Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

Similar documents
MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Ku-Band Redundant LNB Systems

X-Band Redundant LNB Systems

C-Band Redundant LNB Systems

Modular Block Converter Systems

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

Redundant LNB Systems

Redundant LNB Systems

Redundant LNB Systems

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

1:1 and 1:2 Redundant Low-Noise Ka-Band Block Converter Systems

Redundant LNB Systems

Instruction Manual Model BlockUpconverter

Multiple Band Outdoor Block Up- and Downconverters

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

SATCOM FIBER OPTIC PRODUCTS

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model # Block Upconverter

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SCR Series Synthesized Converters L, C, X, Ku, and DBS Bands

ModuMAX SSPA Systems C, X, and Ku-Bands

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

High Performance Outdoor Test Translators

Typical applications:

GEOSYNC. CAPABILITIES and PRODUCTS CATALOG. Outdoor Mounted. Rack Mounted. Converter Module. Block Converters, L-Band to Transponder Frequency

MONITOR POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

SYNTHESIZED COMMUNICATION CONVERTERS

High-Value 100 Series (Outdoor)

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Model /29S RF Splitter

Indoor Dual Converter

HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

OBSOLETE HMC7056. Block Upconverters / HPA's. Typical Applications. General Description. Features. Functional Block Diagram

MULTIBAND 1/3 RACK-MOUNTED

L-Band Block Upconverter MKT-74 Rev B JULY 2017 Page 1 of 7

10MHz Source/Inserter

1/3 RACK-MOUNTED BLOCK CONVERTERS

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

DUAL-, TRI- AND QUAD-BAND OUTDOOR BLOCK CONVERTERS

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

DA : Series of Narrowband or Wideband Distribution Amplifiers

Instruction Manual Model Downconverter

R-1580A Microwave Downconverter. Product Brochure

Satellite Up- and Downconverter Indoor / Outdoor

Inmarsat Downconverter Narrowband Downconverter

Model P/03P Upconverters

Synthesized Block Up- and Downconverter

Wideband LNB: 2.4 GHz

TELEDYNE Paradise Datacom A Teledyne Technologies Company

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

Noise Detector ND-1 Operating Manual

Instruction Manual Model UHF, L-Band, Up/Downconverter

HMC7053. Block Upconverters. Typical Applications. General Description. Features. Functional Block Diagram. Satellite communications.

-Preliminary- Ku-band PLL LNB - Internal Reference (L.O. Stability: ±1 ppm) - MODEL No. NJR2835U/36U/37U/39U series

11 GHz MDD FIBER OPTIC LINK FEATURES TYPICAL APPLICATIONS

Instruction Manual Model Block Downconverter

Synthesized Block Up- and Downconverter Indoor / Outdoor

DA E: Series of Narrowband or Wideband Distribution Amplifiers

16W Ku-band Matchbox BUC

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Instruction Manual Model Block Upconverter

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

L-Band Block Up- and Downconverter Indoor / Outdoor

CAM Series Channelized Agile Audio/Video Modulators

The Art of Engineering

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIDC-6005 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

SIDC-6003 MICROWAVE WIDEBAND DOWNCONVERTER / TUNER UP TO

Instruction Manual Model Up/Downconverter

FOM-9010, FOM-9011 and FOM-9012

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

INSTRUCTION MANUAL. MODEL Downconverter

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Converters Series Tri-Band Frequency Converters. Back to Multiband. Specifications Upconverters Downconverters Phase Noise Options Rear Panel

L-Band Block Upconverter

Instruction Manual Model Block Up/Downconverter

DVO700 P FIBRE OPTIC TRANSMITTER

ex 800 Series ematrix System

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

SIDC-5009 Series VHF/UHF WIDEBAND TUNER/CONVERTER. FREQUENCY RANGE: 20 to 3000 MHz

Satellite Up- and Downconverter

THE ART OF ENGINEERING

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Product Catalogue January 2018

Key Features and functions. General Description

ACION 8000 Series. A8KFR1 1RU Forward Receiver

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

Natural-sounding telephone audio... Hybrids

IF and L-Band Fiber Optic Links. Performance Highlights

ThinkRF D GHz RF Downconverter

MENU EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

i-repeater Control and monitor all your repeaters through the cloud Rackmount Wallmount

Ps Black (typ.) (typ.) Current Consumption

Transcription:

BRK-1000 Series Ku-Band Redundant LNB Systems Introduction Redundant LNB systems minimize system downtime due to LNB failure by providing a spare LNB and an automatic means of switching to the spare upon failure of a primary LNB. A 1:1 system provides one spare LNB for one primary LNB. A 1:2 system provides one spare LNB for either of two primary LNBs. The systems consist of an outdoor plate assembly which mounts at the antenna hub and an indoor control panel. System Block Diagrams 1:1 System RF IN (WR75) TEST IN -40 db IN Tx REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY LNB 1 LNB 2 RF Plate Assembly Features Norsat PLL LNBs High quality dual waveguide/coaxial switches Manual override Waveguide input flanges Tx reject filter(s), coupler(s), offline I/O, and input isolator options available Control Panel Features Standard 19" rack panel, 3½" high Dual, redundant power supplies Worldwide universal AC input capability Manual or automatic operation Monitors LNB bias currents to detect faults Automatically switches to standby LNB when fault occurs RS-232/-422/-485 and parallel I/O M&C interfaces Audible alarm CONTROLLER 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN (WR75) TEST IN -40 db IN CONTROLLER CONTROL/STATUS Tx REJECT CROSSGUIDE FILTER COUPLER Tx REJECT CROSSGUIDE FILTER COUPLER PLATE ASSEMBLY CONTROL/STATUS LNB 1 LNB 3 LNB 2 POL 1 POL 2 2120 Old Gatesburg Road, State College, PA 16803 USA Telephone 814-238-2700 FAX 814-238-6589 www.tripointglobal.com 11673 E 1

System Specifications * BRK-1000 Systems Parameter Notes Min Nom/Typ Max Units Input Frequency Range Band A 11.70 12.20 GHz Band B 10.95 11.70 GHz Band D 12.25 12.75 GHz Output Frequency Range Bands A, D 950 1450 MHz Band B 950 1700 MHz Noise Temperature, System At +23 C See Table 1 Versus temperature See Table 2 Gain Standard LNB 55 60 db Gain Flatness Per 27 MHz ±0.50 db Gain Stability Per day, constant temp ±0.25 db Versus temperature -0.06 db/ C VSWR Input, no isolator(s) 2.00 :1 Input, with isolator(s) 1.25 1.30 :1 Input with isolator(s) and Tx reject filter(s) 1.30 1.35 :1 Output (75 ohm) 1.80 2.00 :1 Power Output At 1 db compression +2 +5 dbm Third Order Intercept Output (OIP 3 ) +12 +15 dbm Local Oscillator Frequency Band A 10.75 GHz Band B 10.00 GHz Band D 11.30 GHz Frequency Stability -40 to +60 C ±10 khz Phase Noise 100 Hz Offset -65 dbc/hz 1 khz Offset -75 dbc/hz 10 khz Offset -80 dbc/hz 100 khz Offset -90 dbc/hz Maximum Input Power Without damage 0 dbm Desensitization Threshold No Tx filter(s) -20 dbm for 13.75-14.5 GHz in With Tx filter(s) +30 dbm Connectors RF Input WR75F Waveguide Flange RF Output Type F Female Offline In, Coupler In Type N Female Offline Out Type F Female Temperature Range Switch Plate Assy -40 +60 C When there is only one value on a line, this column is a nominal value. Otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. * System specifications depend on choice of LNB and various options. Specifications shown are for a typical system using commercially available LNBs. 2120 Old Gatesburg Road, State College, PA 16803 USA Telephone 814-238-2700 FAX 814-238-6589 www.tripointglobal.com 2 11673 E

Part Number/Ordering Information BRK- (Copy and FAX this page to VertexRSI.) Standard system includes: Plate Cable O&M Test LNBs Controller Assy Assy Manuals Data 1100 = 1:1 System 2 1 1 100 ft 1 x 1200 = 1:2 System 3 1 1 100 ft 1 x LNB Model number: Options Available: Cable length ft or m (Up to 500 ft [150 m] in 50 ft increments) Waveguide Input Isolator(s) Transmit Reject Filter(s) Input Crossguide Coupler(s) 40 db (std), db Offline LNB Input/Output Ports Remote Control Panel (RCP) Cable for Remote Panel ft or m (Up to 4000 ft [1200 m] in 50 ft increments) Additional O&M Manuals, Qty.: ±48 Vdc Power Option Table 1 Typical System Noise Temperature with Various Options (Add to T LNB )* 1:1 1:2 System Configuration Pol. 1 Pol. 2 Standby Standard Configuration (Add to T LNB ) 10 K 10 K 14 K 19 K With 40 db Crossguide Coupler(s) Add 2 K to Standard Configuration With Transmit Reject Filter(s) Add 13 K to Standard Configuration With Waveguide Isolator(s) Add 10 K to Standard Configuration Example: For a 1:1 system with 75 K LNBs, waveguide isolator and Tx reject filter, the system noise temperature at Example: +23 C is given by: T SYS = 75 K (LNB) + 10 K (Standard configuration) + 10 K (isolator) + 13 K (filter) = 108 K * VertexRSI has found that commercial Ku-band LNBs may measure up to 15K higher than stated noise temperature. Consequently, VertexRSI cannot guarantee system noise performance. Table 2 Noise Temperature vs. Ambient Temperature Noise temperature vs. ambient temperature can be found from the equation NT 2 T 2 = NT 1 T 1 n where NT 2 = Noise Temperature at T 2 NT 1 = Noise Temperature at T 1 T 2 = Temperature 2 in K T 1 = Temperature 1 in K n = 1.8 for LNB, 1.0 for passive losses For the case where T 1 = 296 K (+23 C), the ratio NT 2 /NT 1 is shown in the table at right for both LNBs (n = 1.8) and for passive losses (n = 1.0): Ambient Temperature n = 1.8 n = 1.0 T 2 ( C) NT 2 /NT 1 NT 2 /NT 1 0 0.86 0.92 +23 1.00 1.00 +40 1.11 1.06 +50 1.17 1.09 +60 1.24 1.13 Example: 1:1 system with Tx filter and 80 K LNB. T LNB = 80 K at +23 C, passive losses = 23 K at +23 C; thus T SYS = 103 K at +23 C. What is T SYS at +50 C? From the table, NT 2 /NT 1 at 50 C = 1.17 for the LNB and 1.09 for the passive losses. NT 2 = 1.17 x (80 K) + 1.09 x (23 K) NT 2 = 93.6 K + 25.1 K = 118.7 K at +50 C. 11673 E 3

Controller Front Panel (1:1 System): FAULTS INPUTS UNIT 1 PUTS CONTROLS 1:1 REDUNDANT SYSTEM CONTROLLER RSC-1100 CONTROLLER PS 1 PS 2 RCP FAULT RESET ON LINE CAL UNIT 2 CAL ON LINE LOCAL REMOTE REMOTE PANEL LOCK AUTO MANUAL SHIFT FUNCTION ABCDEFGH I J PANEL TEST INC SETTING 9 8 7 6 5 4 3 2 1 0 DEC Controller Front Panel (1:2 System): FAULTS INPUTS UNIT 1 PUTS CONTROLS 1:2 REDUNDANT SYSTEM CONTROLLER RSC-1200 CONTROLLER PS 1 PS 2 RCP FAULT RESET POL 1 CAL UNIT 3 POL 1 POL 2 CAL UNIT 2 POL 2 CAL LOCAL REMOTE REMOTE PANEL LOCK AUTO MANUAL SHIFT FUNCTION ABCDEFGH I J PANEL TEST INC SETTING 9 8 7 6 5 4 3 2 1 0 DEC Controller Rear Panel (All models): Specifications Controller LNB Status Monitor Method Control panel monitors LNB bias current. Alarm is generated if current goes outside of allowed tolerance window. Window Width ±5% to ±25% of nominal; software selectable in 5% steps Switchover Time 100 ms Serial I/O: Interface RS-232/RS-422/RS-485 2- or 4-wire Connector 9-Pin D, female Parallel I/O: Status outputs Form C dry contacts; 100 Vdc, 0.5 A, 3 W max (resistive load) Control inputs Contact closures to ground; withstand 15 V, sink 20 ma Connector 37-pin D, male Controller Dimensions 19" (483 mm) W x 3.47" (88.1 mm) H x 17.5" (445 mm) D; 25 lb (11.4 kg) Chassis Slides Standard Cable Length to Plate Assy 100 ft (30 m) to 250 ft (75 m) available AC Input 87-265 Vac, 47 63 Hz, 100 W. Dual AC inputs and dual redundant power supplies. Operating Temperature Range 0 to +50 C 2120 Old Gatesburg Road, State College, PA 16803 USA Telephone 814-238-2700 FAX 814-238-6589 www.tripointglobal.com 4 11673 E

Front Panel Controls and Indicators LNB Status Alarms PS1, PS2 Indicators Panel Test Pushbutton Unit Pushbuttons and Indicators Auto/Manual Switch and Indicators Remote/Local Switch and Indicators LED Indicators glow green when OK, red when an LNB fault is detected. Glow red to show fault with dual redundant power supplies. Lights all indicators & test audible alarm. Pushbuttons are used to manually switch the LNBs. Arrow indicators show which LNBs are switched on-line. Unit indicators light red to show faulted LNBs. In 1:1 systems, LNB1 is normally the primary LNB and LNB2 is on standby. In 1:2 systems, LNB1 and LNB2 are the primary LNBs for Polarization 1 and Polarization 2, respectively. LNB3 is the standby LNB and can be selected for either polarization. In Auto mode, an LNB failure initiates automatic switchover to the standby LNB. In manual mode, the on-line LNB can be selected from the front panel. Selects either local control, or remote control from serial I/O, parallel I/O, or remote panel. Rear Panel I/O Interface LINE 1 - J1, LINE 2 - J2 TO PLATE ASSEMBLY - J3 Parallel I/O - J8 Serial I/O and Loop - J6 & J7 RCP Link - J5 External Alarm - J4 Dual power entry modules contain the AC line input connector, fuses, and power switch. System can be powered from separate AC lines if desired. Either or both power supplies are capable of operating the system. Cable to antenna plate assembly carries LNB power and switch drive signals. System normally supplied with 100 feet of control cable; other lengths are optional. Parallel I/O connection for customer control or monitoring. Capable of controlling all features of the system except remote/local switch. Form C relay contact outputs (1:1 systems): LNB1 status PS1 status Auto/Manual mode LNB2 status PS2 status Local/Remote mode Switch position Control inputs contact closure to ground (1:1 systems): LNB1 select LNB2 select Auto/Manual select Form C relay contact outputs (1:2 systems): LNB1 status PS1 status Auto/Manual mode LNB2 status PS2 status Pol. 1: LNB1 or LNB3 LNB3 status Local/Remote mode Pol. 2: LNB2 or LNB3 Control inputs contact closure to ground (1:2 systems): Pol. 1: LNB1 select Pol. 2: LNB2 select Auto/Manual select Pol. 1: LNB3 select Pol. 2: LNB3 select RS-232/RS-422/RS-485 connectors for user M&C System. Commands provide monitoring, controlling, and configuration. For optional Remote Control panel, which duplicates all front panel functions. External Alarm inputs. Substitute for or combine with internal LNB current monitor alarms. Allows an external signal to indicate LNB failure. Unused inputs can be used as status inputs to M&C system. 11673 E 5

1:1 Plate Assembly Outline Drawing, with Various Options Installed Outline 8960-3 2120 Old Gatesburg Road, State College, PA 16803 USA Telephone 814-238-2700 FAX 814-238-6589 www.tripointglobal.com 6 11673 E

1:2 Plate Assembly Outline Drawing, with Various Options Installed Outline 8959-3 11673 E 7

OTHER VertexRSI PRODUCTS Low Noise Amplifiers and LNA Systems Solid-State Power Amplifiers and SSPA Systems General Purpose Converters Satellite Communications Equipment Custom Subsystems 11673 Rev. E ECR 6740 9/20/05 GLK Specifications are subject to change at VertexRSI's discretion. 2120 Old Gatesburg Road, State College, PA 16803 USA Telephone 814-238-2700 FAX 814-238-6589 www.tripointglobal.com 8 11673 E