INSTRUCTION SHEET FOR NOISE MEASUREMENT

Similar documents
Performing a Sound Level Measurement

Is INTERNATIONAL STANDARD. Acoustics - Measurement of the in sifu sound attenuation of a removable screen

Performing a Measurement/ Reading the Data

PSM-003. Micro Polarization Controller/Scrambler. User Guide

Mr. Chris Cocallas University Architect and Director Capital Planning and Construction Colorado School of Mines th St. Golden, Colorado 80401

Determination of Sound Quality of Refrigerant Compressors

FC Cincinnati Stadium Environmental Noise Model

6 3 0 N M, S I N G L E M O D E F U S E D F I B E R O P T I C C OUPLERS / TA P S

I. LISTENING. For most people, sound is background only. To the sound designer/producer, sound is everything.!tc 243 2

Questions and Comments to Discuss with Staff

VOX. Operating manual VOX VOX-01 VOX. IEC rev. 4 IEC Class 2 / ANSI S1.4 Type 2 SPEECH INTELLIGIBILITY TESTER

OFI Optical Fiber Identifier User s Guide

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Acoustic concert halls (Statistical calculation, wave acoustic theory with reference to reconstruction of Saint- Petersburg Kapelle and philharmonic)

Alternative Fiber Coupler Options

Live Sound System Specification

User s Manual. Model Digital Sound Level Meter

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

REPORT NO CRT-001h SOUND OUTPUT MEASUREMENTS ON SIX INVERTER GENERATOR SAMPLES RENDERED TO

MODEL PA II-R (1995-MSRP $549.00)

SNG-2150C User s Guide

Getting Started with the LabVIEW Sound and Vibration Toolkit

University of North Carolina at Charlotte Student Union Event Policy

K Service Source. Apple High-Res Monochrome Monitor

BBN ANG 141 Foundations of phonology Phonetics 3: Acoustic phonetics 1

PSYCHOACOUSTICS & THE GRAMMAR OF AUDIO (By Steve Donofrio NATF)

Signal Processing. Case Study - 3. It s Too Loud. Hardware. Sound Levels

Calibration of auralisation presentations through loudspeakers

446 Crestcourt Lane, Fallbrook CA phone fax

DETECTING ENVIRONMENTAL NOISE WITH BASIC TOOLS

2.4GHz Digital Wireless Video Door Phone User Manual

In-Line or 75 Ohm In-Line

Coopers Gap Wind Farm AGL Energy Ltd 23-Aug-2016 Doc No AC-RP-02- Facade Sound Insulation Test Report

Product Data Sheet 4650 N-465

HPA-8 8 Channel Headphone Amplifier. Owner s Manual

MANUAL ENGLISH Core Club Ordercode: D2314

900-Lumen Portable LED Projector Part #: User manual

Modular operating rooms Sundsvall Regional Hospital

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Binaural Measurement, Analysis and Playback

PL2410W LCD Monitor USER'S GUIDE.

Quick Setup 1 Unpack the projector

ROUGH DRAFT. Guide. Installation. Signal Booster. Wilson. AG Pro 75 Smart Technology In-Building Wireless 800/1900 Signal Booster.

2 Connect your video source

2 Connect your video source

Ambient Weather WS-01 Intelligent Color Changing Temperature Night Light with Ambient Backlight User Manual

Software Package WW 9038 for the Sound Intensity Analysing System Type 3360 or the Digital Frequency Analyzer Type 2131

Liquid Mix Plug-in. User Guide FA

IM-53 Installation Mixer ORDERCODE D2178

We realize that this is really small, if we consider that the atmospheric pressure 2 is

Fully ly Automaticti. Motorised Satellite t TV System. User s manual REV

Instruction manual MK 8

2.0 SOUND SOURCES AT PINE RIDGES INLAND CLAMSHELL OPERATION AREA

Loudness and Sharpness Calculation

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

User Manual LivingColors Bloom

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

M2 Instruction Manual

Generating the Noise Field for Ambient Noise Rejection Tests Application Note

clipping; yellow LED lights when limiting action occurs. Input Section Features

Statement Of Results For Sound Transmission Loss Tests Performed By Acoustics Laboratory At RMIT University On Behalf Of Polyphen.

FiberLink 7142 Series

Recommended Land Pattern: [mm]

i-repeater Control and monitor all your repeaters through the cloud Rackmount Wallmount

FOREST SHUTTLE S / L / M RECEIVER

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

DMP3. Users Manuual. Ver. # DMP

Quick Start Guide. Handheld Transmitter HHa-941. Digital Hybrid Wireless US Patent 7,225,135

Psychoacoustic Evaluation of Fan Noise

NV Series PA Modification for Improved Performance in FM+HD and HD Modes

PLL2710W LED LCD Monitor

By CHANNEL VISION. Flush Mount Amplifier A0350

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

USER MANUAL Full HD Widescreen LED Monitor L236VA

4 Input A/V Switcher with Automatic Input Mode and Volume Stabilizer. Model SVS-4D. User Manual

SATFINDER4 INTRODUCTION USER GUIDE AND CERTIFICATE OF GUARANTEE


MIXING BOARDS: Each input channel has an individual volume / level control. The Master volume controls the overall level of all the channels.

Model Two and Model Two Lite Signal Level Meters OPERATION MANUAL

Connecting the Elecraft Power Combo to the Kenwood TS-2000 series Transceiver

Recommended Land Pattern: [mm]

Viztrac AM200 User s Guide. Page 1 of 12

The Ideal Videoconferencing Room

RaneNote SETTING SOUND SYSTEM LEVEL CONTROLS

RXT OSA Test Module

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

Study on the Sound Quality Objective Evaluation of High Speed Train's. Door Closing Sound

Investigation into Background Noise Conditions During Music Performance

Audio Engineering Society Conference Paper Presented at the 21st Conference 2002 June 1 3 St. Petersburg, Russia

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

Trends in preference, programming and design of concert halls for symphonic music

Room Recommendations for the Cisco TelePresence System 3010

MKE 2 Gold. Instruction manual

WiPry 5x User Manual. 2.4 & 5 GHz Wireless Troubleshooting Dual Band Spectrum Analyzer

Safety Rules Parts Check Lists and Photos Cable Diagrams for Various Crane Configurations Step by Step Instructions Tips for Packaging and Storage

Voluntary Product Accessibility Template

R87B. Box Fan. Comprehensive Lineup of Single, Double, and Triple Axial Fans with Easy One-step Mounting. Ordering Information. Model Number Structure

The acoustics of the Concert Hall and the Chinese Theatre in the Beijing National Grand Theatre of China

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

Transcription:

Customer Information INSTRUCTION SHEET FOR NOISE MEASUREMENT Page 1 of 16 Carefully read all instructions and warnings before recording noise data. Call QRDC at 952-556-5205 between 9:00 am and 5:00 pm CST if further clarification is needed. Name: Address: City: State: Zip: Phone: Email: PACKAGE CONTENT Note: Inspect the package as soon as it is received. If you find any damage, notify the delivering carrier immediately and contact QRDC. Carriers have the right to refuse claims for damage if it's not promptly identified. 1. Noise Measurement Unit 3. Data Logging Form 5. Return Label 2. Instruction Sheet (this document) 4. Packaging Material 6. Cover Letter This packet contains instructions for using the QRDC Noise Monitoring Kit. When you ordered the kit, you selected specific services that are offered with the unit. For each service ordered, utilize the corresponding instruction sheet included here. Also included in this package are data logging forms. All information that you record should be on these forms. Please fill out a separate form for each noise issue that you have, and write legibly. Additional forms have been included so that you can re-write a logging form if necessary. Please see the attached example forms to get a clear understanding of what is expected of you, the customer, in order for your data to be properly analyzed. WARNING AN INHERENT DANGER EXISTS WITH HIGH SOUND LEVEL and may require hearing protective aid. If any such conditions exist that may jeopardize the safety of yourself or others or if you are unsure about proper equipment use, DO NOT USE THE EQUIPMENT and call QRDC at 952-556-5205. FAILURE TO COMPLY WITH THESE SAFETY INSTRUCTIONS OR THOSE OF OSHA AND YOUR FEDERAL, STATE OR LOCAL GOVERNMENTS, MAY RESULT IN HEARING LOSS. QRDC accepts no liability for failure to comply. DISCLAIMER: QRDC, Inc. assumes no liability, either expressed or implied, through recommended actions. All events subsequent to recommendations are the responsibility of the client, and not QRDC, Inc. The results obtained by use of QRDC s Noise Monitoring Kit are subjest to the quality of collected data. Due to uncontrolled environmental conditions, QRDC offers no guarantee that conclusive results will be achieved. QRDC will provide the customer with analysis of the collected data and corresponding conclusions and results based on the collected data and requested services. In the event that the analysis does not yield conclusive results, the customer will NOT be refunded any payments for services.

Basic Services Page 2 of 16 Loudness Measurement (Service Code 101) Loudness is a classification of the overall average noise at a specific location. With this type of measurement, you will be able to say something like, The noise level at my kitchen sink yesterday afternoon was as high as 85 dba! For each location that you would like to collect data from, please follow the below procedure: 1. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 2. Press the SPL button and record the reading on the log sheet. Note that this reading may 3. Record the date, time, and location on the log sheet. 4. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF.

Basic Services Page 3 of 16 Noise Source Characterization (Service Code 102) With this type of service, you may collect specific data about the noise that is propagating to a certain location. For example, you could find out details about the source of annoying buzzing you hear while the air conditioning is running. Knowing the roots or the source of noise may aid in diagnosing the problem, or identifying how you can shield yourself from the noise. For this service, follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. Repeat steps 5-6 two times for three measurements in total. 8. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF. 9. Shut down the sound recorder (left) by holding down the PWR button until the screen turns off.

Basic Services Page 4 of 16 Noise Source Identification (Service Code 103) Similar to the Noise Source Characterization service, this service goes one step further and helps you to better identify the cause of excess noise. For instance, you may hear a loud noise coming from your basement, but you just can t identify what the source could be. By following the procedures and collecting the data listed in these instructions, it may be possible to identify the source. For this service, follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know where the source of the sound is, aim the recording device (metal mesh) at the source. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, location, and measurement direction on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. Rotate the data collector 90º clockwise. 8. Repeat steps 4-7 three (3) times for a total of four (4) measurements at the same location (but at different rotational positions). 9. Identify the location at which you hear the second loudest noise (second noisiest room). If you know where the source of the sound is, aim the recording device (metal mesh) at the source. 10. Repeat steps 3-8 for a total of four (4) measurements at this second location. 11. Identify the location at which you hear the third loudest noise (third noisiest room). If you know where the source of the sound is, aim the recording device (metal mesh) at the source. 12. Repeat steps 3-8 for a total of four (4) measurements at this third location. 13. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF. 14. Shut down the sound recorder (left) by holding down the PWR button until the screen turns off.

Basic Services Page 5 of 16 Noise Source Location (Service Code 104) Consider that you have an offensive noise no matter where you seem to go within your home, building, or outdoor environment. If you have a difficult time identifying where it is coming from, use the Noise Source Location procedure. After we receive and analyze the collected data, we may be able to help you determine where that problem sound comes from. For multiple locations around the area that you can hear the noise, follow the instructions below: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (the place where you hear the loudest noise). Place the data collector on a flat and stable surface. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, location, and measurement direction on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. Rotate the data collector 90º clockwise. 8. Repeat steps 4-7 three (3) times for a total of four (4) measurements at the same location (but at different rotational positions). 9. Choose a few (2-4) other locations (i.e. different rooms or areas) at significant distances away from one another. Repeat steps 2-8 for each location. 10. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF. 11. Shut down the sound recorder (left)by holding down the PWR button until the screen turns off.

Basic Services Page 6 of 16 Potential Solutions (Service Code 105) With data collected using the Noise Source Location service and procedure, you may be looking for help identifying possible solutions that will lower the noises that you are hearing. QRDC offers recommendations to reduce noise based on three techniques: treating the source; treating the path; and treating the receiver. Utilize our years of experience to get some suggestions on what you can do.

Basic Services Page 7 of 16 Ordinance Violation (Service Code 106) Are you utilizing the noise measurement kit because you believe the noise level in your residence exceeds the local ordinance? If so, you may want some assistance in identifying whether the data you collected indicates a violation. We have the capabilities of looking up the ordinances where you live, and identifying whether data you recorded indicates a violation is occurring or not. This service must be accommodated with one or more of the other basic services, such as loudness and noise characterization.

Basic Services Page 8 of 16 Follow-Up Recommendations (Service Code 107) Data may be used to confirm that you can justify investing more resources into investigating your acoustic environment, possibly making a case that something needs to change. We can provide recommendations for further investigation, based on our analyses. This must be accommodated by at least one of the basic services, such as loudness and noise characterization.

Advanced Services Page 9 of 16 Sound Pressure Level (SPL) (Service Code 200) Sound Pressure: The Sound Pressure is the force (N) of sound on a surface area (m2) perpendicular to the direction of the sound. The SI-units for the Sound Pressure are N/m2 or Pa. Sound is usually measured with microphones responding proportionally to the sound pressure - p. The power in a sound wave goes as the square of the pressure. The Sound Pressure Level: The lowest sound pressure possible to hear is approximately 2x10-5 Pa (20 micro Pascal, 0.02 mpa), 2 ten billionths of an atmosphere. It therefore convenient to express the sound pressure as a logarithmic decibel scale related to this lowest human hearable sound 2x10-5 Pa, 0 db. The Sound Pressure Level can be expressed as: p L p 10log 2 p where: L p = sound pressure level (db) p = sound pressure (Pa) p ref = 2x10-5 - reference sound pressure (Pa) 2 ref 20log p p ref If the pressure is doubled, the sound pressure level is increased by 6 db (=20 log (2)). For each location that you would like to collect data, please follow the below procedure: 1. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 2. Press the SPL button and record the reading on the log sheet. Note that this reading may 3. Record the date, time, and location on the log sheet. 4. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF.

Advanced Services Page 10 of 16 Octave and Fractional Octave SPL (Service Code 201) Scales of octave bands and one-third octave bands have been developed for engineering applications. Each band covers a specific range of frequencies and excludes all others. The word "octave" is borrowed from musical nomenclature where it refers to a span of eight notes, i.e. do to do. The ratio of the frequency of the highest note to the lowest note in an octave is 2:1. If f n is the lower cutoff frequency and f n+1 is the upper cutoff frequency, then the ratio of band limits is given by: where k = 1 for full octave bands and k = 1/3 for one-third octave bands. An octave has a center frequency that is 2 times the lower cutoff frequency and has an upper cutoff frequency that is twice the lower cutoff frequency. Therefore, where f 1 = lower cutoff frequency f 2 = upper cutoff frequency f 0 = center frequency bw = band width For this service, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may vary somewhat just record what you observe to be an average value. Note also that there is a MAX feature on the unit, which (if enabled) you should disable by pressing the button 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. Repeat steps 4-6 two times for three measurements in total 8. Shut down the sound level display by holding down the SPL button until the screen reads OFF. 9. Shut down the sound recorder (left) by holding down the PWR button until the screen turns off.

Advanced Services Page 11 of 16 Narrowband Spectrum (Service Code 202) The term narrowband is used to describe a measurement where a frequency analysis of the sound is made and thereafter only the frequency bands containing the characteristic frequencies are used in the evaluation. For acoustic measurements, sound pressure, sound intensity, and sound power levels can all be deduced for narrowband spectrums. Narrowband analysis may be necessary in situations where the environment has numerous noise sources, and only information about specific frequencies are desired. For each location that you would like to collect data, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. Repeat steps 4-6 two times for three measurements in total 8. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF. 9. Shut down the sound recorder (left) by holding down the PWR button until the screen turns off.

Advanced Services Page 12 of 16 L eq (L ave ) (Service Code 203) Equivalent Sound Level quantifies the noise environment as a single value of sound level for any desired duration. This descriptor correlates well with the effects of noise on people. L eq is also sometimes known as Average Sound Level (L AT ). Equivalent Sound Level can be expressed as: 1 L eq 10log T where L eq = equivalent sound level (db) T = time period (s) p A = sound pressure (Pa,N/m 2 ) p ref = reference sound pressure (20x10-6 Pa, N/m 2 ) For each location that you would like to collect data, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges), allow data collector to record for minutes hours. 7. When the above time has elapsed, press the STOP button. 8. Rotate the data collector 90º clockwise. 9. Repeat steps 4-8 three (3) times for a total of four (4) measurements. 10. Shut down the sound level display (right) by holding down the SPL button until the screen reads OFF. 11. Shut down the sound recorder (left) by holding down the PWR button until the screen turns off. p p 2 A ref dt 2

Advanced Services Page 13 of 16 L 10, L 50, L 90, L 95 (Service Code 204) L n, where n may be anything from 1 to 99, is that noise level exceeded for n% of the measurement time. An example of how L n values look in a graphical format: L 10 is the noise level exceeded for 10% of the time of the measurement duration. This is often used to give an indication of the upper limit of fluctuating noise, such as that from road traffic. L 50 is the noise level exceeded for 50% of the measurement duration. It is the middle point and has been incorporated in some American Community Noise Assessments. L 90 is taken to be the ambient or background noise level as used. For each location that you would like to collect data, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. 4. Record the date, time, and location on the log sheet. 5. Press the REC button and write down the name of the current record file on the log sheet. 6. Press the REC button once more, allow data collector to record for minutes hours. 7. When the above time has elapsed, press the STOP button. 8. Rotate the data collector 90º clockwise. 9. Repeat steps 4-8 three (3) times for a total of four (4) measurements. 10. To shut down the sound level display (right), hold down the SPL button until the screen reads OFF. To shut down the sound recorder (left), hold down the PWR button until the screen turns off.

Advanced Services Page 14 of 16 L dn, L den (Service Code 205) Day-Night Sound Level (L dn ) is the A-weighted equivalent sound level for a 24 hour period with an additional 10 db imposed on the equivalent sound levels for night time hours of 10 p.m. to 7 a.m. Day-Night Sound Level can be expressed as: L dn 1510 10log 9 10 24 Ld / 10 Ln10 /10 where L dn = day-night sound level (db) L d = daytime equivalent sound level (db) L n = nighttime equivalent sound level (db) For each location that you would like to collect data, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for 24 hours, and then press the STOP button. 7. When the above time has elapsed, press the STOP button. 8. To shut down the sound level display (right), hold down the SPL button until the screen reads OFF. To shut down the sound recorder (left), hold down the PWR button until the screen turns off.

Advanced Services Page 15 of 16 NC, NR (Service Code 206) Noise in buildings is more stable (over time) than outside community noise. The Noise Rating (NR) curves are developed by the International Organization for Standardization (ISO), and specify the maximum acceptable noise level for indoor environments. In the United States, a similar rating, the Noise Criterion (NC), is used. For both NC and NR, values are determined from the measurements of the octave-band sound levels in an occupied room when the mechanical systems are on. The measured values are then compared to standard NC (or NR) curves. For each location that you would like to collect data, please follow the below procedure: 1. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 2. Identify the location of interest (likely the place where you hear the loudest noise). Place the data collector on a flat and stable surface. If you know what the source of the sound is, aim the recording device (metal mesh) at the source, about 1 meter away. If you are in a room and don t know where or which direction the noise comes from, place the data collector at the center of the room. 3. Press the SPL button and record the reading on the log sheet. Note that this reading may 4. Record the date, time, and location on the log sheet. 5. Press the REC button once (you will see the button flash on the edges). The unit is in standby right now. Write down the name of the current record file on the log sheet (e.g. DR000005.wav). You can read information from the LCD display. 6. Press the REC button once more (you will see the button glow solid red on the edges). The unit is now recording. Allow the data collector to record for about one (1) minute, and then press the STOP button. 7. To shut down the sound level display (right), hold down the SPL button until the screen reads OFF. To shut down the sound recorder (left), hold down the PWR button until the screen turns off.

Advanced Services Page 16 of 16 RT60 (Service Code 207) The Sound Reverberation Time (RT60) of a room is the time it takes for sound to decay by 60 db once the source of sound has stopped. Reverberation time is inversely related to sound absorption and is a way to measure the amount of absorption in a room. Long RT60 times tend to make it more difficult to understand speech in a room, but may be pleasing for some forms of music. Additionally, in most rooms RT60 times will be longer at the lower frequencies. Because RT60 is a measurement of the sound as it decays, it is essential to have sufficient signal to noise. Especially in the 120Hz Octave band, it is common to have excessive levels of noise from the HVAC system. Accordingly, HVAC should be turned off whenever feasible while making the measurements. The quieter it is in the room, the easier it will be to measure the decay, and to get good data. For each location that you would like to collect data, please follow the below procedure: 1. Locate and inflate the three (3) balloons provided in the noise measurement kit. 2. Locate the pin provided in the noise measurement kit. 3. Locate the ear plugs provided in the noise measurement kit. 4. Insert the ear plugs as directed on the packaging. 5. Turn on the recording device by pressing and holding the PWR button on the side of the data collector for 3-5 seconds. The display should light up orange. 6. Place the data collector at the center of the room, on a flat, stable surface. 7. Press the SPL button and record the reading on the log sheet. Note that this reading may 8. Record the date, time, and location on the log sheet. 9. Press the REC button once and write the name of the current record file on the log sheet. 10. Press the REC button once more and allow the data collector to record for about one (1) minute, and then press the STOP button. 11. Record the date, time, and location on the log sheet. 12. Press the REC button twice again, and write down the record file name on the log sheet. 13. Locate yourself in the room to be tested as far as possible from the recording device. 14. Facing the recording device, hold the balloon at arm s length in front of you, and pop the balloon with the pin. (Feel free to close your eyes.) 15. Continue to record for one (1) minute after pop. 16. Press the STOP button. 17. Repeat steps 10-16 two (2) times for a total of three (3) measurements. 18. To shut down the sound level display (right), hold down the SPL button until the screen reads OFF. To shut down the sound recorder (left), hold down the PWR button until the screen turns off. 19. Dispose of popped balloons and pin.