LWC Series LWC-80. Design. LWC Series Laser Wire Counters. Product name: Accessories: LWC-80

Similar documents
L-LAS Series L-LAS-LT-2500-XL. Design. L-LAS Series Laser Line Sensors. Product name: L-LAS-LT-2500-XL

L-LAS Series L-LAS-LT-50-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

Manual Software SI-LCC-Scope V2.0

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

Transmitter optics with 9x white light LED (optics cover made of glass)

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

SPECTRO Series SPECTRO-3-50-FCL-JR. Design. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-FCL-JR (incl. software SPECTRO3-Scope)

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

SPECTRO Series SPECTRO-3-50-COF-...-CL. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series SPECTRO-3-50-UV-JR. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: SPECTRO-3-50-UV-JR (incl. software SPECTRO3-Scope)

SPECTRO Series SPECTRO-3-30-UV-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

SPECTRO Series. SPECTRO-1-30-UV/VIS-9x1. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-30-UV/UV. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO-1-50-DIL. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Product name:

SPECTRO Series SPECTRO /0 -MSM-ANA-VIS. Design. SPECTRO-3 Series True Color Sensors. Accessories: (p. 8-9) Product name:

Data Sheet SPECTRO-3-SLU-BA-ANA + SI-SLU-16. Receiver optics incl. 3-color filter detector (True Color), scratch-resistant optics cover made of glass

SPECTRO Series SPECTRO-3-50-FCL. Aufbau. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 10)

RLS Series RLS-GD-20/20. Design. RLS Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

SPECTRO Series SPECTRO-3-5-DIF-ANA. Design. SPECTRO-3 Series True Color Sensors. Product name:

L-LAS Series L-LAS-LT-130-SL-... Design. L-LAS Series Laser Line Sensors. Product name:

SPECTRO Series SPECTRO-1-POF. Design. SPECTRO-1 Series Single-Channel Sensors (Contrast Measurement) Accessories: (p ) Product name:

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

High Resolution Multicolor Contrast Scanner. Dimensioned drawing

Electrical connection

W100L: Laser Sensor in Mini- Format

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

Operating Instructions

R3-M-A1.1-(1.5) X (Receiver fiber optics incl. add-on aoptics KL-M18-A1.1 and blast-air top part ABL-M18-3)

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

Electrical connection

LD OEM/LD PDS/LD PeCo

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Electrical connection

Amplifier for fiber optics. Dimensioned drawing

V 180 Series Photoelectric Switches

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Fibre Optic Modem ODW-622

LUT Luminescence scanners: Seeing what no-one else can

SPACESCAN SERIES SS 02

ADVANCED ultrasonic sensors with analog output. Dimensioned drawing

Fibre Optic Modem ODW-611

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Electrical connection

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

W 190 L: Application-based Laser Technology, the optimum solution for demanding applications

Amplifier for fiber optics. Dimensioned drawing

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Electrical connection

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

ODW-621. RS-232 Point-to-point applications

Generator protection relay

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

Photoelectric Sensors E3F2

Process transmitter RMA422

Safety Light Curtains

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Assembly. Front view. LEDs. Parametrization interface. Power Bus

SU17 Series Fiber Optic Sensors

W 9-2: A Versatile, Complete and Compact Series

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectrics Through-beam Type PA18C.T..., DC

Operating instructions Electronic preset counter Type series 717

Absolute Encoders Multiturn

Technical data. General specifications. Indicators/operating means

ENCODER. Incremental Angle Transducer. Series A36, A58. Key-Features:

Ultrasonic Sensor Diffuse Mode Sensor RU600U-EM30E-LIU2PN8X2T-H1151/3GD

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Capacitive sensor BCT5-S18-UP6X2T-H1151

Data Acquisition Networks. Installing and Configuring the DM01 Hardware

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Process Transmitter RMA 422

Label Applicator HERMA 400

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

APPLICATIONS. Automatic warehouse. Trasportation lines

Safety Light Curtains GuardShield

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

BMOA Component Systems. Miniature Optical Sensors. c Features. Technical Description

LONWORKS Fibre Optic Converter

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

ENC - LKE51 - L I B

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Linear encoders without bearings incremental System for linear motion feedback

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

DVO700 P FIBRE OPTIC TRANSMITTER

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

IMPAC Infrared Thermometers

W 2: Sub-Miniature Photoelectric Switch Range: Super-Small and Powerful

Transcription:

LWC Series LWC-80 Laser Wire Counting - Insensitive to outside light (due to interference filter, modulated light) - Visible laser spot (red light 670 nm) - Parameterisable through integrated switch and RS232 - RS232 interface and Windows user interface - Automatic adjustment to product (laser power adjustment, dynamic dead time) - Sensitivity setting through step switch (16 steps) -- EXTERN-TRIGGER mode can be activated via PC - Counting of wires - Counting of copies in compensating stackers - Counting of copies during overhead conveying - Reliable counting also of high-glossy and high-contrast copies Design Product name: LWC-80 (incl. Windows software SI-LWC-Scope) Green LED for operating indication Cover of DIP and HEX switches 5-pin fem. connector Binder Series 702 (RS232 interface) Connecting cable: cab-las5/pc (2m) Knurled screw Accessories: TB-80 (attachment optics, cf. page 4) INI-18 (approach switch, cf. page 4) Mounting holes Sturdy aluminum housing, anodized in blue Yellow LED for switching state indication 8-pin fem. connector Binder Series 712 Connecting cable: cab-las8/sps (2m) Transmitter-/receiver optics Receiver optics incl. interference filter Mounting holes Laser transmitter optics incl. scratchresistant glass cover Receiver optics incl. interference filter (2006-02-24) LWC-80 / Page 1 of 12

Technical Data Model LWC-80 Laser Semi-conductor laser, 670 nm, AC operation, 1 mw max. opt. power, laser class 2 acc. to DIN EN 60825. The use of this laser sensor therefore requires no additional protective measures. Optical filter Interference filter and red light filter RG630 Digital output Voltage supply pnp bright-switching/npn dark-switching or pnp dark-switching/npn bright-switching (OUT0 and OUT1), adjustable under Windows on PC +12 VDC... +30 VDC S ensitivity setting under Windows on PC or by means of HEX coding switch (16 steps) Laser Current Dead Dead power correction consumption time time mode adjustable under Windows on PC typ. 150 ma adjustable under Windows on PC adjustable under Windows on PC Enclosure rating IP54 Operating Storage Housing Housing temperature range temperature range material dimensions Type of connector -20 C... +50 C -20 C... +85 C Aluminum, anodized in blue approx. 205 mm x 40 mm x 40 mm 8-pin female connector type Binder Series 712 5-pin female connector type Binder Series 702 E MC test acc. to IEC - 801... S can frequency typ. 15 khz (without averaging) Switching state indication Dynamic output (pulse lengthening) Max. switching current Visualization by means of a yellow LED adjustable under Windows on PC 100 ma, short-circuit protected I nterface RS232, parameterizable under Windows Connecting cables Modulation frequency Connection to PC: cab-las5/pc (2m) Connection to PLC: cab-las8/sps (2m) typ. 100 khz Max. counting rate typ. 500 000 edges/ h Min. height of object typ. 0.1 mm Output polarity Bright-/dark-switching, adjustable under Windows on PC Working range typ. 60 mm... 100 mm (2006-02-24) LWC-80 / Page 2 of 12

Dimensions optische Achse Alle Abmessungen in mm Working Distance All dimensions in mm (2006-02-24) LWC-80 / Page 3 of 12

Accessories Approach switch INI-18 Model INI-18 Switching Mounting Voltage Max. Max. load Ambient distance supply switching frequency temperature typ. 8.0 mm not flush mounted +10... +30 VDC 200 ma typ. 500 Hz -25 C... +70 C Enclosure rating IP67 Switching Housing Type state indication material of connector via LED in the M12-connector Brass, nickel-plated 4-pin M12-connector Tube TB-80 (for transmitter-/receiver optics) All dimensions in mm (2006-02-24) LWC-80 / Page 4 of 12

Connector Assignment Connection to PLC: 8-pole fem. connector Binder Series 712 Connection to PC: 5-pole fem. connector Binder Series 702 Pin No. Color Assignment Pin No. Assignment 1 white GND (0V) 2 brown +24VDC 3 green IN0 4 yellow IN1 5 grey OUT0 6 pink OUT1 7 blue n.c. 8 red n.c. 1 GND (0V) 2 TX0 3 RX0 4 n.c. 5 n.c. Connecting cable: cab-las5/pc Connecting cable: cab-las8/sps Connecting Cables Connecting cables: cab-las8/sps Length: 2 m Sheath: PUR cab-las5/pc Length: 2 m Sheath: PUR cab-las8/sps cab-las5/pc Laser Warning The laser wire counters of LWC Series comply with laser class 2 according to EN 60825. The use of these laser transmitters therefore requires no additional protective measures. The laser wire counters of LWC Series are supplied with a laser warning label. LASER RADIATION DO NOT STARE INTO THE BEAM CLASS II LASER PRODUCT (2006-02-24) LWC-80 / Page 5 of 12

Parameterization Windows software SI-LWC-Scope: The LWC-80 laser wire counter can be easily parameterised with the Windows user interface. For this purpose the LWC-80 system is connected to the PC with the serial interface cable cab-las5/pc. When parameterisation is finished, the PC can be disconnected again. Windows user interface PMOD: In this function field the operating mode of automatic power correction at the transmitter unit (laser) can be set. FIX: In this operating mode the POWER function field is enabled for setting purposes. The laser transmission power is kept constant at the value set in the POWER function field. DYN: In this operating mode the POWER function field is disabled for setting purposes. The laser transmission power is automatically and dynamically controlled in accordance with the amount of radiation that is diffusely reflected from the object. By using the intensities measured at the receiver, the automatic control circuit attempts to adjust the transmission power in such a way that the dynamic range is not exceeded. POWER[%]: In this function field the intensity of the laser diode can be set (0% = Laser OFF, 100% = full laser diode intensity). HOLD: This function field displays the output hold pulse length set with DIP switches DIP2, DIP3, and DIP4. Please note: The HOLD function field is disabled, i.e. it does not respond to mouse clicks or to the keyboard. However, the object is still used as a self-defined display object, i.e. the value set via the DIP-switch will be displayed when the GET button is pressed. PARA: This changeover switch determines whether the parameters BACKLIM, REGCNT, AVERAGE, DEAD TIME MODE, and DEAD TIME are displayed or hidden. 1 = Hide parameters 0 = Display parameters (2006-02-24) LWC-80 / Page 6 of 12

Parametrisierung THRESHOLD: Input field for the lower threshold. The sensor sensitivity increases with a higher THRESHOLD value. HYSTERESIS: Input field for the desired hysteresis. For detecting an edge, the NORM VALUE of the two RAW SIGNALS must drop below a certain THRESHOLD during measurement to initiate a counting event. Please note: The THRESHOLD and HYSTERESIS function fields are disabled, i.e. they do not respond to mouse clicks or to the keyboard. However, the object is still used as a self-defined display object, i.e. the values set via the HEX-switch will be displayed when the GET button is pressed. HYSTERESIS NORM When the sensor detects an edge (NORM VALUE drops below THRESHOLD), a search for the minimum NORM VALUE is performed until the end of the DEAD TIME (TRIGGER=CONT) or the ACTIVE TIME (TRIGGER=EXT) and during HOLD. This minimum value is stored in a 16-value JUMP-BUFFER that can be read out with the GETBUFF software button. THRESHOLD MIN After the value has dropped below a THRESHOLD, the NORM VALUE must again lie above the value set under HYSTERESIS, to allow renewed edge detection. This is an additional safety feature to suppress multiple counting around the THRESHOLD. OUT0 bei OUTMODE = direct HOLD OUT0 bei OUTMODE = inverse HOLD (2006-02-24) LWC-80 / Page 7 of 12

Parameterization TRIGGER = CONT: Measurement is performed continuously. Application example: Objects that are transported by means of mechanical or other kinds of grippers. The trigger signals (+24V) can be supplied to the sensor by means of inductive sensor or light barriers, etc. The advantage of this method of measuring is that the sensor is completely independent of the speed. TRIGGER = EXT: An ACTIVE WINDOW is set for the sensor by the two inputs IN0 and IN1. The window is opened with a positive signal edge at IN0, and is closed again with a positive signal edge at IN1. The sensor measures during its ACTIVE TIME, and if it detects an edge, an output counting pulse is provided immediately after the ACTIVE WINDOW is closed. Only one edge can be detected during the ACTIVE TIME. Output OUT1 serves for monitoring the active time. For renewed edge detection, the two inputs must detect a negative signal edge. TRIGGER = ADJ EXT: For future measurements with an active window (TRIGGER = EXT), this mode makes it easier for the user to adjust the two initiators for the active window; see picture below. IN0 For operating the sensor with an active window, two initiators must inform the sensor about the active time. As described above, the active window is opened with a positive signal edge at input IN0 and is closed again with a positive signal edge at input IN1. The TRIGGER = ADJ EXT mode was introduced to allow improved sensor adjustment. When this mode is selected, the sensor records the time from one positive signal edge at IN0 to the next positive signal edge at IN0 and valuates this time as 100%. This is shown in the graphic display, when the GO button is pressed and SOURCE = EXT is selected. When the GO button is pressed, the data are automatically updated after one second. The value of 100 on the x-axis corresponds with 100% (time from IN0 to IN0). IN1 OUT1 OBJEKT OUT0 = direct AKTIV FENSTER JA HOLD AKTIV FENSTER NEIN The red graph visualised the length of the active window in percent of the time between IN0 and IN0.The blue graph visualises the appearance of an edge in percent of the time between IN0 and IN0. It can be seen in the example shown here that the active window is equal to 59% of the time from IN0 to IN0, i.e. the sensor detected a positive signal edge at IN1 after 59% of IN0 to IN0, which closed the active window. The edge was detected at 30% of IN0 to IN0. These two values are also shown in the EDGE [%] and WIN [%] display fields. In practice, the active window should be open approx. 60% of IN0 to IN0. The edge should lie in the middle of the active window (30%). TRIGGER = COUNT With this evaluation mode it can be preset how many edges between two positive signal edges (e.g. from an angle encoder) must be counted at input IN0 for the sensor to provide an OK signal at OUT1. As usual the output signal upon detection of an edge is provided at OUT0. (2006-02-24) LWC-80 / Page 8 of 12

Parameterization BACKLIM: In this edit-box an intensity limit can be set. If the intensity that arrives at the receiver unit DAT0 (display window in the user interface) drops below this limit, no evaluation will be performed. REGCNT: This edit-box serves for setting after how many loop runs dynamic laser diode correction should be performed. Example: SCAN frequency 15 khz is equal to 66.6 μs REGCNT = 75 Calculation: 66.6 μs * 75 = 5 ms Result: Dynamic correction is performed every 5ms Explanation: Flatly rising magazines are detected, because dynamic correction is not performed with every loop run, and the jump is automatically compensated, so to speak. The EDIT-BOX REGCNT is enabled when PMOD = DYN. When PMOD = FIX the EDIT-BOX REGCNT is disabled as no laser transmitting power correction is done. AVERAGE: This edit-box serves for setting averaging through NORM. The minimum value for averaging is 1. The maximum value for averaging is 128. An average of 1 is sufficient for most applications. Please note: If AVERAGE = 1, the internal scan frequency = 15 khz. If AVERAGE = 2, the internal scan frequency = 7.5 khz. If AVERAGE = 4, the internal scan frequency = 3.75 khz. etc. OUTMODE: This edit-box determines how the output impulse should be output at OUT0: Direct: When a counting event occurs, output OUT0 changes from LOW (0V) to HIGH (+24V), until HOLD is over. Inverse: When a counting event occurs, output OUT0 changes from HIGH (+24V) to LOW (0V), until HOLD is over. DEAD TIME MODE (DT MODE): This function field shows the DEAD TIME MODE that is used, and the set dead time. DT MODE = FIX: A fixed dead time is used. The dead time is set in milliseconds with DIP switches DIP5, DIP6, DIP7, DIP8. DT MODE = DYN: A dynamic dead time is used. The dead time is set in percent with DIP switches DIP5, DIP6, DIP7, DIP8. The time between two edges is valuated as 100%.The dead time is calculated in accordance with the percent value that is set under DEAD TIME [%]. The dead time can be measured through monitor output OUT1 (low-active). If TRIGGER = EXT is selected, the sensor operates with an ACTIVE TIME. In this case the input fields DEAD TIME MODE and DEAD TIME [...] are disabled. The active time can be measured through monitor output OUT1 (low-active). Please note: These function fields are disabled, i.e. they do not respond to mouse clicks or to the keyboard. However, the object is still used as a self-defined display object, i.e. the value set via the DIP-switch will be displayed when the GET button is pressed. (2006-02-24) LWC-80 / Page 9 of 12

Parameterization TYPE: The data that are to be displayed in the graphic window (RAW, NORM) can be selected in this function field. RAW: The raw data DAT0 and DAT1 are visualised in the graphic window. In addition these values are displayed in the two numerical value output fields DAT0 and DAT1. NORM: The NORM calculated from DAT0 and DAT1 is displayed in the graphic window. In addition this value is displayed in the numerical value output field NORM. GETBUFF: When the GETBUFF button is clicked, the last minimum values of the NORM SIGNAL after edge detection are displayed. In addition, the THRESHOLD which the values of the NORM SIGNAL must remain under is visualized in the graphical display window. Upon detection of an edge the sensor starts to search the minimum value of the NORM SIGNAL during the DEAD TIME and HOLD. This value is then stored in a 16-value ring buffer. Based on these VALUES, the optimum THRESHOLD for the current product run can then be set. This group of function keys serves for parameter exchange between the PC and the control unit through the serial RS232 interface. SEND: When the SEND button is clicked, all the currently set parameters are transferred between the PC and the control unit or to an output file. The target of the respective parameter transfer is determined by the selected button (RAM, EE, or FILE). GET: The current setting values can be called up from the control unit by clicking on the GET button. The source of data exchange is determined by the selected button (RAM, EE, or FILE). RAM: The current parameters are written to the RAM memory of the control unit, or they are read from the RAM, i.e. these parameters are lost again when the voltage is switched off at the control unit. EE: The current parameters are written to the non-volatile memory of the EEPROM in the control unit, or they are read from the EEPROM, i.e. the parameters in the internal EEPROM are stored when the voltage is switched off. FILE: A click on this selection button opens an info field with the file name of the current parameter file. (2006-02-24) LWC-80 / Page 10 of 12

Setting 0 DEF 123 456789 C AB 1 2 3 4 5 6 7 8 ON Adjustment of DIP switch (effective only when TRIGGER = COUNT is activated!) The setpoint edge number is set with the DIP switches (DIP1... DIP8) that are integrated in the sensor. Setting is done in binary form from 0... 255. In addition the setting of the setpoint edge number can be checked with the DIP display window (in this example: 15) after pressing of the GET button. Adjustment of HEX coding switch The THRESHOLD value is preset with the hexadecimal switch (HEX) using the following encoding: Switch position: Threshold in digits: Hysteresis in digits: 0 8 100 1 16 100 2 24 100 3 32 100 4 40 100 5 48 100 6 56 100 7 64 100 8 72 100 9 80 (*) 100 A 88 100 B 96 106 C 104 114 D 112 122 E 120 130 F 128 138 (2006-02-24) LWC-80 / Page 11 of 12

Application Examples Detection of wires in the production of power cables In the production of power cables, individual wires might tear during the winding process, which would impair the quality of the power cables. An LWC-80 laser sensor reliably detects the individual wires during rotation. Due to the special, intensity- independent evaluation according to teh shadowing principle, the wires can be safely detected irrespective of color, surface, and speed of rotation. Automatic dead-time determination prevents multiple pulses per wire. (2006-02-24) LWC-80 / Page 12 of 12