Instruction Manual Model Ka-Band Block Downconverter

Similar documents
Instruction Manual Model

Instruction Manual Model

Instruction Manual Model Block Up/Downconverter

Instruction Manual Model BlockUpconverter

Instruction Manual Model # Block Upconverter

Instruction Manual Model Block Downconverter

Instruction Manual Model Block Upconverter

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Translator

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model 2412-x08 Multi-Channel AGC Amplifier

Instruction Manual Model Upconverter

Instruction Manual Model Downconverter

Instruction Manual Model UHF, L-Band, Up/Downconverter

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

High Performance Outdoor Test Translators

Instruction Manual Model Up/Downconverter

10MHz Source/Inserter

Model /29S RF Splitter

INSTRUCTION MANUAL. MODEL Downconverter

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Multiple Band Outdoor Block Up- and Downconverters

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Model P/03P Upconverters

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Instruction Manual Model Upconverter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

DTV742 Installation Quick Start Guide

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

DTV744 Installation Quick Start Guide

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

1/3 RACK-MOUNTED BLOCK CONVERTERS

High-Value 100 Series (Outdoor)

MULTIBAND 1/3 RACK-MOUNTED

Modular Block Converter Systems

L-Band Block Upconverter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Noise Detector ND-1 Operating Manual

X-Band Redundant LNB Systems

Ku-Band Redundant LNB Systems

C-Band Redundant LNB Systems

ipump 622 Streaming Media Decoder Installation Quick Start Guide

Synthesized Block Up- and Downconverter

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Satellite Up- and Downconverter Indoor / Outdoor

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Synthesized Block Up- and Downconverter Indoor / Outdoor

SYNTHESIZED COMMUNICATION CONVERTERS

SIR MICROWAVE WIDEBAND DSP RECEIVERS UP TO 26.5 GHz. WIDE FREQUENCY RANGE: GHz

L-Band Block Up- and Downconverter Indoor / Outdoor

MODEL Band Channels Up/Down IF In/Out RF In/Out Step Size Remote M&C Price

NS-3 RF Noise Source Operation Manual

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

Installation & Operational Manual

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Satellite Up- and Downconverter

USB-TG124A Tracking Generator User Manual

Video Extender DS128 DSRXL. Instruction Manual. 8-Port Cat5 VGA Digital Signage Broadcaster with RS232 and Audio

SIDC-5004 VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Inmarsat Downconverter Narrowband Downconverter

Professional Media Server Quick Start Guide

DVISm. DVISm - Mini Digital Video Insertion System. Quick Start Guide. Patent Pending

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

EEG A1452 SCTE-104 Inserter Frame Card

IRIG-B PTP Clock Converter Output Module Hardware Installation Manual

BRIGHTLINK HDMI EXTENDER OVER ETHERNET - H METER MODEL: BL-EXT-IP-264

Satellite Up- and Downconverter

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

LPT-3000 Remote User s Guide (LPT-3000R) LP Technologies

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

Video Server SED-2100R/S. Quick Installation Guide

INT-DS2 DVB-S/S2 SATELLITE MODULATOR DVB MODULATOR

CC2000 SERIES SYSTEM CLOCKS / DISPLAYS

OTX Optical Transmitter. Operation Instructions

The Art of Engineering

4 x 4 VGA Matrix Switch

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

DUAL/QUAD DISPLAY CONTROLLER Operation Manual

Agilis Fiber Optic Transceiver AFOT Series

MyM-3S Micro Master. Installation Guide. English. design for TV

DESCRIPTION APPLICATIONS AGILE IF TO L-BAND/RF AZIMUTH SERIES UP/DOWN FREQ CONVERTER NTC/2142

Product Catalogue January 2018

Transcription:

Instruction Manual Model 4116-200 Ka-Band Block Downconverter Weather Resistant Unit October 2014, Rev H Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc, but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc for purposes of operating the equipment When ordering parts from Cross Technologies, Inc, be sure to include the equipment model number, equipment serial number, and a description of the part CROSS TECHNOLOGIES, INC 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB wwwcrosstechnologiescom E-MAIL info@crosstechnologiescom

INSTRUCTION MANUAL MODEL 4116-200 Ka-Band Downconverter, Weather Resistant Unit TABLE OF CONTENTS PAGE Warranty 2 10 General 3 11 Equipment Description 3 12 Technical Characteristics 4 20 Installation 5 21 Message Protocol 5 22 M&C Commands 6 23 M&C Queries 7 24 Ethernet Interface Installation 9 241 Methods of Connection 9 242 Ethernet Configuration 9 243 Web page M&C 10 244 SNMP Configuration 11 25 Downconverter Outline Drawings 14 26 Physical Interface 15 27 Installation/Operation 16 WARRANTY - The following warranty applies to all Cross Technologies, Inc products All Cross Technologies, Inc products are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies, Inc s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc s option, replacing parts, subassemblies, or entire assemblies Cross Technologies, Inc shall not be liable for any special, indirect, or consequential damages This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use All shipping costs for warranty repairs will be prepaid by the customer There are not other warranties, express or implied, except as stated herein CROSS TECHNOLOGIES, INC 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB wwwcrosstechnologiescom E-MAIL info@crosstechnologiescom 4116-200 Manual, Rev H Page 2 10/22/14

10 General MODEL 4116-200 Ka-Band Block Downconverter, Weather Resistant 11 Equipment Description The 4116-200 Ka-band Block Downconverter converts 177-212 GHz to 095-195 GHz in four selectable fixed bands Front panel LEDs provide indication of DC Power and PLL Alarms The L-band to RF gain is +30 db Connectors are Super SMA female for RF In and RF Monitor, SMA female for external reference input and output, and Type N female for L-band out Gain, band select, and internal 10 MHz frequency are controlled by the Ethernet M&C In AUTO, the 10 MHz reference stays in external if the external level is in the +2 to +8 dbm range The unit is powered by a 100-240 ±10% VAC power supply, and is mounted in a 8 W X 6 H X 16 D Weather Resistant* enclosure NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in the elements (water, sleet, snow, etc) but they are not designed to be submerged under water If an extended temperature range is required, there is an Extended Temperature option (Option W21; -30 C to +60 C) available at an additional cost Contact Cross for quote STATUS / CONTROL ETHERNET J6 J7 CROSS TECHNOLOGIES INC POWER AC IN J8 FUSE F1 MODEL 4116 Downconverter RF INPUT RF MON J1 J2 10M IN J3 ALARM 10M OUT J4 L- BAND OUT J9 Model 4116-200 Ka-Band Block Downconverter Front Panel 177 to 212 GHz IN +10 RF MON S P LI SW,PLL,ATT,VCC CONTROL CONTROLLER M&C T 177 to 212 GHz BP I S O L 395, 415 GHz 137 to 1515 GHz BP 4116-200 Downconverter Block Diagram I S O L 545, 605 GHz DOWNCON-529 A T T BD1,3-128 GHz BD 2,4-132 GHz 10 M TO PLLS REV A 6/23/09 2 GHz LP V A R EXT 10 M 10 M MON 095 to 195 GHz OUT FIGURE 1 Model 4116-200 Ka-Band Block Downconverter Block Diagram 4116-200 Manual, Rev H Page 3 10/22/14

12 Technical Characteristics TABLE 10 4115-200 Ka-Band Downconverter Specifications** Input Characteristics Impedance/Return Loss Frequency (GHz) 50Ω/14 db Band 1-177 to 187 Band 2-183 to 193 Band 3-192 to202 Band 4-202 to 212 Noise Figure, Maximum Input Level Range Output Characteristics Impedance/Return Loss Frequency (GHz) Output Level Range Output 1 db Compression Channel Characteristics Gain at Fc Image Rejection Spurious, Inband Spurious, Out of band Intermodulation Frequency Response Frequency Sense LO Characteristics LO Frequency Frequency Accuracy 10 MHz Level In/Mon 20 db maximum gain -50 to -30 dbm 50Ω/14 db 095 to 195 GHz -20 to 0 dbm +10 dbm, Maximum Gain +30 ±3 db, (+30 to 0 db variable in 05 db steps) > 60 db, minimum SIGNAL RELATED <-50 dbc, -15 to 0 dbm out; 2XFo <-45 dbc SIGNAL INDEPENDENT, <-60 dbm; 95-195 GHz Out, Gmax <-55 dbm, SIGNAL INDEPENDENT; 05-245 GHz Out <-50 dbc for two carriers at 4 MHz spacing, each at -5 dbm Out ±2 db, over RF band; ± 05 db, 40 MHz BWs Non-inverting Band Specific ±005 ppm maximum over temp internal reference; external reference input +2 to +8 dbm in; Monitor Output = input level ± 10 db, 50 ohms Phase Noise @ Freq Hz > 100 1K 10K 100K 1M dbc/hz -65-75 -80-95 -105 Controls, Indicators Gain, Band, 10M Freq PLL Alarm Power Gain, band select, and internal 10 MHz frequency via Ethernet M&C or Status/Control Connector Red LED, External Contact Closure Green LED 4116-200 Manual, Rev H Page 4 10/22/14

12 Technical Characteristics (Continued from page 4 ) Other RF In, Monitor Connector L-Band Connector 10 MHz Connectors Weather Resistant* Connectors Size Power Super SMA (37 GHz) (female), 50Ω Type N (female), 50Ω SMA (female), 50Ω Status/Control Connector, MS3112E14-18S; Mating Cable Connector, MS3116F14-18P Ethernet Conector, RJF21B; Mating Cable Connector, RJF6G; Cable interface, Standard RJ45 AC Input Connector, Clipper Series, CL1M1102, Mating Cable Connector, CL1F1101 (Unless otherwise specified, the mating connector is provided preassembled onto a standard NEMA 5-15 US power cord) 8 Wide X 6 High X 16 Deep, Weather Resistant* Enclosure 100-240 ±10% VAC, 47-63 Hz, 25 watts maximum **+0 to +50 degrees C; Specifications subject to change without notice 2014 Cross Technologies, Inc *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in the elements (water, sleet, snow, etc) but they are not designed to be submerged under water If an extended temperature range is required, there is an Extended Temperature option (Option W21; -30 C to +60 C) available at an additional cost Contact Cross for quote 4116-200 Manual, Rev H Page 5 10/22/14

20 Installation The 4116-200 Ka-Band Downconverter consists of a 8 W X 6 H X 16 D Weather Resistant enclosure A switching, ±12, +24, +5 VDC power supply provides power for the internal assemblies The 4116-200 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels See Figure 25 for mounting dimensions Figure 2-4116-200 Front Panel 201 Connection to AC Input Power The 4116-200 is furnished with a pre-assembled AC power input cable as described below 4115-31 Power Input Connector, FCI Clipper Series, CL1M1102 & Crimp Pins Mating Connector FCI Clipper Series, CL1F1101, Crimp Pins and CL101021 Backshell Pin Input Connector Pin Description 1 100-240 ±10% VAC, 47-63 Hz, 20 watts max 2 Neutral 3 Ground 21 Message Protocol The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit All messages consist of ASCII printable characters so standard terminals and terminal emulator programs may be used to control and monitor the unit All messages begin with the open bracket character { (ASCII 0x7B) and end with the close bracket character } (ASCII 0x7D) Messages consisting of commands to set or change operating parameters and modes of the unit begin with C (ascii 0x43) followed by a command specific character Messages consisting of queries to report operating parameters and modes begin with S (ASCII 0x53) followed by a parameter specific character 4116-200 Manual, Rev H Page 6 10/22/14

22 M&C Commands The following tables summarize the commands and status queries applicable to the 4116-200 Block Downconverter * PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected Table 20 - Model 4116-200 Downconverter M&C Commands Table 20: Model 4116-200 M&C Commands Command Set Frequency Band Syntax {aacbx} Description where: x = 1 to select band 1: in = (177 to 187 GHz) out = (950 to 19500 MHz) x = 2 to select band 2: in = (183 to 193 GHz) out = (950 to 19500 MHz) x = 3 to select band 3: in = (192 to 202 GHz) out = (950 to 19500 MHz) x = 4 to select band 3: in = (202 to 212 MHz) out = (950 to 19500 MHz) Set Gain {aacgxxx} where: xxx = 3 characters Range: 300 to 000 (+30 to 0 db variable in 05 db steps) Set Serial Interface {aacix} where: x = 0 to select RS232 x = 1 to select RS422 x = 2 to select RS485 Set RS485 address {aacrxx} where: xx = 2 characters Range: 00 to 31 Set Int 10 MHz reference offset {aacoxxxxx} where: xxxxx = 5 characters Range: +2000 to +8000 4116-200 Manual, Rev H Page 7 10/22/14

23 M&C Queries Table 21 - Model 4116-200 Downconverter M&C Queries Table 21: Model 4116-200 M&C Queries Queries Syntax Frequency Band {aasb} Description Returns {aasbx} where: x = 1 if band 1 is selected in = (177 to 187 GHz) out = (950 to 1950 MHz) x = 2 if band 2 is selected in = (183 to 193 GHz) out = (950 to 1950 MHz) x = if band 3 is selected in = (192 to 202 GHz) out = (950 to 1950 MHz) x = if band 4 is selected in = (202 to 212 MHz) out = (950 to 1950 MHz) Gain {aasg} Returns {aasgxxx} where: xxx = 3 characters Range: 300 to 000 (+30 to 0 db) Example: {aasg245} indicates the current gain setting is 245 db 10 MHz reference {aase} Returns {aasex} where: x = 1 if Internal 10 MHz reference is selected x = 2 if External 10 MHz reference is selected x = 3 if Auto 10 MHz reference is selected Serial Interface {aasi} Returns {aasix} where: x = 0 if RS232 is selected x = 1 if RS422 is selected x = 2 if RS485 is selected RS485 address {aasr} Returns {aasaxx} where: xx = 2 characters Range: 00 to 31 continued on page 8 4116-200 Manual, Rev H Page 8 10/22/14

Table 21 - Model 4116-200 M&C Queries (Continued from page 7) Table 21: Model 4116-200 M&C Queries - Continued Queries Int 10 MHz reference offset Syntax {aaso} Description Returns {aasoxxxxx} where: xxxxx = 5 characters Range: -2000 to 2000 Unit Status {aasa} Returns {aasaxy} where: x = 0 if no summary alarm, x = 1 if summary alarm y = 0 if unit is using internal 10 MHz ref, y = 1 if unit is using external reference Internal Temperature {aast} Returns {aastxxx} where: xxx = 3 characters Range (-99 to +99) degrees Celsius Model and firmware revision {aasv} returns {aasvxxxxxxxxyyyy} where: xxxxxxxx = unit model number yyyy = unit firmware rev 4116-200 Manual, Rev H Page 9 10/22/14

24 ETHERNET Interface Installation and Operation The 4116-200 Block Downconverter is equipped with a 10/100 Base-T compatible Ethernet interface for control and monitoring of its operating parameters An HTML script interface allows the user to monitor and control the converter using a standard web browser SNMP (Simple Network Management Protocol) is also supported Contact Cross Technologies for the SNMP MIB file 241 Methods of Connection Directly Connected to a PC: For control from a local PC, attach the 4116-200 s Ethernet port to the Ethernet network connector on the PC using a crossover RJ-45 cable LAN Connection For LAN connections, attach the 4116-200 Ethernet port to the LAN using a normal RJ-45 cable Use any PC on the LAN to connect to the 4116-200 242 Ethernet Configuration Each 4116-200 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager The 4116-200 is set at the factory with a static address of 1921681232 The device server in the 4116-200 has a built in HTTP based configuration manager that is used to configure network settings To access the configuration manager, open a web browser and enter the IP address of the 4116-200 in the browser's address field The window shown in Figure 2-A will appear As delivered, there is no password set Choose your user name and password here or leave those fields blank and click OK to proceed to the configuration manager web page Figure 2-A: Password Screen 4116-200 Manual, Rev H Page 10 10/22/14

Figure 2-B: Configuration Manager Screen In the left frame of the configuration manager click on Network to display the Network Settings screen Enter the IP address, Subnet mask, and Gateway address with delimiter dots (example: 19216819247) Click on apply settings to apply the new settings in the device server 243 Web page M & C Enter the following address in a web browser to access the M & C web page: http://<ip address of 41xx>/serial/0/setuphtm where <ip address> is the IP address of the unit Figure 2-C (page 11) shows the web page from a model 4116-200 frequency converter 4116-200 Manual, Rev H Page 11 10/22/14

Figure 2-C - Model 4116-200 Web page 244 SNMP Configuration Setting of SNMP parameters such as Community Write and Community Read strings requires a Telnet connection to port 9999 The following instructions explain how to establish such a Telnet connection using Windows XP's Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP/IP (Winsock) from the Connect using drop down menu Enter the IP address of the 4116-200 in the Host address: field and 9999 in the Port number field Figure 2-E shows an example of the Hyper Terminal settings required to access the SNMP configuration menu 4116-200 Manual, Rev H Page 12 10/22/14

Figure 2-E: - Telnet Settings in Hyper Terminal Once the Telnet connection is established you will be prompted to Press Enter for Setup Mode Press enter and a menu of device server configuration options will appear (see Figure 2-F) Select menu item 3, SNMP configuration You will be prompted to enter SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SNMP managers that will access the unit This is required even though SNMP traps are not implemented The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server 4116-200 Manual, Rev H Page 13 10/22/14

Figure 2-F - Device Server Configuration Menu 4116-200 Manual, Rev H Page 14 10/22/14

Figure 25 Shows front panel input and output connections, top view and baseplate mounting dimensions 788 662 42 STATUS/CONTROL CONNECTOR Multipurpose MS3112E14-18S 18 pin connector ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector STATUS / CONTROL ETHERNET J6 J7 CROSS TECHNOLOGIES INC POWER AC IN J8 FUSE F1 POWER IN AC input 100-240 ±10% VAC 47-63 Hz, 25 watts max Weatherized CL1M1102 Connector POWER LED Lights GREEN when DC voltage is present from AC power supply Fuse 1A/250V - 125 X 25 slow blow RF INPUT Super SMA (female), 50Ω BAND 1-177 to 187 BAND 2-183 to 193 BAND 3-192 to 202 BAND 4-202 to 212 MODEL 4116 Downconverter RF INPUT J1 RF MON J2 10M IN J3 ALARM 10M OUT J4 L- BAND OUT J9 ALARM LED Red LED indicates unit alarm L-BAND OUT PUT Type N (female) 50Ω 095 to 195 GHZ RF MONITOR Super SMA (female), 50Ω -20 to 0 dbm 10MHz INPUT SMA (female) 50Ω Insert External 10MHz) Reference here (+2 dbm +8 dbm) 10MHz OUTPUT SMA (female) 50Ω Output level 095 to 195 GHz 1/4-20 Tapped Thru, 4 Places 1200 155 15875 750 4116-200 Manual, Rev H Page 15 10/22/14

26 Physical Interface All 4115 and 4116 units provide a RS232/RS422/RS485 interface port and a 10/100 Base-T Ethernet port Both ports are available when the unit is installed and powered up Commands may be sent to either port at any time and they will be processed in the order that they are received The RS232/RS422/RS485 signals connect via a multipurpose MS3116F14-18P connector as shown in Table 26 The Ethernet signals connect via a standard RJ45 connector Table 26 - Monitor and Control Connector Monitor and Control Connector Pinout Connector part number MS3112E14-18S Mating Cable Connector part number MS3116F14-18P Pin Signal Description A Chassis Ground N Summary Alarm Normally Closed P Summary Alarm Common R Summary Alarm Normally Open E RS422/RS485 Data Out- F Signal Ground C RS422/RS485 Data In- D RS422/RS485 Data Out+, RS232 Data Out B RS422/RS485 Data In+, RS232 Data In NOTE: Planning Ethernet Access - It is recommended that IP knowledgeable customer personnel be consulted as a resource in the installation and use of the Ethernet access features of the Cross Technologies product 4116-200 Manual, Rev H Page 16 10/22/14

27 Installation/Operation Installing and Operating the 4116-200 Ka-Band Block Downconverter: 1 Connect a -50 dbm to -30 dbm signal to L-BAND INPUT, (Figure 25) 2 Connect the RF OUTPUT to the external equipment 3 Using the pre-assembled AC power input cable (furnished), connect 100-240 ±10% VAC, 47-63 Hz to AC IN connector on the front panel 4 If a custom length power cable must be made, refer to description below for connections* 5 Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 25) 6 Set the gain so that the output level is always within the range of -20 to 0 db (See Table 20 and 26) 7 Select either INT (for internal 10 MHz ref), AUTO (for internal 10 MHz ref UNLESS an external 10 MHz, +2 to +8 dbm signal is connected to J2), or EXT (for external 10 MHz, +2 to +8 dbm reference that is inserted at J2) via Ethernet or serial command (See Table 20 and 261) 8 Check that a 10 MHz, signal is present at the 10 MHz REF OUTPUT at the same level as the input, ±05 db (J4 - Figure 25) 9 AC Fuse - The fuse is a 1A/250V 125 x 25 (slow blow) and is inserted in the fuse F1 position NOTE: If a fuse continues to open, the power supply is most likely defective CAUTION: When checking or replacing the fuse, do not over tighten the fuse holder cap This can displace the cap s O-ring and the weatherproof seal will be lost 271 Connection to AC Input Power 4115-41-310 AC Power Input Connections Connector, Clipper Series, CL1M1102 and crimp pins Mating Connector, Clipper Series, CL1F1101 and crimp pins Pin Input Connector Pin Description 1 100-240 ±10% VAC, 47-63 Hz, 20 watts max 2 Neutral 3 Ground Unless otherwise specified, the mating connector is provided preassembled onto a standard NEMA 5-15P US power cord 4116-200 Manual, Rev H Page 17 10/22/14

CROSS TECHNOLOGIES, INC 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB wwwcrosstechnologiescom E-MAIL info@crosstechnologiescom Printed in USA 4116-200 Manual, Rev H Page 18 10/22/14