3M Cold Shrink Foldback Splice Jacket Kit

Similar documents
3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

Instructions. Cable with Armor F CAUTION. October Rev A

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3M Sensored Termination (15 kv) QX-T15I-vi1-E

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

3M Cold Shrink Rubber Splicing Kit 5552

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

HSK Mine and Portable Cable Splice

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

3M Better Buried Closures

Cold Shrink Silicone Rubber Termination QT-II

3M Better Buried Compound Compression Closure System

3 SLiC Aerial Closure with Rubber End Seal

Scotch Heavy Duty Vinyl Electrical Tape 22

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

3M Distribution Box (DDB)

3M Coupling Tray FDTC-10S-COUPLINGTRAY

3M Super 23 Electrical Tape

3M Locator Plate N

Solutions for Electronic Specialty Markets (ESM)

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

SLiC Fiber Aerial Closure System

Cabinet Tools and Accessories Ordering Guide

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

3M Merchandising Catalog. Unrivaled. Product Presence to. Meet Your Merchandising Needs

3M Slim Lock Closures

3M 8900 Single-mode SC Crimplok Connector

18mm ECAM Cable Entry Port

3M No Polish Jacketed SC/APC Connector

Industrial Loadbreak Elbow

K & B Flame Retardant Building Riser Closures

27mm ECAM Double Cable Entry Port

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

Cold Shrink Straight Joint

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

3M No Polish Jacketed SC/APC Connector

Communication Markets Division 3M Scotchlok Connectors and Tools. Proven. Solutions for. Today s Applications

Communication Markets Division. 3M Fiber Closures. Smart design makes your job easier.

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

Instruction Guide February 2017

Scotchlok Connectors and Tools

Built tough for long-term connections

Built tough for long-term connections

3M Fiber Optic Closure System LL

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M MetPak 2-FB Header

SLiC Fiber Aerial Closure 533 and 733

3M We are Projectors! When the show must go on, 3M makes it easy:

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE 3M Junction Box (JBOX)

3M Fiber Closures BPEO

3M Cross-Connect Cabinets 4220SVB, 4220SVC and 4220SVE Skirt and Stabilizers

2178-L/S Series Fiber Optic Splice Case with Gasket

Rotor Blade Protection Kit 8999K11

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Fiber Optic Wall Mount Enclosure 8430 Series

Coaxial Cable Feedline Choke Kit - 50 Ω

Dynatel Advanced Cable Locator 2250

3M ScotchCode Wire Marking and Identification System. Identify with 3M

3M Pak 10 Socket 1 mm Straight and Right Angle, Surface Mount PK10 Series

3M One Pass Mini Fiber Pathway

3M New Construction Cross-Connect Cabinets. The. Commitment. Your Copper Requires

Electrical Markets 3M ScotchCode Wire Marking and Identification System. Quality. Marking. For Most Projects

4320 SS-25 Self-Strip Terminating Block

3M Mini D Ribbon (MDR) Cable Assembly

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

Instructions for Use of Overlap Seam Repair Kit:

Medium Box for Cable Termination

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Installation Instructions

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

Weatherproofing Coaxial Cable Connections

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Installation instructions Roxtec CM PE systems

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

Installation instructions Roxtec RM ES B

Crimplok. Connectors. 3M Crimplok ST* Connector Multimode 1. 3M Crimplok SC Connector Single-mode 2

3M Pressurized Closure System 2-Type 505

Installation instructions Roxtec RM PE B

Better dispensing, better results.

Transcription:

3M Cold Shrink Foldback Splice Jacket Kit SJ-FB Instructions! CAUTION Working around energized systems may cause serious injury or death. Installation should be performed by personnel familiar with good safety practice in handling electrical equipment. De-energize and ground all electrical systems before installing product. Ground Connector 2228 Rubber Mastic External Ground (Optional) Foldback Splice Jacket June 2013 3 78-8126-6403-1-B

1.0 Kit Contents 1 Cold Shrink Foldback Jacket Assembly 2 Rolls of Scotch Rubber Mastic Tape 2228 3 Mastic Strips 1 Instruction Sheet Kit Selection Table NOTE: Final Determination Factor is cable insulation diameter. Jacket Kit Minimum Cable Jacket O.D. Maximum Splice O.D. Maximum Cable Jacket Opening SJ-1FB 0.95 (24,1) 2.00 (50,8) 25 (635) SJ-2FB 1.15 (29,2) 3.00 (76,2) 31 (787) SJ-3FB 1.55 (39,4) 3.62 (91,9) 34 (864) Works with 3M Splice Number 15 kv 25 kv 35 kv 5411 5411A 5412 5403 5404 5405 5406 5407 5408 5409 Approximate Parking Space Required 20 (510) 5420 5421 5422 5451 5451A 5452 5423 5424 5425 5426 5432 5461 22 (560) 5433 24 (610) SJ-4FB 1.75 (44,5) 4.10 (104,1) 32 (810) 24 (610) Note: the above dimensions should be used to determine sizing for non-3m splices. 2.0 Splice Jacket Kit Instruction Table 1 2.1 Prepare the cable according to splice manufacturer s instruction. 3M recommends locating the neutral wire connector beyond one end of the splice body (see Figure 2). If an external ground is required, locate the ground connection off splice body. 2.2 Park the cold shrink jacket assembly onto cable X (cable with the largest jacket cutback) (Figure 1). NOTE: The cold shrink jacket assembly may be moved as necessary during splice assembly. Loose Core End Splice Body Loose Core End Jacketing Tube Figure 1 2.3 Install the splice body and all other splice components per manufacturer s instructions. 2 78-8126-6403-1-B

3.0 Grounding (Optional) Note: Use these instructions if circuit grounding is required at this location. 3.1 Connect a ground wire to the neutrals, in the area where the splice diameter is reduced. To protect the cable semicon, place a piece of cable jacket (removed during the cable preparation) under the ground connector. Ensure that the cable jacket piece does not touch the splice body. Keep connector profile as low as possible. For C-Tap or H-Tap connectors, position flat against the cable. (Figure 2) Ground Wire Piece of Cable Jacket Figure 2 3.2 Cut one mastic sealing strip into two equal pieces. Place one piece on the cable jacket centered under the ground wire, near the jacket end (Figure 3). 1/4" (6 mm) Ground Wire 1/2 Mastic Strip Figure 3 3.3 Remove the liner from one side of 2 mastic strips. Roll each strip into a tight roll as shown (Figure 4). Liner Mastic Strip Liner Figure 4 78-8126-6403-1-B 3

3.4 Place one small mastic roll on each side of the ground wire. Place the other half strip over ground wire and two rolls. Press the mastic around the ground wire and to the cable jacket (Figure 5). Mastic Roll External Ground Wire 1/2 Mastic Strip 1/2 Mastic Strip Figure 5 3.5 Overwrap the ground wire connectors with vinyl tape (Figure 6). Vinyl Tape 4.0 Install Jacket Note: Jacketing is not optional. Figure 6 4.1 Apply one roll of slightly stretched rubber mastic tape around each jacket end (tacky side toward cable). If ground wire is connected, apply tape over mastic sealing strips. Stretch and tear off the end of the rubber mastic (Figure 7). 1/4 (6 mm) Neutral Wires Rubber Mastic Figure 7 4 78-8126-6403-1-B

4.2 Begin to install the cold shrink tube by completely covering the rubber mastic, and slowly pulling and unwinding the inner core counterclockwise toward the splice body. The outer core should remain relatively stationary while unwinding the inner core. If the outer core begins to move towards the first mastic seal, gently pull the outer core and jacketing tube towards the second mastic seal and continue unwinding the inner core. (Figure 8) Unwind Counterclockwise Cold Shrink Jacketing Tube Figure 8 4.3 Continue to install the cold shrink tube over the rubber mastic on the other cable by slowly pulling and unwinding the outer core counterclockwise. This portion of the cold shrink tube installs differently than typical cold shrink products in that as the tube shrinks, the end rolls under. The tube may need a slight push to get over the second mastic seal. (Figure 9) Unwind Counterclockwise Cold Shrink Jacketing Tube Figure 9 Note: In applications where the splice is regularly exposed to high levels of ultra-violet radiation (i.e. direct sunlight), wrap two half-lapped layers of Scotch Super 33+ Vinyl Electrical Tape or Scotch Vinyl Electrical Tape Super 88 over the re-jacketing tubes. Note: Connect optional grounding. 4.4 Completed Splice (Figure 10) Figure 10 78-8126-6403-1-B 5

3M, Scotch, and Scotch Super 33+ are trademarks of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M's products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M's current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture at the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. 3 Electrical Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 800.626.8381 Fax 800.828.9329 www.3m.com/electrical Please Recycle. Printed in USA. 3M 2013. All Rights Reserved. 78-8126-6403-1-B