LED control gear Compact fixed output

Similar documents
LED Driver Compact fixed output

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

LED Driver Constant voltage

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Emergency lighting units EM powerled

LED Driver Compact dimming

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Emergency lighting units EM powerled

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Linear / area dimming

LED Driver Compact dimming

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

HID control gear Electronic. PCIS, PCS outdoor FOX B011 PCI outdoor. Ordering data. Circuit power1. tc/ta for 60,000 h For luminaires with 1 lamp

LED Driver Linear / area dimming. Driver LCAI 38/75W TW lp Tunable White

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

OT 100/ /700 P5

OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM B011 PCI outdoor

LED MODULES READYLINE DL

OPTOTRONIC Intelligent

PHASED OUT. HID control gear Electronic. PCIS, PCI, PCS outdoor DIM chronostep PCI outdoor

HID control gear Electronic

Technical Information

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

DALI TOUCHPANEL BASIC TW. Operating and control unit

Indoor Linear 80W Driver SI-C215280N2KR

OPTOTRONIC FIT. Product family datasheet. Linear / Area Constant Current Non dimmable. Areas of application. Product benefits.

Operating instructions

Secto Design Oy Kauppalantie Kauniainen Finland tel fax

PHASED OUT. Emergency lighting units EM INVERTER. EM MINI BASIC, V 50/60 Hz BASIC version

Emergency lighting units EM INVERTER

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Catalogue Ignitors and power switches for HID

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Figure 1: Device components

Ordering data. Type Inputs Outputs Dimming switch Motion sensor DSI signal2 Digital control line DSI Control output per physical output (devices)

Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

AS09..S 3-pole Contactors - Spring Terminals

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

Kuhnke Technical Data. Contact Details

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

02/11/2015

Series CT7N Bimetallic Overload Relays

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

architecture mounting Features Product lighting

Product Data Sheet 8506 VW-691

Type: DILM25 10(24V50HZ) Article No.:

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

Linear flow controls VFC Linear flow controls with actuator IFC

ABB i-bus EIB Universal dimmer 6155 EB for Installation

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TOSHIBA Industrial Magnetron E3328

Linear flow control with actuator IFC

PRODUCT DATASHEET QTi DALI-T/E 2X18 42 DIM

15 Series - Dimmer

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Product Data Sheet 4656 ZW

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

Type: DILM12 10(24VDC) Article No.:

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Gamma instabus. Technical product information

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

ODW-621. RS-232 Point-to-point applications

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

Benefits. Applications

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

luxcontrol lighting control system DALI actuator DALI PCD one4all G2 Leading-edge/trailing-edge phase dimmer

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

GR circuit breaker - hydraulic magnetic, Datasheet

Transcription:

Driver LC 40W 900mA fixc SR SNC ESSENCE series Product description Independent fixed output LED Driver Constant current LED Driver Output current 900 ma Max. output power 39 W Nominal life-time up to 50,000 h For luminaires of protection class I and protection class II For luminaires with M and MM as per EN 60598, VDE 0710 and VDE 0711 Temperature protection as per EN 61347-2-13 C5e 5-year guarantee Properties Casing: polycarbonat, white Type of protection IP20 Functions Overtemperature protection Overload protection Short-circuit protection No-load protection È Standards, page 3 Wiring diagrams and installation examples, page 4 www.tridonic.com 1

Driver LC 40W 900mA fixc SR SNC ESSENCE series Technical data Rated supply 220 240 V AC range 198 264 V Input current (at 230 V, 50 Hz, full load) 0.2 A Mains frequency 50 / 60 Hz Typ. power consumption (at 230 V, 50 Hz, full load) 43.5 W Max. input power 46 W Output power range 27 39 W THD (at 230 V, 50 Hz, full load) < 20 % Output current tolerance 3 ± 7.5 % Typ. current ripple (at 230 V, 50 Hz, full load) ± 30 % Turn on time (at 230 V, 50 Hz, full load) 0.5 s Turn off time (at 230 V, 50 Hz, full load) 0.5 s Hold on time at power failure (output) 0 s Ambient temperature ta -20... +50 C Ambient temperature ta (at life-time 50,000 h) 40 C Max. casing temperature tc 90 C Storage temperature ts -40... +80 C Dimensions L x W x H 130 x 68 x 31 mm 34 ø4,5 11 Ordering data Type 130 123 tc 5 Article number 31 ø4,5 13,7 25,3 68 carton low volume Ø 75 high volume Weight per pc. LC 40W 900mA fixc SR SNC 87500551 30 pc(s). 390 pc(s). 1,950 pc(s). 0.152 kg Specific technical data Type Output current 3 at full load 1 Efficiency at full load 1 at min. load 1 Efficiency at min. load 1 Min. forward Max. forward Max. output Max. output peak Max. output peak current at full load 2 current at min. load 2 LC 40W 900mA fixc SR SNC 900 ma 0.96 91 % 0.93C 90 % 30 V 43 V 54 V 1,260 ma 1,440 ma 1 Test result at 230 V, 50 Hz. 2 The trend between min. and full load is linear. 3 Output current is mean value. www.tridonic.com 2

Standards EN 55015 EN 60598-1 EN 61000-3-2 EN 61000-3-3 EN 61347-1 EN 61347-2-13 EN 61547 Overload protection If the output range is exceeded the LED Driver will protect itself and LED may flicker. After elimination of the overload, the nominal operation is restored automatically. Overtemperature protection The LED Driver is protected against temporary thermal overheating. If the temperature limit is exceeded, the output current is reduced to limit tc at a certain level. The temperature protection is activated typically at 10 C above tc max. Short-circuit behaviour In case of a short circuit on the secondary side (LED) the LED Driver switches into hic-cup mode. After elimination of the short-circuit fault the LED Driver will recover automatically. No-load operation The LED Driver works in burst working mode to provide a constant output regulation which allows the application to be able to work safely when LED string opens due to a failure. Installation instructions The LED module and all contact points within the wiring must be sufficiently insulated against 3 kv surge. Air and creepage distance must be maintained. Replace LED module 1. Mains off 2. Remove LED module 3. Wait for 10 seconds 4. Connect LED module again Fixing conditions Dry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambient temperature (ta) stated on the device. Minimum distances stated below are recommendations and depend on the actual luminaire. Is not suitable for fixing in corner. Leuchte Luminaire >100 mm Storage conditions Humidity: 5 % up to max. 85 % not condensed (max. 56 days/year at 85 %) Storage temperature: -40 C up to max. +80 C >50 mm The devices have to be within the specified temperature range (ta) before they can be operated. >20 mm Hot plug-in or secondary switching of LEDs is not permitted and may cause a very high current to the LEDs. Expected life-time Type ta 40 C 50 C 60 C LC 40W 900mA fixc SR SNC tc 80 C 90 C x Life-time 50,000 h 30,000 h x The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 Imax Time LC 40W 900mA fixc SR SNC 40 55 70 85 35 55 70 85 10 A 100 µs Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in % THD 3. 5. 7. 9. 11. LC 40W 900mA fixc SR SNC 20 10 2 2 2 1 www.tridonic.com 3

Wiring diagram 220 240 V 50/60 Hz L N Wiring type and cross section The wiring can be in stranded wires with ferrules or solid. For perfect function of the cage clamp terminals the strip length should be 4 5 mm for the input terminal. The max. torque at the clamping screw (M3) is 0.2 Nm. Use one wire for each terminal connector only. Use each strain relief channel for one cable only. + + LED LED Umodule Uconverter LC... SR SNC ô SEC PRI Input / Output terminal max. ø = 10,0 mm min. ø = 2,2 mm 0,5 2,5 4 5 Glow wire test according to EN 60598-1 with increased temperature of 850 C passed. Isolation and electric strength testing of luminaires Electronic devices can be damaged by high. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. Wiring instructions All connections must be kept as short as possible to ensure good EMI behaviour Mains leads should be kept apart from LED Driver and other leads (ideally 5 10 cm distance) The maximum length of output wires is 2 m. Secondary switching is not permitted. Incorrect wiring can damage LED modules. The wiring must be protected against short circuits to earth (sharp edged metals parts, metal cable clips, louver, etc.) As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. www.tridonic.com 4

Diagrams LC 40W 900mA fixc SR SNC Efficiency vs load vs load Efficiency [%] 100 95 90 85 80 1,00 0,98 0,96 0,94 0,92 0,90 0,88 0,86 0,84 0,82 0,80 50 Input power vs load 210 Input current vs load Input power [W] 45 40 35 30 Input current [ma] 200 190 180 170 160 150 25 140 THD vs load THD 20 18 16 14 12 10 8 6 4 2 0 www.tridonic.com 5