TENDER SUMMARY. Tender Title:

Similar documents
Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

Micro duct Cable with HDPE Sheath for Installation by Blowing

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Revision No. 4 Page No. Page 1 of 7

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

SPECIFICATION. Optical Fiber Cable

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

TECHNICAL SPECIFICATION

Detailed Specifications & Technical Data

OPTICAL FIBRE CABLE NETWORK 2004/1

LD Series High Performance Loose Tube Fiberoptic Cables

Number of Fiber 12 Core 24 Core 48 Core. Part Number

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

1. General. 1. Scope. 2. Quality Assurance

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

Number of Fiber 6 Core 12 Core 24 Core 48 Core

Number of Fiber 6 Core 12 Core. Part Number

ETSI ES V1.1.1 ( )

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

Ø 1000 * 588 mm 50 kg

FREEDM Loose Tube Interlocking Armored Cables

Mining and Petrochemical Fiber Optic Cables

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

HERA RETICULATION FIBRE CABLE PRODUCT REQUIREMENTS

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

STANDARD FOR MULTI-DWELLING UNIT (MDU) OPTICAL FIBER CABLE. Publication S First Edition - June 2012

SOLO ADSS Short-Span Cables, Fibers

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Material Description Quantity UOM

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

TECHNICAL SPECIFICATION

SPECIFICATION. Spec No : VSS-1402-CS603B

for FOSTEC INC. 1/ 15

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Cisco ONS Exposed Faceplate Mux/Demux 48-Channel Extended Bandwidth Patch Panel and Splitter Coupler Module

Product Catalogue. Fibre Optic Cable

INDUSTRY SOLUTIONS: MINING

Empowering businesses through innovative network solutions.

CC-Link IE Controller Network Compatible. CC-Link IE Controller Network Recommended Network Wiring Parts Test Specifications

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

40G SWDM4 MSA Technical Specifications Optical Specifications

The BRU-SF10 supports single mode optical fiber cable ensuring 2,000m transmission at maximum.

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

100G-FR and 100G-LR Technical Specifications

Mar11 Rev E

LIIN-25 FO Pigtail FC (0.9mm)

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

OPTICAL CABLE FIBER-LAN INDOOR

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

A Comparison of Dry Versus Gel Filled Optical Cables

400G-FR4 Technical Specification

3M 8900 Single-mode SC Crimplok Connector

40G SWDM4 MSA Technical Specifications Optical Specifications

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

Specification of Fusion Splice Loss - FIA TSD Mike Gilmore FIA Technical Director

We design, build, and manage web-scale networks for the needs of tomorrow. System Integration SERVICES

SECTION 4 TABLE OF CONTENTS

e-enterable Fiber Optic Splice Closure (Re-Enterable Aerial Closure for Access Service)

Industry solutions: Broadcast

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

A IR-BL O W N SOLUTION C O D. M I C R O C O D. M I C R O D U C T

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

HI-DEX PRODUCT SET DATASHEET

EVLA Fiber Selection Critical Design Review

Gear up for the future.

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Hardware Specifications

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

CATEGORY 6A CABLING SOLUTIONS

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

FIBRE OPTIC CABLE SOLUTIONS

PM Couplers (Polarization Maintaining Couplers)

SPECIFICATION FOR FIBER OPTIC SPLICE CLOSURE

How to Speak Fiber Geek Article 4: Single-Mode Optical Fiber Geometries

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

Transcription:

TENDER SUMMARY Tender Title: Tender Ref: Closing Date: OPEN TENDER FOR THE SUPPLY OF FIBER OPTIC CABLE 384 CORE LOOSE TUBE ( FOC 384C ) FOR TELEKOM MALAYSIA BERHAD ( TM ) LPM/2018/T/02/FOC 384C 23 February 2018 (Friday) 1. The purpose of this tender is to realise the aspiration of the LOBs and ultimately TM, it is deemed necessary to have a new high capacity fiber optic cable (FOC) deployed in the network. Currently the cable optic range between 4 cores, 8 cores, 12 cores, 24 cores, 32 cores, 48 cores, 96 cores, 144 cores and 192 cores of various configurations and specific usage characteristic such as underground, overhead and armoured. 2. In order to support the aspiration of 20,20,3,4,6 initiatives the new emerging 384 core FOC is seen as a variable solution to meet the new demands. This 384 core fiber will enable ND to provide broader expansion, fastere deployment with a lover overall cost in order to fulfil the targets set by the LOBs and ultimately realise the aspirations set forth by TM s top management. 3. This tender will support the delivery of high rise building fiberization, Wifi AP establishment, Mobile Unifi and TM Global Next Generation Backhaul (NGBH) in order to achieve of following: a) To increase of bandwidth and service offerings as well as bigger coverage areas. b) To reduce operational cost due to requirement for civil works and installation cost. 4. The scope of this tender are as follow:- a) Supply of FOC 384 core loose tube cable. b) Warranty period for twelve (12) months upon the signing of Delivery Order (DO). c) Training. 5. Tenderer is required to fully comply with the clauses marked as Critical (CRQ) Clause in the Technical Specifications failing which, the Tenderer shall be disqualified from the tender exercise and their tender submission shall be rejected. The list of CRQ clauses are as below: No. Clause No 1. B.3.2 The Fibre Optic Cable shall be of 384 core loose tube type with outside diameter less than 20 mm. The Tenderer shall submit supporting evidence in tender submission. 2. B.4.1.2.1 The fibre core attribute shall be in accordance with ITU-T G.652D and the cable attribute requirement as tabulated in Table 1. The Tenderer shall submit supporting evidence (such as but not limiting to datasheet of fibre core or brochure) in the tender submission.

No. Clause No FIBRE ATTRIBUTES Transmission wavelength Mode Field Diameter (MFD) Cladding Diameter Core Concentricity Error Cladding Noncircularity Cut-off Wavelength Macro bend loss Proof Stress Chromatic Dispersion CABLE ATTRIBUTES Attenuation coefficient Polarization Mode Dispersion (PMD) 1310nm, 1490nm, 1550nm and 1625 8.6 m to 9.5 m with ± 0.6 m at 1310nm wavelength 125 m± 1 m 0.6 m (maximum) 1.0% (maximum) a) Cable Cut-off Wavelength ( cc) shall be maximum 1260nm b) Fibre Cut-off Wavelength ( c) shall be maximum 1250nm Parameter Radius (mm) 30 Value Number of turns 100 Max. at 1625nm (db) 0.1dB 0.69Gpa (minimum) a) Zero Dispersion Slope (S 0max) shall be less than and equal to 0.092ps/nm 2.km b) Zero Dispersion Wavelength shall range from 1300nm (λ 0min) to 1324nm (λ 0max) Maximum from 1310nm to 1625nm is 0.35 db/km Maximum at 1550nm is 0.22 db/km 0.2ps/ km (maximum) Table 1: Fibre Attributes 3. B.4.2.1.2 The fibre optic cable shall be constructed as per Table 2 below. The Tenderer shall submit cross-sectional diagram and/or any supporting evidence in tender submission. REQUIREMENT Fibre Core Counts in Cable Number of tubes Fibre Core Counts in Tube Filler PARAMETER 384 cores Six (6) tubes for inner layer Ten (10) tubes for outer layer 24 cores per tube 2 (outer layer) Table 2: Cable design and construction requirement

No. Clause No 4. B.4.2.1.12 The ripcord with minimum 150N breaking load shall be applied under the cable jacket for the purpose of stripping the jacket without damaging the cable core. The Tenderer shall submit supporting evidence in the tender submission. 5. B.4.2.2.1 The colour identification of individual fibre core shall be configured in the following sequence as in Table 3. The tenderer shall submit supporting evidence (such as but not limiting to product brochure or datasheet) in the tender submission. FIBRE REFF. COLOUR COLOUR NUMBER CODE 1 Blue RAL 5015 2 Yellow RAL 1021 3 Green RAL 6018 4 Red RAL 3000 5 Violet RAL 4005 6 Brown RAL 8003 7 Pink RAL 3015 8 Grey RAL 7035 9 Black RAL 9004 10 Orange RAL 2008 11 White RAL 9001 12 Aqua RAL 6027 13 Blue with black tracer RAL 5015 14 Yellow with black tracer RAL 1021 15 Green with black tracer RAL 6018 16 Red with black tracer RAL 3000 17 Violet with black tracer RAL 4005 18 Brown with black tracer RAL 8003 19 Pink with black tracer RAL 3015 20 Grey with black tracer RAL 7035 21 Neutral with black tracer RAL 9001 22 Orange with black tracer RAL 2008 23 White with black tracer RAL 9001 24 Aqua with black tracer RAL 6027 Note: The tracer at the fibres shall be black (RAL 9004) colour. Table 1: Fibre Core Colour and Configuration 6. B.4.2.3.1 The colour identification of individual buffer tube shall be configured in the following sequence as in Table 4. The tenderer shall submit supporting evidence (such as product brochure) in the tender submission. LAYER Inner Layer TUBE NUMBER TUBE COLOUR REFF. CODE 1 Blue with black stripes RAL 5015 2 Yellow with black stripes RAL 1021

No. Clause No LAYER Inner Layer Outer Layer TUBE NUMBER TUBE COLOUR REFF. CODE 3 Green with black stripes RAL 6018 4 Red with black stripes RAL 3000 5 Violet with black stripes RAL 4005 6 Brown with black stripes RAL 8003 7 Blue RAL 5015 8 Yellow RAL 1021 9 Green RAL 6018 10 Red RAL 3000 11 Violet RAL 4005 12 Brown RAL 8003 13 Pink RAL 3015 14 Grey RAL 7035 15 Black RAL 9004 16 Orange RAL 2008 Note: The stripe at the inner layer buffer tube shall be black (RAL 9004) colour Table 2: Buffer Tube Colours and Configuration

No. Clause No 7. B.5.1 The cable shall subject to the following mechanical and environmental tests and meet the expected outcome to gauge its reliability and durability. The Tenderer shall submit supporting evidence (such as but not limiting to product brochure or data sheet) in the tender submission. NO TEST TYPE TEST METHOD 1 Tensile Test Method E1 2 Crush Test Method E3 3 Cable Bend Test Method E11 4 Impact Test Method E4 5 Repeated Bend Test Method E6 6 Torsion Test Method E7 7 Temperature Cycle Test Method F1 TEST CONDITION Load: 2000N Length under tension: 100m Load: 3000N Mandrel/plate: 25mm mandrel Duration: 10min Mandrel Diameter: 20 x Cable OD No. of turn: 5 No. of cycle: 3 Impact energy: 5J with striking surface radius of 10mm or 20J with striking surface radius of 300mm Striking surface radius: 10 or 300mm No. of impact: 1 times at 3 different places ( > 500 mm apart) Load: 100N Bending radius: 20 x Cable OD No. of cycles: 35 Twist: +/- 180 degree No. of Cycle: 5 Load: 100N Temperature range: -30 C to 70 C No of cycle: 2 REQUIREMENT a) Change in attenuation 0.05 db/km b) No residual elongation. c) No damage to sheath, cable element b) No damage to sheath, cable element b) No damage to sheath, cable element /km

NO 8 9 TEST TYPE Water Penetration Test Compound Flow Test 10 Cable Retention TEST METHOD Method F5 Method IEC 60794-1-2 Test reference GR-771- CORE TEST CONDITION Water height: 1m Sample length: 3m Test period: 24 hour Length of cable under test 300mm Remove outer sheath at 130mm Remove all the non-intrinsic cable elements 80mm Temperature: 70±5 C for 24 hours Apply 10kg load at 1 meter length of the cable from the cable clamp (FRP holder + cable clamp termination hardware) REQUIREMENT No leakage at end of 3m length No dripping of flooding and filling gel after 24 hours. No cable or others cable elements movement during and after test 8. B.8.1 The proposed FOC 384 core shall have successfully implemented and still in operation with minimum 5000 km in total length. Tenderer shall provide supporting evidence as per appendix B and submit upon tender submission. 6. The Tenderer shall deposit a sum of RINGGIT MALAYSIA Fifty Thousand Only (RM50,000.00) as a Tender Deposit and to be submitted in the Tender Proposal during Tender Closing Date.