IQDMENCS Encoder. Module Description

Similar documents
IQDMSES Multi-standard Digital Encoder

IQDDAC D to A Converter

C Module Description

IQACO Changeover Switch

C Module Description

C Module Description

IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control

IQVDA00/01 Analog Video Distribution Amplifier with RollCall Control

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

IQDEC01. Composite Decoder, Synchronizer, Audio Embedder with Noise Reduction - 12 bit. Does this module suit your application?

C Module Description. IQMDMO MPEG-2 Decoder with MOLE Output

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

IQDLOG SDI Logo Inserter

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

Model 5240 Digital to Analog Key Converter Data Pack

Aspect Ratio Converter with Signaling

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI

IQDMX21 4 Channel Analog Audio Demultiplexer

R20AD 10-bit Universal Decoder R-series Card Module User Manual

Snell & Wilcox. Operator s Manual MDD500S. NTSC Decoder. December 1998

VISTEK V1668, V1668/SY & V1668/SY-VSL 12-BIT SDI TO PAL/NTSC ENCODER USER GUIDE.

Model 5405 Dual Analog Sync Generator Data Pack

IQDANR SDI Advanced Noise Reducer

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

IQUDC33. 3G/HD/SD-SDI Dual Up, Down and Cross Converter with AES I/O. Inputs & Outputs - IQH3A/1A/3B enclosures. Features

IQLOG00- HD/SD-SDI Logo Inserter IQLOG01- SD-SDI Logo Inserter

Instruction Manual. SMS 8601 NTSC/PAL to 270 Mb Decoder

SM02. High Definition Video Encoder and Pattern Generator. User Manual

IQMUX00/02/10/12 4/8 Channel Digital Audio Multiplexer with Synchronizer

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack

Specification of interfaces for 625 line digital PAL signals CONTENTS

3G/HD/SD-SDI Universal Up, Down and Cross Converter

VISTEK V1633/A & V1633/D USER GUIDE.

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

User Instruction Manual IQMUX34. 3G/HD/SD-SDI Multiplexer for 8 Analog Channels.

Kramer Electronics, Ltd. USER MANUAL. Model: SG Genlock Multistandard SPG / SDI / AUDIO Generator

SM01. Standard Definition Video Encoder. Pattern Generator. User Manual. and

SG4424 HDTV Slave Sync Generator User Guide

SDZHD Series. 16x16 HD/SD-SDI & AUDIO MATRIX

OPERATING GUIDE. HIGHlite 660 series. High Brightness Digital Video Projector 16:9 widescreen display. Rev A June A

MultiSystem Converter with built-in TBC/Genlock ID#488

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

FS3. Quick Start Guide. Overview. FS3 Control

Golden Gate Decoder, Synchronizer, Audio Embedder with Noise Reduction and Auxiliary SDI Input 12 bit

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

Manual Version V1.02

SPG8000A Master Sync / Clock Reference Generator Release Notes

R44E. 4-Channel Monitoring Encoder R-series Card Module User Manual. June 7, 2005 P/N

VariTime TM Digital Sync Generator, PT 5210

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

CONVI104 SWITCHER & ANALOG TO SDI CONVERTER CONVI 104-M 15/03/2006

Kramer Electronics, Ltd. USER MANUAL. Model: SG-6005xl. Genlock Multistandard SPG/Audio Generator

8500 Composite/SD Legalizer and Video Processing Frame Sync

ENC ENC-1103 SDI to Composite/CAV/RGB Encoder Guide to Installation and Operation M July 2008 DESCRIPTION FUNCTIONAL BLOCK DIAGRAM

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

SPG700 Multiformat Reference Sync Generator Release Notes

Interfaces and Sync Processors

Rec. ITU-R BT RECOMMENDATION ITU-R BT * WIDE-SCREEN SIGNALLING FOR BROADCASTING

RPAN. Router Control Panel

Analog to digital A/V (12 bit) bridge with SDI & embedded audio bypass/processing input COPYRIGHT 2010 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Tektronix Video Signal Generators

Model 7405 High Definition Test Signal Generator Data Pack

SingMai Electronics SM06. Advanced Composite Video Interface: HD-SDI to acvi converter module. User Manual. Revision 0.

Model 4455 ASI Serial Digital Protection Switch Data Pack

COMPOSITE VIDEO LUMINANCE METER MODEL VLM-40 LUMINANCE MODEL VLM-40 NTSC TECHNICAL INSTRUCTION MANUAL

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Model 7550 HD/SD Video Processing Frame Synchronizer Data Pack

R20CE 10-bit Encoder. R-series Card Module User Manual. August 25, 2003 P/N

E NSEMBLE. Carbon. Analog video interface for Silicon Graphics O2. User Manual. Software Version: v Date of Publication: 5/98 rev.

3G/HD/SD dual channel audio embedder/de-embedder

VSG-401. Compact Video and Audio Signal Generator FEATURES

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card

MODEL OTM-4870 FREQUENCY AGILE 870MHz F.C.C. COMPATIBLE TELEVISION MODULATOR

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

Bel 2120B. Analogue/AES/SDI Shuffler. User s Guide Version /05/04

Model 7500 HD Video Processing Frame Synchronizer Data Pack

C8000. switch over & ducking

DCD-24 Word Clock Distributor

SERVICE MANUAL TIME BASE CORRECTOR FA-145 (1 ST EDITION) FOR-A COMPANY LIMITED

QRF5000 MDU ENCODER. Data Sheet

Model 7600 HD/SD Embedder/ Disembedder Data Pack

Video to DVI 1080p Scaler Box - ID# 796

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

Teletext Inserter Firmware. User s Manual. Contents

National Park Service Photo TSG-460 & CO 465. Universal SPG/TPG, Time Reference and Changeover Series.

EBU INTERFACES FOR 625 LINE DIGITAL VIDEO SIGNALS AT THE 4:2:2 LEVEL OF CCIR RECOMMENDATION 601 CONTENTS

TECHNICAL MANUAL INTEGRITY 600 SERIES MDX644 HD/SD, AES/DOLBY E AUDIO DE-EMBEDDER/EMBEDDER

Model 7940 SD Aspect Ratio Converter Data Pack

AMX AMX-1842 HD/SD 4 AES Embedder Guide to Installation and Operation M January Description.

VM-100R. 1 RU HEIGHT PROGRAMMABLE 70 AND 140 MHz HIGH-PERFORMANCE VIDEO/AUDIO MODULATOR

V1602 / V1602CP. ANALOGUE VIDEO ROUTER - 16x2. Rev. 6

TSG 90 PATHFINDER NTSC Signal Generator

DEC/DES6800 CVBS/SDI Converter USER MANUAL

CM-392-Video to HDMI Scaler Box ID#481

2DB22. Dual 4 channel digital audio de-embedder

DIO24. 4 Channel Audio Sample Rate Converter Tracking delay ADD-ON card

Transcription:

IQDMENCS Encoder C Module Description The IQDMENCS is a full broadcast quality PAL/SECAM/NTSC encoder A 10-bit SDI input is encoded into PAL or SECAM for 625 line inputs or NTSC for 525 line inputs. A full frame synchronizer and color frame accurate genlock allows for simple installation. A 10-bit oversampled DAC gives excellent analog reconstruction. Without a reference a minimum delay mode is automatically selected. Encoding is in accordance to CCIR624. RollCall provides full remote control and monitoring. This product is available in single and double width form. REAR PANEL VIEWS COMPOSITE OUTPUT 3 1 2 IQDMENCS -2 6 5 4 2 REFERENCE SERIAL IN IQDMENCS-1 COMPOSITE 3 2 1 REFERENCE SERIAL IN IQDMENCS/SES-1-S COMPOSITE 2 1 SER OUT 1 REFERENCE SERIAL IN IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.1

power power power information control home previous scroll adjust return modules lock help setup save recall OPEN IQDMENCS Versions of the module cards available are: IQDMENCS-2 6 Composite output genlockable encoder Double width module IQDMENCS-1 3 Composite output genlockable encoder Single width module IQDMENCS-1-S 2 Composite 1 Serial output genlockable encoder Single width module IQDMENCS-1A 4 Composite output genlockable encoder Single width module IQDMENCS-1A-S 3 Composite 2 Serial output genlockable encoder Single width module IQDMENCS-2A-S 5 Composite 2 Serial output genlockable encoder Double width module Note that there are two styles of rear panels available. They are not interchangeable between the two styles of enclosures. However, the cards may be fitted into any style of enclosure. A Style Enclosure Rear panels with the suffix A may only be fitted into the A style enclosure shown below. O Style Enclosures Rear panels without the suffix A may only be fitted into the O style enclosures shown below. IQ display select (Enclosure order codes IQH3A-E-O, IQH3A-E-P, IQH3A-N-O, IQH3A-N-P) (Enclosure order codes IQH1S-RC-O, IQH1S-RC- AP, IQH1U-RC-O, IQH1U-RC-AP, Kudos Plus Products) (Enclosure order codes IQH3N-O, IQH3N-P) (Enclosure order codes IQH3U-RC-O, IQH3U-RC-P) IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.2

BLOCK DIAGRAM Reference Video SPG Serial 656 Input E Q Frame Synchronizer Encoder Up to 5 Composite Outputs SECAM Up to 2 Serial 656 Outputs Switches Processor RollCall Features PAL/NTSC/SECAM encoder Full genlock and minimum delay operation Full Frame synchronizer 10-bit oversampled DAC with CCIR quality reconstruction Up to 6 Composite outputs Up to 2 Serial 4:2:2 outputs Internal color bar generator and VITS Generation Pass or blank vertical interval data Selectable SECAM Bottles SECAM genlock to PAL switch or SECAM SECAM dynamic notch Tolerant of SMPTE RP168 serial switching EDH checking on SDI input RollTrack to link tracking audio delays RollCall compatible IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.3

TECHNICAL PROFILE Features Signal Inputs Serial Digital... 1 x Equalized SDI Standards... SMPTE 259M-C-1997 Reference Input... Composite or black burst Signal Outputs Analog... Up to 5 x Composite encoded Standards... PAL/NTSC/SECAM SDI... Up to 2 x Re-clocked SDI Standards... SMPTE 259M-C-1997 Card Edge Controls (also available via RollCall) Standard -... PAL/NTSC/SECAM Test pattern select... Black, Color bars or Mute VITS Insert... On/Off Vertical Data... Pass/Strip Genlock Mode... Internal (Min Delay) lock/ Zero ScH Lock Genlock H-Phase offset... ±1.9 lines Genlock SC Phase Offset.. 360 EDH Monitor... Reset Statistics SECAM Notch... On/Off SECAM Bottles... On/Off SECAM Carrier... On/Off SECAM Pre-Filter... On/Off Preset Unit... On Indicators Power Supplies OK No Input No Reference EDH... Present : error second : error hour ScH Error... Reference ScH error Flashes for synchronizer delay of > 1 ms Functions Available via RollCall Only RollTrack Compatible EDH Monitor... Show/Reset Statistics Logging... Input change/edhsch Error Specifications Signal Inputs Serial Input Return Loss... Better than 15 db to 270 MHz Reference Input Standard.. 525/625 (same standard as D1 input) Color Standard PAL/NTSC/SECAM Composite or Black Burst Reference Input Level Standard level ±3 db Signal Outputs Composite Encoding... 10-bit Y Frequency Response... 5.5 MHz ± 0.05 db U/I & V/Q Frequency Response Less than-3 db at 1.3 MHz Less than 20 db at 4.0 MHz Differential Gain... Better than 0.2% Differential Phase... Better than 0.2 ScH Phase... 0 ±2 Composite Output Return Loss Better than 35 db to 5.8 MHz Serial Output Return Loss.. Better than 15 db to 270 MHz Delay (minimum delay mode) Less than 3 µs Power Consumption Module Power Consumption 6.9 W max EMC Performance Information Environment... Commercial and light industrial E2 Peak Mains Inrush Current following a 5 second mains interruption No mains input Performance Information... No performance degradations or cable length limitations IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.4

INPUTS AND OUTPUTS SERIAL INPUT This connector is the serial digital video input to the encoder via a BNC connector terminated in 75 Ohms. IQDMENCS-1/2 SERIAL IN IQDMENCS-1A/-S IQDMENCS-2A-S REFERENCE INPUT These are the high impedance loop-through connections via BNC connectors for a black burst or composite video reference signal. 2 REFERENCE IQDMENCS-1/2 IQDMENCS-1A IQDMENCS-2A-S IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.5

COMPOSITE OUTPUTS These are the composite video outputs of the unit via BNC connectors. COMPOSITE OUTPUT 3 1 2 IQDMENCS -2 6 5 4 2 IQDMENCS-2 REFEREN IQDMENCS-2A-S IQDMENCS 1 COMPOSITE 3 2 1 IQDMENCS-1 IQDMENCS-1A SERIAL OUTPUTS These are the Serial video outputs of the unit via BNC connectors. IQDMENCS-1A SER OUT 1 IQDMENCS-2A-S IQDMENCS-1-S IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.6

CARD EDGE CONTROLS Adjustment of the settings of the IQDMENCS is available either via card edge controls and/or via a more comprehensive remote control system using RollCall Note that the availability of some of the card edge controls will depend on the card version; see feature table for variations. LED INDICATORS +5V and -5V When illuminated these LED s indicate that the +5 V and -5 V supplies are present. No Input The No Input LED will be continuously illuminated when the unit is not receiving an input signal. Note that in Genlock mode this LED will flash when the input signal is of a different standard to that of the reference input. Under these conditions the output signal standard will be the same as the reference signal and the input signal will be ignored. No Ref When the No Ref LED is illuminated the unit is not receiving a reference input signal. Note that the No Input and No Ref LEDs will flash alternately when the unit is configuring or reconfiguring in the event of a standard change. The message Please wait... will appear in the lower line of the Information Window during this operation. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.7

EDH Present This LED will be illuminated if EDH is present on the serial input. In the event of an EDH error being detected the EDH Present LED will become extinguished and the EDH Sec and EDH Hour LEDs will become appropriately illuminated. EDH Sec The EDH Sec LED will be extinguished if no errors have occurred during the previous second. EDH Hour The EDH Hour LED will be extinguished if no errors have occurred during the previous hour. ScH Error/Delay Warning This dual function LED warns of Genlock error conditions. It will be illuminated if ScH errors are detected in the reference signal. It will flash to warn when the delay through the synchronizer exceeds 1 ms. LINKS Remote LK1 Note that the unit will respond to both local and remote control, one system overriding the settings of the other. For cards using the RollCall remote control system, activating the switches will override the remote control settings. The RollCall control panel will then follow these settings. Note that in Main-frames where RollCall is not available the link LK1 (Remote) should be set to the OFF (unconnected) position. This ensures that when the unit is powered-up the factory default settings of parameters not available as card edge adjustments are loaded. With the link in the ON (connected) position card will power-up with the last settings sent by the remote control panel. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.8

SWITCHES Two push buttons, a Hex switch and a 8 way DIL switch allow various functions and modes to be set. The DIL switch selects a particular function and the Hex switch (mode select) selects a mode or parameter that may be adjusted. The push buttons PB1, PB2 allow the value of the selected function/parameter to be adjusted. Note that to select the preset value both buttons should be pressed together. These switches allow the module to be operated when an active front panel is not available. All functions available via an active front panel are duplicated by these switches. More detailed information about these functions will be found under MENU DETAILS starting on page 11b.13. FUNCTION AND MODE SELECTIONS DIL SWITCH FUNCTIONS Position 1 When set to ON (Down) the encoder will produce a test pattern signal as its output. Position 2 (SECAM Operation only) When set to OFF the output SECAM-V color ident signal (Bottles) will be switched ON. When set to ON the output SECAM-V color ident signal (Bottles) will be switched OFF. Note that in PAL/ NTSC operation this position will have no function. Position 3 (Genlock Mode PAL/NTSC Operation) When set to OFF (Up) Zero ScH lock will be enabled. When set to ON (Down) genlock will be disabled and the internal mode (Freerun) will be enabled. Position 3 (Genlock Mode SECAM Operation) When set to OFF (Up) the genlock mode will be enabled. When set to ON (Down) genlock will be disabled and the internal mode (Freerun) will be enabled. Position 4 (Vertical Data) When set to OFF (UP) the encoder will pass vertical interval data (unblanked) to the output. When set to ON (Down) all data in the vertical interval will be blanked. Positions 5, 6, and 8 have no function. Note that the output will H phase to a PAL black or black-burst reference; Db/Dr phase is such that if the reference has a PAL burst, a V-Switch (Phase = 135 ) of burst on Line 1, Field 1 will produce a Dr line in the encoded output. If a SECAM reference signal is used the output Db/Dr sequence will be locked to that of the reference signal. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.9

Position 7 This position allows the output standard for 625 line inputs to be set. Standard Position 7 SECAM ON PAL OFF Operating Standard The output standard is determined by the operating line standard - for 525 line the output will be NTSC; for 625 line the output will be PAL or SECAM. The operating line standard will be determined by the following detection method (in order of priority) 1. The reference input standard (signal input standard ignored) when in Genlock mode. 2. If there is no reference signal, by the input signal standard. 3. If there is no reference signal and no signal input the standard may be selected by using either the Mode Select switch or the Menu system of an active front panel. Note that to use this method of selection the module must be operating in the Internal Lock mode set by the DIL switch position 3 or via the Genlock menu. MODE SELECT SWITCH The Mode select switch may select a mode or a parameter that may be adjusted. The push buttons allow the value of the selected function/parameter to be adjusted. Note that to select the preset value both buttons should be pressed together. Function Switch Action of PB1 Action of PB2 S/C Phase 0 Rotates vectors anticlockwise Rotates vectors clockwise H Phase 1 Moves output ahead of reference Moves reference ahead of output Pattern Select 2 Toggles Black/Bars Toggles Black/Bars No Function 3 No Function 4 VITS Insert 5 Removes VITS Inserts VITS EDH Reset 6 Resets EDH statistics Resets EDH statistics No Function 7 No Function 8 Standard (1) 9 Selects 625 PAL/SECAM standard Selects 525 NTSC standard SECAM Notch A Turns OFF notch Turns ON notch SECAM Carrier B Turns ON carrier Turns OFF carrier SECAM pre-filter C Turns OFF pre-filter Turns ON pre-filter No Function D No Function E Preset Unit F Press together to select all preset values (1) Normally the standard selection is automatic. If there is no input signal and no reference signal available to determine the operating standard this switch and the DIL switch (position 7) should be used to set the output standard. Ensure that the Genlock Mode is set to Internal Lock. Note that the availability of some of the above functions will depend on the operating mode of the module. e.g. test patterns will be different for different line standards; availability of phasing controls will depend on the genlock mode etc. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.10

Operation from an Active Control Panel The card may be operated from an active control panel via the RollCall network. All operational parameters and selections are made using a system of menus displayed in two LCD windows. Operational details for the remote control panel can be found in the Modular System Operator's Manual. Information Window The Information window has four lines of text indicating current selections and various information messages. Note that in a RollCall system some units will overwrite the information window indication with their own messages. Under these conditions the control panel will only be able to write to the information window when the unit has been disconnected. 01:IQDMENCS Inp: OK Std:PAL Ref:OK EDH:OK DW ZSC PVD PAT The first line will contain the name of the module that is currently being controlled. The second, third and fourth lines provide specific information about the operating conditions of the module. Text Line Details for example opposite: Line 1 Line 2 This line contains the name of the module and Gateway code data. This line gives information about the state of the video input and the output standard. Input state may be OK, ERR (input error detected) or ***(no signal connected) Output standard may be PAL or NTSC. Line 4 ZSC This will display setup messages: Genlock Zero SC/H Lock enabled If the text is static (not flashing) this indicates that the unit has successfully genlocked to the reference source. If the text is flashing this indicates that the unit is attempting to genlock to the reference source. Line 3 This line gives information about the state of the reference input. Reference may be OK, ***(no signal connected) or SCE (a subcarrier error detected. e.g. a ScH error of >20 ) It will also show EDH statistics (NONE, Fail or OK) and whether the synchroniser delay has exceeded 1 ms (DW = Delay Warning) GEN VTS PVD PAT SECAM Genlock Insert VITS enabled Pass Vertical Data enabled Pattern ON enabled IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.11

Control Window The Control window displays all Selection Menus and sub-menus. The selection is made by pressing the button adjacent to the required item. Inputs Display AutoCycle Setup The menu structure is shown below. Standard PAL/NTSC SECAM/NTSC Patterns Pattern On MUTE BLACK 75% COLOUR BARS SECAM_Options 625 Notch_Filter AutoDetect Bottles Carrier_Off Chroma_Pre_Filter Unit_1 Unit_3 Unit_5 Unit_7 RollTrack Unit _x 0000:00:0040 Clear Preset Logging Inp/Std_Change Ref_Loss EDH_Errors Unit_2 Unit_4 Unit_6 Unit_8 OK IQDMENCS MENU Standard... Patterns... Setup... Serial No xxxxxxx Setup Insert_VITS Pass_Vertical_Data Pass_Line_23 SECAM_Options... RollTrack... Show_RT_Errors Preset_Unit Logging... Default Output... Software Version Serial_No Serial_No Genlock... EDH... Default Output MUTE BLACK 75% COLOUR BARS OK Software Version Software_Version 5.6.6 OK H_Phase 0 ns Preset Genlock Internal Zero_Sch_Lock SC_Phase H_Phase H_Phase Fine_H_Phase Fine_H_Phase 0 ns Preset SC_Phase SC_Phase 0.0 Deg Preset EDH 625 Show_Stats AutoDetect Reset_Stats IQDMENCS Menu System IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.12

MENU DETAILS (see IQDMENCS Menu System on previous page) MAIN MENU The main, or top level menu allows various submenus to be selected by pressing the button adjacent to the required text line. Note that where a menu item is followed by three dots (...) this indicates that a further sub-menu may be selected. Whenever a menu item is selected the parameters of that selection will be displayed in the Information window of the front panel. Where the selection is purely a mode selection and does not enable a sub-menu, the text will become reversed (white-onblack) indicating that the mode is active. If the mode is not available for selection the text will remain normal. IQDMENCS MENU Standard... Patterns... Setup... Genlock... EDH... Standard This menu selection allows the operating standard of the unit to be set. Standard PAL/NTSC SECAM/NTSC The operating line standard will be determined by the following detection method (in order of priority) 1. The reference input standard (input signal standard is ignored) when in Genlock mode 2. If there is no reference signal, by the input signal standard. 3. If there is no reference signal and no signal input the standard may be selected by using this menu. This allows the module to provide test signals in either standard. Selecting the PAL/NTSC menu will toggle the output standard between PAL and NTSC. Note that to use this method of selection the module must be operating in the Internal Lock mode set in the Genlock menu. If the operating standard is determined by either method (1) or (2) and is 625 line, PAL or SECAM can be selected as the output standard. If the operating standard is determined by either method (1) or (2) and is 525 line, NTSC will be selected as the output standard. If the signal input and reference input are of different line standards, the unit will output a black signal at the reference signal line rate. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.13

Genlock This sub-menu allows various modes of genlock to be enabled. Genlock Internal Zero_Sch_Lock SC_Phase H_Phase Internal When this function is enabled the output signal will be locked to the serial input (if available) or free-running if no serial input is available. In this mode the frequency accuracy will be ±10 ppm Notes: 1. This mode will be automatically enabled if the signal input and reference input are of different line standards and the output will default to black burst in the reference standard. 2. This mode should be selected if test patterns of a particular line standard (and different to the reference input) are required at the output. Zero_SC/H_Lock In this mode the module locks to the reference subcarrier and will always produce a zero ScH (Subcarrier phase to H-Phase) output. The output H timing will be maintained as close as possible to the reference H timing in the correct color frame. The ScH warning LED will light if the ScH error of the reference is > 20 (approx.), indicating that the color framing will be lost should the reference ScH error increase. Note that the output will always be 0 ScH phase regardless of the reference ScH phase. SECAM Genlock For SECAM the output will H phase to a PAL black or black-burst reference; Db/Dr phase is such that if the reference has a PAL burst, a V-Switch (Phase = 135 ) of burst on Line 1, Field 1 will produce a Dr line in the encoded output. If a SECAM reference signal is used the output Db/Dr sequence will be locked to that of the reference signal. SC_Phase This function allows the relative phasing between the reference subcarrier and the output signal subcarrier to be adjusted. SC_Phase SC_Phase 0.0 Deg Preset Rotating the spin-wheel will adjust this value and the numerical display shows the phasing in degrees. The range of adjustment is 359.9 (continuously adjustable) in steps of 0.1 and the preset value is 0 (Output coincident with reference) H_Phase Selecting this item reveals a display showing the horizontal timing of the output signal relative to the reference sync signal, in nanoseconds. Rotating the spin-wheel will adjust this value. H_Phase 0 ns Preset H_Phase The range is approximately ±1.9 lines in steps of one cycle of subcarrier. (This ensures the correct SC/H timing is maintained) Selecting Preset returns the setting to zero. (Output coincident with reference) Fine_H_Phase Fine_H_Phase Fine_H_Phase 0 ns Preset Note that when operating in the SECAM standard and genlock is selected a Fine Horizontal Phase control will become available. The range is approximately ±800 units in steps of 1 unit. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.14

Patterns This menu selection allows the unit to output test pattern signals. Patterns Pattern On MUTE BLACK 75% COLOUR BARS This function is enabled by selecting Pattern_On The desired pattern may then be selected. When Mute is selected there will be no signal of any kind at the output. EDH The input stream is continuously monitored for EDH errors. Basic information on this can be monitored and/or reset here. EDH 625 Show_Stats AutoDetect Reset_Stats The following functions may be selected: Show_Stats Reset_Stats Setup The information will be displayed in the LCD window Data will be reset This selection reveals a sub-menu that allows the following functions to be set up: Setup Insert_VITS Pass_Vertical_Data Pass_Line_23 SECAM_Options... RollTrack... Show_RT_Errors Preset_Unit Logging... Default Output... Software Version Serial_No Insert_VITS When this function is selected the four standard VITS lines are inserted in the vertical interval. The letters VTS will appear in the lower line of the control window when this is enabled. Pass_Vertical_Data When selected (text reversed) the unit will pass data (unblanked) present in the vertical interval, to the output. In 525 line standards all vertical interval lines from 11 and 274 onwards are passed with the exception of the half lines 263 and 283. In 625 line standards all vertical interval lines from 7 and 320 onwards are passed with the exception of the half lines 23 and 623. When de-selected (text normal) all data in the vertical interval will be blanked. Note that when this item is selected the word PVD will appear on the bottom line in the information window. Pass_Line_23 When selected the unit will pass the whole of line 23 (WSS Line) in PAL and PAL-N standards. When not selected only half of line 23 is passed in accordance with CCIR-624. Note that this control will have no effect in 525 line standards. SECAM_Options SECAM_Options 625 Notch_Filter AutoDetect Bottles Carrier_Off Chroma_Pre_Filter Notch_Filter When selected (text highlighted) the SECAM luminance notch filter will be enabled. Preset is to notch filter ON. Bottles This function allows the SECAM-V color ident signal (Bottles) to be switched ON (text highlighted) or OFF. Preset is to Bottles OFF. Carrier_Off This function allows the chrominance carrier to be switched ON or OFF (text highlighted) Preset is to ON. Chroma_Pre_Filter This function allows the chrominance filter to be switched ON (text highlighted) or OFF. Preset is to ON. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.15

RollTrack This function allows the value of the delay time produced by this module to be sent, via the RollCall network, to audio delay units connected on the same network. This enables compatible audio delay units to produce an audio delay dependent on this and other similar units. The audio delay unit will dynamically follow or track the received delay-time information allowing processed video signals to be timed correctly with audio signals. This automatic tracking system via the RollCall network is call RollTrack. For more detailed information, see the RollTrack section (Appendix) at the end of this manual. The destination for the delay information is set by the network code address as follows: Selecting RollTrack provides a sub-menu that allows up to 8 audio delays to be selected as a destination. Unit_1 Unit_3 Unit_5 Unit_7 RollTrack Unit_2 Unit_4 Unit_6 Unit_8 When a unit is selected a further sub-menu then appears to allow the code to be set up. The full network address has five sets of numbers. For example: 0000:10:01*14*51 The first set (0000) is the network segment code number The second set (10) is the number identifying the (enclosure/mainframe) unit The third set (01) is the slot number in the unit The fourth set (14) separated by an * is the channel number. Note that only channel numbers 14, 15, 16 & 17 should be used for audio delay cards. The fifth set (51) is the board type identification. Once a destination address for a unit has been set the OK function will return to the unit menu to allow another address to be set if required. For more detailed information see the RollTrack section of this manual. Show_RT_Errors Selecting this item will display any RollTrack messages/errors in the Information window. Unit _x 0000:00:0040 Clear Preset OK To edit the text the buttons adjacent to the upper text line in the menu are used to select the character position in the text and the spinwheel used to select the character. The code may be set up using the adjacent push buttons to edit the text. (The right and left buttons select the cursor position and the spinwheel selects the character; the clear button sets the text line to all zeros and the OK button accepts the network address) IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.16

Preset_Unit Selecting this item sets all adjustment functions that include a preset facility, to their preset values. Logging Logging Inp/Std_Change Ref_Loss EDH_Errors If a logging device is attached to the RollCall network, information about various parameters will be reported to the logging device assigned in the Remote Control Interface system. Inp/Std_Change When activated, a loss of input signal condition or change of input line standard will be available for the logging device. Ref_Loss Software_Version Selecting this item reveals a display showing the version of the software fitted in the module. Software Version Software_Version 5.6.6 OK Select OK to return to the Setup Menu. Serial No This displays the serial number of the unit. Serial No xxxxxxx Serial_No OK Select OK to return to the setup menu. When activated a loss of reference signal condition will be notified to any logging device. EDH_Errors When activated, EDH error information will be available for the logging device. Default Output Default Output MUTE BLACK 75% COLOUR BARS If the input signal fails or is of poor quality this function allows a signal to be selected to become the default output. When Mute is selected there will be no signal of any kind at the output. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.17

RollCall PC Control Panel Screens for the IQDMENCS Control This screen allows basic control functions to be setup. Standard This item allows the operating standard of the unit to be set. The operating line standard will be determined by the following detection method (in order of priority) 1. The reference input standard (input signal standard is ignored) when in Genlock mode 2. If there is no reference signal, by the input signal standard. 3. If there is no reference signal and no signal input the standard may be selected by using this menu. This allows the module to provide test signals in either standard. Selecting the PAL/NTSC menu will toggle the output standard between PAL and NTSC. Note that to use this method of selection the module must be operating in the Internal Lock mode set in the Genlock menu. If the operating standard is determined by either method (1) or (2) and is 625 line, PAL or SECAM can be selected as the output standard. If the operating standard is determined by either method (1) or (2) and is 525 line, NTSC will be selected as the output standard. If the signal input and reference input are of different line standards, the unit will output a black signal at the reference signal line rate. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.18

Control (continued) Test Pattern When checked the output will become the pattern selected by the Test Patterns screen. Insert VITS When this item is checked the four standard VITS lines are inserted in the vertical interval. The letters VTS will appear in the lower line of the control window when this is enabled. Pass Vertical Data When checked the unit will pass data (unblanked) present in the vertical interval, to the output. In 525 line standards all vertical interval lines from 11 and 274 onwards are passed with the exception of the half lines 263 and 283. In 625 line standards all vertical interval lines from 7 and 320 onwards are passed with the exception of the half lines 23 and 623. When unchecked all data in the vertical interval will be blanked. Note that when this item is selected the word PVD will appear on the bottom line in the information window. Pass Line 23 When checked the unit will pass the whole of line 23 (WSS Line) in PAL and PAL-N standards. When unchecked only half of line 23 is passed in accordance with CCIR-624. Note that this control will have no effect in 525 line standards. EDH Statistics The following functions may be selected: Show Stats Reset The information will be displayed in the information window. Data will be reset to zero. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.19

Genlock This screen allows various modes of genlock to be enabled. Genlock Modes Internal When this function is enabled the output signal will be locked to the serial input (if available) or free-running if no serial input is available. In this mode the frequency accuracy will be ±10 ppm Notes: 1. This mode will be automatically enabled if the signal input and reference input are of different line standards and the output will default to black burst in the reference standard. 2. This mode should be selected if test patterns of a particular line standard (and different to the reference input) are required at the output Scroll bars Note that for this and other screens the following applies: H Phase This item allows the horizontal timing of the output signal relative to the reference sync signal to be adjusted The range is approximately ±1.9 lines in steps of one cycle of subcarrier. (This ensures the correct ScH timing is maintained) Genlock (SECAM) The and symbols at the ends of the scroll bar allow the item to be adjusted in discrete steps. The symbol represents the Preset function and will return the function to the default setting. The numerical value is shown above the scroll bar. Zero_SC/H_Lock In this mode the module locks to the reference subcarrier and will always produce a zero ScH (Subcarrier phase to H-Phase) output. The output H timing will be maintained as close as possible to the reference H timing in the correct color frame. The ScH warning LED will light if the ScH error of the reference is > 20 (approx.), indicating that the color framing will be lost should the reference ScH error increase. Note that the output will always be 0 ScH phase regardless of the reference ScH phase. Note also that this item will become Genlock when the unit is operating in the SECAM standard. For SECAM the output will H phase to a PAL black or black-burst reference; Db/Dr phase is such that if the reference has a PAL burst, a V-Switch (Phase = 135 ) of burst on Line 1, Field 1 will produce a Dr line in the encoded output. If a SECAM reference signal is used the output Db/Dr sequence will be locked to that of the reference signal. Note that when operating in the SECAM standard and genlock is selected a Fine Horizontal Phase control will become available. The range is approximately ±800 units in steps of 1 unit. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.20

Test Patterns This screen allows the unit to output test pattern signals. This function is enabled by checking the Test Pattern box. The selected pattern will then become the output signal. When Mute is selected there will be no signal of any kind at the output. SECAM Options Notch Filter When selected the SECAM luminance notch filter will be enabled. Preset is to notch filter ON. Bottles This function allows the SECAM-V color ident signal (Bottles) to be switched or OFF. Preset is to Bottles OFF. Carrier Off This function allows the chrominance carrier to be switched ON or OFF. Preset is to ON. Chroma Pre Filter This function allows the chrominance filter to be switched ON or OFF. Preset is to ON. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.21

RollTrack This function allows the value of the delay time produced by this module to be sent, via the RollCall network, to audio delay units connected on the same network. This enables compatible audio delay units to produce an audio delay dependent on this and other similar units. The audio delay unit will dynamically follow or track the received delay-time information allowing processed video signals to be timed correctly with audio signals. This automatic tracking system via the RollCall network is call RollTrack. For more detailed information, see the RollTrack section (Appendix) at the end of this manual. To change the address, type the new destination in the text area and then select (return). (Preset) returns to the default destination. The destination for the delay information to one of eight units is set by the network code address as follows: The full network address has five sets of numbers. For example: 0000:10:01*14*51 The first set (0000) is the network segment code number The second set (10) is the number identifying the (enclosure/mainframe) unit The third set (01) is the slot number in the unit The fourth set (14) separated by an * is the channel number. Note that only channel numbers 14, 15, 16 & 17 should be used for audio delay cards. The fifth set (51) is the board type identification. For more detailed information see the RollTrack section of this manual. Show RollTrack Errors Selecting this item will display any RollTrack messages/errors in the Information window. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.22

Setup Selecting this item sets all adjustment functions that include a preset facility, to their preset values. Logging If a logging device is attached to the RollCall network, information about the checked parameters will be reported to the logging device assigned in the Remote Control Interface system. Default Output If the input signal fails or is of poor quality this function allows a signal to be selected to become the default output. When Mute is selected there will be no signal of any kind at the output. Software Version This item shows the version of the software fitted in the module followed by the serial number of the unit. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.23

Information Window The status of the unit is shown in abbreviated form in the information window. Information window The first item of the first line will show the status of the input. It may show: Inp: OK Inp: ERR Inp: ** A valid input has been detected. An input error has been detected. No input signal has been detected. The second item of the first line will show the line standard of the input. It may show: Std:PAL Std:NTSC Std:SECAM Std:Unknown A PAL standard has been detected. An NTSC standard has been detected. A SECAM standard has been detected. The standard is unknown The first item of the second line will show the status of the reference input. It may show: REF: OK A valid reference input has been detected. The second item of the second line will show EDH statistics. It may show: EDH:NONE EDH:Fail EDH:OK EDH:OK DW A valid reference input has been detected. A valid reference input has been detected. A valid reference input has been detected. This may be followed by a warning that the synchronizer delay has exceeded 1 ms. DW = Delay Warning. Line three will display setup messages: ZSC Genlock Zero SC/H Lock enabled If the text is static (not flashing) this indicates that the unit has successfully genlocked to the reference source. If the text is flashing this indicates that the unit is attempting to genlock to the reference source. REF: ** No reference input signal has been detected. GEN VTS SECAM Genlock Insert VITS enabled REF: SCE A subcarrier error hes been detected. e.g. a ScH error of >20. PVD PAT Pass Vertical Data enabled Pattern ON enabled IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.24

Appendix 1 Genlock The genlock will operate in one of two modes. The default mode (switches off), locks to the reference subcarrier and will always produce a zero ScH output. The output H timing will be maintained as close as possible to the reference H timing in the correct color frame. The ScH warning LED will light if the ScH of the reference is > ± 20 (approx.), indicating that color framing may be lost should the reference ScH error increase significantly. With no reference applied or internal lock selected the output will lock to the input D1 with the buffer delay set to a minimum. Incoming jitter will be suppressed and the output ScH is guaranteed to be zero. In the event of conflicting standards being applied to the reference and the D1 input the output will default to black burst in the reference standard. With no input or reference the output will also be black burst (or any available pattern) in a user selectable standard. In this mode the frequency accuracy will be ± 10ppm. In reference genlock modes the subcarrier may be offset by up to 360. H phase offset is limited to approx. ±1.9 lines. Genlock and delay limits (without comb option): Input D1 Output 0 µs to 1 Frame* Reference + 1.9 lines *An input to output delay of less than 3 µs will result in a frame of delay being inserted. The output will still be valid but audio delay compensation may be required. The delay warning (DW) message will appear if the overall input to output delay is between 1 ms and 1 frame. IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.25

RollTrack Audio Delay Tracking RollTrack is a feature of RollCall (Snell & Wilcox s proprietary remote control system), that allows devices to communicate across the RollCall network with no direct user intervention. RollTrack Audio Delay Tracking enables Snell & Wilcox RollCall compatible audio delay products to track delay introduced by RollCall compatible video processing products. The current products that implement RollTrack Audio Delay Tracking are: Audio Delay Modules Video Modules Other Products IQBAAD IQD1FSY ALCHEMIST MDD3000 IQBADC IQDMSDS CPP100 MDD550 IQBDAC IQDAFS CPP200 MDD560 IQBDAD IQDMSDS NRS500 MDD570 IQBSYN IQDMSDP HD5050 MDD2000 IQBADCD IQDSYN The simplest configuration is a single video unit and a single audio delay in a RollCall system. The audio delay will have the same delay as through the video path. If the delay changes the audio delay will track. 4:2:2 IQD1FSY delayed video by 10 ms RollCall connection Analogue Audio IQBADC delayed audio by 10 ms The next level of configuration is where there are multiple Frame Synchronizers (for example) each connected through RollCall to their own tracking Audio Delay. (It is worth stating that the synchronizers and audio delays do not have to be in the same enclosure; the addressing scheme, discussed later, allows for the units to be positioned anywhere in the RollCall domain.) The maximum number of video units and audio delays in a RollCall system is set by the maximum limit of the number of modules in a RollCall network and is currently 3840 on a single network without bridges. The unique identification of the destination unit (a decimal number) for various modules is as follows: ID Module IQBADC 51 IQBDAC 52 IQBAAD 53 IQBDAD 54 IQBSYN 89 IQBADCD 107 IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.26

The next level of complexity is a vertical delay cluster where a video unit can have up to eight audio delays tracking - of the same or different types. 4:2:2 IQD1FSY delayed video by 10 ms changes to 20 ms RollCall network connection Analogue Audio IQBADC delayed audio by 10 ms tracks to 20 ms Analogue Audio IQBAAD delayed audio by 10 ms tracks to 20 ms From one to eight audio delay products can be connected via RollCall to a single frame synchronizer, for example. If the synchronizer delay changes, then however many audio delays are connected will track the delay. The audio delays can also have a manual delay which will be added to the RollTrack delay. The next level of complexity is a horizontal delay cluster where an audio delay can track up to four video units. IQDMSDA IQD1FSY IQD1FSY IQD1FSY 1 2 3 4 IQBADC m (= manual delay set in the BADC) Total delay: RollCall network connection Τ=== ς 1 4==+= m IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.27

The total delay time through the audio delay is then the sum of the individual delays introduced by the video units plus the manual delay of the audio unit. The manual delay can be set to compensate for any fixed propagation delay in the video path or may be set to zero. The next level of complexity is a matrix delay cluster where each audio delay (up to eight) can track up to four video units. This configuration is in effect a four by eight matrix of video units and audio delay units. The total delay time through the audio delay units is then the sum of the individual delays introduced by the video units plus the manual delay of the audio unit. IQDMSDA IQD1FSY IQD1FSY IQD1FSY 1 2 3 4 RollCall network i IQBDAD 1 Τ=== ς 1 4==+= m IQBDAD 8 Τ=== ς 1 4==+= m As any of the delay times change in the video path so will the audio delay time track this delay. A virtual connection is made between from, say, an IQD1FSY to an IQBDAD by: selecting the Setup... Menu of the IQD1FSY then selecting the Audio_Delay... Menu then choosing from Unit_1 to Unit_8 then entering the unique network address of the IQBDAD in the form nnnn:xx:yy*z*d where nnnn = network address and in most cases will be 0000(hex); xx = IQ enclosure address (hex); yy = slot address of the IQBDAD (hex) z = the connection (or channel) number (decimal) - see table below. d = the unique identification of the destination unit (decimal) The ID entered must match the receiving units own ID or else the command will be ignored. If the ID value is set to 00, the receiving unit does not perform an ID match and will always accept the incoming command then selecting the Delay... Menu of the IQBDAD then selecting RollTrack Example of Network Addresses with Channel Numbers and ID Numbers D1FSY 1 D1FSY 2 D1FSY 3 D1FSY 4 Audio delay 1 0000:10:01*14*54 0000:10:01*15*54 0000:10:01*16*54 0000:10:01*17*54 Audio delay 2 0000:10:03*14*54 0000:10:03*15*54 0000:10:03*16*54 0000:10:03*17*54 Audio delay 3 0000:10:05*14*54 0000:10:05*15*54 0000:10:05*16*54 0000:10:05*17*54 Audio delay 4 0000:10:07*14*54 0000:10:07*15*54 0000:10:07*16*54 0000:10:07*17*54 Audio delay 5 0000:10:09*14*54 0000:10:09*15*54 0000:10:09*16*54 0000:10:09*17*54 Audio delay 6 0000:10:0B*14*54 0000:10:0B*15*54 0000:10:0B*16*54 0000:10:0B*17*54 Audio delay 7 0000:10:0D*14*54 0000:10:0D*15*54 0000:10:0D*16*54 0000:10:0D*17*54 Audio delay 8 0000:10:0F*14*54 0000:10:0F*15*54 0000:10:0F*16*54 0000:10:0F*17*54 IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.28

The most complex system would be an array of matrix delay clusters IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.29

IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.30

Manual Revision Record Date Version No. Issue No. Change Comments 030400 1 1 First Issue 280302 1 2 Now includes information for the 3A enclosure modules New manual issued 160502 1 3 Changes/additions to rear panels New manual issued 271102 1 4-2A-S rear panel added New manual issued 100403 1 5 Power consumption added to techspec 040304 1 6 For version 5.6.6 Pass Line 23, default output, mute added. New manual issued New manual released IQDMENCSOPS 040304 www.snellwilcox.com Version 1 Issue 6 11b.31