USER GUIDE. for. Automated purification of DNA from cells or tissue samples with

Similar documents
USER GUIDE. for. Automated purification of DNA from human or animal blood samples with

USER GUIDE. for. Automated purification of DNA from Plant leaves and seeds with

Amplification Setup Methods for the Maxprep TM Liquid Handler Technical Manual

RIDA GENE Color Compensation Kit I

Fragment Analyzer Genomic DNA Analysis Kit

Fragment Analyzer Genomic DNA Analysis Kit

Fragment Analyzer CRISPR Discovery Gel Kit

RQflex 10. Manual English

Fragment Analyzer SS NGS, HS NGS & RNA Analysis Kits

Standard Operating Procedure Aria III - Irchel

Rapid Solutions for Processing Swabs & Punches PunchSolution and SwabSolution Kits 5X AmpSolution Reagent

MR.SPOT Processor REF User Manual

SECTOR Imager Performance Qualification Kit

MR.SPOT Processor REF User Manual

MR.SPOT Processor REF User Manual

1 PROTOCOL FOR FLUORESCENCE IMAGING SYSTEM. General Switch (1), (2) DG4 Lamp switch (3) DG4 Main Switch (4) LAMBDA 10-2 (5) Camera (6) Computer (7)

eblot L1 Protein Transfer System Fast Wet Transfer System for Mini Gels

SediVue Dx * Urine Sediment Analyzer User Guide

LEGEND MAX Human α-synuclein ELISA Kit with Pre-coated Plate Catalog No.: (Previously Covance Cat. No. SIG-38974)

ab FirePlex Immunoassay Human Key Cytokines 17-plex Protocol Booklet

AU5800 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU5800 Weekly (Analyzer and ISE) Maintenance

FACSAria I Standard Operation Protocol Basic Operation

Checking the fluids of the cart

Pulse Biomedical QRS-Card Tango M2 Interface Notes

Digital PCR Analysis Software version 3

Cardioline Cube Stress Tango M2 Interface Notes

1. Add Capture Antibody diluted in coating buffer. 4. Add standards, controls and samples to the plate in duplicate.

Protocol for a Cell Proliferation Assay Using the µ-slide Angiogenesis

Operation of the ACEA NovoCyte Flow Cytometer

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

4.1 PRESSURE ADJUSTMENT Adjustment of Pressure Detector Circuit Adjustment of Pressure Indication...2

MANUAL Real time one step

Instrument Care. Band. Instruction Pack. Print and hand out! Instruments:

WQ Series Water Quality Bench top Meters

In Situ Hybridization Protocol Cryosections

Speed Performance Reliability. Medicinal Chemistry Natural Products Peptides & Polymers Organic Synthesis Purifications

COSMED Quark CPET metabolic cart Tango M2 Interface Notes

bio bas.1 USER S MANUAL

Analysis and sorting of cells with FACSAria II flow cytometer Tiina Pessa-Morikawa / Revised

VISSIM TUTORIALS This document includes tutorials that provide help in using VISSIM to accomplish the six tasks listed in the table below.

Vortex Mixers. Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Asia Pacific

GC Accessories. Accessories. Prep and Load Platform. PAL is a registered trademark of CTC Analytics AG Switzerland

Mortara XScribe Versions 3.xx and 5.xx Tango M2 Interface Notes

Import and quantification of a micro titer plate image

NimbleGen Arrays User s Guide. CGH Analysis. For life science research only.

Gel-sealed in-line fiber optic closure

V17. Quick Guide. Smart Media Player A new way to watch live TV & online entertainment

Quinton Q-Stress Version 6.x.x Tango M2 Interface Notes

Batching and Mixing. Charles Stark North Carolina State University

Optiflex Interactive Video System

Connectivity accessories by Nestor Cables

Accessories. Prep and Load Platform. PAL is a registered trademark of CTC Analytics AG Switzerland

IPC-WBT-80C ESD Control Instructor Certification Program USER S GUIDE

Philips StressVue Tango M2 Interface Notes

Setup Guide. Read me BefoRe unpacking!

FACT Cable Termination Unit

Medset FLASHLIGHT ERGO Tango M2 Interface Notes

FOSC 450 C6 and D6 Closures

***Please be aware that there are some issues of compatibility between all current versions of EndNote and macos Sierra (version 10.12).

Accessory Catalogue 2006

Modbus for SKF IMx and Analyst

*All Models include lift out basket and Instruction Manual

GE CardioSoft (Version 6.01 or higher) Tango M2 Interface Notes

Transmitter Interface Program

CytoFLEX Flow Cytometer Quick Start Guide

Standard Operating Procedure Of The CytoFLEX S Flow Cytometer At The Institute Of Virology

Delmar Reynolds CardioDirect 12-S with CardioCollect Interface Tango M2 Interface Notes

CyAn User Manual. Flow & Mass Cytometry Center Biomedical Core facility. Technion Faculty of Medicine

Disclaimer and Copyright

DVB-T Box, USB Monheim/Germany Tel. +49 (0)9091/ Fax +49 (0)9091/ Hama GmbH & Co KG.

PAL LSI - Robust and Reliable Sample Handling

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

EndNote Workshop. King Abdulaziz University. Center for Teaching & Learning Development. Done by: Jamilah Al-Amri

Schiller AT-10 plus Tango M2 Interface Notes

MICROPLATE LUMINOMETER. Operating Manual. Dated: 3/7/2002 Version: C Part Number:

Replacing the Tubes

Kratos AXIS Ultra DLD X-ray Photoelectron Spectrometer Instructions

The Complete Guide to Music Technology using Cubase Sample Chapter

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

F7000NV ROBOT VISION OPERATING MANUAL

QuantaSoft Version 1.7 Regulatory Edition Software

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

3.22 Finalize exact specifications of 3D printed parts.

Accessory Catalogue. Where design meets performance. CTC Analytics AG Industriestrasse 20 CH-4222 Zwingen Switzerland

Burdick Quest Tango M2 Interface Notes

UNIVERSITY OF PRETORIA. Dept of Library Services RefWorks (Pt 2) 2011

PAL LSI - Robust and Reliable Sample Handling

Marquette Case 12, Case 15, Case 16, and Centra Stress Systems Tango M2 Interface Notes

F24X DSK Setup and Tutorial

Data Acquisition Instructions

TL-2900 AMMONIA & NITRATE ANALYZER DUAL CHANNEL

ADS Basic Automation solutions for the lighting industry

CFlow User Guide. Science is hard. Flow cytometry should be easy.

Word Tutorial 2: Editing and Formatting a Document

1. Get support Attention Safety Caution Applications View Cameras on Screen (ex. HD TV or PC monitor) 3. Change Time Zone 5

Analog BBD Stereo Flanger. User Manual

MY-HITE ADJUSTABLE TABLE

Library ebooks and Your Sony ereader

Sofia Strep A FIA Page 1 of 5

Transcription:

USER GUIDE for Automated purification of DNA from cells or tissue samples with KingFisher 96/ KingFisher ml instrument and MACHEREY-NAGEL NucleoMag 96 Tissue kit 10.11.2006

Descripition Purification of DNA from cells or tissue (e.g. mouse tails) samples with MACHEREY- NAGEL s NucleoMag 96 Tissue kit can easily be automated using KingFisher instruments (Thermo Electron Corporation). The KingFisher platforms utilize patented technology where magnetic rods move particles through the processing steps. KingFisher 96 instrument operates on microplates and can process up to 96 samples per run, whereas KingFisher ml can handle 15 samples per run. With both instruments the volumes handled can be up to 1 ml. Typically, DNA isolation from 20 mg of mouse tail clippings using KingFisher instruments results up to 20 µg DNA. Generally, DNA yields vary according to sample type and storage conditions. The protocol described here is designed for general use and can be modified according to customer individual needs using KingFisher Software provided with the instrument. Important notes See MACHEREY-NAGEL NucleoMag 96 Tissue kit user manual for reagent storage, product use limitations, safety information etc. Resuspend magnetic beads (DNA Binding Beads) thoroughly before use. KingFisher 96 protocol Importing protocols from the web KingFisher Software protocol for MACHEREY- NAGEL NucleoMag 96 Tissue kit can be downloaded from the website (www.thermo.com/kingfisher). First you have to save the file "NucleoMagTissueKF96" to your computer. 1. Open KingFisher Software. 2. Select Protocol Import/Export data. 3. Click Read file. 4. Select the database (*.KF2) by browsing in the Open dialog and click Open. 5. Select the protocol(s) you wish to import from the Protocols in file list. Use the SHIFT key together with the mouse button to select protocols between two clicked protocols and the CTRL key to select only the clicked protocols. 6. Tick Update existing if you wish to overwrite the protocols with identical protocol name(s) in the target database. 7. Click Import. If there are protocols with identical names and you have not ticked the Update existing tick box, you will be prompted to change the name of the protocol that is being imported: - Type in a new name and click OK. o Note: Check that the name of the protocol does not exceed 17 characters. - You will receive a message stating whether the database updating procedure was successful or not. Sample preparation KingFisher DNA protocol NucleoMag TissueKF96 is designed to purify DNA from tissue samples, cells or bacteria). Use Microtiter 96 DW plate (Catalog No. 95040450), KingFisher 96 tip comp for DW magnets (Catalog No. 97002534) and KingFisher 96 KF plate (Catalog No. 97002540) with NucleoMag 96 Tissue protocol. Add sample and other reagents except Elution Buffer supplied by NucleoMag 96 Tissue kit to KingFisher deepwell microplate according to table 1 and instructions below. Add the Elution Buffer to KingFisher 96 plate and start the NucleoMagTissue_KF96 process. 2

KingFisher 96 process Table 1 Pipetting instructions for KingFisher 96 and NucleoMag 96 Tissue protocol. Plate * Plate Content Sample/ Reagent volume Lysed Sample 225 µl Magnetic Beads (added after lysis 24 µl A 1 step) Binding buffer MB2 (added after lysis step) 360 µl A 2 Wash buffer MB3 600 µl A 3 Wash buffer MB4 600 µl A 4 Wash buffer MB5 800 µl B 5 Elution buffer MB6 100 µl *A = Microtiter 96 DW plate, B = KingFisher 96 KF plate 1. Add 205 µl of buffer T1 and 20 µl of proteinase K solution to sample. Performe lysis at 56 C for 1h -16h depending on samples. Following lysis load lysed sample, 24 µl of resuspended Magnetic Beads and 360 µl Binding Buffer MB2 to plate 1. 2. Add 600 µl of Wash Buffer MB3 to plate 2. 3. Add 600 µl of Wash Buffer MB4 to plate 3. 4. Add 800 µl of Wash Buffer MB5 to plate 4. 5. Add 100 µl of Elution Buffer MB6 to plate 5. 6. Combine the tip comb and The KingFisher plate. See KingFisher 96 User manual. 7. Select the NucleoMag 96 Tissue protocol using arrow keys and press START button. 8. Load the plates according to protocol request and press START after every plate to confirm the action. 9. Note! Confirm that the plates are placed in correct orientation: A1 well to be pointed to upper right corner of the plate holder in turntable. A1 row of the plate is then always located in the inner circle of the turntable. 10. The purification protocol will start when the last plate is loaded and START button is pressed. 11. After lysis-step add 24 µl of resuspended Magnetic Beads and 360 µl of Binding Buffer MB2 to plate 1. Beads and Binding buffer may be premixed before addition to plate 1. 12. After the purification process is completed the plates are removed according to instructions shown in instrument screen. Press START after each plate removal to confirm the action. 13. When the last plate is removed text End_of _run will appear. Press STOP to complete the run. Description of NucleoMag 96 Tissue protocol with KingFisher 96 1. Samples are lysed with buffer T1 and proteinase K for 1-16 h at 56 C. Lysis incubation time depends on sample type. Refer NucleoMag 96 Tissue kit protocol for details. Following Lysis all further steps are done on the KingFisher 96 instrument. 2. Lysed samples are incubated first with magnetic beads and Binding Buffer MB2 in plate 1 for 5 minutes. Magnetic bead/dna complexes are formed. 3. Magnetic beads are washed with Wash Buffer MB3 and MB4 in plates 2 and 3 4. A final short wash step of magnetic beads with Wash buffer MB5 in plate 4 removes ethanol from previous wash buffers. 5. DNA is released to Elution Buffer in plate 5 for 10 minutes with heating. 6. Beads are discarded into plate 3. 3

KingFisher ml protocol Importing protocol from the web KingFisher ml Software protocol for NucleoMag 96 Tissue kit can also be downloaded from the website (www.thermo.com/kingfisher). Save the file "NucleoMagTissueKF_mL" to your computer. Sample preparation KingFisher ml DNA protocol NucleoMag TissueKFmL is designed to purify DNA from tissue samples, cells or bacteria). Use KingFisher ml tubestrips and tip combs (Catalog No. 97002141) with NucleoMagTissueKFmL protocol. Add sample and other reagents supplied by NucleoMag 96 Tissue kit to KingFisher ml tubestrips according to table 2 and instructions below. KingFisher ml process Table 2 Pipetting instructions for KingFisher ml and NucleoMag 96 Tissue protocol. Tube A Sample/ Reagent Content volume Lysed Sample 225 µl Magnetic Beads 24 µl Binding Buffer MB2 360 µl B Wash buffer MB3 600 µl C Wash buffer MB4 600 µl D Elution buffer MB5 800 µl E Elution buffer MB6 100 µl 6. Close the front lid and start the process by selecting intended protocol NucleoMagTissue_KFmL using arrow keys and by pressing START. 7. Remove the tube strip tray from the KingFisher ml after program has completed. Description of NucleoMag 96 Tissue protocol with KingFisher ml 1. Samples are lysed with buffer T1 and proteinase K for 1-16 h at 56 C. Lysis incubation time depends on sample type. Refer NucleoMag 96 Tissue kit protocol for details. Following lysis all further steps are done on the KingFisher ml instrument. 2. Lysed samples are incubated first with magnetic beads and Binding Buffer MB2 for 5 minutes in the tube strips A. Magnetic bead/dna complexes are formed. 3. Magnetic beads are washed with Wash Buffer MB3 and MB4 in tube strips B and C 4. A final short wash step of magnetic beads with Wash buffer MB5 in tube strip D removes ethanol from previous wash buffers. 5. Sample is released to Elution Buffer MB6 in tube strip E. Optionally: The sample is then moved manually to 1.5 ml reaction tube and incubated in a heat block for 10 minutes to release the DNA. The sample is then moved back to tube strip E. 6. Beads are discarded into tube strip C. 1. Place an appropriate number of tube strips needed for the samples (one tube strip per sample) into removable tube strip tray. 2. Add 225 µl of lysed sample 24 µl of Magnetic Beads and 360 µl of Binding Buffer MB2 to tube strip A. 3. Add 600 µl of Wash Buffer MB3 and Wash Buffer MB4 to tube strip B and C 4. Add 800 µl of Wash Buffer MB5 to tube strip D. 5. Add 100 µ of Elution Buffer MB6 to tube strip E. 4

Trouble shooting 1. Low yield Elution buffer volume insufficient Beads pellet must be covered completely with elution buffer Partial elution in Wash Buffer MB5 already Keep the beads on the magnet while washing in Wash Buffer MB5. Do not resuspend beads in this buffer, and do not incubate beads in this buffer for more than 2 min, as this buffer is water-based and might elute the DNA already. 2. Low purity Poor sample quality Check sample storage. Samples can be stored at 2 8 C for some days. Freeze samples if stored for longer periods. Insufficient washing procedure Use only recommended Deep-well blocks (see KingFisher User Manual). Carry-over of ethanol from wash buffer MB4 Increase time for washing step with buffer MB5 to 2 min. Alternatively add additional air dry step (5 min). Be sure to remove all of the ethanolic Wash Buffer MB4, as residual ethanol interferes with downstream applications. 3. Any steps of the protocol (e.g. sample incubation and elution times) and the reagent volumes can be modified with KingFisher software. 4. Tip comb was forgotten Clean the magnetic rods using a soft cloth or tissue paper soaked in mild detergent solution, soap or alcohol. Ordering Information Product Product Description no. Thermo Electron 540 05 00 KingFisher 96, 110V-240V, Magnetic particle processor 24073430 Magnet head for Deep Well plate 97002534 KingFisher 96 tip comb for DW magnets (10 x 10 pcs/box) 97002540 KingFisher 96 plate (200 µl), 48 plates/box 95040450 Deep Well 96 plate, V-bottom, Polypropylene 540 00 50 KingFisher ml, 110-240 V, Magnetic particle processor 97002131 97002141 KingFisher ml Combi 60 (tubes and tips for 60 samples) KingFisher ml Combi 240 (tubes and tips for 240 samples) 97002111 KingFisher ml tip comb, 800 pcs 97002121 KingFisher ml tube, 900 pcs (20X45 pcs) MACHEREY-NAGEL 744 300.1 NucleoMag 96 Tissue kit (1x96 preps) 744 300.4 NucleoMag 96 Tissue kit (4x96 preps) 744 300.24 NucleoMag 96 Tissue kit (24x96 preps) Contact information Ratastie 2, P.O. Box 100 FIN-01621 Vantaa Finland Tel. +358-9-329100 Fax. +358-9-32910415 www.thermo.com 5. The processor is not working properly Refer to Kingfisher User Manual Neumann-Neander Str. 6-8 D-52355 Düren Germany T. +49 (0) 2421 969-0 F. +49 (0) 2421 969 199 www.mn-net.com, email: sales@mn-net.com 5