GR circuit breaker - hydraulic magnetic, Datasheet

Similar documents
GR circuit breaker - hydraulic magnetic, Datasheet

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

XT-17M-B relay - Delay-off, 1 C/O, 16 A

D-B relay - High DC breaking capacity, Datasheet

Magnetic and Hydraulic-Magnetic Circuit Breaker

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Series CT7N Bimetallic Overload Relays

Magnecraft Power Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

High performance circuit breakers

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

MILLITARY SPECIFICATION SHEET

Power Circuit of a UL508A Panel. Typical UL489 Application

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

ORDERING Page 6 STANDARDS, DIMENSIONS and ACCESSORIES Request bulletin SDA

AC1036. Definite Purpose Contactors

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Modular pulse operated latching relay 16 A

Series CDP2 Definite Purpose Contactors

Type: DILM25 10(24V50HZ) Article No.:

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Type: DILM12 10(24VDC) Article No.:

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

02/11/2015

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LED control gear Compact fixed output

Type Contact form Model

Series CDP2 Definite Purpose Contactors

AS09..S 3-pole Contactors - Spring Terminals

Kuhnke Technical Data. Contact Details

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Ordering details. Approval. Classification

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

Bulletin 190 IEC Modular Starter System

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Datasheet - SRB-E-201ST

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

LED Driver Compact fixed output

Minicontactorrelay,2NO/2NC,DCoperated

Datasheet - SRB301LC 24VAC/DC

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

3.5. Control Relays and Timers. Contents. 9575H Series 3000 Type AA, AC and DC. General Purpose Relays Type AA

Non Magnetic Connectors

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

LED Driver Compact fixed output

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

EXPlora. Introduction

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

GV2ME. Main. Device short name. Device application

SQM40/41 Actuators for air and gas dampers

LED Driver Compact dimming

Gamma instabus. Technical product information

Fibre Optic Modem ODW-611

GV2P05. Main. Device short name. Device application

INCH-POUND MIL-PRF-55629/21G 10 March 2010 SUPERSEDING MIL-PRF-55629/21F 21 September 2005 PERFORMANCE SPECIFICATION SHEET

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

Solid-State Digital Timer

8D with High Frequency Coaxial Contact

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

10 PDUs 19 PDUs Zero-U PDUs

LED Driver Linear / area fixed output

10 SERIES. Light dependent relays A

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Interface Relays and Optocouplers Product group picture

75 Ohm N Male Connector Crimp/Solder Attachment for RG6

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

PERFORMANCE SPECIFICATION SHEET

Transcription:

GR circuit breaker - hydraulic magnetic, Datasheet railway, 35 mm rail Description Compact hydraulic magnetic circuit breaker for railway applications, to protect electronic equipment and components against unintended high currents. Optional with integrated auxiliary contacts to monitor the circuit. The trip point is always at maximum allowable current, independent of ambient temperature. Mid-trip handle to indicate clearly a breaker operation caused by electrical fault. With unique arc chute design which results in high interrupting capacities. Integrated 35 mm rail connection for easy and quick mounting on 35 mm rails. Wide range of currents and options available. Application GR circuit breakers are used in every application where electrical systems, circuits or components must be protected against too high currents. This situation can occur, when under strained or heavy use a motor or other load-generating component within the equipment will draw additional current from the power source. High currents cause the wires or components to overheat and ultimately burn up. A circuit protection device should be employed at any point where a conductor size changes. Many electronic circuits and components like transformers have a lower overload withstand threshold level than conductors such as wires and cables. These components require circuit protection devices featuring very fast overload sensing and opening capabilities. GR circuit breakers can be used in all railway applications where protection against overload and short circuit is necessary, for example HVAC systems, (door) control systems, braking systems, passenger information systems, etc. Features Precise, temperature independent operation 35 mm rail mount Integrated auxiliary contacts with screw terminals or Combicon connector (optional) Up to 4 poles configuration High interrupting capacities due to unique arc chute method Mid-trip handle for electrical trip indication (optional) Immediate resetting possible Wide current range: 0.2-63 A Wide choice of time delays Maximum voltage 37.5 VDC / 484 VAC High contact pressure & longer contact life due to wiping self-cleaning contacts Benefits Proven reliable Long term availability Low life cycle cost No maintenance Railway compliancy All our circuit breakers are designed according: IEC 60077-/2/3/4 IEC 60947-2 NF F62-00 - /2/3 NF F6-0/02 EN 45545-2 EN 5055 EN 6373 EN 5024- IEC 60068-2-30 IEC 60068-2-52 NF F6-00 MIL-STD 202G Method 07D, test condition A MIL-STD-202G, method 06D

Technical specifications Electrical characteristics Application voltage Rated voltage Min. operating voltage Max. operating voltage DC for -4 poles 2-0 VDC 8.4 VDC 37.5 VDC AC for -2 poles 2-240 VAC 0.8 VAC 264 VAC AC for 3-4 poles 2-440 VAC 0.8 VAC 484 VAC Current ratings Dielectric strength Creepage and clearance Insulation resistance Operating frequency 0.2 63 A. The GR circuit breaker is polarity insensitive. (except single pole DC breaker) 3000 VAC, 50/60 Hz for minute between all electrically isolated terminals. EN 5024-8 mm spacing requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits. Minimum of 00 MΩ @ 500 VDC 6 2/3 / 50 / 60 Hz, DC Overload 2 operations at 600% of the rated current AC, 250% DC per IEC 60947-2 Max. interrupting cap. IEC 60077 Auxiliary switch IEC 60947-2 3000 A @ 37.5 VDC, 63 A (-pole) 5000 A @ 37.5 VDC, 63 A (2-pole) 5000 A @ 264 VAC, 63 A (- or 2-pole) 4000 A @ 484 VAC, 63 A (3- or 4-pole) 0000 A @ 63 VDC, 63 A (-pole) 2500 A @ 6 VDC, 63 A (-pole) 8200 A @ 6 VDC, 63 A (2-pole) 5000 A @ 252 VAC, 63 A (-pole) 4000 A @ 462 VAC, 63 A (3- or 4-pole) 4000 A @ 572 VAC, 0 A (2-pole) Integrated, load side. SPST. Auxiliary switch senses the on-off position of circuit breaker handle, as well as the open-closed position of breaker contact. AC min. switching cap. Silver auxiliary contacts 5-20 VAC: 00 ma > 20 VAC: 0 ma Gold auxiliary contacts 5 ma / 5 VAC AC max. switching cap. 5 A / 25 VAC 00 ma / 25 VAC DC min switching cap. < 20 VDC: 00 ma > 20 VDC: 0 ma 5 ma / 5 VDC DC max. switching cap. 3 A / 32 VDC 00 ma / 32 VDC 2

Technical specifications Mechanical characteristics Endurance Trip free mechanism Mid trip indication 0.000 On-Off operations with rated current & voltage. Trips on short-circuit or on overload, even when actuator is forcibly held in the On position. The operating handle moves positively to the mid position and an auxiliary switch is actuated, when an overload or a short circuit causes the circuit breaker to trip. General characteristics Number of poles Terminals Auxiliary contacts Mounting Body Actuator Int. circuit configuration, 2, 3 or 4 poles Line terminal: dual connection, see form & fit drawings Minimum wire size:.0 mm 2 Maximum wire size: 9.0 x 9.0 mm Busbar/tab connection thickness range:.9 ~.57 mm (0.047 ~ 0.062 inches) Load terminal: see form & fit drawings Minimum wire size:.0 mm 2 Maximum wire size: 8.7 x 6.5 mm Busbar/tab connection thickness range:.9 ~.57 mm (0.047 ~ 0.062 inches) Wires of different cross sectional area in one terminal is not recommended. 2 wires of identical cross sectional area in one terminal is possible with restrictions. Contact Mors Smitt for more information. Torque value (line & load): nominal 2.8 Nm with tool tolerance +/- 0. Nm, maximum 2.9 Nm Captive screws. Minimum wire size: 0.2 mm 2 Maximum wire size:.5 mm 2 Maximum torque value 0.4 Nm Wire strip length: 5.5 mm Combicon connector, see page 5 35 mm rail lock is located at bottom of circuit breaker (load terminal side) when mounted vertically (wall mount position). The hydraulic-magnetic circuit breakers of Mors Smitt can be mounted in any position. A hydraulic-magnetic breaker is designed to must hold at 00% of the breaker s current rating and is calibrated to must trip at 25% of the breaker s current rating. If the mounting position is +90 degrees from a vertical panel mount (handle facing down, ceiling mount position) the trip and must hold rating is reduced by 0%. Blue colour Handle, white or black with I O and/or On-off legends Series trip & switch only Weight -pole without aux. contact 2-pole without aux. contact 3-pole without aux. contact 4-pole without aux. contact 35 g 270 g 405 g 540 g -pole with aux. contact 2-pole with aux. contact 3-pole with aux. contact 4-pole with aux. contact 40 g 275 g 40 g 545 g Width per pole 7.5 mm Material Half shell - BMC 605 Handle - Valox 420SEO UL94V0 Terminals - Brass with acid tin plate (weight per pole ~ 69.4 g) (weight per pole ~.2 g) 3

Technical specifications Environmental characteristics Environmental Complies to EN 5025- and IEC 60077- Operating temperature -50 C...+85 C Vibration Shock Thermal shock IEC 6373, Category, class B body mounted IEC 6373, Category, class A & B body mounted Complies to MIL-STD 202G method 07D, test condition A Salt mist Complies to IEC 60068-2-52 severity level 3 Damp heat Complies to IEC 60068-2-30 test method Db variant Fire & smoke Complies to NF F 60, NF F 602, EN 45545-2 Protection Moisture resistance / humidity IEC 60529, IP40 when a panel is mounted over the circuit breaker; when no panel is mounted IP20 Complies to MIL-STD 202G method 06D Resistance, impedance Resistance, impedance values from Line to Load terminals (Values based on series trip circuit breaker) 000 00 Current (amps) Tolerance (%) 0.0-5.0 5.- 20.0 + 5% + 25 % 20. - 63.0 + 35 % 0 Ohms 0. 0.0 0.00 0.0 0. 0 00 Ampere rating 4

Technical specifications Auxiliary contact with Combicon connector The GR circuit breaker with auxiliary contact with Combicon connector has no screw terminals but a (male) Phoenix Combicon connector inside. Wires can be connected to (female) Combicon plugs, which can easily be connected to the Combicon connector inside the circuit breaker. Advantages: - Pre-wiring is possible - Time saving solution - Many different Combicon plugs available, for example spring clamp terminals, screw terminals, terminals under different angles or position, with or without integrated test points, etc. Combicon connector Plug with spring-clamp Plug with wires connected GR circuit breaker with connection Combicon plug and wires connected. Example Combicon plugs Spring clamp Screw terminals Screw terminals 45 angle Dimensions in mm Wire size solid wire 0.2 -.5 mm 2 0.2-2.5 mm 2 0.2-2.5 mm 2 Wire size stranded wire 0.2-2.5 mm 2 0.2-2.5 mm 2 0.2-2.5 mm 2 Wire size stranded wire with ferrule 0.25 -.5 mm 2 0.25-2.5 mm 2 0.25-2.5 mm 2 Wire stripping length 0 mm 7 mm 7 mm Phoenix item number 732755 779848 768778 For other Combicon plugs see www.phoenixcontact.com Phoenix item number internal Combicon connector: 753453. The circuit breaker is standard delivered without Combicon plugs. 5

Technical specifications GR circuit breaker with diode inside auxiliary contact If there are several circuit breakers connected to one I/O card, the diode in the auxiliary contacts makes it possible to detect which circuit breaker has tripped. This can reduce the number of I/O cards. Type of diode: N4007 Auxiliary contact schematic Screw terminals Combicon connector 4/NO 2/NC 2/NC 4/NO Connection example (screw terminals) /C /C 4 4 4 4 4 Input Input 2 Input 3 Table of time delay values DELAY 00% 25% 35% 50% 200% 400% 600% 800% 000% 200% 0 No Trip May Trip ---.032 MAX.024 MAX.020 MAX.08 MAX.06 MAX.05 MAX.03 MAX No Trip.03 -.25 ---.00 -.070.008 -.032.006 -.020.005 -.020.004 -.020.004 -.020.004 -.020 2 No Trip.500-6.50 ---.300-3.00.30 -.20.03 -.220.0 -.20.004 -.090.004 -.060.004 -.040 4 No Trip 2.00-60.0 ---.20-40.0.600-20.0.50-3.00.030 -.30.004 -.600.004 -.00.004 -.00 6 No Trip 45.0-345 --- 20.0-50 9.00-60.0.40 -.4.50-5.80.009-3.70.005 -.70.005 -.500 20 No Trip May Trip ---.040 MAX.035 MAX.030 MAX.025 MAX.020 MAX.07 MAX.05 MAX 2 No Trip.04 -.50 ---.0 -.095.008 -.055.006 -.035.005 -.027.005 -.02.004 -.08.004 -.07 TRIP 22 No Trip.700-2.0 ---.350-4.00.30 -.30.027 -.220.008 -.30.004 -.090.004 -.045.004 -.040 TIME 24 No Trip 0.0-60 --- 6.00-60.0 2.20-20.0.300-3.00.050 -.30.007 -.500.005 -.060.005 -.040 (SECONDS) 26 No Trip 50.0-700 --- 32.0-350 0.0-90.0.50-5.0.500-7.00.020-3.00.006-2.00.005 -.00 42 No Trip.700-2.0 ---.400-6.00.80-2.30.050 -.600.026 -.300.08 -.200.04 -.50.02 -.30 44 No Trip 7.00-00 --- 3.00-50.0.0-8.0.220-3.00.20 -.70.075 -.20.050 -.850.042 -.720 46 No Trip 50.0-700 --- 3.0-350 2.0-50.50-20.0.700-0.0.404-7.90.260-6.50.98-5.80 52 No Trip.500-6.50 ---.340-4.50.80-2.30.05 -.600.030 -.320.08 -.220.04 -.200.02 -.30 54 No Trip.50-50.0 ---.750-35.0.350-8.0.0-3.00.070 -.70.045 -.40.039 -.30.035 -.30 56 No Trip 45.0-345 --- 9.0-70 8.50-00.24-5.0.40-9.00.256-8.00.20-5.50.98-2.90 Notes: Delay curves, 2, 4, 6, 2, 22, 24, 26, 42, 44, 46, 52, 54, 56: Breakers to hold 00% and must trip at 25% of rated current and greater within the time limit shown in this curve Delay curves 0, 20: Breakers to hold 00% and must trip at 50% of rated current and greater within the time limit shown in this curve All curves: Curve data shown represents breaker response at ambient temperature of 25 C (77 F) with no preloading. Breakers are mounted in standard wall-mount position. Delay times may vary at different temperature, the trip current rating remains unchanged On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 2 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz /2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. 6

Time delay values AC Instantaneous Medium 0000 000 50/60 Hz INSTANTANEOUS CURVE NO. 20 0000 000 50/60 Hz MEDIUM DELAY CURVE NO. 24 00 0. 00 0..0.0.00 00 200 300 400 500 600 700 800 900 25 50 000 00 200.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 Ultrashort Long 0000 000 50/60 Hz ULTRASHORT DELAY CURVE NO. 2 0000 000 50/60 Hz LONG DELAY CURVE NO. 26 00 0. 00 0..0.0.00 00 200 25 50 300 400 500 600 700 800 900 000 00 200.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 Short 0000 000 50/60 Hz SHORT DELAY CURVE NO. 22 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 7

Time delay values High Inrush AC Short 0000 000 50/60 Hz - HI-INRUSH SHORT DELAY CURVE NO. 42 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 Medium 0000 000 50/60 Hz - HI-INRUSH MEDIUM DELAY CURVE NO. 44 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 Long 0000 000 50/60 Hz - HI-INRUSH LONG DELAY CURVE NO. 46 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 8

600 700 800 900 000 00 200 GR circuit breakers Time delay values DC Instantaneous Medium 0000 000 D.C. INSTANTANEOUS CURVE NO. 0 0000 000 D.C. MEDIUM DELAY CURVE NO. 4 00 0..0 00 0..0.00 00 200 300 400 500 600 700 800 900 000 50 00 200.00 00 200 300 400 500 25 50 Ultrashort Long 0000 000 D.C. ULTRASHORT DELAY CURVE NO. 0000 000 D.C. LONG DELAY CURVE NO. 6 00 0. 00 0..0.0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50.00 00 200 300 25 50 400 500 600 700 800 900 000 00 200 Short 0000 000 D.C. SHORT DELAY CURVE NO. 2 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 9

Time delay values High Inrush DC Short 0000 000 D.C. - HI - INRUSH SHORT DELAY CURVE NO. 52 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 Medium 0000 000 D.C. - HI - INRUSH MEDIUM DELAY CURVE NO. 54 00 0..0.00 00 200 300 25 50 400 500 600 700 800 900 000 00 200 Long 0000 000 D.C. - HI - INRUSH LONG DELAY CURVE NO. 56 00 0..0.00 00 200 300 400 500 600 700 800 900 000 00 200 25 50 0

Form & fit drawings GR pole without auxiliary switch Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ±

Form & fit drawings GR pole with auxiliary switch (screw terminals) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 2

Form & fit drawings GR pole with auxiliary switch (Combicon connector) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 3

Form & fit drawings GR 2 poles with auxiliary switch (screw terminals) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 4

Form & fit drawings GR 2 poles with auxiliary switch (Combicon connector) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 5

Form & fit drawings GR 3 poles with auxiliary switch (screw terminals) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 6

Form & fit drawings GR 3 poles with auxiliary switch (Combicon connector) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 7

Form & fit drawings GR 4 poles with auxiliary switch (screw terminals) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 8

Form & fit drawings GR 4 poles with auxiliary switch (Combicon connector) Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± 9

Form & fit drawings Busbar connection 0.330 [ 8.38 ] Busbar connection 0.266 [ 6.76 ] 0.090 [ 2.29 ] 0.794 [ 20.7 ] 0.470 [.94 ] 0.342 [ 8.69 ] 0.085 [ 2.6 ] Notes:. All dimensions are in inches [millimeters] 2. Tolerance ± 0.0 [0.25] unless otherwise specified 3. Angles ± Front panel clearance for circuitbreakers with an auxiliary switch (when panel is made of a conducting material) Front panel flush with breaker front surface minimal 8 mm distance required Auxiliary switch position 20

Circuit schematic 2

Technical specifications Codes At front of breaker the current rating and the delay type is shown with the following codes: Half shell marking SO DI DU DS DM DL AI AUS AS AM AL ASH AMH ALH DSH DMH DLH Delay Switch only DC instantaneous DC ultra short DC short DC medium DC long 50/60 Hz instantaneous 50/60 Hz ultra short 50/60 Hz short 50/60 Hz medium 50/60 Hz long 50/60 Hz short, high inrush 50/60 Hz medium, high inrush 50/60 Hz long, high inrush DC short, high inrush DC medium, high inrush DC long, high inrush 22

23

Ordering scheme GR - 60-24 - B - A - 2 - - 2 A - 2. 2. 3. 4. 5. 6. 7. 8. 9. 0.. 2. Series Poles Current Frequency Circuit Actuator Actuator Auxiliary/ Terminal Application Terminal Agency rating & delay colour alarm switch rating polarity approval. Series GR 2. Poles One 2 Two 3 Three 4 Four (4th pole for neutral break only) 3. Current rating (amperes) 220 0.200 250 0.500 40.000 45.500 420 2.000 425 2.500 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 460 6.000 470 7.000 480 8.000 490 9.000 60 0.000 6.000 62 2.000 63 3.000 65 5.000 66 6.000 67 7.000 68 8.000 620 20.000 625 25.000 630 30.000 632 32.000 635 35.000 640 40.000 650 50.000 660 60.000 663 63.000 Other ratings on request 4. Frequency & delay 03 0 2 4 6 Switch only DC instantaneous DC ultra short DC short DC medium DC long 20 2 22 24 26 50/60 Hz instantaneous 50/60 Hz ultra short 50/60 Hz short 50/60 Hz medium 50/60 Hz long 42 44 46 52 54 56 50/60 Hz short, high-inrush (max 50 A) 50/60 Hz medium, high-inrush (max 50 A) 50/60 Hz long, high-inrush (max 50 A) DC, short, hi-inrush (max 50 A) DC, medium, hi-inrush (max 50 A) DC, long, hi-inrush (max 50 A) 5. Circuit A B Switch only (no coil) 2 Series trip (current) 6. Actuator A S Handle, one per pole Mid-trip handle, one per pole 24

Ordering scheme 7. Actuator colour & legend Actuator colour White Black - 0 A C On-Off B D Dual 2 Legend colour Black White Other colours on request 8. Auxiliary/alarm switch 3 0 Without auxiliary switch S.P.D.T. screw terminal 2 S.P.D.T. screw terminal (gold contacts) 3 S.P.D.T. screw terminal with internal diode 4 S.P.D.T. screw terminal (gold contacts) with internal diode 5 Combicon connection 6 Combicon connection (gold contacts) 7 Combicon connection with internal diode 8 Combicon connection (gold contacts) with internal diode 9. Terminal Screw terminal 0. Application rating 2 D 3 0 VDC 240 VAC 440 VAC 4. Terminal polarity A Non-polarity sensitive 5 2. Agency approval 6 TUV certified 2 No agency approvals (configuration not tested A by external agency) For single pole DC breaker: Load terminal (+ connected with bottom terminal) 2 Line terminal (+ connected with top terminal) Special configurations, not covered by this ordering scheme, on request. Notes. When a breaker is mounted with the handle pointing downwards (e.g. ceiling mounting) the nominal value of the breaker will decrease with 0%. In this situation it is recommended to add 0 % to the rated current 2. Current rating in switch only circuit: - for 0.2 to 30 A select current code 630 - for 30 to 50 A select current code 650 - for 50 to 63 A select current code 663 3. On multi-pole breakers one auxiliary switch is supplied, mounted in the extreme left pole (front view) 4. 3 pole breaker required 5. Requires AC rating or multi-pole DC break (contacts in series) 6. TUV certified: only for actuator legend Dual and I-O Not for actuator legend ON-OFF, not for switch only circuit, not for DC more than 2 poles, not for delay curve 56; use code A instead (no agency approvals) 25

DS-GR circuit breakers-v4.0 January 205 Mors Smitt France SAS Tour Rosny 2, Avenue du Général de Gaulle, F - 938 Rosny-sous-Bois Cedex, FRANCE T +33 (0) 482 440, F +33 (0) 4855 900 E sales.msf@wabtec.com Mors Smitt Asia Ltd. # 807, Billion Trade Centre, 3 Hung To Road Kwun Tong, Kowloon, HONG KONG SAR T +852 2343 5555, F +852 2343 6555 E info@morssmitt.hk Mors Smitt B.V. Vrieslantlaan 6, 3526 AA Utrecht, NETHERLANDS T +3 (0)30 288 3, F +3 (0)30 289 886 E sales.msbv@wabtec.com Mors Smitt Technologies Inc. 00 Johnson Drive, Buffalo Grove, IL 60089-698, USA T + 847 777 6497, F + 847 520 2222 E salesmst@wabtec.com Mors Smitt UK Ltd. Graycar Business Park, Barton Turn, Burton under Needwood, Staffordshire, DE3 8EN, UK T +44 (0)283 722650 F +44 (0)283 72265 E sales.msuk@wabtec.com (c) Copyright 205 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Mors Smitt. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Mors Smitt reserves the right to alter the equipment specification and description outlined in this datasheet without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. Mors Smitt does not warrant that any of the information contained herein is complete, accurate, free from potential errors, or fit for any particular purpose. Mors Smitt does not accept any responsibility arising from any party s use of the information in this document.