Neutron Irradiation Tests of an S-LINK-over-G-link System

Similar documents
The Read-Out system of the ALICE pixel detector

ECAL LED system update. A. Celentano

The ATLAS Pixel Detector

Local Trigger Electronics for the CMS Drift Tubes Muon Detector

The ATLAS Tile Calorimeter, its performance with pp collisions and its upgrades for high luminosity LHC

Design, Realization and Test of a DAQ chain for ALICE ITS Experiment. S. Antinori, D. Falchieri, A. Gabrielli, E. Gandolfi

THE ATLAS Inner Detector [2] is designed for precision

The ALICE on-detector pixel PILOT system - OPS

arxiv:hep-ex/ v1 27 Nov 2003

Single-Event Upsets in the PANDA EMC

LHCb and its electronics. J. Christiansen On behalf of the LHCb collaboration

Optical Link Layout Options

arxiv: v1 [physics.ins-det] 1 Nov 2015

CMS Conference Report

S.Cenk Yıldız on behalf of ATLAS Muon Collaboration. Topical Workshop on Electronics for Particle Physics, 28 September - 2 October 2015

Towards Trusted Devices in FPGA by Modeling Radiation Induced Errors

Studies of large dynamic range silicon photomultipliers for the CMS HCAL upgrade

SciFi A Large Scintillating Fibre Tracker for LHCb

Development of an Abort Gap Monitor for High-Energy Proton Rings *

First LHC Beams in ATLAS. Peter Krieger University of Toronto On behalf of the ATLAS Collaboration

LHCb and its electronics.

A Serializer ASIC at 5 Gbps for Detector Front-end Electronics Readout

The Alice Silicon Pixel Detector (SPD) Peter Chochula for the Alice Pixel Collaboration

A new Scintillating Fibre Tracker for LHCb experiment

RX40_V1_0 Measurement Report F.Faccio

CMS Tracker Optical Control Link Specification. Part 1: System

The Pixel Trigger System for the ALICE experiment

Front End Electronics

Front End Electronics

Versatile Link. Radiation Qualification

Radiation-Hard Optical Link for SLHC

Sensors for the CMS High Granularity Calorimeter

Irradiation Resistivity and Mitigation Measurement Design for Xilinx Kintex-7 FPGAs

Self Restoring Logic (SRL) Cell Targets Space Application Designs

Atlas Pixel Replacement/Upgrade. Measurements on 3D sensors

Diamond detectors in the CMS BCM1F

Test Report. Product Name: Access Point Model No.: MS-6809 FCC ID: DoC

Electronics for the CMS Muon Drift Tube Chambers: the Read-Out Minicrate.

A pixel chip for tracking in ALICE and particle identification in LHCb

DAQ Systems in Hall A

FRONT-END AND READ-OUT ELECTRONICS FOR THE NUMEN FPD

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

Development of Ultra-High-Density (UHD) Silicon Photomultipliers with improved Detection Efficiency

Product Update. JTAG Issues and the Use of RT54SX Devices

Scintillation Tile Hodoscope for the PANDA Barrel Time-Of-Flight Detector

Data Acquisition System for Segmented Reactor Antineutrino Detector

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

LHC_MD292: TCDQ-TCT retraction and losses during asynchronous beam dump

2008 JINST 3 S Development of new readout electronics for the ATLAS LAr Calorimeter at the slhc

Concept and operation of the high resolution gaseous micro-pixel detector Gossip

OTX Optical Transmitter. Operation Instructions

3-D position sensitive CdZnTe gamma-ray spectrometers

The Readout Architecture of the ATLAS Pixel System. 2 The ATLAS Pixel Detector System

The ATLAS Beam Conditions and Beam Loss Monitors

BABAR IFR TDC Board (ITB): requirements and system description

Performance of a double-metal n-on-n and a Czochralski silicon strip detector read out at LHC speeds

PIXEL2000, June 5-8, FRANCO MEDDI CERN-ALICE / University of Rome & INFN, Italy. For the ALICE Collaboration

A Versatile Multichannel Digital Signal Processing Module for Microcalorimeter Arrays

Status of CMS Silicon Strip Tracker

PICOSECOND TIMING USING FAST ANALOG SAMPLING

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

Evaluation of an Optical Data Transfer System for the LHCb RICH Detectors.

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

PulseCounter Neutron & Gamma Spectrometry Software Manual

Quick Report on Silicon G-APDs (a.k.a. Si-PM) studies. XIV SuperB General Meeting LNF - Frascati

GERDA GeDDAQ. Status, operation, integration. INFN Padova INFN & University Milano. Calin A. Ur

1. General principles for injection of beam into the LHC

Double Screening Tests of the CMS ECAL Avalanche Photodiodes

DIGITAL INSTRUMENTS S.R.L. SPM-ETH (Synchro Phasor Meter over ETH)

A Flash Time-to-Digital Converter with Two Independent Time Coding Lines. Ryszard Szplet, Zbigniew Jachna, Jozef Kalisz

Photo Multipliers Tubes characterization for WA105 experiment. Chiara Lastoria TAE Benasque 07/09/2016

Design of a Gaussian Filter for the J-PARC E-14 Collaboration

COLORSCAN. Technical and economical proposal for. DECOSYSTEM / OFF.A419.Rev00 1 of 8. DECOSYSTEM /OFF A419/09 Rev November 2009

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

CMS Tracker Synchronization

Chapter 4: One-Shots, Counters, and Clocks

US CMS Endcap Muon. Regional CSC Trigger System WBS 3.1.1

Operating Experience of Broadband Acquisition System on RT-13 Radio Telescopes

DTMROC-S: Deep submicron version of the readout chip for the TRT detector in ATLAS

Coincidence Detection using the Broadcom AFBR-S4N44P163 4 x 4 SiPM Array and the Vertilon SIB916 Sensor Interface Board Application Note

CAEN Tools for Discovery

The Scintillating Fibre Tracker for the LHCb Upgrade. DESY Joint Instrumentation Seminar

Libera Hadron: demonstration at SPS (CERN)

Status of GEM-based Digital Hadron Calorimetry

Testing and Characterization of the MPA Pixel Readout ASIC for the Upgrade of the CMS Outer Tracker at the High Luminosity LHC

Level 1 Calorimeter Trigger:

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

T E S T - R E P O R T. No for. SLG 42 MOBY Component

Status of readout electronic design in MOST1

KEK. Belle2Link. Belle2Link 1. S. Nishida. S. Nishida (KEK) Nov.. 26, Aerogel RICH Readout

Low-Energy Electron Linacs and Their Applications in Cargo Inspection

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Precision testing methods of Event Timer A032-ET

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

Spectroscopy on Thick HgI 2 Detectors: A Comparison Between Planar and Pixelated Electrodes

CSC Data Rates, Formats and Calibration Methods

Beam test of the QMB6 calibration board and HBU0 prototype

The Readout Architecture of the ATLAS Pixel System

FRANCO MEDDI CERN-ALICE / University of Rome & INFN, Italy. For the ALICE Collaboration

Transcription:

Nov. 21, 1999 Neutron Irradiation Tests of an S-LINK-over-G-link System K. Anderson, J. Pilcher, H. Wu Enrico Fermi Institute, University of Chicago, Chicago, IL E. van der Bij, Z. Meggyesi EP/ATE Division, CERN, Geneva, Switzerland J. Adams National Institute of Standards and Technology, Gaithersberg, MD 1. Objective This note describes neutron irradiation tests of an S-LINK [1] source card (LSC) which incorporates the Hewlett Packard G-link chip set [2]. The test was designed to evaluate the use of this technology in the ATLAS Tile Calorimeter. At the position of this card the nominal neutron flux is 10 10 1-MeV-equivalent-n/cm 2 /year and the expected dose from ionizing radiation is 0.02 Krad/yr. Based on 10 years operation at design luminosity and a safety factor of 5, the card must withstand a neutron fluence of 5 10 11 n/cm 2 and a dose from of ionizing radiation of 1 Krad. Single event upset is also an important consideration and was carefully monitored. 2. Neutron Source Characteristics FLUKA prediction for ATLAS Cf-252 Figure 1: Neutron energy spectrum from Cf 252 together with expected spectrum in ATLAS. The test was performed at the National Institute of Standards and Technology (NIST) in Gaithersburg Maryland using a Californium 252 fission source which produced 5.0 10 9 n/s. The test exposure lasted for 3 weeks; a period short compared to the 2.65 year half-life of Cf 252. The neutron energy spectrum of Cf 252 is shown in Fig. 1. It has a peak at ~ 0.7 MeV and a mean energy of 2.14 MeV. Approximately 7% of the neutrons have an energy above 5 MeV. A prediction of the neutron spectrum in the ATLAS gap region using the FLUKA Monte Carlo program is also shown in Fig. 1. The variation with energy is a good match to

the Cf-252 spectrum [3]. A convolution of the spectrum with the energy dependent displacement damage function for neutrons in silicon indicates that the neutrons from Cf 252 cause 1.06 times the damage of 1 MeV monochromatic neutrons [4]. In the analysis below this factor is treated as a safety margin and has not been applied. The source also produces a modest flux of photons. The dose from ionizing radiation from an unshielded Cf-252 source is 2.9 Krad for 10 12 n/cm 2 [5]. 3. S-LINK System The test used an S-LINK-over-G-link combination of source and destination cards specially prepared for the study of link errors [6]. The cards used Hewlett Packard HDMP-1022/1024 transmitter/receiver chips operated in 20-bit, single frame mode with a 40 MHz clock. The optical transmitter on the LSC was a Methode MDX-19-4-1-S and an Actel A54SX16 FPGA was used for logic control. The 40 MHz oscillator was a Temex QEN 47-CH. The data pattern sent by the LSC was set by switches on card and the setting was downloaded to the LDC card through its computer connection. The pattern used for this test had alternate bits set. The LSC generated the test data at the full link speed of 640 Mb/s. The data were compared in the LDC to the expected pattern and only transmitted to the monitoring computer in case of a discrepancy. Errors related to link protocol were also transmitted. We note that in the TileCal application the data rate over the optical link is 346 Mb/s for the maximum LVL1 trigger rate of 75 KHz. 4. Test Configuration The source was placed ~10 cm from the face of the LSC with the card normal to a line from the source. To reduce the photon dose, 6 mm of lead shielding was placed between the source and the card. This is estimated to reduce the neutron flux by ~12% and the photon dose by >40%. For this configuration the neutron flux at the center of the card was 3.0 10 11 n/cm 2 /day. The LDC card was placed in a low radiation environment and connected to the LSC by a 30-m-long simplex optical fiber. Data errors detected by the S-LINK LDC were transferred to a PC via a PCI interface card [7] and were logged to disk using a simple data acquisition program. The clock time of each error was logged with the data. 5. Test Results The test began September 1, 1999 and ended September 19 with a fatal failure of the LSC because of the voltage regulator transistor. During this period the card received a total neutron fluence of 5.7 10 12 n/cm 2, or approximately 10 times the required level.

The errors fall into two categories; single-word errors, 20 and blocks of errors lasting 18 Single-word Errors more than 10 microseconds. 16 14 12 10 8 6 4 2 0 Block Errors The latter are likely associated with loss of synchronization of the link. The distribution of these errors over the duration of the test is shown in Fig. 2. The average rate of singleword errors was 9.5 per day and the rate of block errors 0.74 per day. For the neutron 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 flux of this test these figures Day (September) correspond to one single-word Figure 2: Time distribution of errors. error per 3.2 10 10 n/cm 2 and one block-error per 4.1 10 11 n/cm 2. For the ATLAS TileCal system with 256 links, and at the nominal neutron flux for the design luminosity of the LHC given in Section 1, they correspond to 6.7 single-word errors and 0.53 block errors per month anywhere in the system. Number of Errors Number of Errors 20 18 16 14 12 10 8 6 4 2 0 Glink error data error parity error 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Day (September) Figure 3: Breakdown of errors according to type. errors are flagged by the parity bit. Errors were classified as G- link internal errors, data mismatch, parity mismatch, and frame-length mismatch. These errors can arise from single event upset of any of the components on the LSC. An analysis of the data showed no frame length mismatch errors. The rate of other types of errors is shown in Fig. 3. Most error events involved more than one type of error and correspond to several entries in Fig. 3. Note that most 6. Conclusions 1. The survivability of the S-LINK-over-G-link system under neutron irradiation has been satisfactorily demonstrated. The system continued to operate at 10 times the required neutron fluence.

2. The observed rate of single-word errors would correspond to 6.7 per month from the entire ATLAS TileCal system for the nominal neutron fluence indicated in Section 1. Since these errors are detectable from parity information, and since the data itself has considerable redundancy, this error rate should not pose a problem; nevertheless, the ROD modules which receive the data must test for these errors and take appropriate action. The actual error rate in ATLAS should be lower because the link will only be used with a duty factor of ~50% of that used here. 3. The observed rate of block errors would correspond to 0.53 per month from the entire TileCal system. Such errors would result in the loss of all data from one electronics drawer (1/256 th of the system) for a number of consecutive events. If these errors correspond to loss of link synchronization the recovery time is estimated to be ~ 0.5 ms [8]. At the maximum LVL1 trigger rate this would correspond to a block of ~ 40 events. The fraction of LVL1 triggers affected by such an error would be ~10-10. Such a loss appears entirely acceptable but an ATLAS-wide policy would be helpful for reaching a conclusion. These block errors correspond to a bit error rate on a single link in the nominal TileCal neutron environment of 4 10-13. 4. These results correspond to the Cf-252 neutron spectrum given Fig. 1 which closely approximates 1 MeV neutrons. A more detailed calculation of the neutron spectrum in the TileCal electronics drawers would be desirable, particularly the region above 5 MeV. 5. During this test the LSC was exposed to 9.9 Krad of ionizing radiation. Separate studies have indicated that the system remains fully functional to over 20 Krad [9]. References: 1. Details on the S-LINK system can be found at: http://www.cern.ch/hsi/s-link/. 2. The G-link system is described at: http://www.semiconductor.agilent.com/io/hdmp1022.html. 3. The FLUKA calculation was done by P. Sala and applies to the gap region of the detector where the LAr electronics is located. The spectrum inside the TileCal electronics drawers could be somewhat softer. 4. S. Reucroft et al., Nucl. Instr. & Meth. A394, 199 (1997) and J. Swain, private communication. 5. R. Martin, Oak Ridge National Laboratory, private communication.

6. Further details on this system are available at: http://www.cern.ch/hsi/slink/devices/g-lsc/. 7. The S-LINK to PCI interface card is described at: http://www.cern.ch/hsi/slink/devices/slink-pci/. 8. This is believed to be an upper limit since preliminary measurements reported by Mark Pearce give 0.3 ms. 9. Zoltán Meggyesi et al., FPGA Design in the Presence of Single Event Upsets, poster session paper presented at the LEB Workshop, Snowmass, Colorado, Sept. 20-24, 1999.