ODW-621. RS-232 Point-to-point applications

Similar documents
Fibre Optic Modem ODW-622

Fibre Optic Modem ODW-611

LONWORKS Fibre Optic Converter

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Router

Rack mounted telephone- and leased line modem for industrial applications

LRW-102. Fibre Optic industrial converter/repeater for LonWorks TP/FT-10 point-to-point, line and redundant ring. User Guide

ODW-612 Fibre Optic Modem

ODW-610-F2. Industrial Converter PROFIBUS DP to Fibre Optic Link Repeater, line and redundant ring. Fibre Optic Modem. User Guide

User Guide. Westermo Teleindustri AB 2005 MCW Industrial Ethernet Media Converter.

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

FOM-9010, FOM-9011 and FOM-9012

One channel video link With duplex data and contact closure

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

I/A Series Hardware Fiber Optic LAN Converter

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Ethernet Media Converters

1550 nm TX / 1310 nm RX / 3 Gb/s Medium Power 1-Fibre SM Video SFP Transceiver

Dual Fiber SFP Series

Single mode 9/125µm, duplex

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

LTC 46xx and LTC 47xx Series Fiber Optic Transmission Units

Power (dbm) λ (nm) LINK DISTANCE SDI Bit Rate Max. Link Distance (km) 3G-SDI 2.97Gbps 30 HD-SDI 1.485Gbps 30 SD-SDI 270Mbps 30

Industrial 10/100 Base-TX to 100 Base-FX Media Converter NS-200AFC-T/NS-200AFCS-T/NS-200AFCS-60T +12 ~ +48

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

Selection of a cable depends on functions such as The material Singlemode or multimode Step or graded index Wave length of the transmitter

10G SFP+ Modules. 10G SFP+ Module Series

DVO700 P FIBRE OPTIC TRANSMITTER

IES-3162GC. >> Industrial 18-port Managed Ethernet Switch with 16x10/100Base-T(X) Ports and 2xGigabit combo ports. Industrial Ethernet Switch

Accessories EXP1 - cards to 19 rack extending the number of 1Vpp outputs to 3 at one-input cards

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

Product Specification XFP 10G LR 20km LC Optical Transceiver

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

LTC 4600 and 4700 Series Fiber Optics

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

FOM-1090 FOM-1090 FOM FOM-1090 w/ DB-25 Female FOM-1091 w/ DB-25 Male

CWDM / 3 Gb/s Medium Power SM Video Digital Diagnostic SFP Transceiver

SHQP28-100G-LR4-B. 103/112Gb/s QSFP28 Transceiver Hot Pluggable, Duplex LC, +3.3V, 1310nm DML/PIN, Single mode, 10km, 0~70 C

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Type SCH94FO. Type SCH94FO. Description

Single Fiber SFP Series

DATA SHEET. Optical FireWire Repeater M4-200 & M4-201

EDS-G205-1GTXSFP/G308 Series

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

AddOn Computer s SFP transceivers are RoHS compliant and lead- free.

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

Ordering Information. Industrial Ethernet Solutions

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions.

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. June 2015 Part Numbers FIBER DRIVER

EDS-G205/G308 Series. 5G and 8G-port full Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

02/11/2015

SECTION 683 VIDEO OPTICAL TRANSCEIVER WITH BI-DIRECTIONAL DATA CHANNEL DESCRIPTION

MAXCOM PRODUCT SPECIFICATIONS FIBER OPTIC VIDEO / AUDIO / ASI LINK. Model MX3257HD. Description. Features. Model Selection Guide

SH2RE16A4. Output relay module. Benefits. Description

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

1 inputs / Optical signal for extension - Dot clock: 25 MHz to 600MHz - TMDS clock: 25 MHz to 300 MHz Video. - TMDS Single Link

E3/DS3 Fibre Extender

Specifications PowerCage 1600 System

10Gbps SFP+ Optical Transceiver, 10km Reach

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

10G- XFP- LR- AO. 10Gbs XFP Transceiver

HDO701 FIBRE OPTIC TRANSMITTER

DATA SHEET. Digital Video/Analogue Audio Optical Extender M1-203D-TR

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

CWDM / 3 Gb/s Medium Power Optical SM Digital Diagnostic Transmitter/Receiver FVD2-1TR-SM30-XX

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

10G- XFP- SR- AO. 10Gbs XFP Transceiver

Magnetic Sensor - Incremental EHP

DVM-3000 Series 12 Bit DIGITAL VIDEO, AUDIO and 8 CHANNEL BI-DIRECTIONAL DATA FIBER OPTIC MULTIPLEXER for SURVEILLANCE and TRANSPORTATION

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

10G BiDi XFP 10km Optical Transceiver GBX-xxxx192-LRC

LoopBack Relay. SGLB363 Series. With Built-in AC Bypass Capacitors / DC LoopBack Relay

Process Transmitter RMA 422

CFMFFxxxx-2xx User s Guide Slide-in-Module Media Converter Fast Ethernet, ATM, SONET, or Gigabit

HD-3500 Series. HD Video, Audio, Data & Tally/GPIO Channels FEATURES

T A S A 2 N B 1 F A H

EDS-210A Series. 8+2G/9+1G-port Gigabit unmanaged Ethernet switches. Introduction. Specifications. Industrial Ethernet Solutions

Model FS-4608R. Features. Overview

PRODUCT SPECIFICATION Date: VESTEL

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

FTS-M12G-S85L-55M. SFP 1000Base-SX, 850nm, multi-mode, 550m

10Gbps 10km Range SFP+ Optical Transceiver

User s Guide F-SM-MM-02 Stand-Alone Media Converter Fast Ethernet or ATM Singlemode to Multimode

Transcription:

Re-timing Data rate up to 250 kbit/s 9-position D-sub connector Redundant power supply inputs Status interface for fault indication Fibre link fault indication (Red) Design for harsh environments 40 to +70 C operating temperature ODW-621 RS-232 Point-to-point applications The ODW-621 is designed for point-to-point applications between devices with an RS-232 interface. The ODW-621 is designed for harsh industrial usage as well as road or railway installations meeting industrial level EMC specifi cations and having a wide operating temperature range. The maximum distance of the fi bre link depends on selected transceiver and fi bre type. Fibre distances up to 80 km (50 miles) are possible using singlemode fi bre. The unit also has a re-timing function that eliminates the problem of jitter and hence ensures reliable communications in all situations. It is possible to use the ODW-621 in conjunction with the ODW-631 to provide protocol conversion from RS-232 to RS-422/485 at either end of the optical link. The ODW-621 can also be used in start/end points in a multidrop application together with ODW-632 / 622. 12 www.westermo.com

ODW-Series Technical data Power Rated voltage Operating voltage 12 to 48 VDC 24 VAC 10 to 60 VDC 20 to 30 VAC* Rated current ODW-611/621/631 300 ma @ 12 VDC 150 ma @ 24 VDC 75 ma @ 48 VDC ODW-612/622/632 400 ma @ 12 VDC 200 ma @ 24 VDC 100 ma @ 48 VDC Rated frequency DC: 0 Hz AC: 48 to 62 Hz Inrush current I 2 t 0.2 A 2 s Startup current** 1.0 Apeak Polarity Polarity independent Redundant power input Yes Serial port and Status port Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24-12) Not required * Not available on ODW-611/612 ** External supply current capability for proper startup Status Port type Signal relay, changeover contacts Rated voltage Up to 48 VDC Operating voltage Up to 60 VDC Contact rating 500 ma @ 48 VDC Contact resistance < 50 mω Serial port and Power port Detachable screw terminal Connector size 0.2 2.5 mm 2 (AWG 24 12) Not required LC-connectors SFP (Small Form-Factor Pluggable) LC-2 Multimode up to 5 km (3.1) LC-40 Singlemode up to 40 km (25 mi) LC-15 Singlemode up to 15 km (9.3 mi) LC-80 Singlemode up to 80 km (50 mi) 16 www.westermo.com

RS-232 Electrical specification Data rate Data format Protocol Re-timing Deviation, Input data rate Transmission range Conductive housing EIA RS-232 300 bit/s 250 kbit/s 9 12 bits (Protocol dependent mode) Arbitrary (Transparent mode) Start-bit followed by 8 11 bits (Protocol dependent mode) Arbitrary (Transparent mode) Yes (Protocol dependent mode) Byte: 4%; Bit 49% (Protocol dependent mode) 15 m Status and Power port 9-pin D-sub female (DCE) Not required, except when installed in railway applications as signalling and telecommunications apparatus and located close to rails* Isolated to all other circuits and housings * To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m boundary to the rails and connected to this port. The cable shield should be properly connected (360 ) to an earthing point within 1 m from this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth. RS-422/485 Electrical specification Data rate Data format Protocol Re-timing Deviation, Input data rate Turning time (2-wire RS-485) Transmission range Settings EIA RS-485, 2-wire (PROFIBUS DP) or EIA RS-422, 4-wire twisted pair 300 bit/s 1.5 Mbit/s, RS-422/485 9 600 kbit/s 12 Mbit/s, PROFIBUS DP 9 12 bits (Protocol dependent mode) Arbitrary (Transparent mode) Start-bit followed by 8 11 bits (Protocol dependent mode) Arbitrary (Transparent mode), RS-422/485 PROFIBUS DP (RS-485) Yes (Protocol dependent mode, RS-422/485) Byte: 4%; Bit 49% (Protocol dependent mode) One t bit t bit = 1 / Baud rate (Baud rate in bit/s) In accordance with EN 50 170, PROFIBUS DP < 1200 m, depending on data rate and cable type (EIA RS-485) 120 Ω termination and failsafe biasing 680 Ω, RS-422/485 None, external termination and failsafe biasing, PROFIBUS DP Protection Installation Fault Tolerant (up to ±60 V) Status and Power port Detachable screw terminal, RS-422/485 9-pin D-sub female, PROFIBUS DP Connector size 0.2 2.5 mm 2 (AWG 24 12) Not required www.westermo.com 17

Type tests and environmental conditions for the ODW-series Electromagnetic Compatibility Phenomena Test Description Level ESD EN 61000-4-2 Enclosure contact ± 6 kv Enclosure air ± 8 kv RF field AM modulated IEC 61000-4-3 Enclosure 20 V/m 80% AM (1 khz), 80 2000 MHz RF field 900 MHz ENV 50204 Enclosure 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz Fast transient EN 61000-4-4 Signal ports ± 2 kv Power ports ± 2 kv Surge EN 61000-4-5 Signal ports unbalanced ± 2 kv line to earth, ± 2 kv line to line Signal ports balanced ± 2 kv line to earth, ± 1 kv line to line Power ports ± 2 kv line to earth, ± 2 kv line to line RF conducted EN 61000-4-6 Signal ports 10 V 80% AM (1 khz), 0.15 80 MHz Power ports 10 V 80% AM (1 khz), 0.15 80 MHz Power frequency EN 61000-4-8 Enclosure 100 A/m, 50 Hz, 16.7 Hz & 0 Hz magnetic field Pulse Magnetic field EN 61000-4-9 Enclosure 300 A/m, 6.4 / 16 μs pulse Voltage dips and interruption EN 61000-4-11 AC power ports 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction Mains freq. 50 Hz EN 61000-4-16 Signal ports 100 V 50 Hz line to earth Mains freq. 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000-4-29 DC power ports 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & 20% below rated voltage Radiated emission EN 55022 Enclosure Class B FCC part 15 Class A Conducted emission EN 55022 AC power ports Class B FCC part 15 AC power ports Class A EN 55022 DC power ports Class B Dielectric strength EN 60950 Signal port to all other isolated ports 2 kvrms 50 Hz 1min Power port to other isolated ports 3 kvrms 50 Hz 1min 2 kvrms 50 Hz 1min (@ rated power < 60V) Environmental Temperature Operating 40 to +70 C Storage & Transport 40 to +70 C Humidity Operating 5 to 95% relative humidity Storage & Transport 5 to 95% relative humidity Altitude Operating 2 000 m / 70 kpa Service life Operating 10 year Vibration IEC 60068-2-6 Operating 7.5 mm, 5 8 Hz 2 g, 8 500 Hz Shock IEC 60068-2-27 Operating 15 g, 11 ms Packaging Enclosure UL 94 PC / ABS Flammability class V-1 Dimension W x H x D 35 x 121 x 119 mm Weight 0.26 kg Degree of protection IP 21 Cooling IEC 529 Enclosure Convection Mounting Horizontal on 35 mm DIN-rail 18 www.westermo.com

Optical Power Budget for the ODW-series The maximum supported link lengths as specified in table below should only been seen as indicative. The allowed link length is calculated from the Optical Power Budget (OPB), the available optical power for a fibre optic link, and the attenuation of the fibre, comprising losses due to in-line connectors, splices, optical switches and a margin for link aging (typical 1.5 db for 1300 nm). The worst-case Optical Power Budget (OPB) in db for a fibre optic link is determined by the difference between the minimum transmitter output optical power and the lowest receiver sensitivity. FX (Fibre) SM-LC80 SM-LC40 SM-LC15 MM-LC2 Fibre connector LC duplex LC duplex LC duplex LC duplex Fibre type Singlemode 9/125 μm Singlemode 9/125 μm Singlemode 9/125 μm Multimode, 62.5/125 and 50/125 μm Wavelength 1550 nm 1310 nm 1310 nm 1310 nm Transmitter 5/0 dbm** 5/0 dbm** 15/ 8 dbm** 20/ 14 dbm* Output optical power min/max Receiver 34 dbm 34 dbm 31 dbm 31 dbm Input sensitivity, max Receiver 5 dbm*** 3 dbm*** 8 dbm 8 dbm Input optical power, max Optical power budget, worst-case 29 db 29 db 16 db 11 db Bit error rate (BER) < 1 x 10-10 < 1 x 10-10 < 1 x 10-10 < 2.5 x 10-10 Transceiver type Laser class Small Form-Factor Pluggable (SFP) Multi-Sourcing Agreement (MSA) compliant Class 1, IEC 825-1 Accessible Emission Limit (AEL) * Output power is power coupled into a 62.5/125 μm multimode fibre ** Output power is power coupled into a 9/125 μm singlemode fibre *** The use of attenuation is recommended on short fibre lengths. 5dB (SM-LC80) and 3dB (SM-LC40) Power budget for the LR-series Minimum budget Fibre 820 nm Singlemode 50/125 10.7 db 62,5/125 14.5 db 100/140 20.6 db 9/125 6.3 db Typical Budget 50/125 16.6 db 62,5/125 18.6 db 100/140 25.9 db 9/125 12.3 db Min. budget states the minimum guaranteed power budget. Experience shows however that the typical value is in the range of the indicated Typ. budget. www.westermo.com 19

ODW-6xx-xx-xx Type of Transceiver LC2 (Multimode) LC15 (Singlemode) LC40 (Singlemode) LC80 (Singlemode) Bi-Di (Singlemode) Type of cable SM, Singlemode MM, Multimode Type of Interface / Protocol x1x = PROFIBUS DP x2x = RS-232 x3x = RS-422 / 485 Type of application xx1 = Point-to-point xx2 = Multidrop / Ring Different transceivers on the same modem The ODW-xx2 modems allow for fl exible transceiver confi guration (LC15 and LC40 for instance). In order to get the installation to work is it of the utmost importance that transceivers are mounted in the right position / channel. For example in a ring application channel 1 must be connected to channel 2. In a multidrop application channel 1 should be connected to channel 2 except in the end unit where channel 1 should be used. ODW-6xx-xx / xx-xx Channel Channel 2 Channel 1 www.westermo.com 23