General Specifications

Similar documents
General Specifications

Wall-/Pipe-Mount Level Indicator

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Lt DELTA USA, Inc

ABB MEASUREMENT & ANALYTICS DATA SHEET. AZ100 series Zirconia oxygen analyzer for small boiler applications

Modular Lube Lubrication Systems System Controls

Mechanical flow switch for On/Off control

SCALE & WEIGHT DISPLAYS

General Specifications

AP-40. AP-40 Series Features Industry s smallest-sensor head Ultra lightweight High-speed response Two-color LED digital pressure display

Single Point Flow Monitor SW118 SW119

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

LAUREL ELECTRONICS, INC.

Micro-DCI 53ML5100 Manual Loader

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Signet 2250 Hydrostatic Level Sensor

SPOOL PIECE ultrasonic FLOWMETER

PROPORTIONAL VALVES Sentronic plus

Dissolved Oxygen Transmitter

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Dissolved Oxygen Transmitter

Level Measurement silometer FMC 420, FMC 423

Process Transmitter RMA 422

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

MODEL: 40DPT. Digital Panel Meters 40 Series. [3] OPTIONS blank: none /Q: With options (specify the specification)

Hybrid Chart Recorder 250 mm (10")

TFR5 Room or outdoor temperature sensor. CombiTemp TM

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Installation and Setting up Instructions for the 990 Signal Conditioning Instrument

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

TELEDYNE HASTINGS INSTRUMENTS

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

How to Order. Flow rate (l/min) Applicable models PFA710, PFA750. Nil

SQM40/41 Actuators for air and gas dampers

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

EVENT INPUT/OUTPUT MODULE [PUME]

LONWORKS Fibre Optic Converter

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

1 Output 1 operation. 3 Pressure unit display. 4 Main display Large 4-character LCD display. 5 Sub-display Small 4-character LCD display.

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Micro-Machined Silicon Transducers

Filters for Power Lines (Low Leakage Current)

Solid-State Digital Timer

Pressure Sensor. PSAN Series. Compact Digital Pressure Sensors. Features Pressure Measurement Range (Negative, Standard, Compound)

Henkel Installation Handbook LINEGUARD 2001

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Model KBF 1020 Constant climate chambers with large temperature / humidity range

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Model KBF 115 Constant climate chambers with large temperature / humidity range

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Metric Series. PXM409 Differential Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-25 mbar to 0-70 bar

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Model Number Structure

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Safety Light Curtains

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Digital Flow Switch for Large Flow

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

ZN-PD-SA. Air Particle Sensor. Continuously monitor dust fallout and particles which detract from product quality. Ordering Information.

Magnecraft Power Relays

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Digital differential Pressure switch Model DPS Instruction manual

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

General Specifications

MAXX BOX. MX102/202 Series. MAXX Box

Rack mounted telephone- and leased line modem for industrial applications

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

RCA3 SOLENOID PILOT VALVES PENTAIR CLEAN AIR SYSTEMS

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

IPC-DT/H20X(PC)T IPC-DT/M20V(PC)T, IPC-DT/L20S(PC)T, IPC-DT/H20X(PC)T. Option. Features. Ver.1.10

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

CATALOG NUMBER: HK-MX-VGA-X-Y Product Name

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

User s Manual Model WF100 Extension Cable for EXA100

Digital Gap Checker to 0.15 mm (Displayable/Settable range: 10 to 300) G type Rated distance range. Workpiece. Large gap. Workpiece.

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

Cylindrical Photoelectric Sensor CY-100 SERIES

Transcription:

General Specifications GS 12E01A06-01E Model TB750G Right Angle Scattered Light Turbidimeter General There are increasing demands for good quality water for both industrial-use and drinking water applications because of rapid industrial development and consumer demands for better quality of life. A large amount of the waste water from both applications has been drained or discharged into rivers, causing pollution to worsen year after year. This has caused serious social problems. Therefore, turbidimeters, conventionally used for the operation and control of water purification plants, are nowadays being required to measure the amount of matter suspended in various sorts of industrial waste water and to measure the turbidity of chemical processes. Since their sales began in 1959, Yokogawa s turbidimeters have been continuously developed and improved using various measurement principles suited for various applications. With its many achievements, Yokogawa has earned its customers confidence. Developed based on years of experience and applications in process fields, the TB750G Turbidity Measuring System using right angle light scattering method provides highly reliable measurement and improved maintainability which improve upon what previous models could offer. Features Highly reliable measurement with excellent linearity and repeatability Linearity: ±2% of reading or ±0.01 NTU, whichever is greater Repeatability: ±1% of reading or ±0.002 NTU, whichever is greater Display resolution: 0.001 NTU Easy-to-clean cell Compact, lightweight converter and detector User configurable measuring range Measuring range: 0-0.2 NTU to 0-100 NTU Measuring range switching (2 or 3 ranges) Enhanced self-diagnostic function as standard Light source failure, input element failure, calibration failure, various circuit failures, etc. Detector structure to remove sudden reading change caused by bubbles A wide range of measurement conditions Low flow rate: 0.05 to l/min High pressure: 500 kpa maximum Temperature: 0 to 50 C Detector can be connected for in-line analysis 2 analog outputs, 3 relay contact outputs, and 1 serial communication Many options available Ultrasonic transducer and oscillator for ultrasonic cleaning Various head tanks to accommodate application requirements Measurement method is based on US EPA 180.1. System Configuration Example: Typical system Analog output Serial communication output Range contact output input Power supply RS-422 or RS-232C TB750G Converter Sample water inlet Sample water Light source Sample water outlet TB750G Detector Light receiver Example: System with ultrasonic oscillator and zero turbidity filter Analog output Serial communication RS-422 or RS-232C output Range contact output input Power supply Sample water Tap water Head tank TB750G Converter for washing TB750G Detector F01.ai TUS400G should be purchased separately. TUS400G Ultrasonic Oscillator Sample water outlet Light source Sample water inlet Zero turbidity filter Zero sample Zero turbidity filter should be purchased separately. Light receiver F02.ai Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792 GS 12E01A06-01E Copyright Jun. 05 4th Edition Mar. 14

2 Standard Specifications 1. TB750G Right Angle Scattered Light Turbidimeter Measurement: Turbidity of finished water and water used in general processes Measurement method: Right angle light scattering method Measuring range: 0.000 to 100.0 NTU Display: 4 digit LCD (6 digits in message area), negative value indication enabled/disabled Unit: NTU Resolution: 0.001 NTU Turbidity standard: Formazin Analog output: Number of outputs: 2 Output signal: Analog output 1; 4 to ma DC, isolated Analog output 2; 4 to ma DC or 0 to ma DC selectable, isolated (Both analog outputs are not isolated.) Load resistance: 550Ω max. Output range: Configurable within the measuring range Minimum range; 0 to 0.2 NTU Maximum range; 0 to 100 NTU Minimum span; % or more of upper limit of the range or 0.2 NTU, whichever is greater. Note: When auto range switching is selected, lower limit of the range is 0 NTU. Range switching: Enabled/disabled in either analog output 1 or 2. Not available in both outputs. Manual (local) range/auto range/remote 2-range/remote 3-range switching selectable. Output signal in maintenance: Output hold enabled/disabled Hold output: Last measured value or fixed value (between 2.0 and 22.0 ma for 4 to ma DC output; between 0.0 and 22.0 ma for 0 to ma DC output) selectable Output signal in FAIL: Output hold enabled/disabled Hold output: Last measured value or fixed value (between 2.0 and 22.0 ma for 4 to ma DC output; between 0.0 and 22.0 ma for 0 to ma DC output) selectable Negative value indication: Enabled/disabled Serial communication: Number of outputs: 1 Communication signal: RS-422 or RS-232C, isolated Command: Requests of turbidity measurement, error information, and output range switching Communication data: Turbidity, status (measurement/maintenance/calibration, FAIL, high/low alarm, output range), error information Communication method: Start-stop synchronization, non-procedural Communication setting: 9600 bps, parity (even), stop bit 1 bit, data length 8 bit Distance: RS-422; 1000 m max. RS-232C; 10 m max. Cable: RS-422; Twisted pair cable with shield (AWG to 16) RS-232C; Cable with shield output: Type: Relay contact output Number of contacts: 3 Action: On/Off Function: S1, S2: High/low alarm or in-maintenance selectable FAIL: Failure Rating: 250 VAC, 2A, 125 VA max. (resistance load) or 30 VDC, 3A, 60 W max. (resistance load), Form C (NC/NO/COM, 3 terminals) status: S1, S2 FAIL Status LED NO NC LED NO NC In action ON Closed Open ON Open Closed Not in action OFF Open Closed OFF Closed Open Power OFF OFF Open Closed OFF Open Closed input: Type: Voltage-free contact input Number of contacts: 2 Function: Remote range switching On resistance: Input resistance 0Ω or less Off resistance: input resistance 100kΩ or greater status: Remote 2-range switching When Range Switching is Selected Range A Range B IN1-COM Open Closed Remote 3-range switching When Range Switching is Selected Range A Range B Range C IN1-COM Open Closed Open IN2-COM Open Open Closed Range contact output: Type: Relay contact output Number of contacts: 3 Action: On/Off Rating: 250 V AC, 2 A, 125 VA max. (resistance load) or 30 V DC, 3 A, 60 W max. (resistance load) status: When Fixed When Range Switching is Selected Range is Selected Range A Range B Range C RANGE A-COM Open Closed Open Open RANGE B-COM Open Open Closed Open RANGE C-COM Open Open Open Closed Calibration: Zero calibration: Zero water (filtered water with zero turbidity) Span calibration: Sensitivity calibration using check block or turbidity standard solutions 2-point calibration: Turbidity standard solutions Grab sample calibration: Zero point and sensitivity correction using grab sample Self-diagnostics: Light source failure, input element failure, calibration failure, AD circuit failure, memory failure, etc. Installation location: Indoor (Weather protection is required for outdoor installation) Ambient temperature: -5 to 50 C (Sample and tap water may need protection against freezing) Ambient humidity: 5 to 95%RH (non-condensing) Storage temperature: -30 to C Sample water conditions: Flow rate: 0.05 to l/min Temperature: 0 to 50 C All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Nov. 25, 14-03

3 Pressure: 500 kpa max. Mounting: Pipe, wall, rack or panel mounting Piping connection (detector): Sample water inlet: (optional) Sample water outlet: (optional) port: Rc1 or 1NPT (optional) Cable inlet port (detector and converter): DIN Pg 13.5 cable gland Cable OD.: 6 to 12 mm Dimensions: Detector: 378W x 174H x 265D mm Converter: W x H x 142D mm Material (main): Detector: Aluminum alloy casting, modified PPE resin Wetted parts: Modified PPE resin, glass, fluoric rubber, silicon rubber, SUS 316 Converter: Aluminum alloy casting, Polycarbonate resin Construction: JIS C 09, IP65 Water-tight Finish: Detector, converter: Baked polyurethane resin coating (standard) Baked epoxy resin coating (optional) Color: Detector: Spring Black (Munsell 3.3PB2.5/0.5 or equivalent), Mint green (Munsell 5.6BG3.3/2.9 or equivalent) Converter: Silver Gray (Munsell 3.2PB7.4/1.2 or equivalent) Weight: Detector: Approx. 5.8 kg Converter: Approx. 1.5 kg Power supply: 100 to 240 VAC -15%/+10%, 50/60 Hz Grounding: Class D grounding Grounding resistance of 100Ω or less Power consumption: Converter + Detector: 50 VA max. Regulatory Compliance EMC Regulatory Arrangement in Australia and New Zealand EN 55011 Class A, Group 1 Korea Electromagnetic Conformity Standard Class A 한국전자파적합성기준 Characteristics Standard performance (under normal operating conditions) Repeatability: ±1% of reading or ±0.002 NTU, whichever is greater Linearity: ±2% of reading or ±0.01 NTU, whichever is greater Response time: Within 2 minutes (90% response, sample water flow rate 3 l/min) Optional Specifications Head tank: Simple head tank Application: Turbidity is 10 NTU or less. To remove relatively large air bubbles. Sample water conditions: Flow rate: 1 to 10 l/min Turbidity: 2 to 10 NTU Pressurized head tank for low turbidity Application: Turbidity is 2 NTU or less. To remove air bubbles and to prevent them from occurring. Sample water conditions: Flow rate; 0.05 to 10 l/min Turbidity; 2 NTU or less Pressure; to 500 kpa Transducer for ultrasonic cleaning (TUS400G Ultrasonic Oscillator should be purchased separately.) Zero turbidity filter When measuring range is 2.0 NTU or greater: 1 μm When measuring range is below 2.0 NTU: 1 μm + 0.2 μm 2. TUS400G Ultrasonic Oscillator Combination device: Turbidity converter (TB750G) Special cable (3-conductor shielded cable) Cleaning method: Continuous ultrasonic emission (Frequency sweep method) Oscillation frequency: Approx. 1 to 0 khz (sweeping frequency: Approx. 160 to 250 khz) Output voltage: Approx. 40 to 80 V Power supply: 100/110/115/0/2/240 V AC ±10%, 50/60 Hz Power consumption: Approx. 30 VA Insulation resistance: Power supply-g: 100 MΩ or more / 500 V DC Output terminals-g: 100 MΩ or more / 500 V DC Withstand voltage: Power supply-g: 1000/1500 V AC for 1 min. Output terminals-c: Ambient temperature: 1000/1500 V AC for 1 min. -10 to 50 C (hood may be fitted as option) Storage temperature: -25 to C Construction: JIS C 09 Water-tight (NEMA 4 equivalent waterproof construction) Material: Case: Aluminum alloy casting Finish: Color: Case: Cover: Window: Polycarbonate Baked polyurethane resin coating (standard) Baked epoxy resin coating (optional) Frosty white (Munsell 2.5Y8.4/1.2 or equivalent) Deep sea-moss green (Munsell 0.6G3.1/2.9 or equivalent) Mounting: Pipe mounting, wall or rack mounting or panel mounting Mounting material: Stainless steel Cable inlet port: Ø22.7 hole x 2 DIN Pg16 watertight plastic gland Cable/terminal: For 7 to 12 mm, M4 screw Conduit adapter: Power supply side (optional) Material: Polycarbonate resin Connection: G1/2 or 1/2NPT Weight: Body: Approx. 2.0 kg Mounting: Approx. 0.7 kg Dimension: 162W x 180H x 115D mm Note: 1. Output of ultrasonic oscillator changes with power supply voltage. The output is lower when the voltage is lower. 2. Output of ultrasonic oscillator changes with connected cable. The output is lower when the length of the cable is longer. Noise filter assembly: (for TUS400G-NN-RC, -KC) Ambient temperature: -10 to 50 C (no dew condensation allowed) Strage temperature: -25 to C Construction: JIS C 09 Watertight (IP53) Regulatory Compliance (for TUS400G-NN-RC) EMC Regulatory Arrangement in Australia and New Zealand EN 55011 Class A, Group 1 (for TUS400G-NN-KC) Korea Electromagnetic Conformity Standard Class A 한국전자파적합성기준 All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 13, 14-02

4 Model and Codes 1. TB750G Right Angle Scattered Light Turbidimeter Model Suffix Code Option Code Description TB750G..... Right angle scattered light turbidimeter Turbidity standard and -NTU... Formazin, 0-0.2 NTU to 0-100 NTU measuring range Application -ST... Standard Output -N1 -N2...... 4 to ma DC, RS-422 4 to ma DC, RS-232C Sampling system -NN... Without sampling system Sampling system material and mounting NN... Without sampling system Cable length between converter and detector -1-2 -3......... 1 m 2 m 3 m -NN... Always -NN Option Detector process connection Mounting hardware Conduit adapter Head tank Tag plate Special painting Ultrasonic transducer /NPT /U /R /PM /TBC /AFTG /ANSI /D1 /D2 /SCT /X1 /US ANSI standard connection *1 Pipe mounting hardware (SUS) Rack or wall mounting hardware (SUS) Panel mounting hardware (SUS) Mounting hardware for Model 8562 or Model TB500G replacement (SUS) *2 G1/2 *3 1/2NPT *3 Pressurized head tank for low turbidity (recommended for 2.0 NTU or less) Simple head tank Stainless steel tag plate Epoxy painting *4 Transducer for ultrasonic cleaning *5 *1: When option /NPT is specified, the piping connections of sample water inlet, sample water outlet, and drain port are 1/2NPT, 1/2NPT, and 1NPT respectively. Unless option /NPT is specified, they are Rc1/2, Rc1/2, and Rc1 respectively. *2: This bracket is also available to the detector of Turbidimeter 17E and 17D manufactured by HACH. It is separate type, each for detector and converter. *3: Conduit adapter is for power supply, output and input wiring provided by customer. *4: Converter and detector case are painted with epoxy resin. *5: Specify option /US (ultrasonic transducer) for ultrasonic cleaning. Also TUS400G Ultrasonic Oscillator should be purchased separately. Note: When ultrasonic cleaning is continuously used after the Model 8562 Turbidity Transmitter has been replaced with the TB750G Turbidimeter, this /US option must be specified. 2. TUS400G Ultrasonic Oscillator Model Suffix Code Option Code Description TUS400G. Ultrasonic oscillator for turbidimeter -NN Always NN Application -NN -RC -KC General Australia, for Oceania areas For Korea Supply voltage *2-1 -2-3 -4-5 -6 Ultrasonic vibrator connecting cable -00 -L1 -L2 -L3 -L4-05 -10-15 Language for directions -J Option -E Mounting hardware Hood Tag plate Special painting Adapter for conduit work Special screws 100 V AC, 50/60 Hz 110 V AC, 50/60 Hz 115 V AC, 50/60 Hz 0 V AC, 50/60 Hz 2 V AC, 50/60 Hz 240 V AC, 50/60 Hz None 1 m (for Model TB0G or TB750G) 5 m (for Model TB0G or TB750G) 10 m (for Model TB0G or TB750G) 15 m (for Model TB0G or TB750G) 5 m (for Model 8562) 10 m (for Model 8562) 15 m (for Model 8562) Japanese (Directions indicated on product: Some are written both in Japanese and in English.) English (Directions indicated on product: Some are written both in Japanese and in English.) /PS /W /PA /H /SCT /X1 /AFTG /ANSI /SPS Pipe mounting (SUS) Wall mounting (SUS) Panel mounting (SUS) Sunshade hood Stainless steel tag plate Epoxy painting G1/2 1/2NPT Teflon coated SUS steel screws (resistant to salt corrosion) *1 *1: The SUS screws with Teflon coating are used at the four corners of the cover. *2: The power supply to TB0G or TB750G should be determined in accordance with the supply voltage specified here. 3. Zero Turbidity Filter Assembly Part Name Part No. Filter Assembly, 1 μm K9411UA Filter Assembly, 0.2 μm K9726EF 4. Consumables Part Name Part No. Filter Element, 1 μm K9008ZD Filter Element, 0.2 μm K9726EH Lamp Assembly K9657PW Fuse (3.15 A) A1113EF Desiccant (4 pcs) *1 K9657RJ *1: Use within a year after purchasing. 5. Head Tank Part Name Part No. Description Pressurized head tank Simple head tank K9725WA K9658YA Same as option code /D1 Same as option code /D2 All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

5 Dimensions 1. TB750G Right Angle Scattered Light Turbidimeter Converter 141.5 132 4-M6 screws 150 min. () (141.5) 80 150 min. 50 min. (30) to Detector Detector connecting cable inlet Dedicated cable (1/2/3 m) 6- Cable inlets DIN Pg13.5 Cable gland 80 Maintenance space Grounding terminal (M4 screw) F03.ai Detector Front view 500 min. Side view 500 min. 265 Power cable inlet * Ultrasonic oscillator (for power) connecting cable inlet * ("/US" only) 378 from Converter * Cable gland DIN Pg13.5 Conduit adapter (option code: /AFTG, /ANSI) 180 Converter connecting cable inlet * 250 min. 250 min. 0 min. (378) (297) Sample water outlet Maintenance space Dedicated cable 113 (1/2/3 m) Sample water inlet Ultrasonic transducer connecting cable inlet ("/US" only) * 38 41 56 63 174 60 (265.3) (265) Rc1 or 1NPT F04.ai Nut Case Packing Cable gland Adapter 49 Approx. 55 G1/2 (/AFTG) or 1/2NPT (/ANSI) F12.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

6 Pipe mounting (option code: /U) Converter 132 195 Mounting 2-inch pipe (ø60.5 OD) 224 100 F05.ai Detector 180 12 Mounting 2-inch pipe (ø60.5 OD) Sample water outlet 84 48 2 47 25 Sample water inlet 113 102 Rc1 or 1NPT F06.ai Rack or wall mounting (option code: /R) Converter 154.5 132 224 4-ø10 F07.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

7 Detector (The dedicated mounting bracket is not attached. Install the detector with four M5 screws.) 2-ø6 (fixing holes) Sample water outlet 38 60 160 (for fixing hole) 7 R3 R3 180 174 100 (for fixing hole) 6 6 41 Sample water inlet 113 56 63 Rc1 or 1NPT F08.ai Panel mounting (option code: /PM) Converter 27 15 max.(panel thickness) 4-M6 screws 138 0 +2 100 138 0 +2 195 min. 178 185 min. <Panel cutout> F19.ai Detector (The dedicated mounting bracket is not attached. Install the detector with four M5 screws.) 2-ø6 (fixing holes) Sample water outlet 38 60 160 (for fixing hole) 7 R3 R3 180 174 100 (for fixing hole) 6 6 41 Sample water inlet 113 56 63 Rc1 or 1NPT F08.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

8 Mounting for Model 8562 or Model TB500G replacement (option code: /TBC) Converter 154.5 132 224 4-ø10 F07.ai Detector 4-ø9 (for fixing hole) 112 (for fixing hole) 31 77 () R3 273 (for fixing hole) 100 (for detector fixing screw) 6 4-M5 (fixing screws of detector) 6 R3 7 160 (for detector fixing screw) 41 265 Sample water outlet 38 25 139 174 63 Sample water inlet (for fixing hole) 113 56 Rc1 or 1NPT F09.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

9 Pressurized head tank for low turbidity (option code: /D1) Pressure gauge (Range: 0 to 500 kpa) Needle valve (Material: SUS316) 35 145 Approx. 332 Approx. 127 plug ø6/ø4 PE tube coupling Sample water outlet (to detector) ø6/ø4 PE tube coupling 50 110 140 15 15 4-ø6.2 holes Sample water inlet ø10/ø8 PE tube coupling F10.ai Simple head tank (option code: /D2) 123±5 102 ±5 67±5 5±5 66±5 Vent to the atmosphere Tube size ø19 ID Hose coupling Tube size ø19 ID Hose coupling 4-ø6 38 (for fixing hole) 38 (for fixing hole) 390 (for fixing hole) 795±5 Sample water inlet Rc3/8 271±5 150±5 210.5±5 Sample water outlet (to detector) Rp1/2 26 95.5±5 TS socket type Nominal A (ø26.2 ID) 64.5 F11.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00

10 2. TUS400G Ultrasonic Oscillator 2 155 162 115 130 50 Hood (optional) 96 66.5 180 30 Ground terminal (M4 screw) 42 56 Ultrasonic transducer cable inlet port, with cable gland (DIN Pg16 or equivalent) 2-M5 Screws (for mounting hardware) Power supply cable inlet port, with cable gland (DIN Pg16 or equivalent) Dedicated cable (not applicable in case of "-00") U1 U2 U3 Red White Black Approx. 80 or 180 ø9 Cable length: L (L=1/5/10/15 m) to TUS400G Approx. 60 S U1 U2 U3 F13.ai External dimensions of additional noise filter assembly when TUS400G-NN-RC or TUS400G-NN-KC 275 10 92 4-M5 screws, (depth:10mm) (for mounting) 3 75 17 External power cable inlet (cable OD of Ø6 to Ø12) Dedicated power cable outlet Dedicated power cable for noise filter assembly Black L1 White L2 Green G Approx. 80 152 Cable length : Approx. 0.7 m L1 Black L2 White G Green Approx. 80 Weight of noise filter assembly: Approx. 2 kg Weight of power cable: Approx. 0.2 kg 36 All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 13, 14-02

11 Pipe mounting (option code: /PS) 155 115 48 110 Hood (optional) 27 8 100 ±0.2 56±0.2 2-ø5.5 holes (for hood) 2-inch (ø60.5 OD) pipe (vertical mounting) 288 30 151 2-ø6.6 holes (for oscillator) 3 2-inch (ø60.5 OD) pipe (horizontal mounting) 48 F14.ai Pipe mounting for noize filter assembly (TUS400G-NN-RC.../PS, TUS400G-NN-KC.../PS) 5- Ø6.5 holes 0 35 75 8 Ø6.5 x 13 hole Pipe mounting bracket 1 2- Ø5.5 holes Pipe mounting bracket 2 2-Ø9 holes 4-M5 screws U-bolt 35 M8 nut 2 15 100 4-Ø10 holes (10) (92) (54) Weight: Approx. 0.7 kg 2-inch pipe (vertical mounting OD Ø60.5) Panel mounting (option code: /PA) 1 to 10 (panel thickness) Panel mounting hardware +1.1 156 0 121 30 60 173 138 +1.1 0 138 38 80 3.9 185 121 6 <Panel cutout dimensions> F15.ai Wall mounting (option code: /W) 2-ø5.5 holes (for hood) 8 100 ±0.2 56±0.2 30 60 185 27 13 38 80 3.9 2-ø6.6 holes (for oscillator) 3-ø10 holes 27 15 ±0.2 F16.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 13, 14-02

12 Wall mounting for noize filter assembly (TUS400G-NN-RC.../W, TUS400G-NN-KC.../W) 4-M5 screw 75 8 5- Ø6.5 holes Ø6.5 x13 hole Wall mounting bracket 2- Ø5.5 holes 35 35 0 15 100 4- Ø10 holes 4-M6 screw (customer s scope) (10) (92) 13 Weight: Approx. 0.7 kg Adapter for conduit work (option code: /AFTG, /ANSI) Nut Case Packing Cable gland Adapter 49 Approx. 55 G1/2 (/AFTG) or 1/2NPT (/ANSI) F12.ai 3. Zero Turbidity Filter Assembly OUT 4-M4 fixing screws 44 112.5 Vent plug IN 80 ø115 ø121 Piping inlet & outlet Rc1/2 314 22 22 Filter Part No. K9411UA K9726EF Filtering size 1 μm 0.2 μm 10 F17.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 13, 14-02

13 Wiring Power supply *5 Grounding *1 (100Ω or less) Noise filter assembly *6 TB750G Turbidity detector (Terminal: M4) L N G L N G Power supply cable TUS400G Ultrasonic Oscillator *5 L2 L1 CONVERTER POWER G TUS U1 U2 U1 U2 U3 S Dedicated cable (1/2/3 m) Serial communication *3 *4 Grounding *1 (RS-422) (100Ω or less) Ultrasonic transducer connecting cable (maximum length: 15 m) (customer wiring) input Analog output 1 (4- ma DC) *3 Analog output 2 (4- ma DC or 0- ma DC) *3 Grounding *2 (100Ω or less) TB750G Turbidity converter (Terminal: M3) SENSOR G RX+ RX- TX+ TX- SG G IN1 IN2 COM + - + - G RS-422 ma1 INPUT S1 S2 FAIL RANGE OUTPUT ma2 (Note) Dotted wiring is external wiring. Use cable with 6 to 12 mm OD for wiring. *1 Power terminal "G" on detector, detector case, and converter case must be grounded (ground resistance: 100Ω or less). *2 External grounding terminal of ultrasonic oscillator must be grounded (ground resistance: 100Ω or less). *3 Use 2-conductor shielded cable for analog output wiring and serial communication wiring. *4 The wiring configuration is described below in case that RS-232C serial communication is selected. NO NC COM NO NC COM NO NC COM A B C COM output S1 output S2 output FAIL Range contact output Grounding *1 (100Ω or less) Serial communication (RS-232C) TXD RXD RS-232C SG G *5 When option code "/US" is specified, TUS400G should be purchased separately. When TUS400G is used in system, the power supply to TB750G should be the same as the supply voltage specified in the MS Code of TUS400G. *6 For TUS400G-NN-RC, TUS400G-NN-KC. F18.ai All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 13, 14-02

Enquiry Specifications Sheet for Model TB750G Right Angle Scattered Light Turbidimeter For enquires on the Yokogawa sampling system, please tick (P) the appropriate box o and write down the relevant information in the blanks. 1. General Information Company name; Person; Department; Plant name; Measurement location; Purpose of use; o Indication, o Recording, o Alarm, o Control Power supply; V AC, Hz 14 2. Measurement Conditions (1) Sample water temperature; to, Normally [ C] (2) Sample water pressure; to, Normally [kpa] (3) Sample water flow rate; to [l/min] (4) Slurry or contaminations; o No, o Yes (5) Components of sample water; (6) Others; 3. Installation Site (1) Ambient temperature; approx. [ C] (2) Location; o Indoors (3) Others; 4. Requirements (1) Measuring range; to NTU (2) System configuration selection; o Pressurized head tank for low turbidity measurement (recommended if turbidity is 2.0 NTU or less.), o Simple head tank, o TUS400G Ultrasonic Oscillator o Zero turbidity filter(1 μm), o Zero turbidity filter (0.2 μm) (3) Cable length between converter and detector: o 1 m, o 2 m, o 3 m (4) Others; All Rights Reserved. Copyright 05, Yokogawa Electric Corporation GS 12E01A06-01E 4th Edition Mar. 04, 14-00 Subject to change without notice.