SH2RE16A4. Output relay module. Benefits. Description

Similar documents
15 Series - Dimmer

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

02/11/2015

Fibre Optic Modem ODW-622

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Fibre Optic Modem ODW-611

LONWORKS Fibre Optic Converter

ODW-621. RS-232 Point-to-point applications

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Rack mounted telephone- and leased line modem for industrial applications

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Router

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

10 SERIES. Light dependent relays A

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Gamma instabus. Technical product information

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Assembly. Front view. LEDs. Parametrization interface. Power Bus

I/A Series Hardware Fiber Optic LAN Converter

LW10-T600. P10 Led Wall Display

Modular pulse operated latching relay 16 A

Datasheet - SRB301LC 24VAC/DC

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

IP Roombox. Hotel Room Management

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Time-Lag Relays. User s Handbook (General Model)

LED Driver Compact fixed output

Indoor Linear 80W Driver SI-C215280N2KR

KAA-4R4V. KNX LED actuator / dimmer

Ordering details. Approval. Classification

Digital output modules


PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

DIN-1DIMU4. DIN Rail Universal Dimmer, 1 feed, 4 channels

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

LED Driver Linear / area fixed output

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Datasheet - SRB-E-201ST

DLP200M 2 Relay Module for Heating and Cooling Plants

PRODUCT SPECIFICATION Date: VESTEL

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

LED control gear Compact fixed output

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

NI PXI/PXIe-2543 Specifications

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Emergency lighting units EM powerled

Displacement Measuring System for Cylinder Series OSP-P

DLP600M 6+1 Relay Module for Heating and Cooling Plants

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

LED Driver Compact dimming

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

User s Manual. LG Industrial Systems G3F AT4A. LG Programmable Logic Controller

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Actuators IC 20, IC 40

Material: Weight: IP Rating: Cable: Connector:

HPX-T Series. Auto-tuning Fiber Optic Photoelectric Control. Specifications CLICK FEATURES AMPLIFIER UNIT ORDER GUIDE. No.

LED MODULES READYLINE DL

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

PRODUCT SPECIFICATION Date: VESTEL

MAP110 AC-DC Series Data Sheet

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Model Number Structure

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

Cylindrical Photoelectric Sensor CY-100 SERIES

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

B65 LED Emergency lighting units with LEDs

Standard RS232 RS ma

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

ALLEN BRADLEY TIMING RELAY

Process transmitter RMA422

Model FS-4608R. Features. Overview

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Type SCH94FO. Type SCH94FO. Description

Location. Electrical. Loads. 2-wire mains-rated, 0.5 mm² to 1.5 mm² Max. length: 300 m (with 1.5 mm² cable). Example: Belden 8471.

FOM-9010, FOM-9011 and FOM-9012

Multifunction Digital Timer

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

Generator protection relay

263 Series LED Bargraph Indicator and Controllers

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

Catalogue Ignitors and power switches for HID

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

3500/42E Vibration Monitor

Level Measurement silometer FMC 420, FMC 423

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Series CT7N Bimetallic Overload Relays

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Transcription:

Output relay module Benefits Integrated system. Dupline is the brand name for Carlo Gavazzi s 2-wire bus system. Cost reduction. The use of a bus system is a proven way to reduce installation costs - especially when the distance between I/O points is extensive. Fast and easy installation. Completely free topology, no special cable required, no screen or twist. It can go for 2 km and even further with repeaters. High noise immunity. Can run next to power cables. Scalability. The system can be progressively integrated with new modules according to the application needs. Modularity. The system is composed by many modules, powered by the bus, so that each installation can be precisely and easily sized. Description This is a four-relay output module for DIN mounting. When an activation command is received from the Dupline bus, the output turns ON and remains ON until the OFF command is received. Thanks to the internal bus, the modules can be connected one next to the other without the need for wiring the Dupline bus. Applications Smart Dupline is a bus system that offers unique solutions for a wide range of applications in home and building automation, industrial automation, water distribution, energy management, railway systems and many other areas. Main features 4 separate output channels Relay load 16 A Module load: 64 A 2-DIN housing LED indication for power supply, Dupline bus,output1, output2, output3, output4 Connection to other cabinet modules via local bus 1

Structure A 5 B C OUT D ON UWP-DIM Element Component Function A Connection Connection by terminal 8-screw type to relay outputs B Push button To locally control the outputs C Local bus Supplied by the Dupline bus on the local bus D Information LED Indicating the following status: Green LED: Power supply Yellow LED: Dupline bus Red LED's: Outputs 2

Features General Material Dimensions Weight Protection grade Dielectric strength Terminal Noryl 2-DIN module 150 g Front: IP50; Screw terminal: IP20 Dupline to output 4kV AC for 1 min.; 6 kv impulse 1.2/50µs 8 screw-type; Section: 1.5 mm 2 maximum; Torque: 0.4-0.8 Nm 35 44,0 14,5 5 90,0 45,0 Environmental Operating temperature Storage temperature Humidity (non-condensing) -20 to +50 C (-4 to 122 F) -50 to +85 C (-58 to 185 F) 20 to 80% RH 3

Compatibility and conformity Electromagnetic compatibility (EMC) - immunity Electromagnetic compatibility (EMC) - emissions EN 61000-6-2 Electrostatic discharge: EN 61000-4-2 Radiated radiofrequency: EN 61000-4-3 Burst immunity: EN 61000-4-4 Surge: EN 61000-4-5 Conducted radio frequency: EN 61000-4-6 Power frequency magnetic fields: EN 61000-4-8 Voltage dips, variations, interruptions: EN 61000-4-11 EN 61000-6-3 Conducted and radiated emissions: CISPR 22 (EN55022), cl. B Conducted emissions: CISPR 16-2-1 EN55016-2-1) Radiated emissions: CISPR 16-2-3 (EN55016-2-3) Approvals Power Supply Power Supply Power Supply Power on delay Specs Supplied by the Dupline bus on the local bus Typ. 2 s Dupline Voltage Maximum Dupline voltage Minimum Dupline voltage Maximum Dupline current Addressing 8.2 V 10 V 5.5 V 10mA No addressing is needed since the module is provided with a specific identification number (SIN): the user has only to insert the SIN number in the SH tool when creating the system configuration. Used channels: 4 output channels. 4

Outputs Load Test Conditions Typical Number of Operations 250V, 12A, cosɸ=1 1800/h, 50%, DC, +70 C 1.0 x 10 5 250V, 8A, cosɸ=1 1800/h, 50%, DC, +70 C 3.5 x 10 5 250V, 4A, cosɸ=1 1800/h, 50%, DC, +70 C 5.0 x 10 5 250V, 3A, cosɸ=1 1800/h, 50%, DC, +70 C 7.5 x 10 5 230V, 550W filament lamps Iin <40A peak 60/h, 8% DC, +22 C 2.5 x 10 5 Ioff = 2.5A 230V, 1000W filament lamps Iin <71.5A peak 60/h, 8% DC, +25 C 7.0 x 10 4 Ioff = 4.5A 230V, 900W fluorescent tubes (25x36W) 360/h, 50% DC, +25 C 7.0 x 10 5 parallel compensated, 30mF 230V, compressor Iin <21A peak 500/h, 20% DC, +25 C 1.7 x 10 4 Ioff = 3.5A 250V, 8A cosɸ = 0.3 360/h, 50% DC, +25 C 1.0 x 10 5 Mode of operation Working Mode If the is connnected to the Dupline bus and the bus is working properly, the relay module is in STANDARD mode and the green LED is ON. The relay enters LOCAL mode if the push button is pressed. In LOCAL mode the relay does not accept any command from the bus and the green LED will be flashing. The relay can go back to STANDARD mode after one of the following events: 1) After a timout of 1 minute after a button press 2) After a power cycle. If the bus is not connected or faulty, the module is not powered and the outputs maintain the last status they had. No fail-safe condition is present. To have a low power consumption, the 4 outputs are not activated all together at the same time, but a delay of 500ms is present between two consecutive activations. Push button The push button is used for local switching ON/OFF of the outputs, without needing to connect the bus for test purposes. With a short press, the user enters LOCAL mode and the green LED will be flashing: at the same time all the 4 outputs will be switched ON, if at least one of them is OFF. If all the outpus are ON they will be switched OFF. 5

LEDs Indication Red LED: 4 output LEDs. Output1: ON if output1 active, OFF if output1 OFF. Output2: ON if output2 active, OFF if output2 OFF. Output3: ON if output3 active, OFF if output3 OFF. Output4: ON if output4 active, OFF if output4 OFF. When a relay is swiched on/off, all the LEDs are switched off to reduce current consumption. All blinking together: the voltage on the Dupline bus is not sufficient to supply the relay. (Vbus <5.5 V) Green LED: Power status. ON: supply ON. OFF: supply OFF. Flashing: LOCAL MODE active. Yellow LED: if the Dupline bus is working properly, it is always ON. It is OFF if the bus is OFF or not connected. Connection Diagrams LIN3 L IN4 LIN2 LIN1 6

References Further reading Information Document Where to find it Sx2WEB installation guide System manual www.productselection.net/manuals/uk/system_manual.pdf Sx2WEB software manual Sx tool manual www.productselection.net/manuals/uk/sx_tool_manual.pdf Order code CARLO GAVAZZI compatible components Purpose Component name/code Notes Controller Sx2WEB24 Bus Generator SH2MCG24 COPYRIGHT 2015 Content subject to change. Download the PDF: www.productselection.net 7