Agilent Technologies 54522A

Similar documents
SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Digital Storage Oscilloscopes 2550 Series

ScopeMeter 190 Series Specifications

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

SDS1000C Specifications

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Portable Performance for Debug and Validation

Expect to Make Waves.

Agilent 5345A Universal Counter, 500 MHz

DataSheet. SDS1000DL Series Digital Oscilloscope

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

~.Yr / 12. Offset range: ±2 V (2 mv/div to 200 mv/div), ±SO V (> 200 mv/div to 5 V/div) "digital storage oscilloscope" 13.

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

50 MHz Digital Storage Oscilloscope

ADS1000C, CAL / CML Series

DataSheet SDS1000CML Series Digital Oscilloscope

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

DataSheet SDS1000CFL Series Digital Oscilloscope

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

2016 RIGOL TECHNOLOGIES, INC.

Agilent Series Oscilloscopes

LeCroy Digital Oscilloscopes

Agilent 54610B, 54615B and 54616B 500 MHz Oscilloscopes

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Digitizing Oscilloscopes

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

Oscilloscope Guide Tektronix TDS3034B & TDS3052B


What is oscilloscope? What an oscilloscope looks like. Oscilloscopes, accessories, applications Ján Šaliga

PicoScope 6407 Digitizer

Hewlett Packard 3577A 5Hz MHz Network Analyzer Specifications SOURCE

Data Pattern Generator

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Digitizing Oscilloscopes (2009)

8500A. Advanced Test Equipment Rentals ATEC (2832) channel capability. For tests on pulse mod- SERIES PEAK POWER METERS

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

Advanced Test Equipment Rentals ATEC (2832)

PicoScope 6407 Digitizer

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

Model 7330 Signal Source Analyzer Dedicated Phase Noise Test System V1.02

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

Meeting your needs R&S RTO2000 Digital Oscilloscope

DIGITAL OSCILLOSCOPES

SDS1000CNL+ Series Digital Oscilloscope. DataSheet

Technical Data. The HP 1660-Series Benchtop Logic Analyzers. Product Specifications and Characteristics. Finding the cause of difficult problems fast.

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

Errata. Title & Document Type: Manual Part Number: Revision Date: HP References in this Manual

SX-METRO A software package to meet all your needs

SDS1000DL+/CML+ Series Digital Oscilloscope. DataSheet

7000 Series Signal Source Analyzer & Dedicated Phase Noise Test System

ScopeMeter 190C/190B Series and ScopeMeter 120 Series

Data Pattern Generator DG2020A Data Sheet

OSCILLOSCOPE AND DIGITAL MULTIMETER

16 bit. A digital oscilloscope for the analog world HIGH-RESOLUTION USB OSCILLOSCOPE

Technical Reference. TDS 684A, TDS 744A, & TDS 784A Digitizing Oscilloscope Performance Verification and Specifications

Digital Phosphor Oscilloscopes

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

R3267/3273 Spectrum Analyzers

Datasheet SHF A

Advanced Test Equipment Rentals ATEC (2832)

Two Channel PC Oscilloscopes with Arbitrary Waveform Generator OMSP-2000 Series

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

HAMEG. Oscilloscopes. Innovation right from the start. Oscilloscopes

Generation of Novel Waveforms Using PSPL Pulse Generators

!Ill ~ 168. Model490 Dual Input, Dual Trace Automatic Peak Power Meter

User s Manual. TDO1000/TDO2000 Series Oscilloscopes

The Measurement Tools and What They Do

E4416A EPM-P Series Single Channel Power Meter

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Service Manual. TDS 520B, 540B, 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A Digitizing Oscilloscope

Digital Oscilloscope. Characterisation, Measurement & Analysis

In the development of electronic instruments or the analysis

Oscilloscopes for field applications

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

WAVERUNNER 104XI AND 204XI

TDS 520B, TDS 540B, TDS 620B, TDS 644B, TDS 680B, TDS 684B, TDS 724A, TDS 744A, & TDS 784A

SELECTION GUIDE Series of RF and Universal Frequency Counter/Timers

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

UDS-2022 * UDS-2021 Series PC-Sampling Oscilloscopes/ TDR/TDT

20 GHz bandwidth 17.5 ps rise time

BME 3512 Biomedical Laboratory Equipment List

PicoScope 9200A PC Sampling Oscilloscopes for Windows PCs

Oscilloscopes. the new hmo 3000 SerieS 300 Mhz 400 Mhz 500 Mhz

Frequency. Range. HP 83751A/B: 2 GHz to 20 GHz HP 83752A/B: 10 MHz to 20 GHz. Standard 10 MHz timebase: f10 ppm

R&S RT-Zxx High-Bandwidth Probes Specifications

Great Value in Test & Measurement. Mixed Signal Oscilloscopes HMO 3000 SerieS 300 MHz 400 MHz 500 MHz

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Digital Phosphor Oscilloscopes TDS3000C Series Datasheet

imso-104 Manual Revised July 19, 2012

University of Utah Electrical & Computer Engineering Department ECE1050/1060 Oscilloscope

INSTRUCTION GUIDE. for the. Keysight (formally Agilent; Hewlett-Packard) Model #33509B. and. Tektronix. Fall 2017

Digital Lock-In Amplifiers SR850 DSP lock-in amplifier with graphical display

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

100MHz 2[4] Channel Digital Oscilloscope HMO1022 [HMO1024]

Choosing an Oscilloscope

Transcription:

Agilent Technologies 54522A Data Sheet Product Specifications General Specifications Maximum Sample Rate 54522A 2 GSa/s Number of Channels (all are simultaneous acquisition) 54522A: 2 Record Length 32,768 pts (real time) maximum 501 pts (repetitive) Resolution 8 bits, 10 bits via HP-IB with averaging Vertical Specifications Repetitive Bandwidth 500 MHz (equivalent time) (rise time <= 700 ps) Real Time Bandwidth HP 54522A 500 MHz Sensitivity 1 mv/div to 5 V/div dc Gain Accuracy ± 1.25% of full scale Input Impedance R: 1 Mohm ± 1% or 50 ohm ± l% C: 7 pf nominal Input Coupling ac, dc Maximum Input

1 Mohm ± 250 V (dc + ac) [ac< l0 khz] 50 ohms: 5 V rms Offset Range Vertical Sensitivity Available Offset 1 mv to 50 mv/div ±2 V >50 mv to 250 mv/div ±l0 V >250 mv to 1.25 V/div ±50 V >1.25 V/div to 5 V/div ±250 V Offset Accuracy ±(l.25% of channel offset + 2% of full scale) Voltage Measurement Accuracy Dual Cursor ±[(1.25%)(full scale)+(0.032)(v/div)] Single Cursor ±[(1.25%)(full scale)+(offset accuracy)+ (0.016)(V/div)] Horizontal Specifications Time Base Range 500 ps/div to 5 s/div Resolution 10 ps Delta-t Accuracy Repetitive: (> 8 averages) [(0.005%)(delta-t)+ (100 ps + 0.1 % of full scale)] Real Time [(0.005%)(delta-t)+(0.2)(sample period)] Peak Detect [(0.005%)(delta-t)+(l sample period)] Time Tag Resolution 100 ps Accuracy ±[0.005%(reading)+l00ps] Delay Range (posttrigger) 10E07 x sample period Delay Range (pretrigger) 32K x (sample period) Trigger Specifications Sensitivity dc to 100 MHz 100 MHz to 500 MHz Internal 0.5 div 1.0 div External (54522A) 0.0225 x (signal range) 0.045 x (signal range) Auxiliary dc to 50 MHz: 250 mvp-p Pulse Width (minimum) 1 ns Level Range Internal ±1.5 X full scale from center screen External (54522A) ±25V Auxiliary ±5V Modes Edge, pattern, glitch, time qualified pattern, line, state, event-delayed, time-delayed, TV (NTSC, PAL, and user-definable formats) Trigger Coupling dc, ac, low frequency reject Display Characteristics Display Mode "A" models feature monochrome CRT (Cathode Ray Tube) displays. "C" models feature flat-panel color TFT (Thin Film Transistor) liquid-crystal displays.

Modes Averaging from 2 to 2048, envelope, infinite & variable persistence from 500 ms to 10 s, connect the dots, peak detect Graticules full grid, axes, frame, or no graticule Measurements Automatic 23 measurements on front panel or over HP-IB: Rise time V p-p V dc rms Fall time V min Preshoot Frequency V max Overshoot Period V avg Voltage at time - Width V base Time at min voltage + Width V amptd Time at max voltage Duty cycle V top Time at voltage Delta time V ac rms User-Definable Both upper and lower thresholds can be set from -25% to 125% for all automatic measurements Modes Continuous, statistics, limit test, or waveform compare Math/Analysis Functions Operators add, subtract, multiply, versus, integrate, differentiate, invert magnify, and FFT Additional Characteristics Peak Detect Captures and displays glitches or other high-speed events as narrow as 1 ns in real-time mode at sample rates of 250 MSa/s or less with sequential singleshot turned off. Sequential Captures successive single-shot events without Single Shot capturing the dead time in between, and stores up to 400 Kbytes of waveform data. Sequential Single-shot Throughput Record Waveforms Stored Max Number of Length Per Second Waveforms Stored 50 1333 4395 500 1111 739 8000 294 49 32,000 90 12 Waveform Store 4 nonvolatile, 2 pixel (volatile), and segmentable memory for storing measurement failure waveforms or sequential single-shot waveforms. Screen Update Rate (typical at 500 ns/div) record length (points) Real Time 500 8K 16K 32K updates/s. 150 110 84 58 Repetitive normal 8 avgs 128 avgs updates/s: 150 91 91

Optional Capabilities Optional Telecommunication-Mask Application Make telecom mask-template measurements to ANSI, CCITT, and ISDN standards using the HP 54520 or 54540 series oscilloscopes equipped with Option 001. Option 001 features 21 standard masks stored on a flexible disk. You can automatically trigger on positive isolated ones in live traffic for many standard telecom signals. The scope will automatically best-fit the test signal to many masks and give automatic pass-fail comparisons of the mask to its corresponding input signal. For more information on Option 001, Telecommunications Masks Applications ask your HP Sales representative for HP Product Overview 5963-1859E (international version) or 5963-1859 EUS (US version). Optional Active Probing The HP 1144A active probe features 800-MHz bandwidth, 2-pF input capacitance, and 1-Mohm input resistance. The HP 1145A two-channel active probe features 750-MHz bandwidth, 2-pF input capacitace, and 1 Mohm input resistance and is designed for easy connection to surface mount devices. I/O Characteristics HP-IB Fully programmable, complies with IEEE 488.2 RS-232 Bidirectional serial communication Centronics Talk-only parallel communication for HP PCL compatible printers Hardcopy Supported Printers Color "C" Models Monochrome "A" Models HP 540 Centronics Thinkjet HP-IB, RS232 HP 560C Centronics HP 540 Centronics HP 560C, Centronics B/W only Supported Plotters: HP Color Pro HP-IB HP 7440A HP-IB HP 7475A HP-IB HP 7475A HP-IB HP 7470A HP-IB HP 7470A HP-IB HP 7550A HP-IB HP 7550A HP-IB Disk Drive DOS-compatible, 3-1/2" disk drive to store and recall setups, waveforms, and screen images (TIFF, PCX, and EPS). The disk drive is also utilized to download the oscilloscope's operating-system software and can be used to upgrade the scope's software as future upgrades become available. A free software-upgrade notification service is offered to registered users. Front Panel Setups 9 (nonvolatile memories) FFT Characteristics Frequency Range: dc to 1GHz

Frequency Resolution Minimum (max samp rate)/(512 pts): 3.9 MHz Maximum (min samp rate)/(32,768 pts): 0.305 mhz Maximum (min samp rate)/(32,768 pts): 0.305 MHz Horizontal Magnify Specify the frequency that is displayed at center screen, and magnify the frequency-domain display about that point. Freq. Accuracy [1/2 (sample frequency) (1/32768)]+ (5 x 10E-5)(signal frequency) Amplitude Display Power in dbm Windowing Hanning, Flattop, Rectangular Environmental Characteristics Power Voltage 115/230 Vac, -25% to +15%, 48 to 440Hz, 350 VA maximum Weight Net: approximately 11.8 kg (261b) Shipping: Approximately 21.3 kg (47 lb) Dimensions Height: 218 mm (8.6 in) Width: 440 mm (17.3 in) Depth: 367 mm (14.5 in)