WARNING This manual is deemed correct on going to press. The information contained has been scrupulously checked. However AUTINOR declines al1 responsibility for error or omission. Should you notice any discrepancy or unclear description, or if you have any suggestions, we would appreciate your written comments (by mail, fax or Email) to: Société AUTINOR - Service Documentation Z.A. Les Marlières 59710 AVELIN S [33] 03-20-62-56-00 3 [33] 03-20-62-56-41 IXI autinor@autinor.com This manual is the property of AUTINOR, from whom it may be bought (at the above address). It may however by freely copied in order to communicate information to those who might need it. We can only authorise a complete copy, without neither addition nor removal of information Where quotations are taken, the following at least must be noted: - The Company name of AUTINOR, - The number and date of the original edition. O Copyright 2000 AUTINORAll rights reserved.
C O N T E N T S COMPOSITION OF THE «INCREMENTAL ENCODER» KIT... 6 Choice and imperative of encoder... 6 Preliminaly checks... 6 INSTALLATION OF INCREMENTAL ENCODER... 7 WlRING OF INCREMENTAL ENCODER... 8 Viewing the incremental encoder impulses... 8 MECHANICAL CHARACTERISTICS... 9 Electrical characteristics... 9
Documentation departmen t Installation and wiring of incremen ta1 encoder Page 6 COMPOSITION OF THE INCREMENTAL ENCODER» KIT lncremental encoder Encoder fixing screws Installation and wiring Manual Flexible coupling Tapping screw CHOICE AND IMPERATIVE OF ENCODER Figure 1 1024 pts for a 4 or 6 poles motor or a gearless motor, PRELIMINARY CHECKS The incremental encoder to be assembled at the end of the traction motor shaft. The "incremental encoder kit", delivered in a plastic bag containing the following parts (Figure 1): An installation and wiring manual, An HENGSTLERB incremental encoder, 3 encoder fixing screws, M3 X 10, The incremental encoder fixing plate, The special tapping screw, allowing 3 different diameters, (Ml6 X 8 and Ml4 X 8, thread of 2 and Ml2 X 8, thread of 1,75) to be screwed into the thread recessed hole at the end of the motor shaft, The flexible coupling device training screw 1 encoder WARNING!!! Take account of the variety of gear and chassis, the "encoder kit" does not contain the linking piece between encoder fixing plate and the gear chassis! It is therefore up to you to make the adaptation specific to your requirements.
Documentation department Installation and wiring of incremental encoder Page 7 INSTALLATION OF INCREMENTAL ENCODER The present documentation presumes that the incremental encoder is fixed at the end of the traction motor shaft, from the wheel side to allow manual operation; this ought always be possible with new installations which must respect paragraph 6.3.2.1 of the standard EN 81-1 : 6.3 Construction and equipment of machine rooms 6.3.2 Dimensions 6.3.2.1 The dimensions of machine rooms shall be sufficient to permit easy and safe working on equipment, especially the electrical equipment. In particular there shall be provided at least a clear height of 2 m at working areas, and: a) a clear horizontal area in front of the control panels and the cabinets. This area is defined as follows: 1) depth, measured from the external surface of the enclosures, at least 0,70 m ; 2) width, the greater of the following values : 0,50 m or the full width of the cabinet or panel ; b) a clear horizontal area of at least 0,50 m x 0,60 m for maintenance and inspection of moving parts at points where this is necessary and, if need be, manual emergency operation (12.5.1). If the installation configuration does not allow you to fix the encoder at the end of the motor shaft (especially when renovating the installation) you will have to study the coupling required (cardan system, angular reflexion or other). BEFORE BEGlNNlNG THE INCREMENTAL ENCODER ASSEMBLY, PLEASE INSURE THAT ONE OF THE THREE DIAMETER AND ALSO THAT THE THREAD OF THE SPECIAL TAPPING SCREW ARE CORRESPONDING TO THE THREAD OF THE RECESSED HOLE AT THE END OF THE MOTOR SHAFT!
Documentation department Installation and wiring of incremental encoder Page 8 WlRlNG OF INCREMENTAL ENCODER I The wiring of CA1 and CBI is depending of the motor rotate movement. In the UPWARDS direction the value displayed at address 116 INCREASES while in the DOWNWARDS direction the value displayed DECREASES Turn the inertia wheel to some millimeters for make this operation or used the machineroom inspection. I 1 Red White 1 Blalck 1 Green INCREMENTAL ENCODER 1 HENGSTLER 1 +24 RED OV BLACK CA1 WHITE CBI GREEN l CUT THE WlRES WHlCH ARE NOT USED. SCREENING CABLE DO NOT CONNECT. WARNING! -t The encoder cable mustn't pass near the high voltage cable (E.g: Motor cable). lncremental 1 1 VIEWING THE INCREMENTAL ENCODER IMPULSES Reset the display to address 000 by pressing the CLEAR buttons simultaneously 1000 100 10 1 MODIF. CLEAR VALID. 0-@-@-O Display address 11 6 using buttons 100,lO and 1 11 1 116 Codeur 0635-1000 100 10 1 MODIF. CLEAR VALID. 0-- 1 - The value displayed at address 116 increases when the rotor turns in the upwards direction 1 The value displayed at address 116 decreases when the rotor turns in the 1-1 1 1 1 downwards direction 1000 100 10 1 MODIF. CLEAR VALID. 0-0-0-0 1000 100 10 1 MODIF. CLEAR VALID. 0-0-0-0
Documentation departmen t Installation and wiring of incremen ta1 encoder Page 9 The incremental encoder has the following mechanical constraints: HENGSTLER~ Maximum rotation speed Angular acceleration Rotation torque Absolute maximum axial load Absolute maximum radial load Use temperature Storage temperature Protection number Shock rating Vibration rating Length of mechanical life Relative humidity (Avoid the condensation) Weight Encoder cable Cable length Cable curve 10 000 tlmn 5.105 radls2 5 0,5 N-cm 140 N with axis of 12 mm 107 N with axis of 10 mm 60 N with axis of 6 mm 180 N with axis of 12 mm 160 N with axis of 10 mm 110 N with axis of 6 mm -1 0 C to +70 C with PVC cable -25 C to +85"C with PVC cable IP67 with PVC cable 100 g during 3 ms in option 200 g log between 10 Hzand2 khzinoption 30g 1.1 0'' turns at 35 % of the absolute max load 1.IO9 turns at 75 % of the absolute max load 1.IO8 turns at 100 Oh of the absolute max load 75 % 360 g around 6 conductors screened cable IOm Permanent Rt IOOmm, occasional R t 40mm Tableau 1 Mechanical characteristics of the incremental encoder Power supply 5VCC~10%or10to30VCC Consumption without charge 40 ma to 5 VCC 30 ma to 24 VCC Symmetric outputs protected against short circuits (push pull) Used outputs A and B Tableau 2 Electrical characteristics of the incremental encoder