Design of a Gaussian Filter for the J-PARC E-14 Collaboration

Similar documents
THE TIMING COUNTER OF THE MEG EXPERIMENT: DESIGN AND COMMISSIONING (OR HOW TO BUILD YOUR OWN HIGH TIMING RESOLUTION DETECTOR )

A flexible FPGA based QDC and TDC for the HADES and the CBM calorimeters TWEPP 2016, Karlsruhe HADES CBM

PoS(PhotoDet 2012)018

Silicon PhotoMultiplier Kits

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Time Resolution Improvement of an Electromagnetic Calorimeter Based on Lead Tungstate Crystals

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

Updates on the Central TOF System for the CLAS12 detector

MCP Signal Extraction and Timing Studies. Kurtis Nishimura University of Hawaii LAPPD Collaboration Meeting June 11, 2010

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

Production and Development status of MPPC

LabView Exercises: Part II

Pixelated Positron Timing Counter with SiPM-readout Scintillator for MEG II experiment

A FOUR GAIN READOUT INTEGRATED CIRCUIT : FRIC 96_1

Performance of the MCP-PMT for the Belle II TOP counter

Sensors for precision timing HEP

Commissioning and Initial Performance of the Belle II itop PID Subdetector

Beam test of the QMB6 calibration board and HBU0 prototype

A fast and precise COME & KISS* QDC and TDC for diamond detectors and further applications

PMT Gain & Resolution Measurements in High Magnetic Fields

An extreme high resolution Timing Counter for the MEG experiment Upgrade

Realization and Test of the Engineering Prototype of the CALICE Tile Hadron Calorimeter

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Single-sided CZT strip detectors

Photodetector Testing Facilities at Nevis Labs & Barnard College. Reshmi Mukherjee Barnard College, Columbia University

Large photocathode 20-inch PMT testing methods for the JUNO experiment

78 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY Factors Influencing Timing Resolution in a Commercial LSO PET Camera

SPE analysis of high efficiency PMTs for the DEAP-3600 dark matter detector

arxiv: v1 [physics.ins-det] 1 Nov 2015

Tests of Timing Properties of Silicon Photomultipliers

TORCH a large-area detector for high resolution time-of-flight

Study of Timing and Efficiency Properties of Multi-Anode Photomultipliers

Table. J. Va vra,

Citation X-Ray Spectrometry (2011), 40(6): 4. Nakaye, Y. and Kawai, J. (2011), ED

PulseCounter Neutron & Gamma Spectrometry Software Manual

Using Geant4 in the BaBar Simulation. CHEP03 25 March 2003 Dennis Wright (SLAC) on behalf of the BaBar computing group

Beam Test Results and ORCA validation for CMS EMU CSC front-end electronics N. Terentiev

Hamamatsu R1584 PMT Modifications

EL302 DIGITAL INTEGRATED CIRCUITS LAB #3 CMOS EDGE TRIGGERED D FLIP-FLOP. Due İLKER KALYONCU, 10043

Focusing DIRC R&D. J. Va vra, SLAC

CAEN Tools for Discovery

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

ATEAM at the Brookhaven National Laboratory is currently

Software Tools for the Analysis of the Photocathode Response of Photomultiplier Vacuum Tubes

An extreme high resolution Timing Counter for the MEG Upgrade

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

arxiv:hep-ex/ v1 27 Nov 2003

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

DATA ACQUISITION FOR MONOLITHIC SCINTILLATION DETECTORS IN PET APPLICATIONS

BUNCH-BY-BUNCH DIAGNOSTICS AT THE APS USING TIME- CORRELATED SINGLE-PHOTON COUNTING TECHNIQUES*

Comparison Between DRS4 Chip-Based Boards and ADCs for a Flexible PET Electronics

3 EXPERIMENTAL INVESTIGATIONS Caroline Robson. 3.1 Aims and Objectives. 3.2 Experimental Method Set Up of the Test Stand

Investigation of time-of-flight PET detectors with depth encoding

Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results

Institute of Electrical and Electronics Engineers (IEEE)

The Time-of-Flight Detector for the ALICE experiment

Tests of AGATA preamplifiers and hints to improve their performance

The TORCH PMT: A close packing, multi-anode, long life MCP-PMT for Cherenkov applications

Frontend Electronics for high-precision single photo-electron timing

Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode. R.Bellazzini - INFN Pisa. Vienna February

Diamond detectors in the CMS BCM1F

A High-Resolution Flash Time-to-Digital Converter Taking Into Account Process Variability. Nikolaos Minas David Kinniment Keith Heron Gordon Russell

Sample Analysis Design. Element2 - Basic Software Concepts (cont d)

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Lawrence Berkeley National Laboratory

CESR BPM System Calibration

Electronics Status and Upgrade Opportunities for Flash ADC and 12GeV Trigger Hardware

Eric Oberla Univ. of Chicago 15-Dec 2015

Update on DAQ for 12 GeV Hall C

PICOSECOND TIMING USING FAST ANALOG SAMPLING

Novel Data Acquisition System for Silicon Tracking Detectors

Update on DAQ for 12 GeV Hall C. Brad Sawatzky

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

High ResolutionCross Strip Anodes for Photon Counting detectors

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

TitleLarge strip RPCs for the LEPS2 TOF. Author(s) Chu, M.-L.; Chang, W.-C.; Chen, J.- Equipment (2014), 766:

The hybrid photon detectors for the LHCb-RICH counters

A prototype of fine granularity lead-scintillating fiber calorimeter with imaging read-out

Application of HDMI Cables as an MRI Compatible Single Cable Solution for Readout and Power Supply of SiPM Based PET Detectors

Imaging TOP (itop), Cosmic Ray Test Stand & PID Readout Update

Front End Electronics

DAQ Systems in Hall A

Spatial Response of Photon Detectors used in the Focusing DIRC prototype

Imaging diagnostico in Sanità Stato attuale e prospettive

Neutron Irradiation Tests of an S-LINK-over-G-link System

First LHC Beams in ATLAS. Peter Krieger University of Toronto On behalf of the ATLAS Collaboration

Front End Electronics

Chapter 6. Normal Distributions

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Thick Pixelated CZT Detectors With Isolated Steering Grids

Adaptive Digital Filter for High-Rate High-Resolution Gamma Spectrometry

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

3-D position sensitive CdZnTe gamma-ray spectrometers

Design of High Speed Phase Frequency Detector in 0.18 μm CMOS Process for PLL Application

REAL-TIME DISPLAY OF RADIATION FIELD INTENSITY DISTRIBUTION. P. A. Berardo J. A. Willis

INTEGRATED CIRCUITS. AN219 A metastability primer Nov 15

The trigger for the New Electromagnetic Calorimeter NewCal

SLAC National Accelerator Laboratory, CA, USA. University of Hawaii, USA. CEA/Irfu Saclay, France *

ATLAS Pixel Subsystem and Simulation

Transcription:

Design of a Gaussian Filter for the J-PARC E-14 Collaboration Kelsey Morgan with M. Bogdan, J. Ma, and Y. Wah August 16, 2007 1 Abstract This paper describes the design, simulation, and pulse fitting result for a Gaussian filter built for the J-PARC E-14 collaboration. The filter is a 10-pole shaper designed to produce a Gaussian-shaped output pulse in the time domain. The performance of the filter was studied for various levels of energy deposited, as well as different rates of asynchronous sampling. At a sampling rate of 125MHz, timing resolution is better than 0.5ns when the energy deposited is greater than 10MeV. For a pulse with an energy of 200MeV,the timing resolution is approximately 110ps. 2 Introduction In the experiment, photons from KL 0 decays are detected by an array of Cesium Iodide (CsI) scintillators, each connected to a photomultiplier tube (PMT). Prior to the development of the 10-pole Gaussian filter, the experiment used a 7-pole Bessel filter originally designed for use in the ATLAS tile calorimeter 1. The Bessel filter makes the input pulse from the CsI/PMT detector into a quasi-gaussian output pulse with a FWHM of approximately 45ns 2. In order to improve upon the timing resolution of the Bessel filter, the 10-pole Gaussian filter was designed to produce a more symmetric, and therefore more gaussian-shaped output pulse. The 10-pole filter consists of 5 inductors, 5 capacitors, and 2 resistors. The values for each component were determined using the Accusim electronics simulation software. The filtered output pulse is sampled at 125MHz using a technique called flash ADC sampling. Typically, timing is measured using TDC sampling and total energy is measured using ADC. However, because the filtered output is gaussian shaped, we can fit the output using the chisquare method, then use the fitted peak as the time of the hit and the height of the peak to determine the total charge. Therefore, only ADC sampling is necessary. In this paper, we examine the uncertainty in the timing resolution when the pulse timing is measured using this new method. The fitting of the pulse depends on the starting point from which the pulse is sampled, as well as the frequency of sampling. The starting point for sampling is determined by a global trigger, which is random relative to the arrival of the pulse in the CsI scintillator. This is referred to as asynchronous sampling. This paper also examines the effect of 1 K. Anderson, et al., Nucl. Instr. and Meth. A 551(2005) 469. 2 J. Ma, et al., Bessel Filter Simulation. (2007)1. 1

asynchronous sampling and different sampling frequencies on the time resolution of the output pulse. 3 Design of the Gaussian Filter The input pulse from the PMT can be approximated by a pulse with a reise time of 5ns and a fall comprised of two exponential functions as follows: The input pulse is shown below in Figure 1. 18.4e t\23.6ns + e t\63.5ns Figure 1: Input Pulse The input pulse was run through the 10-pole Gaussian filter using the AccuSim software. Starting with values derived from Zverov s Handbook of Filter Synthesis, the components were modified individually to minimize the difference between the left and right side FWHM of the output pulse, while minimizing any ringing. This created a symmetric output pulse that was much closer to a true gaussian shape than the output of the 7-pole Bessel filter. The resulting schematic for the 10-pole Gaussian filter is shown in Figure 2 below. The input and output obtained from the AccuSim software is shown in Figure 3. Figure 2: 10-pole Gaussian Filter 2

Figure 3: Input pulse (top), 7-pole output (center), and 10-pole output (bottom) 4 Timing Resolution for 125MHz (8ns) Sampling To determine the arrival time of the pulse, we measure the position of the mean, or peak, of the output pulse. To test the accuracy of this measurement, we first smear each sampled output point to simulate the effect of photoelectron statistics at the PMT. We also change the starting point for sampling. Figure 4 shows a distribution of measured peak arrival times for 1600 simulated pulses. All of the pulses arrive at the same time, however, the photoelectron smearing and asynchronous sampling cause variation in the measured peak obtained from fitting. On the left, we see the distribution of measured peak timings for a pulse with a total energy of 200MeV. The resolution of the measurement is approximately σ = 110ps. On the right is a distribution for a pulse with total energy equal to 10MeV. The timing resolution for the lower energy pulse is about σ = 500ps. We find that as the energy of the pulse decreases, the timing resolution worsens, especially below 5MeV. Figure 5 shows the trend in time resolution for energies less than 10MeV. 5 Comparison With 7-Pole Bessel Filter The timing resolution of the new filter was compared with that of the 7-pole Bessel filter to determine whether improving the gaussian shape improved the resolution. At 200MeV, the resolution of the 10-pole filter was 110ps versus 250ps for the 7-pole filter 3, meaning 3 J. Ma, et al., Bessel Filter Simulation. (2007)2. 3

Figure 4: Timing Resolution: 200MeV pulse (left) and 10MeV pulse (right) 1.8 lowmev 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Energy (MeV) Figure 5: Timing Resolution, Low Energy Pulses 4

Figure 6: Time Resolution Histogram: 10-pole filter (left) and 7-pole filter (right) that at high energies, the new filter cuts the uncertainty in time measurement in half. For low energies, the performance of the two filters is comparable, with the 10-pole filter having slightly better resolution. To determine why the 10-pole filter performs so much better than the 7-pole filter at high energies, we examined a two-dimensional histogram of the resolution. The historgram shows the measured peak position on the y-axis and the starting point for asynchronous sampling on the x-axis. Two-dimensional histrograms for each filter are shown in Figure 6. While the histrogram for the 7-pole filter shows a downward trend in the measured peak position as the sampling points change, the measurements for the 10-pole filter remain consistent. This means that improving the gaussian shape of the pulse eliminated statistical walk due to asynchronous sampling, which caused much of the improvement in the timing resolution. 6 Effects of Asynchronous Sampling & Sampling Rate As discussed in Section 5, the histogram of measured peak times for variations of asynchronous sampling showed no walk at 200MeV. Similar plots made for low energy pulses (energies less than 10MeV) show similarly level distribution, leading us to conclude that the technique of asynchronous sampling has little to no effect on the timing resolution of the 10-pole filter. Next we wanted to examine the effect of varying the sampling frequency on the timing resolution. Simulation was repeated for reates ranging from 83.33 MHz (12ns) to 333.33MHz (3ns). As expected, the accuracy of measurement increases with the sampling frequency. Timing resolutions at 200MeV ranged from approximately 130ps at 83.33MHz to 65ps at 333.33MHz. Unfortunately, as the rate of sampling increases, so does the cost of the experiment. Therefore, it is likely that the experiment will be conducted using the current 125MHz sampling rate. A plot of the timing resolution versus the rate of asynchronous sampling is shown in Figure 7. 5

7 Conclusions Figure 7: Timing Resolution for Different Rates of Sampling Simulation for the 10-pole Gaussian filter shows that improving the gaussian fit of the output pulse significantly improves the timing resolution of the filter. We found that at high energies, the timing resolution of the 10-pole filter was double that of the old 7-pole filter originally intended for use with the experiment. At 200MeV, the 10-pole filter has a resolution of 110ps, whereas the 7-pole filter had a resolution of 250ps. Wewereabletotest the performance of the filter at low energy, and also confirm that the use of asynchronous sampling does not negatively effect the filter s performance. Finally, we confirmed that the performance of the filter can be improved even further by increasing the rate of asynchronous sampling. These simulations show that time measurement for the experiment can be performed using only ADC, eliminating the need for TDC measurement. 6