general-purpose type. Manual setting high-speed type

SU17 Series Fiber Optic Sensors

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

SA1J-F: Full Color Fiber Optic Sensors

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Photoelectric Sensors E3F2

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Photoelectrics Through-beam Type PA18C.T..., DC

Cylindrical Photoelectric Sensor CY-100 SERIES

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Digital Fiber Amplifier E3X-DA51. Ordering Information. Digital Fiber Amplifier Provides High Performance and Ease of Use

Detect Color and Shape for various inspection

Electrical connection

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Solid-State Digital Timer

Amplifier for fiber optics. Dimensioned drawing

UV Power Monitor. incident light 200 to 370 nm 300 C (Use at temperatures below the Fiber Unit s rated operating

Electrical connection

Safety Light Curtains GuardShield

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

SERIES. Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button.

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Absolute Rotary Encoder E6CP

Operating Instructions

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

V 180 Series Photoelectric Switches

LUT Luminescence scanners: Seeing what no-one else can

Amplifier for fiber optics. Dimensioned drawing

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Super Side. Sense type

Operating instructions Retro-reflective sensor. OJ50xx laser / / 2010

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

AUTOMATIC SETTING TYPE OPTICAL FIBER PHOTOELECTRIC SENSORS. Long Sensing Range. The standard M4 fiber offers the sensing range of 600mm inch.

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

WF next: Fork sensors for a wide range of applications

Digital Flow Switch for Large Flow

Separate Thin Amplifier type. AP-V40AW Series

E3X-DA-S An Extensive of Standard Functions to Support the World's Highest Level of Stable Detection.

60 ± 10 mm 4. (See Note.) PNP E3MC-X ± 4mm 4 NPN E3MC-MX11. (See Note.) PNP. mended. fiber. 4 NPN E3MC-MY11 E32-T16

Operating instructions Through-beam sensor. OJ51xx / / 2004

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

SPACESCAN SERIES SS 02

Electrical connection

Sensors. SA1J: Full Color Recognition Sensors. General Specifications. Q-4 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC

Safety Light Curtain Type4 SIL3 PLe

Scanning Laser Range Finder Smart-URG mini UST-10LX (UUST003) Specification

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF310-Q8

Safety Light Curtains

APPLICATIONS. Automatic warehouse. Trasportation lines

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

LED Type Optical Displacement Sensor

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF300-Q8

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XTKLAF100-Q8

SAUTER flexotron RDT405 Manual

Electrical connection

Contact-Type Digital Displacement Sensor. HG-S Series. User's Manual WUME-HGS panasonic.net/id/pidsx/global

NPN type (Analogue/Voltage/Dual) Laser type. PNP type (Analogue/Voltage/Dual) NPN type (RS422) PNP type (RS422) Pins configuration

Photoelectric sensor Laser Distance Sensor (Triangulation) Q4XFKLAF610-Q8

W100L: Laser Sensor in Mini- Format

DF-G3 Long Range Expert Dual Display Fiber Amplifier

Light Curtain Type LA

Ø50mm Shaft Multi-Turn Absolute Type

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Multifunction Digital Timer

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

Manual teaching. Place a workpiece bearing the reference color under the fiber head and press the teaching button. Teaching button

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

EVENT INPUT/OUTPUT MODULE [PUME]

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

CDX series. World s No. 1 Linearity OPTEX FA CO., LTD. New models added. Ultra High-Accuracy Laser Displacement Sensor

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Panel-mounting thermostats, type series EM

Vision Sensor Short Manual

Gamma instabus. Technical product information

NEW. Safety Light Curtain. MS4800 Series. Strong, Durable Body and Long, 20-m Sensing Distance

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

Selection matrix for electronic pressure switches

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Pressure Sensor. Ordering Information. Mini-Cube Pressure Sensor with Easy-to-Read LED Display

Magnetic Sensor - Incremental EHP

W 9-2: A Versatile, Complete and Compact Series

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Figure 1: Standard 906 Sensor and Pulser Disc. Figure 2: Standard 906 Sensor and Pulser Wrap

Luminaire installation box Surface-mounted box Ceiling installation box

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Transcription:

F70series Digital display Fiber optic sensors Digital indication of sensing information arious advanced functions provide for optimum use of the sensor Unparalleled high resolution allows highly accurate detection CD with backlight for ease of reading onger detecting distance (about -X that of a conventional Takex model) ariation Type Digital display high-performance type NPN output PNP output F70R F70RPN F70G F70GPN F70B F70BPN F70W F70WPN ight source Red ED Green ED Blue ED White ED Output mode Open collector (NPN/PNP) Excellent detection performance Wide dynamic range and high resolution are achieved at the same time High resolution is maintained even with a wide dynamic range. The provided electronic volume feature has both a wide dynamic range and high resolution. (6) 8-position sensing indication with electronic volume Buitl-in high-resolution provides highly accurate detection The electronic-volume frequently switches the sensitivity range, each of which is divided into 10 levels. 10 evel Resolution of 10 1 3 5 6 7 8 Detecting distance Position on sensitivity volume Self-diagnosis stability indication Operation/ timer mode indicated Function mode indicated ight emission frequency channel switched foranti Mutual Interference feature

F70 Display function :(beyond received light level) Displacement indication function All amplifiers should show 0 with no work. Possible failure Failure such as light intensity degradation possible if a negative value is shown. The value for a deviation (positive or negative) of received light level from the original level is shown at the time of detection, which allows central management of sensors. Absolute value indication Received light level indication going beyond the 9999 10 evel 1 3 Full range shown in values between 0 and 9999 5 6 Resolution of 10 7 Position on electronic volume Detecting distance If the received light level at light blocking is 10 and the level at light reception is 6000, the light blocking / light reception ratio is calculated as 600 times. 8 supporting high resolution Enhanced teaching features (sensitivity setting) Full auto teaching Simply pressing the button allows easy teaching of an object moving at a high speed. The teach hold feature allows indication of the maximum and minimum data. Auto teaching -point teaching with and without the presence of work, allows the detection of slight level differences such as the thickness of a piece of work and/or the presence of a film. Positioning teaching This feature is ideal for high-accuracy positioning that requires accurate determination of a detecting point. Maximum sensitivity setting For applications requiring a maximum sensitivity setting such as the detection of work with a through-beam typefiber optic cable. The incorporated extra powerful light would allow use in an adverse environment. Manual setting Arbitrary manual increase and decrease of a set-point level allows level setting while checking the operation. Auto sensing function compensates for adverse environment The level of received light is constantly monitored and fluctuation is detected and automatically adjusts the activation/deactivation level. Stable detection at optimum sensitivity is ensured even if the received light level frequently fluctuates due to dust or water drops. Manual hysteresis setting feature The hysteresis can be arbitrarily set according to the application, allowing setting of a small hysteresis for severe, high-accuracy detection and a large hysteresis for detection of large variation and prevention of chattering. Timer functions On-delay, off-delay and on-off delay timer functions are provided, which allows for a wide range of detecting and input conditions from the connected devices. The delay time setting is variable between: 10 ms, 0 ms, 0 ms, 60 ms, 80 ms, 100 ms and 10 ms. Teach hold function The sensor has the ability to hold instantaneous data for an object moving at a high rate of speed during full auto teaching. This data is displayed when the teaching has been completed. (Data for light reception is 35 and for light blocking 10.)

F70AF70series Type Amplifier (main unit) Type NPN output PNP output ight source Output mode Connection F70AR F70ARPN Red ED Digital display F70AG F70AGPN Green ED general-purpose type Digital display F70AB F70AW F70R F70G F70ABPN F70AWPN F70RPN F70GPN Blue ED White ED Red ED Green ED Open collector (NPN/PNP) Permanently attached cord M8 connector type also available high-speed type F70B F70BPN Blue ED F70W F70WPN White ED Fiber optic cable For different types of fiber optic cables, see pp. 59-. M8 connector type M8 connector connection type is separately available for all models, which is identified by -J following the model number. -JE and -JS are available depending on the input/output specification. For connector specifications, see p. 3. <Type of cords with M8 connector> FBC-RS (equipped with straight M8 connector and -m cord) FBC-R (equipped with angled M8 connector and -m cord) End unit Optional parts Type End unit Mounting bracket* *Accessory FA7EU AC-BF Description DIN rail mounting stopper Amplifier unit mounting bracket

F70AF70series Rating/Performance/Specification Rating/performance Specification NPN type PNP type Power supply Current NPN type consumption PNP type Control NPN type output (*) PNP type Stability NPN type output (*) PNP type Operation mode Output mode Timer Response time ight source (wavelength) Indicator Display Switch Sensitivity setting Sensitivity setting input Sensitivity adjustment function Functions F70AR F70ARPN F70AG F70AGPN F70AB F70ABPN F70AW F70AWPN F70R F70RPN F70G F70GPN F70B F70BPN F70W F70WPN 1- DC 10% / Ripple 10% max. 39 ma max. 50 ma max. Open collector output / Rating: sink current 100 ma (30 DC max.) / Residual voltage: 1 or less Open collector output / Rating: source current 100 ma (30 DC max.) / Residual voltage: or less Open collector output / Rating: sink current 50 ma (30 DC max.) / Residual voltage: 1 or less Open collector output / Rating: source current 50 ma (30 DC max.) / Residual voltage: or less ight-on/dark-on selectable Off delay/disabled selectable On delay/off delay/on-off delay/disabled selectable Delay time: 0 ms fixed Delay time: selectable between 10, 0, 0, 60, 80, 100 and 10 ms / Default: 0 ms ight emission frequency channel 1: 600 s max. ight emission frequency channel : 700 s max. Red ED Green ED Blue ED White ED (660mm) (55mm) (70mm) ight emission frequency channel 1: 500 s max. ight emission frequency channel : 600 s max. Red ED Green ED Blue ED White ED (660mm) (55mm) (70mm) Operation indicator: orange ED / Stability (STB) indicator: green ED CD display with backlight set buttons / Mode selector switch: /SET set buttons / Mode selector switch: // Full auto teaching / Auto teaching Set button input Set button input/external input Provided (manual sensitivity adjustment) Anti Mutual Interference feature Short circuit protection feature Sensor function: AUTO/TEACH/OCK Auxiliary function: S for manual adjustment of sensitivity and activation level H for manual hysteresis setting for displacement indication and absolute value indication modes Anti Mutual Interference feature Self-diagnosis feature Short circuit protection feature Material Connection Mass Accessory Polycarbonate Permanently attached cord (outer dimension: dia..8) 0.sq. 3 core m length Permanently attached cord (outer dimension: dia..8) 0.sq. 5 core m length For M8 connector specifications, see p. 3. Approx. 80 g (including -m cord and mounting bracket) Mounting bracket / Operation manual (*) Avoid the transient condition (0.5 seconds) immediately after power-up for output. Environmental Specification Environment Ambient light Ambient temperature Ambient humidity Protective structure ibration Shock Incandescent lamp: 10,000 lx / Sunlight: 0,000 lx 1-3 adjacent units in operation: 5-55 C -10 adjacent units in operation: 5-50 C 11-16 adjacent units in operation: 5-5 C Storage: 0-70 C (non-freezing) 35-85%RH (non-condensing) IP0 10-55 Hz / 1.5 mm amplitude / hours each in 3 direction 500 m/s / 3 times each in 3 directions

Input/Output Circuit and Connection Output circuit diagram NPN output type F70AR F70ABK Brown: 1- DC F70AG F70AB F70AW F70ARK F70AGK F70AWK Blue: 0 PNP output type F70ARPN F70ABKPN Brown: 1- DC F70AGPN F70ABPN F70AWPN F70ARKPN F70AGKPN F70AWKPN Blue: 0 NPN output type F70R F70G F70B F70W Brown: 1- DC Orange: STB OUT Blue: 0 Pink: external teaching (*) PNP output type F70RPN F70GPN F70BPN F70WPN Brown: 1- DC Orange: STB OUT Pink: external teaching (*) Blue: 0 PNP output type F70RKPN F70GKPN F70BKPN F70WKPN Brown: 1- DC Orange: STB OUT Blue: 0 (*) When not using external teaching, cut the pink lead at the base or connect it to the positive terminal (for NPN type) or 0 (PNP type) of the power supply.

Input/Output Circuit and Connection Output circuit diagram NPN output type F70RK F70GK F70BK F70WK F71R F71G F71B F71W F71RH F71GH F71BH F71WH F71RK F71GK F71BK F71WK F71RHK F71GHK F71BHK F71WHK Brown: 1- DC Orange: STB OUT Blue: 0 PNP output type F71RPN F71GPN F71BPN F71WPN F71RHPN F71GHPN F71BHPN F71WHPN F71RKPN F71GKPN F71BKPN F71WKPN F71RHKPN F71GHKPN F71BHKPN F71WHKPN Brown: 1- DC Orange: STB OUT Blue: 0 M8 Connector Type IO Specification/Pin Arrangement/ead Colors F70A J N.C (unused) White Control output Black F70 JE External teaching output White Control output Black 1- DC 1 3 0 1- DC 1 3 0 Brown Blue Brown Blue F71 J Stability output White Control output Black F70 JS Stability output White Control output Black 1- DC 1 3 0 1- DC 1 3 0 Brown Blue Brown Blue Dimensions of cord with M8 connector (optional) (in mm) FBC-RS (straight) FBC-R (angled) 000 000 30.7.5 55 7 3 55 7 9 Color: black 3.7 16 Color: black 9

Common to F70A/F70/F71 Series Handling of amplifier case cover Opening the case cover While pressing down the front part of the case cover, lift the cover by pulling up the tab. Just roughly pulling the case cover tab for opening may damage the cover. Be sure to press the front part of the cover when pulling the tab. Attachment of amplifiers for joined use When using two or more amplifiers by joining them together, be sure to use a DIN rail for mounting. Up to 16 units can be joined for use. Be sure to cut the power supply before attempting to join or separate units. Mount one amplifier at a time on the DIN rail while keeping a certain space between amplifiers. Press down The cover opens up to the connector on the back and stays at the half-opened position. Pull Pulling at the hinge with the cover half open allows removal of the cover. Slide the amplifiers so that the tabs on the front and the connector pins on the back are respectively joined together. Connector pin Cover removed Tab Attaching the cover Put the case cover on the amplifier as shown on the figure on the right and push in at the hinge. Press down the front part of the cover until it clicks and make sure that the tab is hooked. Click Press Press To prevent the connections from coming loose due to vibration, etc., attach end units (optional) on the ends of the group of amplifiers to secure them. Attaching amplifier on DIN rail or mounting bracket The mounting bracket is optional. The amplifier cannot be side-mounted with a mounting bracket used. End unit Attachment Put the front hook of the amplifier on the rail (or mounting bracket) and press down the back of the amplifier. Press down To detach the amplifiers, follow the steps in reverse order and remove one amplifier at a time. Removing the amplifiers as they are joined together without sliding may damage the amplifiers. Detachment While pressing the amplifier forward, lift the front part and detach the front hook. Press

Common to F70A/F70/F71 Series For Correct Use Be sure to follow the instructions in the operation manual provided for correct use of the product. Attachment of fiber optic cable Attachment to amplifier 1. Open the case cover and press down the single-touch lock lever. Attachment of small-diameter fiber optic cable When attaching a small-diameter fiber optic cable, use the adapter that comes with the fiber optic cable. Adapter Receiver Transmitter. Insert the fiber optic cable all the way until it stops. To prevent inadequate insertion of a fiber optic cable, marks to indicate the insertion length are provided on the case side, which can be used as gauges. Attachment of coaxial reflective fiber optic cable Attach the multi-core fiber to the receiver and single-core fiber to the transmitter. Multi-core fiber Fiber optic cable insertion length: about 13 mm Receiver Transmitter Single-core fiber Notes on usage When using two or more amplifiers joined together, be sure to use a DIN rail for mounting. Different ambient temperatures apply according to the number of joined amplifiers. No. of amplifiers 1-3 -10 11-16 Ambient temperature 5-55 ºC 5-50 ºC 5-5 ºC Be sure to turn off the power supply before wiring. To extend the cord, use wires of at least 0.3 mm and limit the length to within 100 m. Using the same conduit for the amplifier wiring and power transmission or high-voltage lines may cause faulty operation or damage due to noise. Be sure to route them separately. Make sure that the power fluctuation is within an allowable range so that the power input will not exceed the rating. When using a commercially-available switching regulator, use the frame ground or ground terminal. For output, avoid the transient condition (0.5 seconds) immediately after power-up. Do not use the sensor in a place subject to steam, large amount of dust or direct exposure to water or oil. Do not use the sensor outdoors or in a place subject to direct disturbing light on the light receiving surface. Use of a reflective-type fiber optic cable at the maximum sensitivity may cause inadequate light blocking. Be sure to use a work for sensitivity setting.

F70Series For Correct Use Be sure to follow the instructions in the operation manual provided for correct use of the product. Part names Stability indicator Green ED CD display Set button Set button Operation Mode selector switch Sensor function Functions as an ordinary sensor. Operation indicator Orange ED CD display Shows the status and functions of the sensor including operation mode and received light level. Operation mode Position on the electronic volume 8-step indication: 1,,...8 ight-on DDark-ON OOn delay FOff delay D D Function Sensor function A: Auto sense T: Teaching : ock Initial (factory) setting Received light level AT 1 SH ight emission frequency channel When a fiber optic sensor has been mounted and power supplied for the first time, indications as shown below appear with the corresponding settings enabled: ight-on Simple setting for immediate use (For reflective type) TAKEX F70R Position on electronic volume: 8 1Press Button 1 once with no work present. The orange and green indicators flash. With the work in place, press Button 1 once again. (For through-beam type) AT 1 SH Stability indicator Operation indicator CD display Operation mode Position on electronic volume Received light level Function ight emission frequency channel Mode selector switch 1Block the light beam with the work, etc. to set the light blocking state. Press Button 1 twice. The setting is complete. Mode selector switch Auxiliary function S: manual adjustment of sensitivity and activation level H: manual hysteresis (deactivation level) setting : displacement indication and absolute value indication T 1 Work Received light level Teaching mode Note Use of a reflective-type fiber optic cable at the maximum sensitivity may cause inadequate light blocking. Be sure work is present for auto or full auto teaching. Teaching with Button 1 D Operation mode setting Select between ight-on and Dark-ON and timer operations. 1Set the switch from to. Select function Selection of ight-on/dark-on and timer operation. Selection of sensor function. Selection of auxiliary function. Mode function Sensitivity setting (teaching) in the lock mode Activates the auxiliary function selected in [] TAKEX AT 1 SH Press Button. The indication rotates in the order shown below by one step every time the button is pressed. D D D D O F O F 1 This position for ordinary detection Teaching Teaching with Button 1 1 Output selection with Button D AT 1 SH TAKEX F70R Operation mode selection Auxiliary function selection with Button 1 D TAKEX F70R AT 1 SH 1 1 Indication Output operation Timer operation O F O F D D O D F D ight-on ight-on ight-on ight-on Dark-ON Dark-ON Dark-ON Dark-ON None On delay On delay On/Off delay None On delay Off delay On/Off delay T Teaching Auxiliary function operation Set from to for teaching mode 1 3Select a desired mode and set the switch back to, which enables the selected operation mode. Or Teaching with Button 1 1

F70Series For Correct Use Be sure to follow the instructions in the operation manual provided for correct use of the product. Sensor function/auxiliary function setting A Sensor function Sensor function selection 1Set the switch to. Press Button 1 The indication rotates in the order below by one step every time the button is pressed, allowing the selection of a sensor function and auxiliary function. 3) Select a function and set the switch back to []. The function selection is stored in the memory. A: Auto sense mode Constantly monitors the level of received A A light and, if any variation is found, the on/off level is automatically adjusted. The adjusted on/off level is not stored in the memory. The initial data is applied when the power supply is cut off once and supplied again. T: Teaching mode Allows sensitivity setting.the setting T T method options include auto teaching, full auto teaching and external signal. : ock mode Prohibits sensitivity setting. A T Displacement indication mode TAKEX F70R AT T1 SH A T T S H A T The level of received light with the work used is indicated in positive or negative value (displacement) with reference to the level of received light at the time of teaching. Sensitivity setting (teaching) Auto teaching (with stationary work) 1Press Button 1 with no work placed and release the button. The indicator flashes, showing that the sensor is ready for the next teaching input. With the work in place, press Button 1 once and release it. The indicator stops flashing, showing that sensitivity setting is complete. Full auto teaching (with moving work) 1) Press and hold down Button 1 for 3 seconds or longer. The orange and green indicators start flashing alternately and the flashing becomes slower a little later. ) et the work pass while holding down Button 1. 3) When the passing of work and the slow flashing of indicators have been confirmed, release Button 1. Set button 1 = ON (press) Flash, flash, flash, flash Positioning teaching Flash, flash Flash, flash Flash, flash About 3 seconds et work pass in this period 1) Place the work at the desired position. ) Press Button 1 twice, which completes the positioning. T 1 For reflective type For reflective type Work Auxiliary function Auxiliary function selection S: Allows adjustment of the sensitivity and activation level already set. S H: Allows adjustment of the hysteresis (deactivation level). H : Indicates the absolute value. T 1 Teach hold function Holds momentary data during full auto teaching. Releasing Button 1 shows the maximum and minimum data during teaching (the maximum and minimum values are Maximum value Work Minimum value alternately shown for about 3 seconds). This hold function is not available with the external teaching function. Select one of these functions and set the switch to [], which enables the auxiliary function selected. CD display The received light level displayed on the CD shows an average value for a certain period of time and may contain an error of 1-. When the Anti Interference feature is enabled, the received light level indication on the CD may show an incorrect value. For correct indication, eliminate the interference by blocking the light causing the interference or cutting of the power supply to the sensor causing the interference and read the value.

Cord-Connected Type Dimensions (in mm) Amplifier F70A/F70 Series F 71 Series (Common) 9 60 3 Receiver Transmitter 5 9 30.7 3 8 (1) 16 11.5 36.5-3. hole Mounting bracket 1 16-3.5. oval hole.8 cord ( m in length) M8 connector type 8 11 M8 connector (For dimensions of connector cords, see p. 3.) For dimensions of fiber optic cables, see pp. 67-.