JLab 10kW FEL Driver Beam Diagnostics

Similar documents
Jefferson Lab Experience with Beam Halo, Beam Loss, etc.

Operational Experience with Jefferson Lab ERL/FEL Machine Protection System (MPS) Kevin Jordan & the FEL Team October 18, 2011

Linac 4 Instrumentation K.Hanke CERN

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

Performance of a DC GaAs photocathode gun for the Jefferson lab FEL

FEL TEST PLAN WORKSHEET

Photo cathode RF gun -

Screen investigations for low energetic electron beams at PITZ

4.4 Injector Linear Accelerator

Summary of the 1 st Beam Line Review Meeting Injector ( )

An Overview of Beam Diagnostic and Control Systems for AREAL Linac

New Filling Pattern for SLS-FEMTO

AN OPTICAL AND TERAHERTZ INSTRUMENTATION SYSTEM AT THE FAST LINAC AT FERMILAB*

BUNCH-COMPRESSOR TRANSVERSE PROFILE MONITORS OF THE SwissFEL INJECTOR TEST FACILITY

TESLA FEL-Report

Hall-B Beamline Commissioning Plan for CLAS12

Summary report on synchronization, diagnostics and instrumentation

Non-Invasive Energy Spread Monitoring for the JLAB Experimental Program via Synchrotron Light Interferometers

Future Performance of the LCLS

An Operational Diagnostic Complement for Positrons at CEBAF/JLab

Linac-Beam Characterizations at 600 MeV Using Optical Transition Radiation Diagnostics *

P. Emma, et al. LCLS Operations Lectures

Beam Instrumentation for X-ray FELs

Simulations on Beam Monitor Systems for Longitudinal Feedback Schemes at FLASH.

Beam Instrumentation for CTF3 and CLIC

Extraction/Separator Setup. Michael Spata Operations Stay Treat July 16, 2015

Digital BPMs and Orbit Feedback Systems

Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

LCLS RF Reference and Control R. Akre Last Update Sector 0 RF and Timing Systems

TITLE PAGE. Title of paper: PUSH-PULL FEL, A NEW ERL CONCEPT Author: Andrew Hutton. Author Affiliation: Jefferson Lab. Requested Proceedings:

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

Photoinjector Laser Operation and Cathode Performance

High Brightness Injector Development and ERL Planning at Cornell. Charlie Sinclair Cornell University Laboratory for Elementary-Particle Physics

3 cerl. 3-1 cerl Overview. 3-2 High-brightness DC Photocathode Gun and Gun Test Beamline

North Damping Ring RF

PEP II Design Outline

Development of BPM Electronics at the JLAB FEL

Current status of XFEL/SPring-8 project and SCSS test accelerator

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

Detailed Design Report

CERN S PROTON SYNCHROTRON COMPLEX OPERATION TEAMS AND DIAGNOSTICS APPLICATIONS

THE NEXT LINEAR COLLIDER TEST ACCELERATOR: STATUS AND RESULTS * Abstract

CLIC Feasibility Demonstration at CTF3

Status of SOLARIS Arkadiusz Kisiel

SPEAR 3: Operations Update and Impact of Top-Off Injection

PROJECT DESCRIPTION. Longitudinal phase space monitors for the ILC injectors and bunch compressors

A Cathode Development Cornell Cultera This scope includes all labor and purchases required produce photocathodes required by CBETA.

Activities on FEL Development and Application at Kyoto University

30 GHz Power Production / Beam Line

High-Power Setup Procedure

CBF500 High resolution Streak camera

LHC Beam Instrumentation Further Discussion

Status of RF Power and Acceleration of the MAX IV - LINAC

FEL Gun Test Stand (GTS) from construction to beam operations

PHGN 480 Laser Physics Lab 4: HeNe resonator mode properties 1. Observation of higher-order modes:

Week 0: PPS Certification and Processing. Mon Feb 11 Tue Feb 12 Wed Feb 13 Thu Feb 14 Fri Feb 15 Sat Feb 16 Sun Feb 17

Diamond RF Status (RF Activities at Daresbury) Mike Dykes

LCLS-II Injector Tuning Procedures. F. Zhou (SLAC) & F. Sannibale (LBNL) 2/6/2017

G0 Laser Status Parity Controls Injector Diagnostics

SRS and ERLP developments. Andrew moss

Accelerator Instrumentation RD. Monday, July 14, 2003 Marc Ross

Precision measurements of beam current, position and phase for an e+e- linear collider

Progress of Beam Instrumentation in J-PARC Linac

LCLS Injector Technical Review

PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND. Doug Roberts U of Maryland, College Park

Compact, e-beam based mm-and THzwave light sources

Challenges in Accelerator Beam Instrumentation

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

PITZ Introduction to the Video System

ARIEL e-linac Machine Protection System Requirements

Upgrading LHC Luminosity

EPJ Web of Conferences 95,

Status of CTF3. G.Geschonke CERN, AB

Jae-Young Choi On behalf of PLS-II Linac team

High Rep Rate Guns: FZD Superconducting RF Photogun

PEP II STATUS AND PLANS *

Design Studies For The LCLS 120 Hz RF Gun Injector

Soft x-ray optical diagnostics, concepts and issues for NGLS

RUNNING EXPERIENCE OF FZD SRF PHOTOINJECTOR

Top-Up Experience at SPEAR3

SSRF Beam Diagnostics Commissioning. LENG Yongbin on behalf of SSRF BI group

Requirements for the Beam Abort Magnet and Dump

Accelerator Systems of the TPS

Development of an Abort Gap Monitor for High-Energy Proton Rings *

The FLASH objective: SASE between 60 and 13 nm

Status of the X-ray FEL control system at SPring-8

The FAIR plinac RF Systems

PEP-II Overview & Ramp Down Plan. J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

Suppression of Timing drift between laser and electron beam driven photo-cathode RF gun

DELIVERY RECORD. Location: Ibaraki, Japan

Beam Losses During LCLS Injector Phase-1 1 Operation

KARA and FLUTE RF Overview/status

STATUS OF THE SWISSFEL C-BAND LINEAR ACCELERATOR

A Fifteen Year Perspective on the Design and Performance of the SNS Accelerator

Beam Loss Detection for MPS at FRIB

Present Status and Future Upgrade of KEKB Injector Linac

The PEFP 20-MeV Proton Linear Accelerator

Transcription:

JLab 10kW Driver Beam Diagnostics Kevin Jordan, S. V. Benson, J. Coleman, D. Douglas, R. Evans, A. Grippo, D. Gruber, G. Krafft, W. Moore, N. Nishimori, P. Piot, D. Sexton, J. Song and S. Zhang

Outline. Philosophy. Beam Viewers. Beam Position Monitors. Synchrotron Light Monitors. Beam Loss Monitors. Bunch Length Monitors. Streak camera measurements. Happek Interferometer. M55 Bunch length & curvature. THz Spectrometer. Emittance Measurements. Quad Scan Technique. Multislit monitor. WesCam Frame Grabber System. Analog Monitoring System and Video Distribution. Conclusions

Philosophy. Leave the bunch long (especially out of injector) then compress at wiggler. Recompress during energy recovery. Limit shunt impedance of beam line componants. Shield all devices viewers, bellows. Minimize radiation. HUGE apertures; 15% energy acceptance. Use as thin as possible Al foil for OTR viewers. Maximize use of non-invasive diagnostics. Install synchrotron light ports wherever possible. Beam Loss Monitors are crucial for machine setup. Monitor RF gradient & phases (GASK/PASK) through linac to setup path length. Analog Monitoring System (AMS) and Video System allow operator instant access to RF phases and gradients, BLM analog outputs, and a host of other signals throughout the accelerator (put a camera on it & patch it back)

10 kw IR Driver Accelerator Recirculator Machine is 433 nsec or 129.81 meters long Large magnets designed for operations to 210 MeV Max energy to date is 165 MeV Max current to date is 9.1 milliamp CW Max recirculated electron beam power 1.6 MW

Beam Viewers. Variety of flag materials & coatings. Cromox ceramic in the 350KeV region subject to blooming. DESY style phosphor coated Al in the 10 MeV regions both the injection line & ER dump extremely linear!. 2 insertable neutral density filters (OD1 & OD2) available for attenuation 10 to 1000. Thin Al flags elsewhere, 1 to 10 microns thick. Forward and backward OTR used. Two locations Silicon wafers for mirror finish. Cohu series 1100 CCD cameras used, 0.05 Lux sensitivity. Bare board cameras mounted in home built enclosure, $100 CCD elements are replaced 3 months to 2 years when radiation damaged. Red LEDs are used for illumination, band pass filters used to limit OTR flux (562nm;10 & 80 nm width) without attenuating the fiducial visualization.. The problem is that the OTR is too bright & ghost pulses contaminate spot size measurements. Linux based Frame grabber, Scion model LG3-64

Examples of Viewer Flags DESY coating under black light 1.5 micron Al foil Cromox ceramic 1 mm reference marks 1 dia. Used @ 350keV DESY Phosphor coating Si wafer fixed for spectrometer 5 micron Al 2 dia. + 5, 10mm reference

Beam Position Monitors. System requires low dynamic range since machine operates between 60 & 135 pc of charge per bunch. As micropulse frequency changes from 4MHz to 75 MHz current is; 0.3mA < I < 10mA. Resolution requirement is + 150 microns in linac, and 50 microns in the wiggler. Hand-me-down electronics from CEBAF still in use, new electronics under development. Shorted stripline BPMs used in areas with round beam tubes. Each electrode subtends 70 degrees. Injector before cryounit has 1.5 diameter (Qty. 1). 10 MeV injector, after cryounit, has 2 diameter (Qty. 3). Linac & back leg has 3 diameter (Qty. 26). Buttons used in rectangular chambers. Arrays of 4 and 8 buttons used in wide chambers. Only 4 of 8 readout with existing electronics 1.5 cm SLAC type button Array of 8 buttons used in wide chamber

Multi-pass BPMs in the LINAC (under development) 1 st Pass Pulse <B> 2 nd Pass Pulse <A > Long term goal is to separate pulses at higher Micropulse Repetition Rate Frequencies. Micropulse Repetition Rate Frequency (9.425 MHz)

1.16 MHz Multi-pass Solution

Synchrotron Light Monitors SLM ports are installed even in unlikely locations Large dipoles were built with telescopes to bring out light THz chicane has a mirror in vacuum to peek into magnet All locations have insertable neutral density (ND) filters to attenuate signal, SLM bright even at 88MeV pulsed beam OD1 (10x) and OD2 (100x) filters extend dynamic range of cameras 3 orders of magnitude SLM port 5F02 with CCD camera and attenuators THz debuncher SLM port

SLM port on THz De-buncher Lasing at 2.8 microns, white spot is SL and yellow/green is the 5 th harmonic

Beam Loss Monitors. Crucial to setting up machine and. 931B PMTs used with programmable HVPS. All 48 analog signal available through the AMS. Trip levels are set to 1 micro amp CW loss 48 channels shown, 4 x 12 channel VME BLM boards shown with AMS and FSD connections on front and tube and high voltage on rear, also shown are the connections to the MPS system Left is a typical beam viewer with BLM mounted in background, note air core correctors mounted on top of BPMs

Bunch Length Measurement by Streak Camera We have established a bunch characterization system with a femtosecond Streak Camera (Shukui Zhang) Bunch length and timing jitter were observed at 2F06 region before ARC1 magnet HAMAMATSU Synchroscan FESCA (C-6860) More OTS will be available for further beam characterization (Tomography ) OTS for Streak Camera 2nd floor L2 3000 Temp Res 500fs 2480 M1=1.2 M1=0.06 Intensity(A.U.) 950 850 750 650 550 450 350 Bunch length -2F06 F1 520 200 F2 M1 beam tube Enclosure 3330 vault ceiling 3015.8 250 150 1 11 21 30 40 50 Time (ps) M2(pico) 870 L1 260 Bunch length measurements for e-beam energy 88Mev/CW 9MHz 200 M3(pico) 200 1st floor

Happek Bunch Length Monitor Installation Happek used to set injector phase, then bunch is optimized using OTR signal from beam viewer Movable mirror to direct signal to interferometer or CCD camera Broad band lens (Shiny Bald Guy) used to collimate the THz signal to Golay cell detector in Martin-Puplett interferometer Interferometer shown with cover removed

Phase Transfer Measurements Drive laser phase is varied and the arrival time is measured at cavities at various points in the accelerator ref. G. Krafft WG4 talk

Emittance Measurements New slit system has been designed with independent horizontal and vertical slits for ease of alignment Slit width is 127 microns, cut by wire EDM This system will be recommissioned over the next weeks An automated quad scan technique being developed by Noboyuki Nishimori (below) Old Multislit w/o horizontal slits Quad strength vs. spot size plot New slits, wire EDM cut

Beam Profile Measurements with WesCam Frame Grabber SLM2F08 MEDM Controls Screen Uses. Injector phasing. Beam spot sizes for Emittance Measurements. Recirculator setup based on beam size and position. Determining the energy distribution of the bunch. Determining the energy spread Next step, automate Linac phasing using beam positioning

Organization of WesCam System Specifications. Scion Corp LG3-64 PCI capture card. 640x480 Resolution. 64 Mb Frame buffer. Stores 128 Frames. External triggering. Cohu 1100 Series camera. Linux Workstation

Analog Monitoring and Video Distribution. 256 X 32 full cross point switch capability for both AMS and Video. AMS output drives Tek scopes with video output that is routed to the Video system. Video system has 32 outputs that drive ~ 100 monitors including streaming 8 channels to the Web. The only difference between the systems is a gain of 5 pre/post amplifier; + 2volts for video, + 10 volts for AMS System INPUT and OUTPUT signal are shown overlaid, 2V P-P, left 1 MHz, right 10 MHz 32 X 32 Cross point chassis Front view of 256 X 32 Configuration Rear view showing cables

Conclusions (What s not done yet or not right!). Better injector diagnostics are needed for understanding source of drifting injector phases. More work to understand halo from gun/light box/cryo-unit. Multi-pass linac BPM electronics need to be completed. A longitudinal diagnostic would be helpful for injector characterization. THz spectrometer makes a good non-intercepting bunch length monitor. Full integrated Machine Protection System with defined Beam & Machine Modes has made commissioning less painful. The AMS & Video System was essential for commissioning and daily operation