Main House Technical Specifications

Similar documents
DEREHAM MEMORIAL HALL

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Technical Specification Pavilion Dance

Technical Specifications Updated 01/10/2017. Stage

Main House Technical Specification

CHELSEA THEATRE. Technical Specifications

TECHNICAL SPECIFICATIONS

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

INFORMATION FOR VISITING COMPANIES

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

Technical Data Sheet

Dr JOHN GALLAGHER CONCERT CHAMBER

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Technical Specification

2017 TECHNICAL SPECIFICATIONS

Technical Specification for the Alley Theatre, Strabane

Technical Pack. Attenborough Arts Centre

Technical Specifications

Stage. Get In & Parking

Technical Specification

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

Technical Specification

Capacity: 60 2 Roxburgh Place, EH8 9SU. Assembly Roxy - Downstairs

HIRE AND TECHNICAL INFORMATION

Cornerstone Technical Specifications 2018 / V1

Lighthouse Theatre Technical Specification

TECHNICAL SPECIFICATIONS

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Services and Specification

Rhodes Arts Complex Bishops Stortford. Technical Specifications

The Haymarket Basingstoke Technical Specifications

Dugdale Centre Technical Specification

Matt Dann Cultural Centre

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Technical Specifications

Technical Specifications

Sandusky State Theatre Technical Specifications

Technical Specifications Nov 2016

Pleasance London Main House Visiting Company Information Pack May 2017

Marjorie S. Deane Little Theater

Technical Director of Production Andrew Quick Ext 252

Arlington Arts Tech Spec 2018

Technical Information

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

ISLAND HALL TECHNICAL INFORMATION

RPAC REDLANDS PERFORMING ARTS CENTRE

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

UNIVERSITY CONCERT HALL. Technical Specification

VISY THEATRE TECHNICAL SPECIFICATIONS Version 2.6 3/7/2013. Auditorium Seating. Page 1 of 4 STAGE CONFIGURATIONS

Technical specifications Main theatre. Sound

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

New Theatre Royal Lincoln Technical Information

JERWOOD VANBRUGH THEATRE

Arcadia Performing Arts Center Technical Specifications and Information

TECHNICAL SPECIFICATION

ROSE THEATRE BASEMENT

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Technical Specification (Studio Theatre)

Technical Specification (Studio Theatre)

Theatre Technical Specifications

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

Technical Information

The Mannie Manim Technical Specifications

Technical Specification Ardhowen Theatre

ROSE THEATRE MAIN THEATRE

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Shouson Theatre Venue Specifications (updated Jan 2017)

Facility Information

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Technical Pack. Embrace Arts at the RA Centre

Technical Specifications. Taylor Little Theater

Where performance matters

Technical Specification

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Venue details. Stage Dimensions. Stage section Width Depth Height to Grid. Main Stage 8.8m (ex. wings) 7.32m 8.1m Baptistery 7.19m 6.4m 8.

The Lights Technical Guide June 2017

Visy Theatre technical information and general specifications 2019

Technical Specification (October 2017 v4.2) Theatre and Technical Manager: Phil Pattie

Theatre Technical Specification

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Darlington Hippodrome Technical Specification

Technical Specifications

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

Hirers Technical Information Pack

Barney Simon Theatre Technical Specifications

DRAÍOCHT Technical Specification: MAIN SPACE

Technical Specifications

Main Stage Technical Specs - Hall #2

The Georgian Theatre Royal Technical Information For Visiting Companies

Technical Information

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Transcription:

Main House Technical Specifications Technicians Senior Technician - Stephen Payne Technician - Drew White Technician - Joanne Marshall Arena Theatre Wulfruna Street Wolverhampton WV1 1SE Tel: 01902 321 321 Contact Details Box Office - 01902 321 321 Marketing - 01902 322 646 Senior Technician - 01902 322 507 steve.payne@wlv.ac.uk Technicians - 01902 322 647 drew.white@wlv.ac.uk jo.marshall@wlv.ac.uk ARENA TECH SPEC 1

Get In The theatre Get In has ramped access direct to the stage area and is positioned at the far left hand side of the executive staff car park. Maximum width is 2.5 Metres. Please note that the entrance to the executive staff car park has a height restricted entrance. Maximum height is 3.2 Metres. Maximum width is 3 Metres. Dressing Rooms Dressing room 1-6 persons Dressing room 2-8 persons Dressing room 3-15 persons Dressing room 4-15 persons (Accessible) Dressing room 5-6 persons (Accessible) N.B. - If additional space is required, please contact the Senior Technician in advance. Dressing Room Facilities Security Wash Facilities WC Facilities Power Fittings Communications Green Room Wheelchair users Smoking Personnel Electrical Items Wi-fi Dressing rooms are locked every evening and keys are available on request. All dressing rooms have hand basins and showers. All dressing rooms have toilets. All dressing rooms have 13amp power outlets. All dressing rooms have mirrors with lighting surrounds, work surfaces, chairs and costume rails (No rail in Dressing Room 2). All dressing rooms have show relay and paging. Green room is situated FOH accessible, via pass door in main dressing room corridor. Dressing rooms 4 and 5 are fully accessible via a lift. No smoking is permitted anywhere on the premises with the exception of as part of a performance (agreed with technical staff). This includes E Cigarettes. A Maximum of 50 persons allowed in the backstage area, including venue staff, chaperones and performers. Please ensure all electrical items used in the venue are P.A.T tested and show an dated label. Free Wi-fi is available, please ask at the box office. ARENA TECH SPEC 2

Stage Dimensions Setting Line Stage Width Stage Depth from Setting Line Grid Height Height under Stage Right Balcony Height under Stage Left Balcony Stage Right Wing Width Stage Left Wing Width Up Stage Crossover 1300mm from Row A 9500mm 8000mm 4670mm 2200mm 2200mm 1270mm 1900mm (upstage of prompt desk) 1520mm (downstage of prompt desk) 2900mm Stage Equipment 8 15Kg Stage weights 3 Black masking flats 1200mm x 2000mm (w x h) 8 Stage braces of varying lengths 1 12 rung Zarge 1 7 rung Zarge step ladders 1 5 rung Zarge step ladders 1 Genie GR-12 Runabout VPP (Licensed users only - category 3A) Tabs and Cloths White cyclorama (projection screen on tab track) Non-Removable. Black tabs masking all wing entrances. Black tabs to cover the white cyclorama. Black half tabs with pulley operation stage right. 4160mm from the setting line. Additional Stage Information a) Black wooden floor b) CCTV monitoring system with monitors located in control room, scene dock, all dressing rooms, green room and in the prompt desk stage left. c) Black dance floor is available upon request (dance companies only). 8000mm x 8000mm in 2000mm strips N.B. - Due to the style and nature of the venue, screwing/ penetrating into the stage is not permitted. No set is to be placed on the in-house dance floor. ARENA TECH SPEC 3

Lighting Equipment Dimming and Control 02 ETC Sensor3 Digital Dimmer Racks 171 3Kw Dimmers 24 3Kw hard power terminating in 15a sockets 01 ETC GiO (2048 outputs) 02 Monitors terminating in DVI-I 01 Net 3, 4 port DMX gateway (permanent installation) N.B. - Patched to 04 DMX Splitters, controlling up to 4 universes located in the control room. Lighting Equipment Generic Fixtures 07 Strand quartet Fresnel 650w 11 Strand quartet PC 650w 14 Strand Cantata Fresnel 1200w 13 Strand Cantata PC 1200w 10 Source 4 15/30 zoom 750w 20 Source 4 25/50 zoom 750w 18 Source 4 Junior 25/50 zoom 500w 15 Parcan CP62 1000w 06 ADB ACP 1001 Cyc flood 1250w Lighting Equipment Houselights GDS DMX controlled LED houselights, controllable in the following zones: Address 500 Address 501 Address 502 Address 503 Address 504 Address 505 Main Block Cross Aisle Rear Block House Left Balcony House Right Balcony Over Stage ARENA TECH SPEC 4

Effects and Accessories 01 Jem Compact Pro Hazer 02 Doughty tank traps 01 14 Mirror Ball 01 Mirror Ball Rotator 01 ADB 500w Cyc flood 01 63a 3ø (phase) rubber box with the following outputs: 06 16a 1ø (single phase) sockets 03 63a 1ø (single phase) sockets Additional Lighting Information a) The lighting desk (ETC GiO) can be replaced for an ETC ION (2048) upon request. b) Lighting control is located at the rear of the auditorium and room has double glazed windows. It is shared with sound control. (This is not sound proof) c) The Arena holds and extensive range of Lee lighting filters and Rosco R119 & R132 Frost. d) One 63a 3ø (phase) socket located in the upstage cross over. e) The Arena carries a limited stock of Gobo s. f) The Arena holds size A & B Gobo holders for our Source 4 Zoom Profiles. ARENA TECH SPEC 5

Sound Equipment 03 d&b E12-D (Permanent FOH Installation, Left, Right and Centre) 02 d&b E15-X Subs (Permanent FOH Installation) 03 d&b E6 Delays (Permanent FOH Installation) 05 d&b E8 05 d&b D6 Digital Amplifiers 01 Yamaha CL5 Digital Mixing Console 01 Ro8-D Digital Output Rack (Permanent Installation) 01 Ri8-D Input Rack (Permanent Installation) 01 Rio1608-D Digital Stage Box 01 Rio3224-D Digital Stage Box 02 Tascam Mini Disc/CD Player 04 Sennheiser G3 EW300 Radio Microphone (Transmitters and Receivers) 07 Shure SM57 Microphone 06 Shure SM58 Microphone 01 Pulse PM580s Microphone 02 Audio Technica AT4040 Microphone 02 AKG C451b Microphone 03 AKG C1000 Microphone 01 AKG Groove Pack Perception Live Drum Mic Set: 01 AKG P2 03 AKG P4 02 AKG P17 04 E/V ND468 Microphone 08 Tall boom arm stands 07 Short boom arm stands 04 Straight stands 06 Table top stands 04 Mackie SRM450 Active Speakers 01 8way Headphone Amp 02 8way DI Boxes 04 Single DI Boxes Projector/ A.V 01 Panasonic PT-RZ970 Laser Projector - controllable by ArtNet (Permanent Installation) 01 Blu-Ray Player 01 Kramer VP-729 Scaler/Switcher 01 Kramer SID-X2N Step-in Commander 02 15 Macbook Pro with Qlab 3 ARENA TECH SPEC 6

Additional Sound Information a) Sound Control room is located at the rear of the auditorium. It has double glazed windows and is shared with lighting. One window in front of the sound control position can be opened. b) The Sound desk may be moved into the auditorium off to the far house left side. c) FOH speakers are wired into a patchable speakon rack located in the control room. d) In-house Radio Microphones have both Handhelds and Lavalieres available. They are tuned to a venue specific licensed frequency. Please see below: - 526.200-526.700-527.350-528.150 Accessibility 01 Sennheiser mobile connect unit (compatible with any ios or Smartphone) 01 Audio Description workstation (Microphone, sound desk & dedicated show relay) 05 ipod touches dedicated to use with mobile connect 01 Sennheiser infrared audio enhancing system (permanently installed to show relay) 06 Sennheiser EZT 3011 Induction Neck Loop 06 Sennheiser HDI 830 IR headphones N.B. - If you require any further information on the Induction Loop or Audio Description please contact the Senior Technician. ARENA TECH SPEC 7

Health and Safety As part of our health and safety policy, an Arena Theatre technician will conduct a safety briefing with all staff working on the production before the Get In commences. These will take place on shift changes and will be reiterated on the get out/ strike. The aim of the briefing is to introduce the key members of our technical staff, inform your staff of all evacuation procedures and draw their attention to any other possible hazards and policies that may be relevant to the production. This briefing is also an opportunity to introduce your staff to the house crew and discuss the on the schedule for the day. A further briefing should take place with all members of the company on there arrival. This should take place in the auditorium and all technical work on stage should stop at this point for the briefing to take place. Arena Theatre technical staff will provide information on in house Health & Safety Policies as required (Copies available on request). Arena Theatre Health & Safety Policies must be followed at all times. Special consideration must be given to Working at Height, Electrical Safety and Rigging/Suspended Equipment. It is the responsibility of the visiting company to ensure all equipment and the items bought into The Arena are in a safe and suitable condition for use in a professional environment. This means all rigging equipment bought into the venue should have a SWL marked on it and all electrical equipment should hold a valid P.A.T Test. Any equipment that does not have the above may be deemed unsafe and may not be used. Arena Theatre technicians have the final say over all matters relating to Health & Safety, and have the right to refuse use of any equipment or other items they deem to be unsafe. ARENA TECH SPEC 8