and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Similar documents
and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

Series CDP2 Definite Purpose Contactors

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

Series CDP2 Definite Purpose Contactors

Bulletin 190 Compact. Combination Starters

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

AC1036. Definite Purpose Contactors

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Bulletin 190 IEC Modular Starter System

Series CT7N Bimetallic Overload Relays

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

Modular pulse operated latching relay 16 A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

16 A and 25 A power contactors with or without handle

XT IEC Power Control Combination Motor Controllers

Bulletin 305 AC Starters

Data Sheet Definite Purpose Contactors Ex9CK Series

AS09..S 3-pole Contactors - Spring Terminals

Contactors and Contactor Assemblies

Definite Purpose Contactors

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Features XT SC 012 B B A

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Features XT SC 012 B B A

Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage. Example: MIL 72A STuZ-24

Magnecraft Power Relays

59.1. Motor Control and Protection. For Immediate Delivery or Tech Support call KMParts.com at (866) Product Overview.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers Catalog Number Selection... Product Selection...

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

XT Line Replacement Coils 16.1 NEMA Contactors and Starters Freedom Line... A200 Line IEC Contactors and Starters XT Line...

Bulletin 100-G IEC Contactors

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40


Bulletin 100-G IEC Contactors

Your order must include: cat. no. of the miniature contactor specified with coil voltage code and, if required, cat. no. of any accessories

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

TeSys circuit-breakers

Accessories Order No. Page Individual parts Order No. Page K1 1) K3 2) K2 2) 14 Auxiliary switch block, front. 3/105 terminals.

Catalogue Ignitors and power switches for HID

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

3AH3 Vacuum Circuit-Breakers

Switching Power Module

QSNE-4S5-230-D V~ 50 / 60 Hz 16 A. Dimming Power Module CCI. Option Def. Input. H Opt1. Hi Temp Prog Power

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

Simply clever! The digital DIN-rail time switches by Grässlin

DC Motors & Controls. DC2 DC Drives for 1/4 thru 2 Hp PMDC and Shunt Wound Motors. 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.

High performance circuit breakers

Bulletin 150, 154 Softstarters Quick Selection Table

Power Circuit of a UL508A Panel. Typical UL489 Application

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

APQ Series Type C Power Factor Correction Banks

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

Ordering details. Approval. Classification

Bulletin 500 Top Wiring For Motor Loads

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Magnetic and Hydraulic-Magnetic Circuit Breaker

AC diagonal module Ø 200 mm

Datasheet - SRB301LC 24VAC/DC

Electronic Timer Control Day Astronomic Electronic Control

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

AF-300 E11 Adjustable Frequency Drive

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

15 Series - Dimmer

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

Minicontactorrelay,2NO/2NC,DCoperated

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Part-Turn Electric Multi-Turn Electric

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Type MG-6 Auxiliary Relay Class 1E

llen-bradley 194R-HM4-NFPA3

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

Bulletin 509 Full Voltage

HS-509 VIBRATION TRIP MODULE

GRASSLIN - DEFROST TIMER GRASSLIN DTMV SERIES SPECIFIERS GUIDE

ADDENDUM PAGES: Revised Locked-Rotor Current Ratings in NEMA ICS 2 Part 2 Based on NEC 2002 and NEMA MG 1

MILLITARY SPECIFICATION SHEET

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

VAT 20 Adjustable Frequency Drive

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

ALLEN BRADLEY TIMING RELAY

Transcription:

SSN9000 Series C7 Special Use designed and labeled for specific industrial applications Special Use Capacitor switching contactors HVC rated contactors NEM size labeled contactors Lighting contactors Hydraulic elevator duty contactors The C7 line includes a number of contactors designed and labeled for specific industrial applications. In most cases, these devices are UL and CS approved for these specialized uses. Where appropriate, contactors also carry approval by specific industry associations such as RI (ir Conditioning and Refrigeration Institute). CQ7 Capacitor Switching Capacitor Switching are often used in power factor correction. Single capacitor switching and capacitor bank switching results in peak inrush currents greater than the six times FL experienced in motor starting applications. Managing the peak inrush of capacitor switching can involve the use of coils of wire to reduce the harmful inrush currents. CQ7 contactors offer a simple alternative solution by combining a built-in set of resistors and early-make contacts, factory wired in parallel with the power contacts in the body of a C7 contactor. CQ7 contactors are cul rated and labeled for capacitor switching applications. CNX Special Purpose CNX Special Purpose are rated by FL & LR as well as resistive current rated - primarily to meet the demands of the HVC and compressor markets. CNX contactors have all the flexibility of a C7 contactor like easy coil change out, DIN rail mounting and field installable auxiliaries as well as mechanical interlocks not normally associated with true definite purpose contactors. CNX contactors may also be combined with CEP7 or CT7N overload relays to make a special purpose starter. CNX starters are cul rated and labeled as well as RI (ir Conditioning and Refrigeration Institute) approved. Hydraulic Elevator Wye-Delta Most industrial wye-deltas consist of three contactors with interlocks but Hydraulic Elevators are a special application. Hydraulic Elevator wye-deltas consist of a pair of mechanically linked contactors with sufficient auxiliaries for electrical interlocks. The wye-delta is similar to a reversing contactor but the power wiring is different. We offer Hydraulic Elevator contactors with a choice power wiring inter-connections for ease of installation, or without power wiring inter-connections, allowing the elevator serviceman to make use of the existing power cables. This convenient selection of a complete assembly saves time and effort in the field. CN7 and CN6 NEM size labeled contactors CN7 and CN6 contactors are UL Listed in accordance with NEM standards publication ICS-2. CN7 and CN6 contactors are UL labeled for application under IEC KW, as well as NEM Size, for specified horsepower at various voltages. CN7/ CN6 contactors have been purposely selected larger to increase the life of the device. Only the devices listed here are available with the NEM size on the UL label. CN7/CN6 NEM sized contactors may be combined with all Sprecher + Schuh overload relays to make a NEM sized starters. C7 41

Special Use - C Coil Capacitor Switching - Series CQ7 CQ7 Three Pole Capacitor Switching With C Coil, Series CQ7 (Open type only) For pplications per UL / CS UL/CS Ratings for Switching Capacitor Banks 1-phase 60 Hz (kvar) 3-phase 60 Hz (kvar) uxiliary Open Type 115V 230V 200V 230V 460V 575V NO NC Catalog Number Price 2.2 4.5 6.5 7.5 15 18.5 1 1 CQ7-16-11-225 2 0 CQ7-16-20-225 3.6 7.5 11 12.5 20 25 1 1 CQ7-37-11-327 2 0 CQ7-37-20-327 For pplications per IEC 60947-4 (C-6b) IEC Ratings for Switching Capacitor Bank 1-phase 50 Hz - (kvar) 230V 240V 400V 415V 500V 690V uxiliary Open Type 3-phase 50 Hz - (kvar) 230V Catalog Number 240V 400V 415V 500V 690V NO NC Price Switching Capacitor Banks at 40 C 1 1 CQ7-16-11-225 2 0 CQ7-16-20-225 1 1 CQ7-37-11-327 2 0 CQ7-37-20-327 Switching Capacitor Banks at 60 C 1 1 CQ7-16-11-225 2 0 CQ7-16-20-255 1 1 CQ7-37-11-327 2 0 CQ7-37-20-327 5 8.5 9 10.5 15 8.5 15 15.5 18.5 25 8/8.5 14 14.5 17.5 24 14 25 25 30 40 5 8.5 9 10.5 15 8.5 15 15.5 18.5 25 8/8.5 14 14.5 17.5 24 14 25 25 30 40 CQ7-16-11-120 Capacitor Switching contactor Description CQ7 contactors incorporate a built-in set of resistors and earlymake contacts, wired in parallel with the power contacts, to precharge the capacitors. This manages the peak inrush common with capacitor switching. The circuitry is housed in a front mounted add-on deck. NOTE: DC and C coils are not interchangeable. CQ7-16C 37C contactors have increased dimensions to accommodate DC coils. See page 87-89 for dimensions. Coil Codes ➊ C Coil Code 50 Hz 60 Hz 24Z 24V 24V 120 110V 120V 220W ~ 208V-240V 240 220V 240V 380 380V-400V 440V 480 440V 480V 600 550V 600V ➊ Other voltages available, see page 61. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. SSN9000 42 Discount Schedule -1

Special Use - DC Coil Capacitor Switching - Series CQ7 Three Pole Capacitor Switching With DC Coil, Series CQ7 (Open type only) For pplications per UL / CS UL/CS Ratings for Switching Capacitor Banks 1-phase 60 Hz (kvar) 3-phase 60 Hz (kvar) For pplications per IEC 60947-4 (C-6b) uxiliary Open Type 115V 230V 200V 230V 460V 575V NO NC Catalog Number Price 2.2 4.5 6.5 7.5 15 18.5 1 1 CQ7-16C-11-264 2 0 CQ7-16C-20-264 3.6 7.5 11 12.5 20 25 1 1 CQ7-37C-11-400 2 0 CQ7-37C-20-400 IEC Ratings for Switching Capacitor Bank 1-phase 50 Hz - (kvar) 230V 240V 400V 415V 500V 690V 3-phase 50 Hz - (kvar) uxiliary 230V 240V 400V 415V 500V 690V NO NC Switching Capacitor Banks at 40 C Open Type Catalog Number 5 8.5 9 10.5 15 8.5 15 15.5 18.5 25 1 1 CQ7-16C-11-264 2 0 CQ7-16C-20-264 8/8.5 14 14.5 17.5 24 14 25 25 30 40 1 1 CQ7-37C-11-400 2 0 CQ7-37C-20-400 Switching Capacitor Banks at 60 C 5 8.5 9 10.5 15 8.5 15 15.5 18.5 25 1 1 CQ7-16C-11-264 2 0 CQ7-16C-20-264 8/8.5 14 14.5 17.5 24 14 25 25 30 40 1 1 CQ7-37C-11-400 2 0 CQ7-37C-20-400 Price CQ7-16C-11-24D Capacitor Switching contactor Description CQ7 contactors incorporate a built-in set of resistors and earlymake contacts, wired in parallel with the power contacts, to precharge the capacitors. This manages the peak inrush common with capacitor switching. The circuitry is housed in a front mounted add-on deck. CQ7 NOTE: DC and C coils are not interchangeable. CQ7-16C 37C contactors have increased dimensions to accommodate DC coils. See page 87-89 for dimensions. Coil Codes ➊ DC Coil Code 12D 24D ➋ 48D 110D 220D Voltage 12V 24V 48V 110V 220V SSN9000 ➊ Other voltages available, see page 62. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➋ Surge suppressor coil with integrated available. Order coil code 24DD and add $42 to list price. Discount Schedule -1 43

Technical Information Capacitor Switching - Series CQ7 CQ7 Theory of Operation Single capacitor switching is often used in power factor correction on individual loads. Inrush current at the point of becoming energized can peak to 30 times normal current (see Figure 1) depending on impedance of cables and transformers. Capacitor bank switching is often used in power factor correction on multiple loads. Inrush current at the point of becoming energized can peak to 200 times normal current (see Figure 2) because each capacitor in the bank acts as an additional power source and therefore feeds additional current to the circuit. Complications of capacitor switching with standard contactors can include nuisance tripping of the short circuit protective device, welding of main contacts, and stress on components resulting in reduced life of capacitors. Managing the peak inrush common with capacitor switching can involve complicated dimensioning in the form of over sizing standard contactors combined with adding coils of wire. CQ7 contactors offer a simple alternative solution by combining a built-in set of resistors and earlymake contacts, wired in parallel with the power contacts, to pre-charge the capacitors. The increased impedance of the CQ7 resistors is only present in the circuit during inrush. This circuitry is housed in a front mount add-on deck similar to a four pole auxiliary block, which results in a compact design and ease of selection based on applied KVR. CQ7 is available with C or DC coils and with 1 NO & 1 NC (see Figure 3) or 2 NO auxiliary contacts (see Figure 4). CQ7 contactors only show UL/CS pproved capacitor ratings on the nameplate and should not be used for switching motors. Figure 1 Figure 2 Circuit Diagrams CQ7-16- -11 and CQ7-37- -11 CQ7-16- -20 and CQ7-37- -20 (1 NO and 1 NC auxiliary contact) (2 NO auxiliary contacts) Figure 3 Figure 4 SSN9000 44 Discount Schedule -1

Special Use - C Coil Special Purpose - Series CNX Non-Reversing, Three Pole Special Purpose With C Coil (Open type only) ➊➋ Full Load mps Locked Rotor mps - 3Ø Resistive mps ➍ Maximum Horsepower 1 Ø 3 Ø uxiliary 200V 200V/ 230V 460V 575V 115V 230V 208V 230V 460V 575V NO NC Catalog Number Price 15 91 91 66 25 1-1/2 3 4 5 10 10 1 0 CNX-205-174 0 1 CNX-206-174 30 180 150 120 40 2 5 7-1/2 10 20 20 1 0 CNX-207-240 0 1 CNX-208-240 0 0 CNX-209-00- 261 40 240 200 160 50 3 5 10 10 25 25 1 0 CNX-209-10- 281 0 1 CNX-209-01- 281 0 0 CNX-212-00- 281 50 300 250 200 65 3 7-1/2 10 15 30 30 1 0 CNX-212-10- 302 0 1 CNX-212-01- 302 0 0 CNX-218-00- 452 90 540 450 360 120 ~ ~ 25 30 60 60 1 0 CNX-218-10- 472 0 1 CNX-218-01- 472 CNX-208-120 Special Purpose contactor Description Series CNX Special Purpose are standard C7 contactors that have been tested, approved and labeled by UL for heating, ventilation and air conditioning (HVC) applications. ➋ CNX Coil Codes ➌ C Coil Code 50 Hz 60 Hz 24Z 24V 24V 120 110V 120V 220W ~ 208V-240V 240 220V 277V 277 240V 440V 380 380V-400V 480V 480 440V 480V 600 550V 600V SSN9000 ➊ Special order contactors. Contact your Sprecher + Schuh representative for availability. ➋ ll CNX contactors listed here are RI (ir Conditioning and Refrigeration Institute) approved. ➌ Other voltages available, see page 61. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➍ Reference page 81 for Operation Life Data. Discount Schedule -1 45

Special Use - DC Coil Special Purpose - Series CNX CNX Non-Reversing, Three Pole Special Purpose With DC Coil (Open type only) ➊➋ Full Load mps Locked Rotor mps - 3Ø Resistive mps ➍ Maximum Horsepower 1 Ø 3 Ø uxiliary 200V 200V/ 230V 460V 575V 115V 230V 208V 230V 460V 575V NO NC Catalog Number Price 15 91 91 66 25 1-1/2 3 4 5 10 10 1 0 CNX-205C- 209 0 1 CNX-206C- 209 30 180 150 120 40 2 5 7-1/2 10 20 20 1 0 CNX-207C- 288 0 1 CNX-208C- 288 0 0 CNX-209C-00-323 40 240 200 160 50 3 5 10 10 25 25 1 1 CNX-209C-10-343 0 1 CNX-209C-01-343 0 0 CNX-212C-00-397 50 300 250 200 65 3 7-1/2 10 15 30 30 1 0 CNX-212C-10-417 0 1 CNX-212C-01-417 0 0 CNX-218D-00-575 90 540 450 360 120 ~ ~ 25 30 60 60 1 0 CNX-218D-10-595 0 1 CNX-218D-01-595 CNX-208C-24D Special Purpose contactor Description Series CNX Special Purpose are standard C7 contactors that have been tested, approved and labeled by UL for heating, ventilation and air conditioning (HVC) applications. ➋ Coil Codes ➌ CNX-205C...212C CNX-218D DC Coil Code DC Coil Code Voltage 24D ➎ 24DD ➏ 24V 110D ➎ 110DD ➏ 110V ➊ Special order contactors. Contact your Sprecher + Schuh representative for availability. ➋ ll CNX contactors listed here are RI (ir Conditioning and Refrigeration Institute) approved. ➌ Other voltages available, see page 61. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➍ Reference page 61 for Operation Life Data. ➎ DC coils for CNX-205C...212C are True DC Coils. ➏ DC coils for CNX-218D contactors are two winding DC Coil Series and include integrated diode surge suppressor. SSN9000 46 Discount Schedule -1

Reduced Voltage - C Coil Wye Delta - Series C7Y2 Hydraulic Elevator Wye Delta, with C Coils (Two Type ➊) Maximum Horsepower Three Phase Industrial pplication ➎ UL/CS Elevator Duty ➏ uxiliary Open Type 200V 230V 460V 575V NO ➍ NC ➌ Catalog No. Price 10 15 30 30 0 1 C7Y2-30-02- -LW 551 10 10 30 30 1 1 C7Y2-30-22- -LW 593 15 20 40 40 0 1 C7Y2-37-02- -LW 639 10 15 30 40 1 1 C7Y2-37-22- -LW 679 20 25 50 50 0 1 C7Y2-43-02- -LW 691 15 15 40 50 1 1 C7Y2-43-22- -LW 732 30 40 75 75 0 1 C7Y2-60-02- -LW 912 15 25 50 60 1 1 C7Y2-60-22- -LW 952 40 50 100 100 0 1 C7Y2-72-02- -LW 1033 25 30 60 75 1 1 C7Y2-72-22- -LW 1073 50 60 125 125 0 1 C7Y2-85-02- -LW 1150 30 40 75 100 1 1 C7Y2-85-22- -LW 1192 50 60 125 125 0 1 C7Y2-97-02- -LW 1390 TBD TBD TBD TBD 1 1 C7Y2-97-22- -LW 1432 HP Selection Larger sizes available, see page 100. Contact your Sprecher + Schuh representative. C7Y2-30 Wye-Delta contactor Includes: Line side coil terminations Mechanical and electrical Interlocks ➋ C7Y2-60 85 includes back pan Optional: Power Wiring available but not included (see page 59) ➊➐ Elevator controllers often require additional auxiliary contacts. ➌ C7-PWD43 C7-PWD43 C7 2M S 2M S C7-PWNM37 C7-PWNM43 SSN9000 Coil Codes ➍ C Coil Code 50 Hz 60 Hz 24Z 24V 24V 120 110V 120V 220W ~ 208V - 240V 240 220V 240V 380 380V-400V 440V 480 440V 480V 600 550V 600V C7-PWNM85 C7-60..97 2M C7-60..97 C7-PWD85 ➊ For with power wiring change catalog number suffix -LW to -PW and add the following amount: C7Y2-30 37 add $25 C7Y2-43 add $32 C7Y2-60 97 add $45 (without backpan) Ex: C7Y2-30-22- -LW becomes C7Y2-30-22- -PW. ➋ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-02) and are used to electrically interlock the contactors. ➌ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➍ Other voltages available, see page 61. Nonstandard coil voltages not listed here must be ordered and installed separately as renewal parts. ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on UL/CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C72. S Discount Schedule -1 47

Special Use - C Coil NEM Labeled - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled with C Coil ➊➌ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/3 1 1-1/2 1-1/2 2 2 1 0 CN7-12-10-155 Price 0 1 2 3 3 5 5 1 0 CN7-16-10-174 CN 1 2 3 7-1/2 7-1/2 10 10 1 0 CN7-37-10-288 2 3 7-1/2 10 15 25 25 1 0 CN7-43-10-308 CN7 NEM labeled contactor (C) 3 7-1/2 15 25 30 50 50 1 0 CN7-85-10-482 4 ~ ~ 40 50 100 100 1 1 CN6-180-11-1608 CN6-180-EI-11-1850 5 ~ ~ 75 100 200 200 1 1 CN6-300-EI-11-2375 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 61 for CN7 coils and pages 106-108 for C(N)6 coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See pages 52-53 (C[N]7) and page 104 (C[N]6). vailable as open units or in NEM 1, 3R, 4, 4X and 12 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. NEM sized starters with C Coils are listed on page C26. Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 101 for ordering information. CN7 C Coil Codes ➋ CN7-12...85 C Coil Code 50 Hz 60 Hz 24Z 24V 24V 120 110V 120V 220W ~ 208V-240V 240 220V 240V 380 380V-400V 440V 480 440V 480V 600 550V 600V CN6 C Coil Codes Conventional Coils ➋ CN6-180 C Coil Code 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 240B 220-230V 260V 380 380V-400V 440V 480 415V 480V 575 500V 575V CN6 C Coil Codes EI Electronic Coils ➋➌ CN6-180-EI...300-EI C Coil Code 50 Hz / 60 Hz 24 ➍ 24V 120 110-130V 220W 208-277V 460W 380-500V ➊ Refer to page 87 for CN7 dimensional information and page 127 for C(N)6 dimensions. ➋ Other voltages available, see page 61 for CN7 and pages 106-107 for C(N)6. Nonstandard coil voltages not listed here must be ordered and installed separately as renewal parts. ➌ -EI designates contactor with Electronic Interface coil. ➍ 24 V C coil not available for CN6-300-EI. SSN9000 48 Discount Schedule -1

Special Use - DC Coil NEM Labeled - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled with DC Coil ➊ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC 00 1/3 1 1-1/2 1-1/2 2 2 1 0 0 1 2 3 3 5 5 1 0 1 2 3 7-1/2 7-1/2 10 10 1 0 2 3 7-1/2 10 15 25 25 1 0 Catalog Number Price CN7-12E-10-24E ➎ 242 CN7-12C-10-200 CN7-16E-10-24E ➎ 267 CN7-16C-10-225 CN7-37E-10-24E ➎ 414 CN7-37C-10-372 CN7-43E-10-24E ➎ 475 CN7-43C-10-432 3 7-1/2 15 25 30 50 50 2 1 CN7-85D-10-612 CN7 NEM labeled contactor (C) CN 4 ~ ~ 40 50 100 100 1 1 CN6-180-L22- ➍ 2004 CN6-180-EI-11- ➌➍ 2290 5 ~ ~ 75 100 200 200 1 1 CN6-300-EI-11- ➌➍ 2950 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See page 62 for C(N)7 coils and pages 106-107 for C(N)6 coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See pages 52-53 (CN7) and page 104 (C[N]6). vailable as open units or in NEM 1, 3R, 4, 4X and 12 enclosures. Contact your Sprecher + Schuh representative for enclosed pricing. Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 101 for ordering information. CN7 DC Coil Codes ➋ CN7-12C...43C CN7 DC Coil Codes with integrated Diode ➋ CN7-85D CN6 DC Coil Codes Conventional Coils ➋➍ CN6-180-L22 CN6 DC Coil Codes EI Electronic Coils ➋➍ CN6-180-EI...300-EI DC Coil Code DC Coil Code DC Coil Code DC Coil Code 24D 24V 24DD 24V 24D 24V 24D 24V 110D 110V 110DD 110V SSN9000 ➊ Refer to page 88 for CN7 dimensional information and page 127 for C(N)6 dimensions. ➋ Other voltages available, see page 62 for CN7 and pages 106-107 for CN6. Nonstandard coil voltages not listed here must be ordered and installed separately as renewal parts. ➌ -EI designates contactor with Electronic Interface coil. ➍ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see pages 121-122). ➎ CN7-12E..43E have an electronic 24VDC coil that is not interchangeable. Discount Schedule -1 49

SSN9000 CL7 Series CL7 Lighting Compact contactors for North merican lighting applications Sprecher + Schuh C7 and C6 contactors can be used to control a wide variety of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other non-motor (resistive) loads. Lamps can basically be divided into three categories: Tungsten Filament Lamps - General purpose incandescent - Special purpose incandescent - Infrared - Sodium Iodine Discharge Lamps (with Ballast) - Fluorescent lamps - Mercury vapor - High/low pressure sodium - Quartz - Halogen metal-vapor Mixed Light Lamps In application Electrically held contactors Electrically held contactors are available for use where the control signal is activated by a timer or other maintained electrical signal. The coil is energized as long as the contactor is closed. This design is well suited for applications where lights are operated frequently or where the control panel is in a remote location. The tungsten filaments of incandescent lamps have a very low ohmic resistance when cold. s a result, the closing current is very high but also very short. The closing current of discharge lamps (lighting with ballast) is highly inductive (due to series-connected transformers or chokes), and its duration depends on the lamp type. Mechanically held contactors In general, North mericans refer to Lighting ratings in amperes without distinction between incandescent or ballast type of load. The lighting contactor selection table provided on the following page is for North merican use, so ratings are selected for mixed lamp loads which account for the higher incandescent inrush. Mechanically held contactors are available for applications where quiet operation or critical lighting is required, i.e., institutions, hospitals and residential/commercial areas. fter the contactor closes, the voltage is disconnected from the operating coil and the contactor is held closed by the mechanical latch. Built-in clearing interlocks allow control from either a momentary or maintained pilot device for the separate pull-in and release functions. Europeans usually separate the values for incandescent from discharge (ballast) lighting. Both values are provided in the technical section of our general catalog and may be more appropriate for those applying by CE standards. 50

Special Use - C Coil Lighting Series CL7 & CVL7 Lighting with C Coil Continuous Standard Electrically Held Mechanically Held ➊ mpere Number uxiliary Open Open Rating of Poles Contacts Type Type ❹ NO NC Catalog Number Price Catalog Number Price 20 4 0 0 CL7-20-M40-195 CVL7-20-M40- -L10 379 30 4 0 0 CL7-30-M40-288 CVL7-30-M40- -L10 427 60 4 0 0 CL7-60-M40-489 CVL7-60-M40- -L10 600 100 3 1 1 C6-110-11-750 ~ ~ 150 3 1 1 C6-180-11-1608 ~ ~ 200 3 1 1 C6-210-E1-11- 1917 ~ ~ Larger sizes available. Contact your Sprecher + Schuh representative. Description The CL7 electrically held contactors and CVL7 mechanical held contactors are cul rated and labeled for tungsten and ballast lighting duty applications at 20, 30, and 60 amperes respectively. CL7 C(L)7 Coil Codes ➋ C Coil Code 50 Hz 60 Hz 24Z 24V 24V 120 110V 120V 220W ~ 208V-240V 240 220V 240V 380 380V-400V 480V 480 440V 480V 600 550V 600V C6 Coil Codes ➋ C6-110 180 C Coil Code 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 240B 220-230V 260V 380 380-400V 440V 480 415V 480V 575 500V 575V The C6 contactors shown are selections based on available technical data. These C6 units do not bear a cul rating for use as a lighting contactor. C6 EI-Coil Codes ➌➋ C6-210-EI C Coil Code 50 Hz 60 Hz 120 110-130V 110-130V 220W 208-277V 208-277V 380 380-400V 380-400V Operation of Mechanically Held with ON-OFF Pushbutton Catalog number CVL7 consists of a CL7 contactor with CV7-11 mechanical latch. Depressing the ON button energizes the L coil and the contactor closes. The mechanical latch locks the contactor in the closed position. The L coil is then de-energized by the coil, clearing contact UL (Terminals 65-66) to remove voltage. Depressing the OFF button energizes the UL coil, and the mechanical latch releases the contactor. The UL coil is immediately de-energized by the coil clearing contact L (Terminals 13-14) to remove voltage. The contactor is now open. SSN9000 ➊ The N.O. auxiliary on the mechanical latch is used by the control circuit and is not available to the customer for other uses. ➋ Other voltages available, see page 61. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➌ -EI designates contactor with Electronic Interface coil. ➍ Engineering practice permits 2.5 x I e to be applied to a contactor when 3 poles are connected in parallel for single phase discharge lamp (ballast lighting) applications. Example: CL7-20-M40- Lighting plus a C7-P-B23 Paralleling Link can be used on a 50 ballast load. pplying parallel conductors to incandescent lamp loads does NOT result in a greater permissible load. Paralleling Links can be found in the ccessories section. Discount Schedule -1 51