Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as a industrial /-wire leased line modem. V. provides speeds up to.6kbit/s on the communication line. Several features make it ideal for use in industrial applications: Password protection, dial-back security and caller ID answering are only some of this features. For redundant use, the PSTN dial backup function is useful. In case of a leased line failure, the modem will establish a dial backup link. The modem has both RS- and RS-85/ interfaces allowing it to be used in many different applications. All connections are accessible from the back of the 9 -card. The TR-6 is the ideal choice for industrial dial-up and / wire leased line applications where many modems need to be installed in a small amount of space. Configuration and diagnostics The TR-6 is configurable via its serial interface in different ways, either via standard terminal emulation software using AT-Hayes commands or Westermo s own modem configuration software - TD-Tool. Additionally the TR-6 can be configured via its onboard DIP-switches. TD-Tool is a Windows based configuration GUI that simplifies setting up the modems, connection statistics can be viewed and configurations saved for further use. To assit in fault finding and reconfiguration of unmanned stations, the modem can be configured remotely via a PSTN connection. Harsh industrial environment The TR-6 is designed to function reliably within industrial environments and in areas of high level interference. The modem is equipped with transient protection on the line side and a watchdog that monitors and automatically resets the modem in the event of a fault. The TR-6 is designed to be mounted in Westermo s RV-07 9 rack which can hold up to 7 TR-6 modems. Approvals The construction of the units has gone through extensive testing and approvals both by Westermo and approved test houses. The TR-6 is approved for use in Europe. Industrial PSTN Modems AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr
Application Telephone network Leased Line Interfaces DIP-switches LEDs Jack socket Headphones can be fitted to listen to the line quality. RS-/V. (9-pos. D-sub) Speeds up to 5. kbit/s RS-/85 (screw terminal) Speeds up to 5. kbit/s Line connection, dial-up (screw terminal) Speeds up to.6 kbit/s Power supply on RV-07 PS-0 HV External 8 DC Operating voltage 90 6 VAC / 99 00 VDC 8 VDC Rated current 5 ma @ 6 VDC 90 ma @ VDC (fully equipped rack with 7 modems) Rated frequency 8 6 Hz / DC DC Detachable x -pos. screw terminal Detachable -pos. screw terminal Applications, interfaces AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr
Technical Data Power RV-07, 7 pcs TR-6, PS-0 HV Power supply 0 50 VDC +0 / 0% 5 0 VAC +5 / 0% Power consumption 500/0 ma, 50 W Rated frequency DC / 8 6 Hz Fuse, F AS 5x 0 mm Isolation to All other ports kvrms 50 Hz min * Direction relative this unit Power RV-07, 7 pcs TR-6, ext 8 VDC Power supply 8 VDC Power consumption W Rated frequency DC Isolation to All other ports.5 kvrms 50 Hz min ** * Direction relative this unit ** Maximum wire length to external power supply < 0 m. Public Switched Telephone Network (PSTN) Electrical specification Public Switched Telephone Network 00 bit/s.6 kbit/s B0, B, V, V, VB, VC, V HDX, V, VB, V Protection Installation Fault Tolerant (up to ±60 V) Isolation to Power port kvrms 50 Hz min Leased Line kvrms 50 Hz min RS- kvrms 50 Hz min RS-85 kvrms 50 Hz min I/O kvrms 50 Hz min RJ-C and Connector size AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr
Leased Line (LL) Electrical specification - or -wire Leased Line 00 bit/s.6 kbit/s B0, B, V, V, VB, VC, V HDX, V, VB, V Transmission range PSTN 0 db Budget Leased Line max 0 db Protection Installation Fault Tolerant (up to ± 60 V) Isolation to Power port kvrms 50 Hz min Leased Line kvrms 50 Hz min RS- kvrms 50 Hz min RS-85 kvrms 50 Hz min RS-/85 Electrical specification EIA/TIA-85 ITU V. -wire or -wire twisted pair 00 bit/s 5. kbit/s Data format 7 or 8 data bits, Odd, even or none parity, or stop bits, Σ 9- bit words Transparent Retiming Yes Turn around time <0 µs (half duplex) Transmission range 00 m, depending on data rate and cable type (EIA RS-85) Settings 0 W termination and failsafe biasing 680 W Protection Installation Fault Tolerant (up to ±60 V) Isolation to Power port kvrms 50 Hz min PSTN Line kvrms 50 Hz min Leased Line kvrms 50 Hz min Galvanic connection to RS- Connector size 0..5 mm (AWG ) * Miscellaneous Do not connect RS- and RS-/85 simultaneously AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr
RS- Electrical specification EIA/TIA- 00 bit/s 5. kbit/s Data format 7 or 8 data bits, Odd, even or none parity, or stop bits, Σ 9- bit words Transparent Retiming Yes Transmission range Cable length 5 m Isolation to Power port kvrms 50 Hz min PSTN Line kvrms 50 Hz min Leased Line kvrms 50 Hz min 9-pin D-sub female (DCE) and (DCE ) Connector size 0..5 mm (AWG ) * Conductive housing Isolated to all others circuits Miscellaneous Do not connect RS- and RS-/85 simultaneously * Railway installation close to the rails. For a cable located within m and connected to this port, the use of shielded cable is recommended, this is to minimise the risk of interference. The cable shield should be properly connected (60 ) to an earthing point within m of this port. This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is builtin. This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth. AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr
Type tests and environmental conditions Electromagnetic Compatibility Phenomena Test Description Test levels ESD EN 6000-- Enclosure contact ± 6 kv Enclosure air ± 8 kv RF field AM modulated IEC 6000-- Enclosure 0 V/m 80% AM ( khz), 80 000 MHz 0 V/m 80% AM ( khz), 80 000 MHz RF field 900 MHz ENV 500 Enclosure 0 V/m pulse modulated 00 Hz, 900 ± 5 MHz Fast transient EN 6000-- Signal ports ± kv Power ports ± kv Surge EN 6000--5 Signal ports ± kv line to earth, ± kv line to line unbalanced Signal ports balanced ± kv line to earth, ± kv line to line Power ports ± kv line to earth, ± kv line to line RF conducted EN 6000--6 Signal ports 0 V 80% AM ( khz), 0.5 80 MHz Power ports 0 V 80% AM ( khz), 0.5 80 MHz Power frequency magnetic field EN 6000--8 Enclosure 00 A/m, 50 Hz, 6.7 Hz & 0 Hz Pulse magnetic field EN 6000--9 Enclosure 00 A/m, 6. / 6 ms pulse Voltage dips and interruption EN 6000-- AC power ports 0 & 5 000 ms, interruption 0 & 500 ms, 0% reduction 00 & 000 ms, 60% reduction Mains freq. 50 Hz EN 6000--6 Signal ports 00 V 50 Hz line to earth Mains freq. 50 Hz SS 6 5 0 Signal ports 50 V 50 Hz line to line Voltage dips and interruption EN 6000--9 DC power ports 0 & 00 ms, interruption 0 ms, 0% reduction 0 ms, 60% reduction +0% above & 0% below rated voltage Radiated emission EN 550 Enclosure Class B Conducted emission EN 550 AC power ports Class B EN 550 DC power ports Class B Dielectric strength EN 60950 Signal port to other isolated ports kvrms 50 Hz min Power port to other isolated ports kvrms 50 Hz min kvrms 50 Hz min (@ rated power <60 V) Environmental Temperature Operating 0 to +50ºC Storage & Transport 5 to +70ºC Humidity Operating 5 to 95% relative humidity non condensing. Storage & Transport 5 to 95% relative humidity non condensing. Altitude Operating 000 m / 70 kpa Reliability prediction (MTBF) MIL-HDBK- 7F Operating Service life Operating 0 year Packaging Enclosure Dimension W x H x D 85 x 5 x 80 mm Weight TR-6 0. kg Weight Total kg (7 TR-6 + PS-0) Degree of protection IEC 59 Enclosure IP 0 Cooling Convection Mounting 9 rack AUDIN - 8, avenue de la malle - 570 Saint Brice Courcelles Tel : 0.6.0.0. - Fax : 0.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr