Nondestructive Testing Device for Tie Bar Placement Accuracy

Similar documents
Concept of Operations (CONOPS)

Sample: A small part of a lot or sublot which represents the whole. A sample may be made up of one or more increments or test portions.

Aerial Cable Installation Best Practices

* This configuration has been updated to a 64K memory with a 32K-32K logical core split.

Reducing Waste in a Converting Operation Timothy W. Rye P /F

Take Control of Quality Assurance

(Skip to step 11 if you are already familiar with connecting to the Tribot)

PROFOMETER PM-6 ADVANCED COVER METERS. 60 Years of Innovation. Made in Switzerland Design Patent Pending 4H H H H32-01 U-BARS

ECE 480. Pre-Proposal 1/27/2014 Ballistic Chronograph

THE OPERATION OF A CATHODE RAY TUBE

Broken Wires Diagnosis Method Numerical Simulation Based on Smart Cable Structure

EDDY CURRENT IMAGE PROCESSING FOR CRACK SIZE CHARACTERIZATION

THE OPERATION OF A CATHODE RAY TUBE

RESEARCH UPDATE. FIELD EVALUATION OF 3MfM SCOTCH-LANE WET REFLECTIVE REMOVABLE TAPE SERIES 750 (Final Report)

ULTRA-TRAC APL INSTRUCTION MANUAL. Read and understand instructions before use. Patented. 851 Transport Drive Valparaiso, IN

INTRODUCTION. The sketch above shows the initial concept for the HRSG Internal Access Tool. 535 Old Frankstown Road Pittsburgh, PA

Smart Traffic Control System Using Image Processing

DIGITAL MAGNETIC IMAGING OF STEEL CORD CONVEYOR BELTS MJ Alport, JF Basson and T Padayachee

Quality Control. Chapter 23

Microincrements XFC. Application Note DK XFC technology microincrements. Technical background CHA CHB. 2fold.

Paranormal Devices Built By Bill Chappell. For some weird reason people think I only build things that talk!

Microincrements IP67-related solutions

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

Computer Coordination With Popular Music: A New Research Agenda 1

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

A Real Word Case Study E- Trap by Bag End Ovasen Studios, New York City

CS-200 SOLAR PORTABLE TRAFFIC SIGNAL SYSTEM FIELD MANUAL. 134 Ogilvie Avenue, Echuca 3564 (03)

Innovative Rotary Encoders Deliver Durability and Precision without Tradeoffs. By: Jeff Smoot, CUI Inc

E X P E R I M E N T 1

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

EDDYCHEK 5. Innovative eddy current testing for quality and process control. Touchscreen. Networking. All major applications.

In total 2 project plans are submitted. Deadline for Plan 1 is on at 23:59. The plan must contain the following information:

EddyCation - the All-Digital Eddy Current Tool for Education and Innovation

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

Toward a Computationally-Enhanced Acoustic Grand Piano

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

Instromet Weather Systems Ltd

The all-in-one solution for rebar assessment and corrosion analysis

L. Sound Systems. Record Players

Data flow architecture for high-speed optical processors

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

Detection and demodulation of non-cooperative burst signal Feng Yue 1, Wu Guangzhi 1, Tao Min 1

SIMATIC FS400 light curtains and arrays

e'a&- A Fiber Optic Wind Vane: A Conceptual View (U)

NDT Supply.com P.O. BOX 7350 Shawnee Mission, KS USA

CALDECOTT FOURTH BORE

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Advanced Subsidiary Level and Advanced Level

Time Domain Simulations

Exploratory Analysis of Operational Parameters of Controls

APPLICATION OF PHASED ARRAY ULTRASONIC TEST EQUIPMENT TO THE QUALIFICATION OF RAILWAY COMPONENTS

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

Quantify. The Subjective. PQM: A New Quantitative Tool for Evaluating Display Design Options

SECTION 5900 TRAFFIC SIGNALS CITY OF LEE S SUMMIT, MISSOURI DESIGN CRITERIA

Evaluation of Construction Zone Pavement Marking Materials

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

CONVOLUTIONAL CODING

THE EFFECT OF PERFORMANCE STAGES ON SUBWOOFER POLAR AND FREQUENCY RESPONSES

Application Note Using Buffered Outputs and Patch Panels with the SETPOINT Machinery Protection System

Ultrasonic Testing adapts to meet the needs of the Automotive Tube Industry

The Syscal family of resistivity meters. Designed for the surveys you do.

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Figure 2: components reduce board area by 57% over 0201 components, which themselves reduced board area by 66% over 0402 types (source Murata).

TruePlate Structural Plate

FEASIBILITY STUDY OF USING EFLAWS ON QUALIFICATION OF NUCLEAR SPENT FUEL DISPOSAL CANISTER INSPECTION

High Resolution Concrete Imaging

J R Sky, Inc. Cross-Modulation Distortion Analyzer

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Indoor/Outdoor Security System with Quad Monitor User s Manual

Operating Instructions

Torsional vibration analysis in ArtemiS SUITE 1

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

ENC - LKE51 - L I B

Procedures for conducting User QA on the scanner

Implementation of LED Roadway Lighting

Assembling and Mounting the Presentation Display, Speakers, Speaker Screens, and Table Door

Cover Sheet. Scanning Report of Flexible Riser Pipe Section EVI /7/2005. Inspection Report

Skip Length and Inter-Starvation Distance as a Combined Metric to Assess the Quality of Transmitted Video

PCM ENCODING PREPARATION... 2 PCM the PCM ENCODER module... 4

SC24 Magnetic Field Cancelling System

THE INFLUENCE OF AN AMBIENT MAGNETIC FIELD ON MAGNETIC TAPE RECORDERS

STB Front Panel User s Guide

White Paper JBL s LSR Principle, RMC (Room Mode Correction) and the Monitoring Environment by John Eargle. Introduction and Background:

SC24 Magnetic Field Cancelling System

THE AMBER COMPUTER VDU PROJECT.

Important Safety & Warning Precautions

Copyright 2018 Geophysical Survey Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form

BOLLARDS. Complete range of parking bollards. (800)

INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

Practice, Practice, Practice Using Prototek Digital Receivers

MODE FIELD DIAMETER AND EFFECTIVE AREA MEASUREMENT OF DISPERSION COMPENSATION OPTICAL DEVICES

Copyright 2008 Society of Manufacturing Engineers. FUNDAMENTALS OF TOOL DESIGN Progressive Die Design

Advanced Photon Source - Upgrades and Improvements

Starling Tab-Tension 2 Series

The software concept. Try yourself and experience how your processes are significantly simplified. You need. weqube.

DMC550 Technical Reference

How To Stretch Customer Imagination With Digital Signage

OPERATIVE GUIDE P.I.T. PILE INTEGRITY TEST

An Improvised Two-Dimensional Laser Surface Scanner for Diagnosis of Rf Thermionic Electron Gun Problems

Transcription:

Nondestructive Testing Device for Tie Bar Placement Accuracy Stanley E. Young Kansas Department of Transportation 2300 Van Buren Street Topeka, KS 66611 young@ksdot.org Nathan W. Holle Department of Electrical and Computer Engineering Kansas State University 2061 Rathbone Hall Manhattan, KS 66506 nholle@ksu.edu ABSTRACT The Kansas Department of Transportation (KDOT) in cooperation with Kansas State University (KSU) and the American Concrete Pavers Association (ACPA) is developing an instrument capable of assessing tie bar placement accuracy suitable for use in a paving environment. The instrument is now in its fourth prototype. The third-generation prototype used a single magnetic sensor and was capable of assessing depth accuracy at a rate of approximately two miles of construction joint per hour on projects during the 2004 construction season. KDOT is developing a new placement specification appropriate for this type of sensing technology. The fourth-generation prototype will possess multi-sensor capability to assess lateral placement as well as depth accuracy. Due to cooperation with the ACPA, this instrument is targeted to be integrated into paving equipment for real-time quality control. This paper reviews the basic sensing principles of magnetic tomography and how it can be successfully integrated with microprocessors and communications into a nondestructive instrument for use in a concrete construction environment. Key words: magnetic tomography nondestructive testing tie bar Proceedings of the 2005 Mid-Continent Transportation Research Symposium, Ames, Iowa, August 2005. 2005 by Iowa State University. The contents of this paper reflect the views of the author(s), who are responsible for the facts and accuracy of the information presented herein.

PROBLEM STATEMENT The Kansas Department of Transportation (KDOT), in cooperation with Kansas State University (KSU) and Koss Construction via the American Concrete Pavers Association (ACPA), has been developing an instrument capable of assessing tie bar and dowel bar placement accuracy for use in a paving environment. KDOT demonstrated a single-sensor prototype in 2004 that was capable of assessing tie bar depth at a rate of approximately two miles of construction joint per hour. In 2005, KDOT is moving forward with a revision of the tie bar placement specification appropriate for use with this type of sensing technology. KDOT is also pursuing a multi-sensor prototype in order to assess lateral placement accuracy and depth accuracy. In 2004, Koss Construction committed extra manpower to their paving operation that was dedicated to monitoring tie bar placement depth. The project sponsors intend to integrate the multisensor instrument directly into the paving equipment later this year to facilitate real-time quality control. BACKGROUND In 2001, KDOT began investigating the feasibility of developing an instrument capable of nondestructively assessing the depth and orientation of steel reinforcement, namely dowel bars and tie bars, in concrete pavements. After surveying possible techniques, magnetic tomography emerged as the most promising technology. Magnetic detection relies on magnetic permeability differences between the target (in this case, steel bars) and its surroundings (such as concrete). It is the same basic principle used in concrete cover meters. Tomography simply refers to the mapping of these magnetic properties to form a curve, contour, or image that represents the target. Although nondestructive electromagnetic techniques such as ground penetrating radar continue to be refined, magnetic tomography has the additional advantage of being unaffected by moisture, which allows it to be used on plastic concrete. An experimental x-y scanning table was constructed at the KDOT Materials and Research (M and R) in 2001. The scanning table coupled electronic signals from two optical encoders, one for each axis, with the audio feedback from a Kolectric MicroCovermeter and stored the data electronically in a PC. A sample of the data obtained from this device is shown in Figure 1. The picture depicts the placement of dowels in a dowel basket array (note that the vertical units are in error in the diagram). 0.03 Depth to steel - inches 0.025 0.02 0.015 0.01 30 20 Distance in inches 10 0 0 10 40 30 20 Distance in inches 50 Figure 1. Two-dimensional magnetic scan of a dowel array Young, Holle 2

Although cover meters are routinely used to investigate suspected misplaced steel and to locate reinforcement steel prior to drilling core samples, the use of a cover meter to systematically assess placement accuracy is far too manpower-intensive to be feasible. The data provided by the experimental 2D scanner indicated that the sensing technology within the cover meter was capable of yielding accurate depth and orientation when coupled with an electronic positioning device. The concept came to be known as a cover meter on wheels. In the fall of 2001, KSU Electrical and Computer Engineering proposed to KDOT the development of a cart-type device that incorporated this principle and could be used during construction behind a concrete paver. The proposal was accepted and work commenced in the summer of 2002. The resulting prototype is shown in Figure 2. Working with Kolectric, a custom cover meter was produced that directly outputs signal strength in real-time via an RS-232 serial connection. Distance was logged through use of an optical encoder wheel. The device demonstrated that depth and orientation of tie bars and dowel bars could be obtained with multiple passes over the joint. Rectangular slots cut in the transparent tray that carried the detection coil provided known distance left and right of the joint, which allowed the generation of multiple traces and the development of a 3D perspective of the steel s orientation. Figure 2. Prototype instrument developed at KSU in 2003 The device demonstrated its potential in the laboratory, but practical concerns of field operation prohibited multiple passes and prevented rapid data collection. The basic operational principles were valid, but the design of the cart went through two more iterations at the M and R laboratory in 2003 and 2004 before a functional prototype was produced. The current prototype, shown in Figure 3, was successfully demonstrated in field tests during the 2004 construction season. Young, Holle 3

Figure 3. M and R prototype built and field tested in 2004 The current three-wheeled device works in a similar fashion to the KSU prototype, but alterations in the chassis allow for rapid data collection. The acrylic sled for the sensor coil maintains an offset of approximately 1/4 of an inch from the concrete. The sled is fastened by two nylon bolts toward the front of the prototype. This allows the sled to rise whenever debris or excessive crown interferes with available clearance. These and other innovations allowed the prototype to demonstrate rapid data collection in 2004 in varying construction environments, including rain, mud, and heavy dust. Over four miles worth of data were collected in less than two hours on the last project. Table 1 lists the projects in 2004 where the current prototype was used to collect data. Table 1. Data collection activities in 2004 Date Description April 2004 Data samples on I-35 and I-70 following the MIT-SCAN July 2004 Wichita, sections of I135 North of Wichita ~3,000 feet of centerline longitudinal joint during rain August 2004 Kansas City, sections of 635 ~1,200 feet of longitudinal joint, extremely dusty environment August 2004 Wichita, ~6,000 feet of I-135 to confirm correction of tie bar placement process August 2005 Wellington Airport, ~1,000 feet of shoulder longitudinal joint to confirm suspected tie bar problem October 2004 I-35 near BETO junction, ~4 miles of data along center and shoulder longitudinal joint confirmed correct placement of tie bars Young, Holle 4

DATA ANALYSIS Presentation and analysis of data was performed using a customized program that displayed the onedimensional trace and estimated the depth to the tie bar. Examples of this are shown in Figures 4 and 5. Figure 4 depicts the location of tie bars along a shoulder joint on I-135 North of Wichita, Kansas. An exposed shoulder joint provides a convenient source for validating the instrument. The exposed steel tie bars allow for visual inspection and direct comparison with the results from the prototype instrument. Notice the irregularity at ~17 feet in Figure 4. This phenomenon is caused by the proximity of the steel dowel baskets at a transverse joint. Figure 4. Tie bar depth (in inches) along a 30-foot section Figure 5 depicts the depth of tie bars along the centerline joint on the same section of roadway. Note that in the first 30 feet, the tie bars are discernable, with one tie bar near the surface at 15 feet, probably at a transverse joint location. From 30 to 60 feet, most of the bars are near the bottom of the pavement. The data collected on this project confirmed a suspected tie bar inserter problem. Figure 5. Tie bar depth (in inches) along a 60-foot section The current prototype has been ruggedized for field work, but provides only depth to steel at the construction joint. Theoretically, multiple passes of the instrument at known lateral offsets from a construction joint could be combined to obtain orientation as well as depth, as was demonstrated in the laboratory at KSU. However, multiple passes are not practical in the field. Even if manpower were not an issue, debris on the road causes slight deviations in measured distance. These errors in turn cause inaccurate orientation calculations. An instrument that could take two or more depth measurements simultaneously would be more practical. This is the goal of the next prototype. Young, Holle 5

COMPLIMENTARY WORK In 2003, a German company began marketing a product in the United States called MIT-SCAN. MIT- SCAN is similar in concept to the current prototype, but it specifically targets the automated dowel bar inserter market. The MIT-SCAN instrument requires that a track be placed on the pavement prior to collecting data. MIT-SCAN contains five sensors and can assess the orientation of a dowel array in a single pass. However, several factors inhibit it from being used in the field on an ongoing basis. The dependence on a customized track limits its data collection speed. In April 2004, the M and R prototype was tested alongside the MIT-SCAN. The M and R prototype collected data at approximately twice the speed of the MIT-SCAN device, and this was prior to improvements in the prototype software that allowed for more rapid data collection. This combined with its high cost and other factors led KDOT to continue with its independent development. During the 2004 construction season, Koss Construction hired an additional worker on its concrete paving jobs to monitor tie steel placement. The sensing coil of a cover meter was placed on the burlap drag directly behind the paver. The worker was responsible for monitoring the cover meter, continuously checking for appropriate depth of tie steel. Normal paving consists of placement of two lanes of traffic and a shoulder in one pass. The meter was rotated between and centerline and shoulder joint throughout the day. Of the data collection activities in 2004, the I-35 project near BETO junction, constructed by Koss, was the only job in which the prototype confirmed correct placement of tie steel rather than confirming misplaced steel. FUTURE DEVELOPMENT Moving forward, KDOT has committed to revisit the specification that governs the accuracy of tie bar placement, assuming that an instrument is available, similar to the current prototype, suitable for field operation and capable of assessing both depth and lateral position with respect to the construction joint. The development of an appropriate specification is being led by Andrew Gisi from the KDOT Geotechnical Unit. Assessing lateral placement accuracy requires multi-sensor capability. The periodic send signal creates an exponentially decaying magnetic field which generates eddy currents in the tie bar. The eddy currents in turn induce magnetic fields about the tie bar. A receive coil detects the disturbance in the exponentially decaying magnetic field as a result of the presence of the tie steel. Synchronization of the send signals from multiple sensors is necessary if two or more cover meters operate within several meters of one another. If the meters are not synchronized, the timing circuitry of the receive coil will be foiled by the presence of an out-of-phase decaying magnetic field emanating from a different cover meter. The interference due to non-synchronized meters is analogous to the operation of multiple radars in close proximity. Send signals from one radar can interfere with receive signals in a second radar, causing erroneous readings. The prototype currently under development will be capable of simultaneously collecting three traces. Figure 6 depicts the control circuitry provided by Kolectric that allows for three sensors to operate synchronously. The cart to house the three-sensor version is being designed similarly to the cart shown in Figure 3. At the time of this writing, the multi-sensor prototype is under construction. Although synchronized operation of the three magnetic sensors has been demonstrated in the lab, the effects of proximity on detection range have yet to be assessed. Young, Holle 6

Figure 6. Control circuitry of three synchronized cover meters provided by Kolectric Figure 7 plots the sensor data from the three synchronized meters during a preliminary laboratory test. In the test, the sensor coils are positioned parallel to one another approximately six inches apart in the following order: Slave1, Master, Slave2. A steel dowel was passed over the array of sensor coils at a constant height (by hand). In the results graphed in Figure 7, Slave1 detects the bar first, then the Master, and then Slave2. On the return trip, the order is reversed, with Slave2 detecting the bar first, then the Master sensor in the middle, and finally Slave1 detects it again. The results in Figure 7 simply demonstrate that multiple sensors can operate in close proximity as long as the control circuitry is synchronized. It is unknown whether the detection range of each individual sensor is diminished due to the proximity of the other sensor coils. 6 x 104 Master 5 4 S lave1 S lave2 3 2 1 0-1 -2-3 -4 0 50 100 150 200 250 300 350 Figure 7. Results of preliminary laboratory test with synchronized meters Young, Holle 7

ACKNOWLEDGMENTS The authors wish to express their appreciation to Jim Devault and Ruth Miller, professors in the Department of Electrical and Computer Engineering at Kansas State University, for their collaboration and support in the project. Primary funding for this project was provided by the Kansas Department of Transportation through a grant to Kansas State University. Koss Construction Company and the American Concrete Pavers Association provided funding for the purchase of materials and equipment. All statements and opinions presented in this paper are the sole responsibility of the authors, and may not necessarily reflect those of the Kansas Department of Transportation. REFERENCE DeVault, J.E. and R.D. Miller. 2000. A Field Verification Instrument to Assess the Placement Accuracy of Dowel Bars and Tie Bars in PCCP. Final Report. K-TRAN Project # KSU-03-1. Kansas Department of Transportation. Young, Holle 8