I N S T R U C T I O N D A T A

Similar documents
TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

TC3301. User's Manual

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

TC3005(LED/ELED/LASER) User's Manual

Miniature Synchronous/Asynchronous Fiber Optic Modems

Synchronous Fiber Optic Modem

FOM-9010, FOM-9011 and FOM-9012

E3/DS3 Fibre Extender

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

INSTRUCTION MANUAL MODEL 2710 SUBCARRIER DEMODULATOR

VersiVision. FVTM2BBxA / FVRM2BBxA 2-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA 2-CHANNELS BI-DIRECTIONAL AUDIO

FIM-108 MATRIX FIBER INTERFACE INSTRUCTION MANUAL

MultiMode FOMs -ST and -SMA

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

VersiVision. FVTMHA0xA / FVRMHA0xA 16-CHANNEL DIGITALLY ENCODED VIDEO 1-CHANNEL BI-DIRECTIONAL DATA MULTIPLEXER USER S MANUAL.

Model /29S RF Splitter

TC1630. T1/E1 FIBER OPTIC MODEM User's Manual

INSTRUCTION MANUAL FOR MODEL IOC534 LOW LATENCY FIBER OPTIC TRANSMIT / RECEIVE MODULE

SPECIAL SPECIFICATION :1 Video (De) Mux with Data Channel

Analog HD video over fiber converters for smart HD CCTV

Instruction Manual Model # Block Upconverter

Single mode 9/125µm, duplex

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

Instruction Manual Model BlockUpconverter

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

USER MANUAL. MODEL 460RC Rack-Mounted G.703 Coax to Twisted Pair Adapters (BALUNs)

INSTRUCTION MANUAL. FiberSaver Series, FS-6000, FS-12000, FS-18000

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

Perle Fast Ethernet Media Converters

DIGITAL SWITCHERS 2100 SERIES

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Model 5240 Digital to Analog Key Converter Data Pack

Features. CPU Version. Non-CPU Version

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Fiber Optic Transmission Systems

One channel video link With duplex data and contact closure

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

SPECIAL SPECIFICATION 6735 Video Optical Transceiver

Instruction Manual.... light years ahead. S739DV & S7739DV Video and Up-the-Coax Control Systems

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

FiberLink 3500 Series Transceivers

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Perle Fast Ethernet Media Converters

FiberLink 3350 Series

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

USER MANUAL MODEL 2701/B, C, D. G.703/G.704 NTU with EIA-530, V.35, X.21 Interfaces SALES OFFICE (301) TECHNICAL SUPPORT (301)

MultiView T4 / T5 Transmitter

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Multicom Optical Return Path Receiver MUL HRPR 4B

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Product Operation Manual

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

FLM-2. 6/12 PORT LOCAL MULTIPLEXER Installation and Operation Manual. Notice

VNS2200 Amplifier & Controller Installation Guide

Covid HDBase-T Receiver for HDMI with Built in Audio de-embedding, IR, and RS232 control pass through

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

User Manual HDMI-EXT-501CO. HDMI Extender over Single Coax with Bi-directional IR 7.1 CH AUDIO. rev: Made in Taiwan

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Adder 882i Intercom/Data Multiplexer

HDMI 2.0 EXTENDER OVER CATX OR FIBER

PHOX TM. Camera Link Fiber Extender. Base Configuration KEY FEATURE APPLICATIONS PHOX-BM PHOX-BL-10/20/40/50

Fibre Optic Modem ODW-622

MULTIDYNE INNOVATIONS IN TELEVISION TESTING & DISTRIBUTION DIGITAL VIDEO, AUDIO & DATA FIBER OPTIC MULTIPLEXER TRANSPORT SYSTEM

3G fiber. TL7075/76 Optical 3Gbit/s Link solution with full duplex Communication Channel. TL Features. TL Features

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

SilverBULLET 3G Series

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

AES Channel Digital/Analog Audio Switcher/DA/Digital to Analog Converter

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

GE Interlogix Fiber Options S700V & S702V. Instruction Manual FIBER-OPTIC VIDEO TRANSMISSION SYSTEM

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Power Injector 1520 Series

Video Digital Optical Converter

Noise Detector ND-1 Operating Manual

32 Channel CPCI Board User Manual

ODW-621. RS-232 Point-to-point applications

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

FiberLink 7142 Series

Telesto Private Wire Modem Manual

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

MICROSENS. Fast Ethernet Switch Modul 4x 10/100Base-TX, 1x 100Base-FX. Description. Features

CLT-353R & CLT-353L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.1, 4/19/2013 preliminary

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

Instruction Manual Model Up/Downconverter

Async/Sync Fiber Optic Multiplexor

opengear OPG-1L 50 MHz-2.3 GHz

IF and L-Band Fiber Optic Links. Performance Highlights

Ethernet Media Converters

Six-Channel TDM Multiplexers for 3G, HD, SDI, and ASI. Installation and Operations. Manual

Transcription:

I N S T R U C T I O N D A T A RFL (C37.94) Fiber Service Unit Single Mode 108015-1 RS-449 108015-2 V.35 108015-3 G.703 108015-4 X.21 108015-5 E1 Multimode 107460-1 RS-449 107460-2 V.35 107460-3 G.703 107460-4 X.21 107460-5 E1 Multi and Single mode mounted in 1U chassis 107460-1-1 RS-449 (Multimode) 107460-1-2 RS-449 (Single Mode) 107460-2-2 V.35 (Single Mode) 107460-3-1 G.703 (Multimode) 107460-5-1 E1 (Multimode) RFL FSU 107460-1 R X DATA SYNC YEL PWR RS - 449 Boonton, New Jersey USA Figure 1. Typical RFL Fiber Service Unit, Front Panel view DESCRIPTION The RFL Fiber Service Unit (FSU) provides an interface between synchronous electrical signals and optical fiber. It can be used with the RFL 9300, RFL 9745, RFL IMUX 2000 or other types of multiplexers. It can also be used with any other C37.94 compliant, end device. There are a total of five varieties of FSUs using both single and multimode fiber heads. They use RS-449, V.35, G.703, X.21 and E1 as inputs and outputs on the non-fiber side of the connection. Note that there is a modification allowing the unit to be mounted into a 1U Chassis. The FSU is a stand-alone device, which is essentially a translator to and from data sent using these five interface standards in accordance with the IEEE C37.94 fiber protocol. The G.703 is 64,000 bps only and thus it has N fixed at 1. The other four versions use a DIP switch to set the value of N. The characteristics of each of the five types of Fiber Service Units, is shown in Tables 1, 2 and 3. Mounting dimensions are shown in Figure 12, except for the 1U version of the unit which is shown in Figure 6 and 9. May 20, 2013 1 (973) 334-3100

Table 1. Fiber Service Unit General Information Assy. Num. Multimode Assy. Num. Single Mode Interface Type 107460-1 107460-1-1 107460-2 - 107460-3 107460-3-1 107460-4 107460-5 107460-5-1 108015-1 107460-1-2 108015-2 107460-2-2 108015-3 - 108015-4 108015-5 - RS-449 RS-449 V.35 V.35 G.703 G.703 X.21 E1 E1 Interface Cable Connector 37-pin female 37-pin female 37-pin female 37-pin female 15-pin female 15-pin female 15-pin female 15-pin female or two BNCs 15-pin female or two BNCs Pinouts See Table 7 See Table 7 See Table 7 See Table 7 See Table 8 See Table 8 See Table 8 See Tables 9 & 10 See Tables 9 & 10 Table 2. Multimode Fiber Service Unit Characteristics at 25º C Assembly Number 107460-1 Type Wavelength/ Mode Connector Type Receiver Sensitivity (average) Power (average) Typical Distance (3dB margin) 107460-1-1 107460-2 107460-3 107460-3-1 107460-4 LED Emitter/ Detector 830 (+/- 40 nm) multimode ST -11 dbm to -32dBm -11dBm to -23dBm into 50μm fiber -11dBm to -19dBm into 62.5μm fiber Up to 2km (1.2 mi.) 107460-5 107460-5-1 Table 3. Single mode Fiber Service Unit Characteristics at 25º C Assembly Number 108015-1 Type Wavelength/ Mode Connector Type Receiver Sensitivity (average) Power (average) Typical Distance (3dB margin) 107460-1-2 107460-2-2 108015-2 108015-3 LED Emitter/ Detector 1300 (+/- 30 nm) single mode ST -35dBm -20dBm to -22dBm into 9μm fiber Up to 10km (6.2mi.) 108015-4 108015-5 May 20, 2013 2 (973) 334-3100

SPECIFICATIONS As of the date this Instruction Data Sheet was published, the following specifications apply to the RFL Fiber Service Unit. Because all RFL products undergo constant refinement and improvement, these specifications are subject to change without notice. IEEE Standard: C37.94 for N times 64 kilobit per second optical fiber interfaces between teleprotection and multiplexer equipment. Signal Connector Type: 15-pin male type D subminiature for G.703 and X.21 37-pin male type D subminiature for RS-449 and V.35 15-pin male type D subminiature or dual BNCs for E1 Data Rate: Programmable from 64 kb/s to 768 kb/s in accordance with Table 6. Input Power Requirements: 38 to 150 Vdc @ 3Watts Operating Temperature: -30 O C to +60 O C (-22 O F to +140 O F) Relative Humidity: 95 percent @ 40 o C, non-condensing. Dimensions for standard units: Width: 5.13 inches (13 cm) Height: 1.77 inches (4.5 cm) Depth: 8.51 inches (21.6 cm) Mounting Dimensions: In accordance with Figure 12 except for 1U chassis mounting. May 20, 2013 3 (973) 334-3100

INSTALLATION Installation involves mounting the FSU module in its desired location, connecting all signal, coaxial and power cables, and programming the module data rate and other configuration settings. Note 1: Instructions for the 107460-1 thru -4 FSU units also apply to the following units. 108015-1 thru -4, 107460-1-1, 107460-1-2, 107460-2-2 and 107460-3-1 Note 2: Instructions for the 107460-5 FSU also apply to the 108015-5 and 107460-5-1 units. To install the module, proceed as follows: 1. Carefully inspect the module for any signs of shipping damage. If you suspect damage to the module, immediately call RFL Customer Service at the number given at the bottom of this page. 2. Check the assembly number on the front panel of the module to make sure the unit is compatible with your interface requirement as shown in Table 1. 3. Use Table 7 as a wiring guide for the D subminiature connector if your interface is RS-449 or V.35. Use Table 8 as a wiring guide for the D subminiature connector if your interface is X.21 or G.703. Use Table 9 as a wiring guide for the D subminiature connector if your interface is 120 ohm E1. Use Table 10 as a wiring guide for the BNC connectors if your interface is 75 ohm E1. When fastening the D subminiature connector, make sure that the screws on both ends of the mating connector are tightened to secure the connector to the FSU front panel. NOTE ALL CABLING TO AND FROM THE FIBER SERVICE UNIT INTERFACE CONNECTOR MUST UTILIZE SHIELDED TWISTED PAIR OR COAXIAL CABLE TO MINIMIZE CROSSTALK AND INTERFERENCE FROM EXTERNAL SOURCES. CAUTION BEFORE ATTEMPTING TO MAKE POWER CONNECTIONS TO THE FIBER SERVICE UNIT, MAKE SURE THAT YOUR POWER SOURCE IS COMPATIBLE WITH THE FSU. IF THE IMPROPER VOLTAGE IS CONNECTED TO THE FSU, COMPONENT DAMAGE MAY RESULT. A suitably rated power disconnect device and over current protection device (e.g. fuse or circuit breaker) must be installed between the station battery supply and the FSU power input. The over current protective device should be rated at 0.5 to 1.5 Amps. 4. Connect input power to the following terminals on the rear-panel terminal block connector TB1, as shown in Figure 5, see Figure 6 and 9 for 1U chassis installation. Station battery positive TB1-1 Station battery negative TB1-2 Ground TB1-3 5. Fiber optic cables with type ST series bayonet fiber optic connectors must be connected to the fiber optic heads on the front panel of the FSU module and to the far end chassis. When connecting fiber optic cables, make sure the connectors are properly aligned before tightening, and then fully tighten them. This will help minimize losses in the connector. May 20, 2013 4 (973) 334-3100

6. For 107460-1 to -5, select the FSU data rate using DIP switches SW1-1 through SW1-4 in accordance with Table 6. The FSU data rate must be set to the same data rate as the unit at the other end of the fiber. The settings of SW1-1 through SW1-4 are ignored by the (107460-3) G.703 module since its data rate is fixed at 64 kb/s. For an RFL 9745 the data rate is 64 kb/s. For an RFL 9300 the data rate is 64 kb/s. 7a. For 107460-1, -2, -4, select a normal or inverted transmit data clock by using DIP switch SW1-5. Place SW1-5 to the DOWN position to select normal transmit data clock. Place SW1-5 to the UP position to select inverted transmit data clock. For 107460-3, set SW1-5 to the UP position. 7b. For 107460-5, enable or disable CRC4 generation by using DIP switch SW1-5. Place SW1-5 to the DOWN position to enable CRC4. Place SW1-5 to the UP position to disable CRC4. 8a. For 107460-1, -2 and -4, select a normal or inverted receive data clock by using DIP switch SW1-6. Place SW1-6 to the DOWN position to select normal receive data clock. Place SW1-6 to the UP position to select inverted receive data clock. For 107460-3, set SW1-6 to the DOWN position. 8b. For 107460-5, select AMI or HDB3 encoding by using DIP switch SW1-6. Place SW1-6 to the DOWN position to select HDB3 encoding. Place SW1-6 to the UP position to select AMI encoding. 9a. For 107460-1, -2 & -4, select a normal or inverted data by using DIP switch SW1-7. This switch is ignored by 107460-3. Place SW1-7 to the DOWN position to select inverted data. Place SW1-7 to the UP position to select normal data. 9b. For 107460-5, enable or disable Fiber Loopback by using DIP switch SW1-7. Place SW1-7 to the DOWN position to enable Fiber Loopback. Place SW1-7 to the UP position to disable Fiber Loopback. 10a. For 107460-3, enable or disable octet timing on the G.703 module by using DIP switch SW1-8. This switch is ignored by 107460-1, -2 and -4. Place SW1-8 to the UP position to enable octet timing. Place SW1-8 to the DOWN position to disable octet timing. 10b. For 107460-5, enable or disable E1 Loopback by using DIP switch SW1-8. Place SW1-8 to the UP position to enable octet timing. Place SW1-8 to the DOWN position to disable octet timing. 11. For 107460-5, set switches and jumpers on Board B in accordance with Table 5. 12. The FSU is now installed and is ready to be placed in service. For more information consult the Instruction Manual for the RFL 9745, RFL 9300 or the RFL IMUX 2000 as applicable. May 20, 2013 5 (973) 334-3100

Motherboard Short haul fiber interface module Up To 2km for multimode Up to 10km for single mode Type ST bayonet connector ( 4 places) Fiber Service Unit Front panel of 9300 107500 Tx Rx Tx fiber Rx fiber Rx Tx 107460-X Or 108015-X RS-449 V.35 G.703 X.21 or E1 as applicable RFL 9300 Chassis (Top View) Rear panel of 9300 38 to 150 Vdc Input Power 15-pin, 37-pin, or BNC connectors as applicable Figure 2. Connecting the FSU to an RFL 9300 Note: The FSU unit is orientated differently in a 1U chassis; the connections are the same (See Fig. 6 and 9) Short haul fiber interface module Up To 2km for multimode Up to 10km for single mode Type ST bayonet connector ( 4 places) Fiber Service Unit Front panel of 9745 107310 Tx Rx Tx fiber Rx fiber Rx Tx 107460-X Or 108015-X RS-449 V.35 G.703 X.21 or E1 as applicable RFL 9745 Chassis (Top View) Rear panel of 9745 38 to 150 Vdc Input Power 15-pin, 37-pin, or BNC connectors as applicable Figure 3. Connecting the FSU to an RFL 9745 Note: The FSU unit is orientated differently in a 1U chassis; the connections are the same (See Fig. 6 and 9) May 20, 2013 6 (973) 334-3100

RS-449 V.35 G.703 X.21 or E1 as applicable Fiber Service Unit Up To 2km for multimode Up to 10km for single mode Type ST bayonet connector ( 4 places) Non-C37.94 compliant multiplexer 107460-X Or 108015-X Tx Rx Tx fiber Rx fiber Rx Tx 9745, 9300 or any other C37.94 compliant device 38 to 150Vdc Input Power 15-pin, 37-pin, or BNC connectors as applicable Figure 4. Connecting the FSU to a non-c37.94 compliant multiplexer Note: The FSU unit is orientated differently in a 1U chassis; the connections are the same (See Fig. 6 and 9) May 20, 2013 7 (973) 334-3100

CONTROLS AND INDICATORS (107460-1 to 107460-4) The RFL FSU (107460-1 to 107460-4) has user controls and indicators as shown in Figures 5 and 7. Figure 5 shows the location of all controls, indicators and connectors on the front and rear panels of the FSU module. Figure 7 shows the location of controls and indicators on ECB number 107463. The function of all controls and indicators are described in Table 4. UP DOWN SW1 DS1 DS3 DS5 DS2 a. Front Panel U8 RX RS - 449 RFL FSU 107460-1 DATA SYNC YEL PWR DS4 Boonton, New Jersey USA SW1-8 SW1-1 P1 or P2 +SB -SB b. Rear Panel See Figure 6 for 1U chassis installation 38-150 VDC CAUTION 0.25 A 20 W MAX TB1 TB1-1 Ground Lug TB1-3 Figure 5. Fiber Service Unit, front and rear panel controls and indicators (107460-1 to 107460-4) May 20, 2013 8 (973) 334-3100

WT WT WT WT WT CONTROLS AND INDICATORS (107460-1-1, 107460-1-2, 107460-2-2, 107460-3-1) The RFL FSU units 107460-1-1, 107460-1-2, 107460-3-1 are identical to the previous assemblies, however they have been modified to fit into a 1U Chassis. As shown below, the unit mounts from the rear with all controls, indicators and connections on the rear panel. Figure 7 shows the location of controls and indicators on the ECB number 107463. The function of all controls and indicators are described in Table 4. 19.00 REF. 18.312 REF. RFL ELECTRONICS BOONTON, NEW JERSEY,USA 1.718 1.25 REF. REF. UP 8 Front View of 107460-1-1, 107460-2-2, 107470-1-2, 107460-3-1 mounted in a 1U Chassis.234 REF. U8 DOWN DS1 DS5 DS2 DS3 DS4 8 1 RX 8 1 RX SW1 SW1 G.703 RS 449 or V.35 Ass'y 107460-3-1 Ass'y 107460-1-1, 107460-1-2, 107460-2-2 P2 P1 All other designations as Ass'y 107460-3-1 Rear View of 107460-1-1, 107470-1-2, 107460-2-2, 107460-3-1 mounted in a 1U Chassis +SB GROUND -SB GRN BLK RED GRN BLK RED DATA SYNC YEL PWR DATA SYNC YEL PWR 6 5 4 3 2 1 6 5 4 3 2 1 Wiring Diagram for Two FSU's mounted in a 1U Chassis RED BLK GRN +SB -SB Figure 6. Fiber Service Unit, mounted in a 1U Chassis (107460-1-1, 107460-1-2, 107460-1-3) May 20, 2013 9 (973) 334-3100

U8 DS4 DS5 DS1 DS2 DS3 SW1 TB1 F1 Figure 7. Fiber Service Unit ECB No. 107463 (Board A), controls and indicators (107460-1 to 107460-4, 107460-1-1, 107460-1-2, 107460-3-1) May 20, 2013 10 (973) 334-3100

Table 4. Controls and indicators, Fiber Service Unit (107460-1 to 107460-4, 107460-1-1,107460-1-2, 107460-2-2, 107460-3-1) Location Reference Designation Function Front Panel U8 Fiber optic detector SW1 DS4 DS5 DS1 DS2 DS3 P1 or P2 8-position DIP switch used to set FSU operating parameters as follows: SW1-1 through SW1-4: Selects Data Rate in accordance with Table 6. SW1-5: For 107460-1, -2 and -4, Selects NORMAL or INVERTED Xmit Data Clock as follows: Down = Normal Clock Up = Inverted Clock For 107460-3, SW1-5 must be UP SW1-6: For 107460-1, -2 and -4 selects NORMAL or INVERTED Receive Data Clock as follows: Down = Normal Clock Up = Inverted Clock For 107460-3, SW1-6 must be DOWN SW1-7: On 107460-1, -2 and 4 selects normal or inverted data as follows Down = Inverted Data Up = Normal Data SW1-8: (This switch applies to G.703 only and is ignored by all other FSU modules) Selects octet timing as follows: Up = Octet Timing Enabled Down = Octet Timing Disabled Fiber optic emitter DATA LED (green), illuminated when data is present on the electrical interface. SYNC LED (green), illuminated when the optical signal is in sync. YEL LED (yellow), Yellow Alarm Indication, illuminated when the remote fiber receiver has failed and the remote transmitter is sending a yellow code by the local fiber receive channel. PWR LED (green), illuminated when power is ON. Connector Rear Panel TB1 Power connector Ground Lug Ground lug On ECB No. 107463 Board A F1 FSU power supply fuse (see note below) Note: F1 is a 0.25 Amp, 250 Volt SLO-BLO, 5x20 mm fuse. Littlefuse part number is: 239.250 BUS part number is: GMD-.25A May 20, 2013 11 (973) 334-3100

CONTROLS AND INDICATORS (107460-5) The RFL FSU (107460-5) has user controls and indicators as shown in Figures 8, 10 and 11. Figure 8 shows the location of all controls, indicators and connectors on the front and rear panels of the FSU module. Figures 10 and 11 show the location of controls and indicators on Board A and Board B. The function of all controls and indicators are described in Table 5. UP DOWN SW1-8 DS7 DS1 DS3 SW1-1 DS6 DS2 DS4 RFL FSU E1 107460-5 a. Front Panel U8 RX E1 E1 D Y FO D FO Y PWR 75 OHM 75 OHM RX Boonton, New Jersey USA J206 SW1 J204 J207 +SB -SB b. Rear Panel See Figure 9 for 1U chassis installation 38 - CAUTIO 150 VDC 0.25 A N 20 W MAX TB1 TB1-3 TB1-1 Ground Lug Figure 8. Fiber Service Unit, front and rear panel controls and indicators (107460-5) May 20, 2013 12 (973) 334-3100

WT WT R WT WT CONTROLS AND INDICATORS (107460-5-1) The RFL FSU (107460-5-1) is identical to the 107460-5 unit shown on the previous page; however it has been modified to fit into a 1U Chassis. As shown below, the unit mounts from the rear with all controls, indicators and connections on the rear panel. Figure 10 and 11 show the location of controls and indicators on Board A and Board B. The function of all controls and indicators are described in Table 5. 19.00 REF. 18.312 REF. RFL ELECTRONICS BOONTON, INC. NEW JERSEY, USA FS 2000 U CCM 1.718 1.25 REF. REF. Front View of 107460-5-1 mounted in a 1U Chassis 8 UP.234 REF. DOWN DS7 DS6 DS1 DS2 DS3 DS4 U8 RX 8 1 75 OHM E1D SW1 120 OHM 75 OHM RX 107460-5-1 J206 J204 J207 RX 8 1 75 OHM SW1 120 OHM E1 D E1 Y FO D FO Y PW 75 OHM RX 107460-5- 1 Rear View of 107460-5-1 mounted in a 1U Chassis +SB -SB GROUND GRN BLK RED GRN BLK RED E1Y FOD FOY PWR 6 5 4 3 2 1 6 5 4 3 2 1 Wiring Diagram for Two FSU's mounted in a 1U Chassis RED BLK GRN Figure 9. Fiber Service Unit, mounted in a 1U Chassis (107460-5-1) May 20, 2013 13 (973) 334-3100 +SB -SB

U8 DS4 DS7 DS6 DS1 DS2 DS3 SW1 TB1 F1 Figure 10. Fiber Service Unit ECB No. 107463-5 (Board A), controls and indicators (107460-5, 107460-5-1) May 20, 2013 14 (973) 334-3100

J206 J204 RX J207 J203 U G G U 12 0 J205 SW201 75 ON 1 2 3 4 5 6 SW203 Figure 11. Fiber Service Unit ECB No. 107463-5 Board B (107460-5, 107460-5-1) May 20, 2013 15 (973) 334-3100

Location Table 5. Controls and indicators, Fiber Service Unit (107460-5 and 107460-5-1) Reference Designation Function Front Panel U8 Fiber optic detector SW1 8-position DIP switch used to set FSU operating parameters as follows: SW1-1 through SW1-4: Selects Data Rate in accordance with Table 6. SW1-5: Selects CRC generation as follows: Down = Generate CRC4 Up = Do not generate CRC4 SW1-6: Selects AMI or HDB3 encoding as follows: Down = Selects HDB3 encoding Up = Selects AMI encoding SW1-7: Enables or disables fiber Loopback as follows: Up = Loopback enabled Down = Loopback disabled SW1-8: Enables or disables E1Loopback as follows: Up = Loopback Enabled Down = Loopback Disabled DS1 DS2 DS3 DS4 DS6 DS7 J204 J206 J207 FO D LED (green) Lights green when fiber optic data is being received. FO Y LED (yellow) Lights yellow when remote fiber unit is not receiving data. PWR LED (green) Lights green when power is applied to input terminals. Fiber Optic Emitter E1 Y LED (yellow) Lights yellow when the remote E1 unit is not receiving data. E1 D LED (green) Lights green when E1 data is being received. DB-15 120 ohm E1 Connector 75 ohm E1 Connector 75 ohm E1 RX Connector Rear Panel TB1 Input power connector (Connect +dc supply to +SB, connect dc supply to SB) Ground Lug Ground lug (Connect to earth ground) On ECB No. 107463-5 Board A F1 FSU power supply fuse (see note below) Note: F1 is a 0.25 Amp, 250 Volt SLO-BLO, 5x20 mm fuse. Littlefuse part number is: 239.250 BUS part number is: GMD-.25A May 20, 2013 16 (973) 334-3100

Location Table 5. continued - Controls and indicators, Fiber Service Unit (107460-5 and 107460-5-1) Reference Designation Function On ECB No. 107463-5 Board B J203, J205 Used to ground the outer conductor of the BNC connectors when necessary. Both jumpers should be set to U when using the DB-15 E1 port. J203 is set to G and J205 is set to U when using the BNC E1 ports J204 120 ohm E1 port (DB-15 male connector) Refer to Table 8 for interface connections J206 75 ohm E1 port (BNC connector) J207 75 ohm E1 RX port (BNC connector) SW201 Selects impedance of E1 port as follows: Set to 75 when using 75-ohm BNC ports Set to 120 when using 120-ohm DB-15 port SW203 Used to set E1 operating parameters as follows: SW203-1 Selects Timing Mode ON = Thru timing OFF = Internal timing SW203-2 For factory use only (Switch must be set to ON position) SW203-3 Selects Normal operation or Transmit all ones, on E1 port. ON = Normal operation (default setting) OFF = Transmit all ones SW203-4 Enables or disables jitter attenuator ON = Disable jitter attenuator OFF = Enable jitter attenuator (default setting) SW203-5 Jitter attenuator selection ON = Receiver (default setting) OFF = Transmitter SW203-6 Selects inverted data ON = Inverted data OFF = Normal operation (default setting) May 20, 2013 17 (973) 334-3100

Table 6. Data Rate Selection Data Rate (KB/s) N SW1-1 SW1-2 SW1-3 SW1-4 64 1 Down Down Down Down 128 2 Down Down Up Up 192 3 Down Down Up Down 256 4 Down Up Down Up 320 5 Down Up Down Down 384 6 Down Up Up Up 448 7 Down Up Up Down 512 8 Up Down Down Up 576 9 Up Down Down Down 640 10 Up Down Up Up 704 11 Up Down Up Down 768 12 Up Up Down Up Note 1. G.703 is 64 kb/s only and has N fixed at 1. Note 2. Down = OPEN, Up = CLOSED. Table 7. RS-449 and V.35 Interface Connections Table 8. X.21 and G.703 Interface Connections RS-449 and V.35 X.21 and G.703 Signal Pin Number Signal Pin Number RD(A) 6 RXD_A 4 RD(B) 24 RXD_B 11 RT(A) 8 RT(A5) 6 RT(B) 26 RT(B5) 13 ST(A) 5 D_A 2 ST(B) 23 D_B 9 SD(A) 4 Ground 1, 8 SD(B) 22 Ground 1, 19 Table 9. E1 120 Ohm Interface Connections Table 10. E1 75 Ohm Interface Connections Signal Pin Number Signal Connector Data + 9 J206 Data - 1 RX J205 RX Data + 11 RX Data - 3 Chassis 7 May 20, 2013 18 (973) 334-3100

RFL FSU 107460-1 R X RS - 449 DATA SYNC YEL PWR 1.77 in. (4.5 cm) Boonton, New Jersey USA a. Fiber Service Unit front view 5.13 in. (13 cm) 0.59 in. (1.5 cm) 0.31 in. ( 0.80 cm) diameter typical b. Fiber Service Unit top view 7.34 in. (18.54 cm) 4.13 in. (10.49 cm) 8.51 in. (21.61 cm) 4.73 in. (12 cm) Figure 12. Mounting Dimensions, RFL 93 FSU Fiber Service Unit (107460-1 to 107460-5 and 108015-1 to 108015-5) May 20, 2013 19 (973) 334-3100

Notice The information in this publication is proprietary and confidential to No part of this publication may be reproduced or transmitted, in any form or by any means (electronic, mechanical, photocopy, recording, or otherwise), or stored in any retrieval system of any nature, unless written permission is given by This publication has been compiled and checked for accuracy. The information in this publication does not constitute a warranty of performance. reserves the right to revise this publication and make changes to its contents from time to time. We assume no liability for losses incurred as a result of out-of-date or incorrect information contained in this publication. Disposal When disposing of the equipment, it should be done in strict accordance with all local and national regulations for the disposal of electrical and electronic equipment. The printed circuit boards should be separated for recycling. Email: sales@rflelect.com for information on other innovative RFL product 353 Powerville Road Boonton Twp., NJ 07005-9151 USA Tel: 973.334.3100 Fax: 973.334.3863 Email: sales@rflelect.com www.rflelect.com Publication No. ID C37.94FSU Printed in U.S.A. Revised May 20, 2013 May 20, 2013 20 (973) 334-3100