PT9 Cable ctuated Sensor Industrial.. m 0..m bsolute Linear Position to 550 inches ( meters) luminum or Stainless Steel Enclosure Options VLS Option to Prevent Free-Release Damage IP68 / NEM 6 Hazardous rea Certification GENERL 7.9 [0 mm] spring loaded cable reel Output Signal... m* (0% fs.) (00% fs.) cable extension 5. [5 mm] The PT9 is a great value for demanding long-range applications requiring a - m linear position feedback signal. Sealed to meet NEM standards, this Cable-Extension Transducer will perform even under the harshest of environmental conditions. s a member of our innovative family of NEM- rated cable-extension transducers, the PT9 offers numerous benefits. It installs in minutes, functions properly without perfectly parallel alignment, and when its cable is retracted, it measures only 6. *Optional -wire, 0...m output signal available. Full Stroke Range Options 0-75 to 0-550 inches (on this data sheet) Output Signal Options... m (-wire) and 0... m (-wire) ccuracy ± 0.% full stroke Repeatability ± 0.05% full stroke Resolution essentially infinite Measuring Cable Options stainless steel or thermoplastic Enclosure Material powder-painted aluminum or 0 stainless steel Sensor plastic-hybrid precision potentiometer Potentiometer Cycle Life 50,000 Max. Retraction cceleration see ordering information Max. Velocity see ordering information Weight, luminum Enclosure 8 lbs. max. Weight, Stainless Steel Enclosure 6 lbs, max. ELECTRICL Input Voltage see ordering information Input Current m max. Maximum Loop Resistance (Load) (loop supply voltage 8)/0.0 Circuit Protection 8 m max. Impedance 00M ohms @ 00 VDC, min. Output Signal, Zero djust up to 50% of full stroke range Output Signal, Span djust to 50% of factory set span ENVIRONMENTL Enclosure NEM /X/6, IP 67/68 Hazardous rea Certification see ordering information Operating Temperature -0 to 0 F (-0 to 90 C) Vibration up to 0 g to 00 Hz maximum Thermal Effects, Zero 0.0% f.s./ F, max. Thermal Effects, Span 0.0%/ F, max. EMC COMPLINCE PER DIRECTIVE 89/6/EEC Emission / Immunity EN5008- / EN5008- SENSOR SOLUTIONS /// PT9 PGE
PT9 Industrial m / 0 m Output Signal Fig. - Outline Drawing (8 oz. cable tension option only): 0.85 [.6] 6.5 ±0.06 [5, ±,5] mounting hole detail 0.6 [6,] eyelet detail Ø.9 [,9]* Ø.75 [9,5]** 0.7 [6,9].65 [,9]**.80 [,9].0 ±0.08 [7,9 ±,0] full extension full retraction.5 ±0.08 [,8 ±,0] DIMENSION (INCHES) MESURING CBLE RNGE Ø.0 in. Ø.0 in. Ø.07 in. Ø.06 in. 75 n/a 0. 0.9 0.7 00 n/a 0.9 0.9 0.9 50 n/a 0. 0.59 0.7 0 n/a 0.58 0.79 0.98 50 n/a 0.7 0.98. 00 n/a 0.88.8.7 50 n/a.0.8.7 00 n/a.7.57.96 50 n/a..77 n/a 500 n/a.6.97 n/a 550.6.6 n/a n/a.90 [,5] 0.5 [6,] 5.6 [,] max..75 ±0.06 [,7 ±,0] 7.87 [99,9] max. 5.0 [,6] DIMENSIONS RE IN INCHES [MM] tolerances are 0.0 IN. [0.5 MM] unless otherwise noted. * tolerance = +.005.00 [+..0] ** tolerance = +.005.005 [+..] Ordering Information: Model Number: PT9- - - 0 order code: R B C D E F G Sample Model Number: PT9-0500 - - 0 R B C E F range: enclosure/cable tension: measuring cable: cable exit: output signal: electrical connection: 500 inches aluminum/8 oz..0 nylon-coated stainless front... m, -wire 6-pin plastic connector Full Stroke Range: R order code: 0075 000 050 00 050 000 050 000 050* 0500* 0550* full stroke range, min: 75 in. 00 in. 50 in. 0 in. 50 in. 00 in. 50 in. 00 in. 50 in. 500 in. 550 in. * 6 oz. cable tension strongly recommended SENSOR SOLUTIONS /// PT9 PGE
R PT9 Industrial m / 0 m Output Signal Ordering Information (cont.): Enclosure Material and Measuring Cable Tension: order code: tension (±0%): enclosure material: max. acceleration: max. velocity: 8 oz. 6 oz. powder-painted aluminum 0 stainless steel powder-painted aluminum 0 stainless steel g g 5 g 5 g 60 inches/sec 60 inches/sec 0 inches/sec 0 inches/sec standard housing see fig. dual-spring housing see fig. Measuring Cable: B order code: cable construction: available ranges: general use: Ø.0-inch nylon-coated stainless steel rope Ø.07-inch bare stainless steel rope Ø.058-inch PVC jacketed vectra fiber rope Ø.0-inch bare stainless steel rope all ranges all ranges up to 500 inches all ranges up to 00 inches 550-inch range only indoor outdoor, debris, high temperature high voltage or magnetic field outdoor, debris, high temperature Cable Exit: C order code: front top back down Output Signals: E order code: output signal options: 5* 6*... m... m 0... m...0 m... m... m ordercode = =... m sensitivity: 6 m/full stroke ±0.5% m/full stroke ±0.5% 6 m/full stroke ±0.5% wiring configuration: wire wire wire input voltage: 8 vdc 9 vdc vdc hazardous area certification: not certified CS Output Signal Example: 0 m = m = *IMPORTNT: intrinsically safe when powered from a CS certified zener barrier rated 8 VDC max, 0 m max per installation drawing#67798 0 Hazardous rea Certification: CS Standard. Class Groups, B, C and D SENSOR SOLUTIONS /// PT9 PGE
PT9 Industrial m / 0 m Output Signal Ordering Information (cont.): Electrical Connection: F order code: 0-ft. [ M] 6-pin metal connector w/mating plug 6-pin plastic connector w/mating plug 5-ft. [7.5 M] instrumentation cable IP 67, NEM X**,6 IP 67, NEM X**, 6 IP 65, NEM IP 67, NEM 6.0 in. [78 mm]. in. [60 mm] / - 5/6" [ - 8 mm] cable dia. 6 WG max conductor size connector: MS0E-S-6P mating plug: MS06E-S-6S 0 ft. x 0.-in. dia. [ M x 0 mm dia.] 8 WG, type SJTOW /8-in. [9 mm] max cable dia. 6 WG max conductor size connector: MS0E-S-6P mating plug: MS06E-S-6S 5 ft. x 0.-in. dia. [7,5 M x 5 mm dia.] WG, shielded F order code: 5 6 7 00-ft. [0 M] 0-ft. [ M] pressure tested* 00-ft. [0 M] pressure tested* IP 67, NEM X**,6 IP 68, NEM X**, 6P IP 68, NEM X**, 6P 00 ft. x 0.-in. dia. [0 M x 0 mm dia.] 8 WG, type SJTOW 0 ft. x 0.-in. dia. [ M x 0 mm dia.] 8 WG, type SJTOW 00 ft. x 0.-in. dia. [0 M x 0 mm dia.] 8 WG, type SJTOW Notes: { 6-pin Mating Plug Waterproof Cable Instrumentation Cable pin -wire -wire 8... vdc***...9 vdc B... m out common C 0... m out D case ground B C D F E contact view color code -wire -wire WHITE 8... vdc***...9 vdc BLCK... m out common GREEN case ground 0... m out * Test pressure: 00 feet [0 meters] H O (0 PSID); Test Medium: ir; Duration: hours. ** NEM X applies to stainless steel enclosure only. *** - VDC for hazardous area option. color code -wire -wire RED 8... vdc***...9 vdc BLCK... m out common WHITE n/a n/a GREEN case ground 0... m out Output Signal Selection (not available with intrinsically safe option): 0... m or... m output signal switch setting signal board To gain access to the signal board, remove four llen-head Screws and remove end cover bracket. internal dip switches & signal board...0 m or... m dip-switch location The output signal direction can be reversed at any time by simply changing the dip-switch settings found on the internal signal board. fter the settings have been changed, adjustment of the Zero and Span trimpots will be required to precisely match signal values to the beginning and end points of the stroke. Caution! Do Not Remove Spring-Side End Cover Removing spring-side end cover could cause spring to become unseated and permanently damaged. SENSOR SOLUTIONS /// PT9 PGE
PT9 Industrial m / 0 m Output Signal Fig. Outline Drawing (6 oz. cable tension only) 5.8 ±0.06 [,6 ±,5] 0.85 [,6] mounting hole detail 0.6 [6,] eyelet detail Ø.9 [,9]* Ø.75 [9,5]**.80 [,9].90 [,5].0 ±0.08 [7,9 ±,0] full extension 0.5 [6,] full retraction.5 ±0.08 [,8 ±,0] 5.6 [,] max. 0.7 [6,9].65 [,9]** MESURING CBLE RNGE Ø.0 in. Ø.0 in. Ø.07 in. Ø.06 in. 75 n/a 0. 0.9 0.7 00 n/a 0.9 0.9 0.9 50 n/a 0. 0.59 0.7 0 n/a 0.58 0.79 0.98 50 n/a 0.7 0.98. 00 n/a 0.88.8.7 50 n/a.0.8.7 00 n/a.7.57.96 50 n/a..77 n/a 500 n/a.6.97 n/a 550.6.6 n/a n/a.75 ±0.06 [,7 ±,5] DIMENSION (INCHES) 9.5 [] max. DIMENSIONS RE IN INCHES [MM] tolerances are 0.0 IN. [0.5 MM] unless otherwise noted. 5.0 [,6] * tolerance = +.005.00 [+..0] ** tolerance = +.005.005 [+..] SENSOR SOLUTIONS /// PT9 PGE 5
VLS Option - Free Release Protection Our Velocity Limiting System (VLS) is an option for PT9000 Series cable extension transducers that limits cable retraction to a safe 0 to 55 inches per second for the single spring option and 0 to 80 inches per second for the higher tension dual spring option. The VLS option prevents the measuring cable from ever reaching a damaging velocity during an accidental free release. This option is ideal for mobile applications that require frequent cable disconnection and reconnection. It prevents expensive unscheduled downtime due to accidental cable mishandling or attachment failure. How To Configure Model Number for VLS Option:. using guide below, select PT9 model. remove PT from the model number. add VLS. completed model number! PT9-000--0 PT 9-000--0 VLS + 9-000--0 VLS9- - - 0075 thru 0550 = available options. VLS9-000--0 R B C D E F G 5 6 5 6 7 0 te.com/sensorsolutions Measurement Specialties Inc. a TE Connectivity company Measurement Specialties, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. ll other logos, products and/ or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 6 TE Connectivity Ltd. family of companies ll Rights Reserved. SENSOR SOLUTIONS /// PT9 version: 5.0 // January 0, 7 PGE 6