ELE C TRO MAG N E T I C FLO W M E T E RS

Similar documents
dissolved oxygen transmitter

Dissolved Oxygen Transmitter

Dissolved Oxygen Transmitter

Wall-/Pipe-Mount Level Indicator

FLOMAT. Flowmeters. Electromagnetic Insertion Flowmeter: Series. Instrumentation for fluids

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Condition Monitoring Custom Products

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

LAUREL ELECTRONICS, INC.

Water temperature recommended range 5 45 C ( F) UV transmittance 254 nm, 1 cm) min. 45 %

SAN ANTONIO WATER SYSTEM CENTRAL WATER INTEGRATION PIPELINE TERMINUS TREATMENT FACILITY SAWS Job No SAWS Solicitation No.

FLOMAT Electromagnetic Insertion Flowmeter

SCALE & WEIGHT DISPLAYS

TELEDYNE HASTINGS INSTRUMENTS

Ultrasonic Level Transmitter and Sensor

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Modular Lube Lubrication Systems System Controls

Flow Measurement SITRANS F M

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

SITRANS F M. Transmitter MAG 5000/6000 4/33

Model KT 53 Cooling incubators with thermoelectric cooling

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Flow Measurement SITRANS F M

The measurements are stored in non-volatile memory, which retains data even when the power down.

MS2540 Current Loop Receiver with RS485 Communication

Model KBF 1020 Constant climate chambers with large temperature / humidity range

SITRANS F M. Transmitter MAG 5000/6000 4/33. Overview

Model KBF 115 Constant climate chambers with large temperature / humidity range

E3X-DA-S. Digital Fiber Sensors. Perfection Transcended! A Wealth of Advanced Functions for Easy and Reliable Application

SPACESCAN SERIES SS 02

XR47-24 Models 24 W/ F (43 W/ C)

Model KT 115 Cooling incubators with thermoelectric cooling

The full range of performance

N BTU/Hr Watt. N /8000 BTU/Hr. 1758/2344 Watt. N BTU/Hr Watt. Air Conditioners

Model KT 53 Refrigerated incubators with thermoelectric refrigeration

Model FP 240 Drying and heating chambers Classic.Line with forced convection and program functions

Modbus for SKF IMx and Analyst

TFR5 Room or outdoor temperature sensor. CombiTemp TM

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

TX33 Models 28 W/ F (50 W/ C) TX23 Models 14 W/ F (25 W/ C) TX38 Models 56 W/ F (100 W/ C) TX52 Models 83 W/ F (150 W/ C)

N43 N36 N28. Sealed Enclosure Cooling Air Conditioners

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Capacitance Level Measurement Electronic insert FEC 12

DATA SHEET MS 3780 MS3780_IT_EN_DS050REV01_IS

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

Meteor Product Catalogue

Scanning System S-2100

IMPAC Infrared Thermometers

XR47-24 Models 24 W/ F (43 W/ C)

Digital Temperature & Analog Sensor. Analog Input Port. Digital Port. Front

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

IP65. Specifications. White (4 300 K typical) Blue (470 nm) On-site or factory-programmable brightness. Black Silver Polished copper.

Humidity and Temperature Controllers (Product Code To ) DTH-966 with HYGROTX

Speed sensor MiniCoder GEL 2471

Model KT 170 Cooling incubators with thermoelectric cooling

Model KBF 720 Constant climate chambers with large temperature / humidity range

SC26 Magnetic Field Cancelling System

SM-1100/SM-1500/SM-1600 ROTARY ACTUATORS

GENESIS Indoor Air Conditioners

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

1900/25 Vibration Monitor

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

VOB - data over Video Overlay Box

T-Series Indoor/Outdoor Air Conditioners. Keeps its cool during peak heat loads and hot weather. Product Overview. T-Series A/C

Multifunction devices

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Magnetic Sensor - Incremental EHP

SAPLING WIRED SYSTEM

Pen and Multichannel Recorder: Digital Display

Micro-DCI 53ML5100 Manual Loader

CR BTU/Hr. 469 Watt. CR and 4000 BTU/Hr. 791 and 1172 Watts CR & 8000 BTU/Hr and 2344 Watts.

AF-300 E11 Adjustable Frequency Drive

ABB. Measure IT Uvisor System MFD Multi Flame Detector - Control Unit. Product Data Sheet (Rev. C)

Type AKS 4100/4100U Coaxial D14 version

Veilux User Manual SVEX-Q18 Intelligence Camera Set

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331i / DMP 333i LMP 331 i

DPR100 C/D Pen and Multichannel Recorder: Digital Display

Assembly. Front view. LEDs. Parametrization interface. Power Bus

User Manual for ICP DAS WISE Monitoring IoT Kit -Microsoft Azure IoT Starter Kit-

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

SECTION 8. Counters & Timers. Laurel Hecon Simpson Yokogawa (YCA)

T BTU/Hr Watts

Model KBF P 240 Humidity test chambers with ICH-compliant light source

Single Point Flow Monitor SW118 SW119

XR47-24 Models 24 W/ F (43 W/ C)

Operating instructions Electronic preset counter Type series 717

Model KMF 240 Constant climate chambers with expanded temperature / humidity range

-TECH DIGITAL. Explore The High DefinitionWorld. Website: Hot Line: [US] USER MANUAL

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

T3316 IP QAM Modulator User Manual

GENESIS Indoor Air Conditioners

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Transcription:

ELE C TRO MAG N E T I C FLO W M E T E RS

PROVEN AND RELIABLE FLOW MEASUREMENT 2 MJK MagFlux flow meters combine high accuracy, stability and low maintenance. Without moving parts, straight through flow sensor and self-cleaning electrodes there is virtually never any need for maintenance, there is no influence on the flow rate, and no pressure drop because of the flow sensor. MagFlux flow meters use a tested and approved sensing technology giving linear readings over a large range in closed pressurized pipe systems. www.mjk.com

L ARGE SELECTION OF S IZES AND M ATE RIALS Wafer Flange MagFlux is available in sizes from DN 3 to DN 1200 (1/8 to 48 ) with standard lay lengths and standard EN, ANSI, AS and JIS pipe connections. Model 7100 7200 7300 7400 7600 Mounting Flange Flange Wafer Wafer Flange Liner PTFE Hard rubber PTFE Hard rubber Soft rubber DN3 / 1 / 8 DN6 / ¼ DN8 / 5 / 16 DN10 / 3 / 8 DN15 / ½ DN20 / ¾ DN25 / 1 DN32 / 1¼ DN40 / 1½ DN50 / 2 DN65 / 2½ DN80 / 3 DN100 / 4 DN125 / 5 DN150 / 6 DN200 / 8 DN250 / 10 DN300 / 12 DN350 / 14 DN400 / 16 DN450 / 18 DN500 / 20 DN600 / 24 DN700 / 28 DN800 / 32 DN900 / 36 DN1000 / 40 DN1200 / 48 3

A B R E A KTHROUGH IN SEN S O R SET - U P S IMP LIC ITY 4 MJK s unique registration code for each sensor feeds all the necessary data into the meters electronics. In a matter of seconds the registration is completed, and the sensor characteristics and meter electronics are fully matched and ready to perform flow measurements. It is safer than other systems that require memory chips that get lost or damaged, or complicated procedures requiring external equipment that have potential for mistakes. MagFlux sensor direction is also configured in the electronics, so there is no way to install a sensor backwards. 66NQ10 REGISTRATION CODE

COMPREHENSIVE FLOW AND BATCH CONTROL FUNCTIONS 5 The MagFlux Converter has one 4-20 ma output, two relays for control and alarms, one digital input for batch or alarm reset, keypad start and stop of batch counters and reset of counters, totalizers and alarms. Pop-up windows alert the user about operational and alarm functions which are automatically logged and easily reset. Batching, batch counters, forward, reverse and net totalizers and non-resettable totalizers are all on-board and easy to configure. With its cell-phone like navigation, finding and managing these features is simple, but you can also password protect your settings.

BEST-IN-CLASS DATA LOGGING AND NETWORKING 6 MagFlux is the first to bring you an on-board electronic chart recorder that graphs flow rates and shows the date, time and flow rate for each data point. Behind the scene is a data logger that you set up with the data logging interval. To capture data for your permanent records simply use the USB connection in the MagFlux Display and the MJK Field Link freeware. This delivers not only the graphed data, but also a CSV data file (up to 20,000 data points) that you can open with MS Excel on your PC. For SCADA users MJK provides RS-485 communication with Modbus protocol along with registers, so that several MJK MagFlux flow meters can be operated seamlessly from a control room. MagFlux never gets out of date. The USB port also allows for uploading of new software, features and several different languages from a PC. Main Menu Specify Main Screen Factory Settings Data logger Password Set Sensor Name Converter Setup Display Setup Back Select OK

L OCATE AND C O NFIGUR E M AGF LUX Y OUR W AY MagFlux Converter and Display can stay locally with the flow sensor or can be installed remotely. A single Display can be used for set-up, viewing and data logging for one, two, three, or four Converters and Sensors in their own network to save space and cost. The Display can be up to 1000 m (3000 ft) from a Converter, allowing the Converter to be where the electrical and control connections are, while the Display can be where the operators are. The Converter can be separated from the sensor, too! This allows for even more flexibility to locate the Converter, where electrical connections are needed and out of danger from submersion, burial or other hazards. COMPACT MOUNTED 1 2 3 4 directly on the flow sensor (Compact Mounted). PANEL MOUNTING Display is mounted remotely from the Converter and Flow Sensor. Both the Display and Converter are together and mounted remotely from the Flow Sensorthe Flow Sensor. The Converter is mounted remote from the Sensor and the Display is Mounted remote from the Converter. Max. 50 m Max. 50 m WALL MOUNTING Max. 1.000 m Max. 1.000 m 7 Wall mounting or panel mounting is possible for all MagFlux electronic units. 5 One remote mounted Display oper- ates two Converters and flow sensors that are mounted together. Max. 1.000 m Max. 1.000 m

MagFlux Sensor Mounting Materials Flange or wafer Housing: Painted carbon or stainless steel Liner: Hard rubber, soft rubber or PTFE Electrode: Stainless steel 1.4571 (AISI 316). On order Hastelloy, titanium or platinum Built-in grounding electrode DN 50 Accuracy Better than ± 0,25% Temperature Liquid: -20 to +150 C / -5 to +302 F, depending of type. Surroundings: -20 to +60 C / -5 to +140 F (converter mounted on sensor) -20 to +80 C /14 to +176 F (converter remote mounted) Enclosure IP 67 (with gel potting IP 68) / NEMA 4X (with gel potting NEMA 6P) 8 MagFlux Converter Accuracy ± 0,1% of measurement (system accuracy better than ± 0,25 %) Input Analog output From MagFlux sensor One active 4-20 ma, galvanic isolated (max. 800 ) Digital output One voltage-free, electromechanical relay (max. 50 V DC / 1 A) One optically isolated (max. 50 V AC / V DC / 120 ma) Digital input Communication Interface Power supply Power consumption Cabinet materials Enclosure rating One digital input. Max. 30 V DC Modbus RTU-mode, 9600 baud, 2-wire RS 485, slave-mode RS 485 for connection to Display Unit or PLC. 24 V AC / DC, 50 / 60 Hz ± 10 % or 230 / 115 V AC, 50 / 60 Hz ± 10 % Max. 10 W Polycarbonate, glass reinforced IP 67 / NEMA 4X GB MagFlux brochure 0708 MJK Automation A/S Byageren 7 2850 Nærum Denmark Tel.: +45 45 56 06 56 Fax: +45 45 56 06 46 www.mjk.dk mjk@mjk.dk MJK Automation AS Prins Chr.Augusts Plass 1 1530 Moss Norway Tel.: +47 69 20 60 70 Fax: +47 69 20 60 71 www.mjk.no mjk@mjk.no MJK Automation AB Nytorget 4 S-66123 Säffle Sweden Tel.: +46 53 31 77 50 Fax: +46 53 31 38 11 www.mjk.se kontoret@mjk.se MJK Automation B.V. Hoofdweg 667 A 2131 BB Hoofddorp Holland Tel.: +31 0251-672171 Fax: +31 0251-671951 www.mjk.com mjknl@mjk.com MJK Automation P/L Unit 8/69 Acacia Road Ferntree Gully 3156 Victoria Australia Ph: + 61 3 9758 8533 Fax: + 61 3 9758 8633 www.mjk.com mjkaus@mjk.com MJK North America Inc. 37 Sherwood Terrace, #126 Lake Bluff IL 60044 USA Toll Free: +01 877-655-5465 +01 (877-MJK-LINK) Local: +01 847-482-8655 Fax: +01 847-482-8654 www.mjk.com mjkusa@mjk.cmm