IQACO Changeover Switch

Similar documents
C Module Description

C Module Description

IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control

C Module Description

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

IQDDAC D to A Converter

IQVDA00/01 Analog Video Distribution Amplifier with RollCall Control

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

IQDMENCS Encoder. Module Description

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI

IQDLOG SDI Logo Inserter

C Module Description. IQMDMO MPEG-2 Decoder with MOLE Output

IQLOG00- HD/SD-SDI Logo Inserter IQLOG01- SD-SDI Logo Inserter

IQDMX21 4 Channel Analog Audio Demultiplexer

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Aspect Ratio Converter with Signaling

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

IQDEC01. Composite Decoder, Synchronizer, Audio Embedder with Noise Reduction - 12 bit. Does this module suit your application?

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

RPAN. Router Control Panel

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

IQUDC33. 3G/HD/SD-SDI Dual Up, Down and Cross Converter with AES I/O. Inputs & Outputs - IQH3A/1A/3B enclosures. Features

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

Model 4455 ASI Serial Digital Protection Switch Data Pack

Model 7600 HD/SD Embedder/ Disembedder Data Pack

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

FS3. Quick Start Guide. Overview. FS3 Control

User Instruction Manual IQMUX34. 3G/HD/SD-SDI Multiplexer for 8 Analog Channels.

C8000. switch over & ducking

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

DX-10 tm Digital Interface User s Guide

Model 5240 Digital to Analog Key Converter Data Pack

Model 6010 Four Channel 20-Bit Audio ADC Data Pack

IQMUX00/02/10/12 4/8 Channel Digital Audio Multiplexer with Synchronizer

Model 5405 Dual Analog Sync Generator Data Pack

EEG A1452 SCTE-104 Inserter Frame Card

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

User Instruction Manual IQDBT105. DVB-T/T2 Terrestrial Receiver & Monitor.

IQSYN20 HD/SD-SDI Frame Synchronizer

Dual channel HD/SD integrity checking probe with clean switch over function and wings or split screen creation capabilities

VISTEK V1633/A & V1633/D USER GUIDE.

3G/HD/SD dual channel audio embedder/de-embedder

FS4 Quick Start Guide

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

3G/HD/SD-SDI Universal Up, Down and Cross Converter

TECHNICAL MANUAL INTEGRITY 600 SERIES MDX644 HD/SD, AES/DOLBY E AUDIO DE-EMBEDDER/EMBEDDER

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

The Art of Engineering

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

IP LIVE PRODUCTION UNIT NXL-IP55

3G/HD/SD-SDI Frame Synchronizer with Advanced Audio Processing. 3G/HD/SD-SDI Multiplexer and Frame Synchronizer with AES/EBU and Analog Audio Inputs

Tebis application software

W-2x2 2x2, 1x3 or 1x4 Video Wall. Low Resolution. Monitor Output. CATx Extender Output) Low Resolution. Monitor Output (HDMI, DVI

Operating Instructions

DRAFT RELEASE FOR BETA EVALUATION ONLY

GNS600 SCTE104 VANC inserter, Ethernet data-bridge for 3G, HD and SD SDI Inputs and X31 Cue encoder/decoder

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card

AM-4 Audio Monitor. Videoquip Research Limited 595 Middlefield Road, Unit #4 Scarborough, Ontario, Canada. MIV 3S2

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

National Park Service Photo TSG-460 & CO 465. Universal SPG/TPG, Time Reference and Changeover Series.

OPERATING INSTRUCTIONS

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

VariTime TM Digital Sync Generator, PT 5210

Model 1476-C SuperQuad HR

Golden Gate Decoder, Synchronizer, Audio Embedder with Noise Reduction and Auxiliary SDI Input 12 bit

AC182A 8 Input x 8 Output S-Video Matrix Switch with Audio

TAHOMA opengear frame

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2

IQDBD00/01 HD/SD SDI 16 Channel AES/EBU Remultimplexer with Dolby Decoder

IQDANR SDI Advanced Noise Reducer

D-901 PC SOFTWARE Version 3

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

COPYRIGHT 2018 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM WITHOUT THE PERMISSION OF

CardModule. Reference Manual. Series C DA Channel SDI to CVBS Converter. Version 1.0

GFT Channel Digital Delay Generator

Cable Calibration Function for the 2400B/C and 2500A/B Series Microwave Signal Generators. Technical Brief

SG4424 HDTV Slave Sync Generator User Guide

V pro8 QUICK START GUIDE

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

USER MANUAL. Kramer Electronics, Ltd. Models:

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

American DJ. Show Designer. Software Revision 2.08

User Manual K.M.E. Dante Module

INSTRUCTION MANUAL VF MultiDyne. Harnessing The Power of Light

IQDMSES Multi-standard Digital Encoder

RADview-PC/TDM. Network Management System for TDM Applications Megaplex RAD Data Communications Publication No.

3Gb/s, HD, SD embedded domain Dolby E/D/D+ decoder and to Dolby E encoder with audio shuffler and optional audio description processor

TeamWork Kits Installation Guide

IP LIVE PRODUCTION UNIT NXL-IP55 USO RESTRITO. OPERATION MANUAL 1st Edition (Revised 2) [English]

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

HDSDI-CHO-2x1 HD-SDI-CHO-2x1-PB

Bel 2120B. Analogue/AES/SDI Shuffler. User s Guide Version /05/04

Transcription:

IQACO Changeover Switch C Module Description The IQACO is a passive changeover switch with composite video presence detection. Both inputs are monitored for sync presence, sync amplitude and line standard. The condition for switch over may be programmed to be sync loss or video standard change. The unit includes three GPI/O s that provide additional trigger inputs or tally outputs. In event of power loss input A is automatically selected. For additional security the relay switch is mounted in the rear panel assembly thus enabling the module to be removed from the chassis without breaking the connectivity of input A to output. RollCall remote and card edge controls are available. All fault or warning conditions can be reported and logged over RollCall. REAR PANEL VIEWS OUTPUT B A OUTPUT B A IQACO-2-B 3 2 1 2 PRIMARY GPI I/O OUTPUT B A IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.1

power power power information control home previous scroll adjust return modules lock help setup save recall OPEN IQACO Versions of the module cards available are: IQDCO-2 IQDCO SDI Changeover Double width module IQDCO-2A IQDCO SDI Changeover Double width module IQACO-2 IQACO Video Changeover Double width module IQACO-2A IQACO Video Changeover Double width module IQBCO-2 IQACO AES Audio Changeover Double width module IQBCO-2A-B IQACO AES Audio Changeover Double width module IQBCO-2A-D IQACO AES Audio Changeover Double width module Note that there are two styles of rear panels available. They are not interchangeable between the two styles of enclosures. However, the cards may be fitted into any style of enclosure. A Style Enclosure Rear panels with the suffix A may only be fitted into the A style enclosure shown below. O Style Enclosures Rear panels without the suffix A may only be fitted into the 0 style enclosures shown below. IQ display select (Enclosure order codes IQH3A-E-0, IQH3A-E-P, IQH3A-0-0, IQH3A-0-P) (Enclosure order codes IQH1S-RC-0, IQH1S-RC- AP, IQH1U-RC-0, IQH1U-RC-AP, Kudos Plus Products) (Enclosure order codes IQH3N-0, IQH3N-P) (Enclosure order codes IQH3U-RC-0, IQH3U-RC-P) IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.2

BLOCK DIAGRAM FittedonRear Panel A SW3 Input B 75 ohm SW3 Output A SW2 Input B 75 ohm SW2 Output A SW1 (Primary) Input B 75 ohm SW1 (Primary) Output RollCall Signal Detect Relays shown in power-off state 3 x GPI Processor Features Passive composite / pulse changeover switch Automatic switch over on programmable condition(s) Detection of sync presence, sync amplitude and line standard Continuity (A input) maintained with power loss or module removal Three programmable GPI/O s for control or tally Programmable switch over time delay RollCall remote and card edge control RollCall fault logging IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.3

TECHNICAL PROFILE Features Signal Inputs Primary Analog... 2 per channel (1 channel) Composite/Black Burst video via BNC Secondary Analog... 2 per channel (2 channels) For low data rate signals via BNC Signal Outputs (Passive) Primary Analog... 1 per channel (1 channel) via BNC Secondary Analog... 1 per channel (2 channels) via BNC GPI I/O... 3 x closing contact via BNC Card Edge Controls (also available via RollCall) Switch mode... Manual / Auto Manual switch... A / B Local... Selects default mode (cancels any RollCall programmed conditions) Indicators Power O.K. Input Loss A Input Loss B Input Standard A... 525/625 Input Standard B... 525/625 Low Sync A Low Sync B Functions available via RollCall only Switch condition... Any logical combination of warnings and GPI triggers GPI/O program... Tally any input state or warning or set as trigger Switch delay... 0 to 10s from trigger condition(s) Reporting & Logging... Input Loss; Input Line Standard; Low Sync Level Specifications Analog Input Level... Standard levels ±6 db Input Return Loss (Primary)better than 35 db to 6 MHz (Output terminated) Input Return Loss (Secondary) better than 35 db to 5 MHz (Output terminated) Output Return Loss (Primary) better than 35 db to 6 MHz (Inputs A and B terminated) Output Return Loss (Secondary) better than 35 db to 5 MHz (Inputs A and B terminated) GPI I/O Characteristics... Closing Contact Type Output Sink Current 100 ma Input Source Current 1 ma typical Input Threshold Voltage 1 V typical Power Consumption Module Power Consumption 1W max IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.4

Operational Overview The IQACO offers great flexibility in determining the conditions that can cause the switch to change from A to B and B to A. These conditions are set using a sequence of 5 RollCall programmable rules. Each rule is evaluated in turn with rule 1 taking the highest priority. If the rule is evaluated as true then the selected action will take place the actions available are to select input A or select input B. All of the rules are based on a definition of whether one of the inputs is either OK or Error. The default definition of OK is simply that the input is present, though it is possible to qualify this definition with other tests such as for a particular line standard, or low sync level Error is automatically defined as the converse of OK. Having chosen a definition of OK the sequence of rules can now be programmed. Each rule of the 5 available may be programmed to one of many conditions such as A_is_OK, B_in_Error, GPI_1_Closed, etc. Remember that each rule has only one action so it is necessary to set at least two rules to toggle the switch. It is also important to understand the difference between testing for OK and testing for Error. In dual redundant installations where signals on A and B inputs are of equal priority it would be normal to test for the Error condition so avoiding unnecessary switches when a previously failed input returns to good. However where the switch is used to enable a backup source it would be normal to test for the OK condition on the main input. Example: To set up a simple changeover function based on the following two rules - if A is present select input A and if A is not present select B requires Rule_1 to be set to Select_A if A_is_OK, and Rule_2 to be set to Select_B if A_in_error. In this example the unit will not check whether input B is present before switching over; if such a check is required then change Rule_2 to Select_B if B_is_OK. The rules also permit actions based on the state of the external GPI s. If, say a closed contact on GPI_1 is required to override any signal detection process set Rule_1 to Select_B if GPI_1_Closed. If signal detection as in the above example is required to have higher priority than GPI sensing then apply the GPI test under Rule_3. Under each rule it is possible to set a time delay. This is the length of time that the rule must be evaluated as true for before activating the action. If the rule is evaluated as false before the set time expires the action will be prevented and the time reset. Any of the three GPI ports may be set as tally outputs and the condition under which the output is active (closed contact) is fully programmable. For added flexibility it is possible to set a different definition of OK for the tally than that used for rule checking. The default or factory rule setting is for the backup switch example; thus Rule_1 is set to Select_A if A_is_OK and Rule_2 is set to Select_B if B_is_OK. Rules 3 to 5 are switched Off. The default setting for the GPI s is for GPI 1 to tally the switch state (closed contact = input B selected) with GPI 2 and GPI 3 set to tally the presence of signal on input A and input B respectively (closed contact = A/B_is_OK ). It is possible to return to the factory settings by using the Preset_Unit control. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.5

INPUTS AND OUTPUTS ANALOG INPUTS (A and B) These are the two analog inputs for each of the three channels via BNC connectors that terminate in 75 Ohms. 2 PRIMARY OUTPUT B A OUTPUT These are the analog outputs for each of the three channels via BNC connectors for 75 Ohms. Note: If the Primary output is not terminated correctly by 75 Ohms, the output may alternately select between input A and B until correctly terminated. To overcome this, in some systems it is possible to insert an in-line 75 Ohm termination at the receiving equipment input. This will have a detrimental effect on the stated receive distance i.e. will be reduced. An absolute figure is difficult to specify due to system configuration, cable type and connector type etc. GPI I/O These three GPI connectors may be configured independently as inputs or outputs. IQACO-2-B 3 2 1 GPI I/O IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.6

CARD EDGE CONTROLS INDICATORS +PWR and -PWR When illuminated these LED s indicate that the unit is powered. Loss A and Loss B When illuminated these LED s will indicate that there is no signal at the A or B inputs. A/B This LED will indicate which of the two inputs has been selected to become the output. When illuminated Input B has been selected, when OFF input A has been selected. 4 WAY DIP SWITCH SW1 Position 1 Not used Position 2 A/B Select This position allows either the A input or the B input to be selected and routed to the output if manual control is activated see position 3. When set to UP (OFF) channel B will be selected, when set to DOWN (ON) channel A will be selected. Position 3 Manual/Auto This position allows either manual selection of the input channel using position 2 of this switch or automatic switching in the event of AES Loss. DOWN (ON) selects Manual and UP (OFF) selects Automatic. Automatic mode activates the rule based changeover logic detailed in the operation overview section. To program the rules a RollCall control interface such as a RollCall front panel or the IQSPCR PC application is used. Position 4 Remote/Local This position allows either remote (RollCall) or local operation (using this DIP switch) of the module. Note that in Mainframes where RollCall is not available it should be set to the DOWN (ON) position. This ensures that when the unit is powered-up the factory default settings of parameters not available as card edge adjustments, are loaded. When set to the UP (OFF) position the card will power-up with the last settings stored in the non-volatile memory. In local mode the default automatic changeover logic selects input B if signal is lost on input A. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.7

CHANNEL A Low Sync This LED will be illuminated if the sync level of the input signal is below the sync threshold level setting. The default value for this setting is 250 mv. 625 This LED will be illuminated when the input signal standard is 625. 525 This LED will be illuminated when the input signal standard is 525. CHANNEL B Low Sync This LED will be illuminated if the sync level of the input signal is below the sync threshold level setting. The default value for this setting is 250 mv. 625 This LED will be illuminated when the input signal standard is 625. 525 This LED will be illuminated when the input signal standard is 525. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.8

IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.9

MENU DETAILS (see IQACO Menu System Opposite) MAIN MENU The main or top level menu allows various submenus to be selected by pressing the button adjacent to the required text line. IQACO MENU Force_A Rules... Setup... Force_B GPI_Setup... Note that where a menu item is followed by three dots (...) this indicates that a further sub-menu may be selected. Whenever a menu item is selected the parameters of that selection will be displayed in the Information window of the front panel. Where the selection is purely a mode selection and does not enable a sub-menu, the text will become reversed (white-onblack) indicating that the mode is active. If the mode is not available for selection the text will remain normal. Force A Force B When highlighted these items allow the manual selection of input A or input B. Note that they override all automatic control of the switch. Rules The automatic operation of the switch is governed by a sequence of Rules (for more information please see Operation Overview section) Rules Define_i/p_A_Ok... Define_i/p_B_Ok... Rule_1... Rule_2.. Rule_3... Rule_4... Rule_5... Define i/p A/B OK Define i/p A/B OK Input_Present Input_Sync_Level Input_Standard Input Present This is an essential element in determining that the input is OK! It is always active. The definition of OK may be defined using this item. Input_Sync_Level Input_Sync_Level Sync_>_Threshold Sync_Threshold This menu allows the definition of OK to be defined as when the sync level of the signal is greater than a set threshold level. Sync_>_Threshold Selecting this item (text highlighted) will enable the function. Note that the LED card edge indicators will still operate at the set threshold level even when this function is not selected. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.10

Sync_Threshold This item allows the threshold level of the sync amplitude to be set. The low sync LED card edge indicator will illuminate when the sync level falls below the Set Threshold level. Rule 1 to 5 Rule_1 to 5 Set_Rule_1to5... Time Delay Select A Select B Select A Select B Sync_Threshold Sync_Threshold 200mV Preset The range of control is from 150 mv to 250 mv in steps of 50 mv and preset is to 250 mv. Input_Standard This menu allows the standard of the input to be used to define the signal as OK. Input_Standard Std_is_525 Std_is_625 Std_is_625 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 625 line. Preset is to not selected. Std_is_525 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 525 line. Preset is to not selected. Note that only one of the standards may be selected. Each of the 5 rules available are programmed in an identical way. Each rule, if evaluated as true, may invoke one of two actions Select input A or Select input B. If no action is selected then the Rule is effectively disabled. Set Rule 1 to 5 Set_Rule_1 to 5 Off A_is_Ok B_is_Ok A_in_Error B_in_Error GPI_1_Open GPI_1_Closed GPI_2_Open GPI_2_Closed GPI_3_Open GPI_3_Closed The Rule is set here to any one of 10 possibilities including input checking and GPI condition. Off disables the Rule. Time Delay Time Delay Preset Time Delay 100ms Under each rule it is possible to set a time delay. This is the length of time that the rule must be evaluated as true for before activating the action. If the rule is evaluated as false before the set time expires the action will be prevented and the time reset. The time delay can be set between 0 and 10s. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.11

Setup Setup RollTracks... Logging... Preset_Unit Software Version Serial No Build No RollTracks This function allows information about the status changeover switch to be communicated to other RollTrack compatible modules connected to the network. This message can then be used to cause another unit to perform a specific action. Up to 6 RollTrack communication channels to compatible modules may be selected from the following menu: RTrk_1 RTrk_3 RTrk_5 RollTracks RTrk_2 RTrk_4 RTrk_6 RollTrack _1 to 6 When a particular RollTrack communication channel has been selected the following menu should be used to set up the Mode, Address and Data. RollTrack_1 to 6 RollTrack_1 to 6 Mode... RollTrack_1 to 6 Add RollTrack_1 to 6 Data RollTrack 1 to 6 Mode This sub-menu allows the unit to provide the following information about the status of the changeover switch to the connected RollTrack Unit. The destination unit will then perform a specific action in response to this information. RollTrack 1 to 6 Mode RollTrack 1 to 6 Add This item allows the address of the destination unit to be set. RollTrack_1 to 6 Add RollTrack_1 to 6 Add rt_add_1 to 6 Clear Preset OK When the item is selected, the first character will be in reversed flashing text; this character can then be changed by rotating the spinwheel. When the desired character is found the button to the left or right of the text line should be pressed and the next text character will be highlighted and available for changing. The buttons to the left and right of the text line may be used to select other characters. To save the new text, press the OK button. It should be noted that this is the only way to save the new text as any other button function will return to another menu without modifying the original text. The Preset button sets the text line to the default value. The Clear function sets the highlighted character to clear. RollTrack 1 to 6 Data To make the destination unit perform a particular function a RollCall command number must be entered using this function. RollTrack_1 to 6 Data RollTrack_1 to 6 Data rt_dat_1 to 6 Clear Preset OK For details of the RollCall command numbers for specific units please contact your local Snell & Wilcox agent. Off A Ok A in Error B Ok B in Error Using A Using B IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.12

Logging If a logging device is attached to the RollCall network, information about various parameters will be reported to the logging device assigned in the Remote Control Interface system. (See Section 1, The RCIF Menu System) Log Input A Log Input B Output Logging The logging sub-menu allows the following information to be made available for logging: Log Input A Log Input B Output Preset Unit Selecting this item sets all adjustment functions that include a preset facility, to their preset values. Note that this is a momentary action and the text will not become reversed. Software Version Selecting this item reveals a display showing the version of the software fitted in the module. Version 5.0.5 Version OK Select OK to return to the System Menu Serial No Selecting this item reveals a display showing the serial number of the module. Build No Selecting this item reveals a display showing the build number of the embedded software. This is part of the Snell & Wilcox revision control system. Build No xxxxxx Build No OK Select OK to return to the System Menu. GPI Setup Three independent GPI ports are provided. These may be individually configured as control inputs or tally outputs GPI Setup GPI_Ctrl_1... GPI_Ctrl_2... GPI_Ctrl_3... GPI Ctrl 1 to 3 GPI_Ctrl_1 to 3 Define_i/p_Ok... (Input)_To_Rules (Output)_A_Selected (Output)_B_Selected (Output)_A_Ok (Output)_B_Ok (Output)_A_Not_Ok (Output)_B_Not_Ok This menu should be used to select the operation of each GPI port. If a GPI input is used in any of the Rule definitions then it must be set to (Input)_To_Rules Serial No Serial No *************** OK Select OK to return to the System Menu. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.13

Define i/p Ok Define_i/p_Ok Use Rules Definition Define_i/p_Ok... The definition of OK may either follow that used in the Rule logic or be defined individually for each GPI output. The definition selections are the same as those shown above under Rules. UseRules_Definition When selected the definition of OK will follow that used in the Rule logic Define i/p Ok Define i/p_ok Input_Present Input_Sync_Level... Input_Standard... The definition of OK may be defined using this item. Input_Sync_Level Input_Sync_Level Sync_>_Threshold Sync_Threshold This menu allows the definition of OK to be defined as when the sync level of the signal is greater than a set threshold level. Sync_>_Threshold Selecting this item (text highlighted) will enable the function. Note that the LED card edge indicators will still operate at the set threshold level even when this function is not selected. Sync_Threshold This item allows the threshold level of the sync amplitude to be set. Sync_Threshold Sync_Threshold 200mV Preset The range of control is from 150 mv to 250 mv in steps of 50 mv and preset is to 250 mv. Input_Standard This menu allows the standard of the input to be used to define the signal as OK. Input_Standard Std_is_525 Std_is_625 Std_is_625 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 625 line. Preset is to not selected. Std_is_525 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 525 line. Preset is to not selected. Note that only one of the standards may be selected. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.14

ROLLCALL CONTROL TEMPLATES FOR THE IQACO Control Input Select Force A, Force B These items allow one of the inputs to be selected manually. This will override all other input selection methods. If neither of the inputs is selected here the input selection will be controlled by other means. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.15

Define Input OK This screen allows the condition of an input to be defined such that it is considered as valid or OK. Define Input A as OK, Define Input B as OK Standard is 625 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 625 line. Preset is to not selected. Standard is 525 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 525 line. Preset is to not selected. Note that only one of the standards may be selected. Sync Level > When this item is selected the input will only be considered OK if the sync level of the input signal is greater than the value set by the Sync Amplitude control. Note that for this and other screens the following applies: The and symbols at the ends of the scroll bar allow the value to be adjusted in discrete steps. The numerical value will be shown above the scroll bars and selecting (Preset) will return the setting to the preset value for the item. Sync Amplitude This scroll bar allows the sync level threshold for the above item to be set. Note that this control also sets the threshold level for the low sync card edge warning LED. The range of control is from 150 mv to 250 mv in 50 mv steps. Preset is to 250 mv. Note that if none of the above items are selected the input will be considered OK regardless of line standard or sync level; however the card edge low sync warning LED s will continue to operate. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.16

Rules 1-3, 4-5 The automatic operation of the switch is governed by a sequence of Rules (for more information please see Operation Overview section) Define Rule 1-3, 4-5 The action that is taken when a particular rule is evaluated as true may be set with this section. Each of the 5 rules available are programmed in an identical way. Each rule, if evaluated as true, may invoke one of two actions Select input A or Select input B. If no action is selected then the Rule is effectively disabled. Select Input A, Select Input B These items will set which input will be selected when the rule is evaluated as true. The Rule may be selected by highlighting the item and may be set to any one of 10 possibilities including input checking and GPI condition. Off disables the Rule. Time Delay Under each rule it is possible to set a time delay. This is the length of time that the rule must be evaluated as true for before activating the action. If the rule is evaluated as false before the set time expires the action will be prevented and the time reset. The time delay can be set between 0 and 10s. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.17

GPI, 2, 3 Setup Three independent GPI ports are provided. These may be individually configured as control inputs or tally outputs. GPI Port 1, 2, 3 Function This item should be used to select the operation of each GPI port. Input to Rules If a GPI input is used in any of the Rule definitions then this item must be enabled. GPI Port 1, 2, 3 Output This item allows the GPI port to be configured as an output and will provide an output corresponding to one of six selectable conditions. Define Input is OK for GPI 1, 2, 3 The definition of OK may either follow that used in the Rule logic or be defined individually for each GPI output. Use Rules Definition When selected the definition of Input is OK to produce an output will be that set by the Rules. Note that when this item is not selected the definition of Input is OK will be set by the following: Sync Level > When this item is selected the input will only be considered OK if the sync level of the input signal is greater than the value set by the Sync Amplitude control. Standard is 625 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 625 line. Preset is to not selected. Standard is 525 When this item is selected the input will only be considered OK if the detected line standard of the input signal is 525 line. Preset is to not selected. Note that only one of the standards may be selected. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.18

Setup Logging If a logging device is attached to the RollCall network, information about various parameters will be reported to the logging device assigned in the Remote Control Interface system. (See Section 1, The RCIF Menu System) the following information to be made available for logging: ❹ ❹ ❹ Input A Input B Output Preset Unit Selecting this item sets all adjustment functions that include a preset facility, to their preset values. Note that this is a momentary action. Software Version This item will show the version of the software fitted in the module. Serial Number This item will show the serial number of the module. Build Number This item shows the build number of the embedded software. This is part of the Snell & Wilcox revision control system. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.19

RollTrack 1-2, 3-4, 5-6 This function allows information about the status changeover switch to be communicated to other RollTrack compatible modules connected to the network. This message can then be used to cause another unit to perform a specific action. Up to six RollTrack communication channels to compatible modules may be selected. RollTrack (Channels) 1-2, 3-4, 5-6 This item allows the unit to provide information (selected from the list) about the status of the changeover switch to the connected RollTrack Unit. The destination unit will then perform a specific action in response to this information. Note that if Off is selected the RollTrack channel will be disabled. The destination for the delay information is set by the network code address as follows: RollTrack 1-2, 3-4, 5-6 Address This item allows the address of the selected destination unit to be set. To change the address, type the new destination in the text area and then select (return) (Preset) returns to the default destination The first set (0000) is the network segment code number The second set (10) is the number identifying the (enclosure/mainframe) unit For example: 0000:10:01 The third set (01) is the slot number in the unit RollTrack 1-2, 3-4, 5-6 Data To make the destination unit perform a particular function a RollCall command number must be entered in the Command ID Value text window using this function. For details of the RollCall command numbers for specific units please contact your local Snell & Wilcox agent. IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.20

Manual Revision Record Date Version No. Issue No. Change Comments 240701 1 1 First issue 160402 1 2 Now includes information for the 3A enclosure modules 010403 1 3 Power consumption added to techspec New manual issued New manual issued 220205 1 4 Unterminated output note added New manual issued 75 IQACO0PS 220205 www.snellwilcox.com Version 1 Issue 4 21c.21