Automatic Changeover Unit ECO8000 Datasheet

Similar documents
Automatic Changeover Unit ECO8020 Datasheet

Video Reference Timing with Tektronix Signal Generators

Tektronix Video Signal Generators

PatternPro Error Detector PED3200 and PED4000 Series Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Electrical Sampling Modules Datasheet 80E11 80E11X1 80E10B 80E09B 80E08B 80E07B 80E04 80E03 80E03-NV

Video Quality Monitors Sentry Edge II Datasheet

Electrical Sampling Modules

Arbitrary Waveform Generators AWGSYNC01 Synchronization Hub Datasheet

SignalCorrect Software and TCS70902 Calibration Source Option SC SignalCorrect software

46 GBaud Multi-Format Optical Transmitter

Tektronix Logic Analyzer Probes P6900 Series Datasheet for DDR Memory Applications

Video Quality Monitors

The use of Time Code within a Broadcast Facility

Black and Frozen Frame Detection

Data Pattern Generator

Quick Signal Integrity Troubleshooting with Integrated Logic Analyzers & Oscilloscopes

How-To Guide. LQV (Luminance Qualified Vector) Measurements with the WFM8200/8300

Limit and Mask Test Application Module

Analog Dual-Standard Waveform Monitor

Automated Limit Testing

Troubleshooting Analog to Digital Converter Offset using a Mixed Signal Oscilloscope APPLICATION NOTE

Data Pattern Generator DG2020A Data Sheet

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Video Quality Monitors Sentry Edge Datasheet

Comprehensive Production Tool Solution for 4K/UHD, WCG and HDR Content Creation PRISM Datasheet

5 Series MSO Serial Triggering and Analysis Applications 5-SRAUDIO, 5-SRAUTO, 5-SRCOMP, and 5-SREMBD Datasheet Serial triggering

C-PHY Essentials Transmitter Test Solution TekExpress C-PHY Essentials Tx

Logic Analyzer Triggering Techniques to Capture Elusive Problems

National Park Service Photo TSG-460 & CO 465. Universal SPG/TPG, Time Reference and Changeover Series.

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

Debugging a Mixed Signal Design with a Tektronix Mixed Signal Oscilloscope

Spearhead Display. How To Guide

The Benefits of External Waveform Monitors in Color Correction for Video. Application Note

Optical Sampling Modules 80C01 80C02 80C07B 80C08C 80C10 80C11 80C12

PAM4 Transmitter Analysis

Multistandard, Multiformat Waveform Rasterizers WVR5000 WVR4000 Data Sheet

Dual Scope Synchronization

Memory Interface Electrical Verification and Debug

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

Network Line Card Testing using the TDS3000B DPO Application Note. Line Card Testing Example: Throughput = Shippable Dollars

MPEG Solutions. Transition to H.264 Video. Equipment Under Test. Test Domain. Multiplexer. TX/RTX or TS Player TSCA

Low Cost, High Speed Spectrum Analyzers For RF Manufacturing APPLICATION NOTE

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

RFM220 ISDB-Tb Measurement Demodulator

Multi-standard, Multi-format Portable Waveform Monitors WFM5000 WFM4000

Multiformat Reference Sync Generator

Keysight Technologies N4974A PRBS Generator 44 Gb/s. Data Sheet

Agilent 87075C 75 Ohm Multiport Test Sets for use with Agilent E5061A ENA-L Network Analyzers

Timesaving Tips for Digital Debugging with a Logic Analyzer

Memory Interface Electrical Verification and Debug

Keysight Technologies ad Integrated RF Test Solution

Video Quality Monitors Sentry Datasheet

80C00 Optical Modules for DSA8300 Sampling Oscilloscope Datasheet

Multi-Standard, Multi-Format Portable Waveform Monitors WFM5000 WFM4000

Multiformat Reference Sync Generator SPG700 Datasheet

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

Optical Sampling Modules 80C02 80C07B 80C08C 80C10 80C10B 80C11 80C12

Truck router (3Gbps/HD/SD/ASI)

Multistandard, Multiformat Compact Waveform Monitors

Live events staging. Media centers

Master Sync / Master Clock Reference Generator

Memory Interface Electrical Verification and Debug DDRA Datasheet

Data Pattern Generator DG2020A Data Sheet

5600MSC, 5601MSC Master SPG/Master Clock Systems

Troubleshooting and Analyzing Digital Video Signals with CaptureVu

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

TLA5000B Series logic analyzers combine debug power with simplicity and affordability

Keysight Technologies Multi-Channel Audio Test using the Keysight U8903A Audio Analyzer

Memory Interface Electrical Verification and Debug DDRA DDR-LP4 Datasheet

Multiformat Video Generator TG700

VSG-401. Compact Video and Audio Signal Generator FEATURES

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

VariTime TM Digital Sync Generator, PT 5210

NVISION Compact Space and cost efficient utility routers

Accuracy Delta Time Accuracy Resolution Jitter Noise Floor

5600MSC, 5601MSC Master SPG/Master Clock Systems

SPG700 Multiformat Reference Sync Generator Release Notes

Data Pattern Generator

Timing and Synchronization in a Standard Definition Hybrid Video Facility

Using Triggered Video Capture to Improve Picture Quality

Agilent N4876A 28 Gb/s Multiplexer 2:1

Timing and Synchronization in a Multi-Standard, Multi-Format Video Facility

Agilent 87405C 100 MHz to 18 GHz Preamplifier

Multiformat Reference Sync Generator

Standard Definition Waveform Monitors WFM601A WFM601E WFM601M Data Sheet

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

TG700 TV Signal Generator Platform Release Notes

Master Sync / Master Clock Reference Generator SPG8000A datasheet

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

SPG700 Multiformat Reference Sync Generator Release Notes

How to Guide. Closed Caption Monitoring. WFM6120/7020/7120 & WVR6020/7020/7120 Version Software

CMN-91. Multiformat Signal Analyzer FEATURES

WVR500 Waveform/Vector Monitor

NOW all HD Panacea Routers offer 3 Gb/s (1080p) performance!

SyncroGenius. HD/HD PRO Video & Digital source AES/SPG Reference Generator

Timing and Synchronization in a Multi-Standard, Multi-Format Facility

Transcription:

Automatic Changeover Unit ECO8000 Datasheet The ECO8000 is a highly versatile automatic sync and signal changeover unit with configurations and capabilities required to address modern master sync application and other advanced sync timing application. This changeover unit offers exceptional reliability, stability and high availability and is designed with optional high bandwidth input changeover capabilities for HD/SD and/or 3G-SDI signal environments. Features & Benefits Switches analog black burst, HD tri-level sync, AES/DARS, word clock, LTC, as well as SD/HD/3G-SDI signals - all the timing and synchronization signals required in modern broadcast, production, and post production facilities Scalable product architecture to fit various application needs Electronic Fast Switch function for near glitch-less sync source switching, minimizing disruption in operations Automatic or Manual changeover mode Front panel LED fault indicators for each individual channel as well as the status of the power supplies Dual hot-swappable power supplies ensure continuous availability of reference signals Easy to manage with Web-based interface for configuration and SNMP for status and alert information Applications Sync generator and time reference generator system for broadcast, studio, mobile, and post-production facilities Master or slave (genlock) operation for distributed system architectures This changeover unit can be used with the following signal generators to form the complete sync generator system, which offers extra redundancy for the critical timing and synchronization system in the facilities. A pair of Tektronix Master Sync / Master Clock Reference Generators (SPG8000) for most broadcast facility timing applications A pair of Tektronix Test Signal Generators (TG8000) for more advanced post production facility timing applications Instrument configuration The ECO8000 provides up to nine user-configurable BNC and four LTC. Each channel consists of primary and backup inputs, and an output. The base configuration has three 50 MHz Electronic Fast Switch with options for six more 50 MHz Electronic Fast Switch or 3 GHz Relay Switch in groups of three each, plus four optional LTC. The 50 MHz Electronic Fast Switch support black burst, HD trilevel sync, AES/DARS, and word clock signals. The 3 GHz Relay Switch support SD/HD/3G-SDI signals as well as most analog reference signals. For applications that require more than nine BNC, two ECO8000 instruments can be configured to work as a single system which practically doubles the number of available (up to 18 BNC and eight LTC ). ECO8000 Automatic Changeover Unit front panel and back panel www.tektronix.com 1

Channel configuration Channel configuration can be set either via the front panel or the ECO8000 Web User Interface. Signal amplitude fault detection level follows the setting of the channel configuration. Detection on individual channel may be disabled, giving the option of disabling switching to the backup unit on failure of signals not critical to the facility operation. Changeover switching When operated in the switch-on-fault mode, the ECO8000 will automatically select the backup sync source should any of the primary inputs fail. However, in the unlikely event both sync sources are faulty, the ECO8000 will not alternate between the two sources. If necessary, this function may be overridden with the manual sync source selection. Manual source selection also facilitates periodic testing of the changeover function. 50 MHz Electronic Fast Switch The Electronic Fast Switch function, which comes standard with all 50 MHz Electronic Fast Switch, significantly improves the changeover switching speed and thus minimizes disturbance of the reference sync signals when switching between primary and backup inputs. The Electronic Fast Switch have latching relay backups that engage on loss of power to maintain the selected signal path. Optional 3 GHz Relay Switch The optional 3 GHz Relay Switch are optimized for SD/HD/3G- SDI signals, but are also usable for most reference signals. These utilize high bandwidth latching relays to preserve the selected signal path upon a loss of power. In addition, these are equipped with the Tektronix patent-pending "Relay Check" function 1. When this function is enabled, the instrument automatically checks the signal level on each 3 GHz Relay Switch channel before and after every changeover switch to determine the condition of the relay contacts of these. If it is determined that the relay contacts may have nonconductive coating (such as oxide) buildup, the instrument will cycle the relay rapidly for 20 times to wear through the layer of nonconductive coating in an attempt to restore the relay connections (relay self-cleaning attempt). Optional LTC The optional LTC channel connections are pin-compatible with the Tektronix SPG8000 and TG8000 2 generators, so these signals can be connected with standard 15 pin D-SUB cables. The same cable can be used to carry GPI connections, which allow the SPG8000 to trigger a changeover on certain error conditions such as loss of genlock. Front panel controls In association with the LCD display, front-panel controls are provided for source selection, operating mode, resetting the fault indicators, and for disabling the front-panel controls. LED fault indicators are also provided for each individual as well as the status of the power supplies. When the unit is connected to an Ethernet network, these functions are also available from the ECO8000 Web User Interface using a Web browser on a computer connected to the same network. Optional backup power supply The optional hot-swappable, redundant (backup) dual power supply system (Option DPW) virtually removes the risk of sync loss due to power supply unit failure, minimizing disruption in operations. Unique to the ECO8000 and ECO8020, the unit periodically tests the backup power supply to verify its performance. If the test fails, a fault will be indicated on the LED fault indicator as well as an error message for backup power supply replacement - providing extra assurance that the backup power supply will be ready when needed. Each power supply module has both AC and DC indicator LEDs. These LEDs continue to operate for 10 minutes after the loss of power. This allows quick troubleshooting in the event of supply or AC power failure. Alarm and status reporting Alarm and status information can be reported through SNMP, GPI, email notification, and/or the ECO8000 Web User Interface. 1 The Relay Check function on the 3 GHz Relay Switch operates only on that are connected (terminated). 2 The TG8000 generator must have a GPS7 module installed in order to support LTC generation. 2 www.tektronix.com

Specifications Inputs and outputs Typical return loss Base and Option REF 50 MHz Electronic Fast Switch Option HREF 3 GHz Relay Switch Insertion loss Base and Option REF 50 MHz Electronic Fast Switch Option HREF 3 GHz Relay Switch Maximum switched voltage Base and Option REF 50 MHz Electronic Fast Switch Option HREF 3 GHz Relay Switch Option LTC Maximum switched current (Option HREF only) Crosstalk Base and Option REF 50 MHz Electronic Fast Switch Option HREF 3 GHz Relay Switch Relay switch interruption time (Option HREF only) 35 db, 300 khz to 6 MHz 25 db, 6 MHz to 30 MHz 40 db, 300 khz to 6 MHz 30 db, 6 MHz to 30 MHz 15 db, 30 MHz to 1.5 GHz 10 db, 1.5 GHz to 3 GHz < ±0.2 db DC to 10 MHz Typical < -1 db DC to 50 MHz < -0.1 db DC to 10 MHz Typical < -3 db DC to 3 GHz Equivalent to approx 5 m of Belden 1694 cable -3 V to +5 V ±2.5 V peak, 1.5 V RMS ±5 V 100 ma Unselected input to output or channel to channel < -60 db, 300 khz to 6 MHz < -40 db, 6 MHz to 50 MHz < -48 db, DC to 1.5 GHz < -40 db, 1.5 GHz to 3 GHz Time that it takes for the relays to switch and settle Typically 0.5 ms to 2 ms Channel switch settling time (Base and Option REF only with identical signals on both inputs) Bi-level and Tri-level sync AES and 1 V word clock Time that it takes for the channel to switch and settle Typically 5 ns glitch, then 125 ns to 90% of final value Typically 5 ns glitch, then 250 ns to 90% of final value 5 V word clock Typically 25 ns glitch, then 500 ns to 90% of final value www.tektronix.com 3

Inputs and outputs Preset threshold signal types Base and Option REF 50 MHz Electronic Fast Switch Opt HREF 3 GHz Relay Switch Signal level range to detect fault with preset thresholds NTSC, PAL, Tri-level, AES, 1 V word clock, 5 V word clock, custom NTSC, PAL, Tri-level, AES, 1 V word clock, SD-SDI, HD-SDI, 3G-SDI, custom -2 db to -4 db from the nominal level for the selected signal type LTC LTC threshold presets LTC load range Crosstalk Switching interruption duration 0.5 to 5 V p-p in 0.5 V steps, differential or single ended 600 Ω to open circuit < -60 db for LTC signals Typically 1 ms Power source Mains ranges Voltage Frequency Power consumption 100 to 240 VAC 50/60 Hz 50 VA maximum Environmental Temperature Opeating Nonoperating 0 C to +50 C (+32 F to +122 F) -20 C to +60 C (-4 F to +140 F) Altitude Operating To 9842 ft. (3000 m) Regulatory EMC Safety Approved to: Complies with: Complies with EMC Directive 2004/108/EC UL61010-1, CAN/CSA-C22.2 No.61010-1. EN61010-1, IEC61010-1. 4 www.tektronix.com

Physical characteristics Dimensions Height Width Depth Weight Net 43.7 mm (1.72 in.) 483 mm (19.0 in.) 557 mm (21.9 in.) 4.5 kg (10.0 lb.) www.tektronix.com 5

Ordering information Models ECO8000 ECO (automatic changeover) base unit Includes: 3x 50 MHz Electronic Fast Switch (black burst, HD tri-level sync, AES/DARS, word clock) and a Quick Start User Manual (Tektronix part number 071-3221-xx) Options Instrument options DPW REF 3 HREF 3 LTC XLR RACK Add a second hot-swappable redundant (backup) power supply and second power cord Add 3x 50 MHz Electronic Fast Switch (black burst, HD tri-level sync, AES/DARS, word clock) Add 3x 3 GHz Relay Switch (3G-SDI, HD-SDI, SD-SDI, as well as black burst, HD tri-level sync, AES/DARS, word clock) Add 4x LTC Adapter cable (6 feet long) from 15-pin D-sub LTC OUT connector on the ECO8000 to 4 XLR male connectors (for LTC outputs) and BNC male connectors (for General Purpose Interface outputs) Rackmount slides and rails kit (1 RU height, standard full depth) Possible channel configurations Ordering configuration Slot 1 (Ch. 1-3) Slot 2 (Ch. 4-6) Slot 3 (Ch. 7-9) Base 50 MHz ELSW Empty Empty Opt. REF 50 MHz ELSW 50 MHz ELSW Empty Opt. REF, REF 50 MHz ELSW 50 MHz ELSW 50 MHz ELSW Opt. REF, HREF 50 MHz ELSW 50 MHz ELSW 3 GHz Relay Opt. HREF 50 MHz ELSW 3 GHz Relay Empty Opt. HREF, HREF 50 MHz ELSW 3 GHz Relay 3 GHz Relay Power plug options 4 Opt. A0 Opt. A1 Opt. A2 Opt. A3 Opt. A5 Opt. A6 Opt. A10 Opt. A11 Opt. A12 Opt. A99 North America power plug (115 V, 60 Hz) Universal Euro power plug (220 V, 50 Hz) United Kingdom power plug (240 V, 50 Hz) Australia power plug (240 V, 50 Hz) Switzerland power plug (220 V, 50 Hz) Japan power plug (100 V, 110/120 V, 60 Hz) China power plug (50 Hz) India power plug (50 Hz) (No locking cable) Brazil power plug (60 Hz) (No locking cable) No power cord 3 You can add any combination of Option REF and HREF channel modules, but the total number of additional modules is limited to two. When both REF and HREF modules are ordered, the REF modules are always installed so that they have lower channel numbers than the HREF modules. 4 All power cords include a locking mechanism except as otherwise noted. 6 www.tektronix.com

Service options Opt. C3 Opt. C5 Opt. D1 Calibration Service 3 Years Calibration Service 5 Years Calibration Data Report Opt. D3 Calibration Data Report 3 Years (with Opt. C3) Opt. D5 Calibration Data Report 5 Years (with Opt. C5) Opt. G3 Opt. G5 Opt. R3 Opt. R5 Complete Care 3 Years (includes loaner, scheduled calibration, and more) Complete Care 5 Years (includes loaner, scheduled calibration, and more) Repair Service 3 Years (including warranty) Repair Service 5 Years (including warranty) ECO800UP field upgrade options DPW LTC XLR RACK IF IFC Add a replacement or a second hot-swappable redundant (backup) power supply. A power cord option must be specified. (See Power Cord Options.) Add 4x LTC (software upgrade option) Adapter cable (6 feet long) from 15-pin D-sub LTC OUT connector on the ECO8000 to 4 XLR male connectors (for LTC outputs) and BNC male connectors (for General Purpose Interface outputs) Rackmount slides and rails kit for ECO8000 (1 RU height, standard full depth) Upgrade installation service Service installation and calibration Option DPW backup power supply www.tektronix.com 7

Option XLR adapter cable Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. 8 www.tektronix.com

www.tektronix.com 9

ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 6647564 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 April 2013 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com. Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 06 May 2014 20W-29403-1 www.tektronix.com