MANLEY LABORATORIES, INC. OWNER'S MANUAL MANLEY REFERENCE DIGITAL TO ANALOGUE CONVERTER MANLEY LABORATORIES, INC MAGNOLIA AVE. CHINO, CA.

Similar documents
MANLEY LABORATORIES, INC.

MANLEY LABORATORIES, INC.

MANLEY LABORATORIES, INC.

VK-P10SE WARRANTY REGISTRATION FORM

MANLEY LABORATORIES, INC.

LavryBlack Series Model DA10 Digital to Analog Converter

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MF80. MF80 Owner s Manual 1

The Phono Box SUMIKO Fifth Street Berkeley, CA sumikoaudio.com

DA8-T DA8-T MANUAL

O W N E R ' S M A N U A L. D/AC-1100 Digital/Analog Converter

Issue date : 9/11/00. Rogue Audio Tempest Vacuum Tube Integrated Amplifier. Owners Manual. Vacuum Tube Amplifiers

Recording to Tape (Analogue or Digital)...10

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

Model 22.1 HDCD D/A Converter Instructions

Sphinx II. Owner s Manual. Tube Hybrid Integrated Power Amplifier. Rogue Audio, Inc. 3 Marian Lane Brodheadsville, PA Issue date: 08/01/16

PAD-2 2 Channel A-D Converter Mk2 Rev. 3 Sept. 24, 2017

Please take a few minutes to read this manual so that you will better understand the featues and capabilities of your MV52. MV52 Owner s Manual 1

LavryBlack Series Model AD10 Analog to Digital Converter

Pre1. Balanced Control Preamplifier. User's Guide and Operating Information

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

music hall pa2.2 INSTRUCTION MANUAL music hall

bel canto SEP2 Single Ended Triode Tube Preamplifier User's Guide and Operating Information

INSTRUCTION MANUAL PELLAR PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

Owner s Manual SUONO. 25W Class A Single Ended Power Amplifier. manual v1.2

OWNER'S MANUAL MYCRO SUB

HA75-DAC USB Digital Audio Converter & Headphone Amp

Utility Amplifier GA6A Model

INSTRUCTION MANUAL PELLERE PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

M2 RIAA Owner s Information

Owner s Manual PRE1. v1.2. Triode Class A Line Preamplifier

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

OWNER MANUAL PV9 VACUUM TUBE PREAMPLIFIER. conrad-johnson design

INSTRUCTION MANUAL PULSUS PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

Kramer Electronics, Ltd. USER MANUAL. Models: 6410N, Digital to Analog Audio Converter 6420N, Analog to Digital Audio Converter

RoHS. Atma-Sphere Music Preamplifier. model P-2 OWNER'S MANUAL. Please study this document carefully before using equipment

SATRI AMPLIFIER AMP-51R. Owner s Manual

Thank you for purchasing the Suhr Buffer. Please take the time to read this user guide to get the most out of your buffer and it s applications.

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Calaf integrated stereo amplifier

Low Noise Solid State Phono Preamplifier User's Guide and Operating Information

A y r e. K-1x Preamplifier. Owner s Manual

Kramer Electronics, Ltd. USER MANUAL. Model: Digital Audio Transcoder

Reference 150 LINEAR

BP2-MM MM Phono Preamplifier Owner s Manual

ModWright Instruments, Inc. PH 150 Tube Phono Stage Owner s Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

Contents Introduction Safety Cleaning Connections Cartridge gain and loading Technical specification Fig.1 PS.30R/ PS.30RDT rear panel Fig.

Owner's Manual. Model PH6 PHONO PREAMPLIFIER.

INSTRUCTION MANUAL. Extended 5-Year Warranty

Kramer Electronics, Ltd.

CLASSÉ AUDIO CP-60 REMOTE CONTROL BALANCED PREAMPLIFIER CP-60 OWNER'S MANUAL

ATMA-SPHERE MUSIC PREAMPLIFIER. model MP-3 Mk. 3.2 OWNER'S MANUAL

MX-206 Stereo Microphone Mixer. Operating Manual

Owner s Manual MIGHTY. Class A Single Ended Power Amplifier

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

LAMM INDUSTRIES, INC.

ENGLISH Antenna Distributor

Owner s Manual. Model PH8 Phono Preamplifier

This Level 3 amplifier features Audio Note Silver wire and Audio Note signal capacitors. UNPACKING AND INSTALLATION

DAC3.1x/II Balanced DIGITAL TO ANALOGUE CONVERTER OWNER S INFORMATION

Instruction Manual By Digital & Analog

Operating Manual. Mark Levinson Nº25 Dual Monaural Phono Preamplifier. Madrigal Audio Laboratories, Inc. 1

Distribution Unit. User Guide

USER MANUAL. Kramer Electronics, Ltd. Models:

Hegel HD20 High End D/A Converter

PL-2 Analog Peak Limiter Manual

Kramer Electronics, Ltd. USER MANUAL. Model: Power Amplifier

Table of Contents. Introduction...1

PRO VLA PROFESSIONAL TWO CHANNEL VACTROL/TUBE LEVELING AMPLIFIER

Reference DSD1.1 d/a Converter 32Bit/768KHz DSD256 d/a Converter

COMPACT DIGITAL AUDIO. Unpacking and Placement

Universal Control Center User's Guide

D.W. FEARN. VT-4 Vacuum Tube LC Equalizer. Operating Instructions

Kramer Electronics, Ltd. USER MANUAL. Model: 810B. Black Burst / Audio Generator

Kramer Electronics, Ltd. USER MANUAL. Models: OC-1N, Video Isolator OC-2, Dual Channel Video Isolator OC-4, Quad Channel Video Isolator

M3 Phono PRE AMPLIFIER OWNER S INFORMATION

12 Channel Media Splitter MS12 Mk2 User manual

TABLE OF CONTENTS. 1) Introduction 2. 2) Unpacking the Ares 2. 3) Installing the Ares in your system 3. 4) Setting the Operational Parameters 4

CLASSIC SERIES POWERED SUBWOOFERS

Orfeo 30 Single Ended 845 Triode Monobloc Audio Power Amplifier User's Guide and Operating Information

SETi 40 Integrated Amplifier Single Ended 845 Triode User's Guide and Operating Information

USB Phono Plus. Project Series USER S MANUAL. Audiophile Computer Interface

BP2-MM/MC Phono Preamplifier Owner s Manual

Kramer Electronics, Ltd. USER MANUAL. Model: 482xl. Bi-directional Audio Transcoder

HP6E Operating Manual. August 2012

Introduction Front Panel Functions Rear Panel Functions Precautions Placement & Ventilation... 5

MDA-2-HV. 1x2 Moblie Distribution Amplifier. Instruction Manual

VACUUM TUBE COMPRESSOR

Valve Amplification Company

Hegel HD10 High End D/A Converter

FREYA. balanced remote control preamp. beauty, fertility, gold, seiðr, war, and death.

M8 Phono Balanced CD Input

PRO MPA II. ART PRO MPA II Microphone Preamplifier USER S GUIDE

We extend our regards from Bochum and wish you much musical satisfaction from your new Einstein The Light in the Dark.

INSTRUCTION MANUAL PULSARE PHONO PRE-AMPLIFIER. Extended 5-Year Warranty

Kramer Electronics, Ltd.

blink USER GUIDE Bluetooth capable Reclocker Wyred 4 Sound. All rights reserved. v1.0

Owners Manual. Microphone Preamplifier and A/D Converter. Manual Rev E

Transcription:

MANLEY LABORATORIES, INC. OWNER'S MANUAL MANLEY REFERENCE DIGITAL TO ANALOGUE CONVERTER MANLEY LABORATORIES, INC 13880 MAGNOLIA AVE. CHINO, CA. 91710 TEL: (909) 627-4256 FAX: (909) 628-2482

CONTENTS SECTION PAGE INTRODUCTION 3 MAINS CONNECTIONS 4 FIGURE 1 FRONT PANEL 5 FIGURE 2 REAR PANEL 6 INPUT CONNECTIONS 7 WARRANTY 8 WARRANTY REGISTRATION 9

INTRODUCTION THANK YOU!... for choosing the Manley Laboratories REFERENCE 20 BIT DIGITAL TO ANALOGUE CONVERTER. Please read over this manual carefully as it contains information essential to proper operation of this unit. The MANLEY DIGITAL TO ANALOGUE CONVERTER features completely dual-mono analogue sections and power supplies, the heart of which is the only TRUE 20-BIT, 128x oversampling converter unit available today, custom made for us by ULTRAANALOG. By "TRUE 20-BIT" we mean that full 20 bit perfomance IS actually achieved from years of exhaustive research and engineering on the converter chip itself. While some converters claim to be 20 bit, or 18 bit, or 16 bit, seldomly is the 18th, 16th, or 14th bit performance ever reached. The 8x oversamplig rate at which the ULTRAANALOG operates eliminates the need for steep anti-alias filters, and eliminates differential non-linearity and harmonic distortion for low amplitude signals. The AES-21 chip effectively removes incoming jitter from the digital inputs. For maximum fidelity and musical involvement the line amplifier is a low impedance all vacuum tube design. GENERAL NOTES LOCATION & VENTILATION The MANLEY DIGITAL TO ANALOGUE CONVERTER must be installed in a stable location with ample ventilation. It is recommended, if this unit is rack mounted, that you allow enough clearance on the top and bottom of the preamp such that a constant flow of air can flow through the ventilation slots. WATER & MOISTURE As with any electrical equipment, this unit should not be used near water or moisture. If liquid enters the unit, it must be immediately returned to your dealer for servicing. SERVICING The user should not attempt to service this unit beyond that described in the owner's manual. Refer all servicing to Manley Laboratories. WARNING! TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT OPEN THE CABINET REFER SERVICING TO QUALIFIED PERSONEL!

MAINS CONNECTIONS Your unit has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not have a plug fitted the coloured wires should be connected to the appropriate plug terminals in accordance with the following code. GREEN/YELLOW EARTH terminal BLUE NEUTRAL terminal BROWN LIVE terminal As the colours of the wires in the mains lead may not correspond with the coloured marking identifying the terminals in your plug proceed as follows; The wire which is coloured GREEN/YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN and YELLOW. The wire which is coloured BLUE must be connected to the terminal in the plug which is marked by the letter N or coloured BLACK. The wire which is coloured BROWN must be connected to the terminal in the plug which is marked by the letter L or coloured RED. DO NOT CONNECT/SWITCH ON THE MAINS SUPPLY UNTIL ALL OTHER CONNECTIONS HAVE BEEN MADE.

FRONT PANEL CONTROLS A B C E D F G H I J A DIGITAL INPUT SELECT: Selects any of the 4 digital inputs. Positions 1, 2 and 3 correspond to the RCA phono style SPDIF and the XLR AES / EBU inputs. Position 4 corresponds to the A.T.&T. Optical input. When the switch is changed the output mutes until "VALID DATA" is "LOCKED"onto by the AES 21 jitter reduction chip. B C D E F 32, 44.1, 48: 3 red LEDs that indicatethe sample rate of the incoming data. CD's are always 44.1 while the sample rate of DAT's may be any of the three. VALID DATA LED: Lit when the unit has a readable input that can be converted to audio. PLL LOCK LED: Lit when the Phase Lock Loop of the jitter removal system has synchronized to the digital input data. When input is lost as when changing the "INPUT SELECT" there will be a one second period before the AES 21 resynchronizes and the LED lights. If on the selected input the sample rate is changed or theled seems to be "hunting" or flickering change the "INPUT SELECT" and back to restart the AES 21 chip into resync mode. PHASE: Switches the polarity of both channels. Often a subtle change depending on the music and symetry of the waveforms. The typical recording process occasionally accidently inverts the polarity and this little switch restores it. VOLUME: This is a precision dual stepped attenuator. Because some users prefer to feed the outputs of this unit directly to their power amps this VOLUME becomes their main volume control. Other users with a preamp can use this control to match the output of the D to A to thier analogue sources avoiding level jumps.

MUTE ERROR LED. Red LED indicates when the Output Muting Circuit is activated. The output is reduced by over 60 db : When there is not "VALID DATA" When the PLL is not yet "LOCKED" For 30 seconds during "WARM UP" after first powering on the converter. Immediately when the unit is "turned off". For 1 second between "INPUT SELECTS" DEEMPHASIS LED: POWER LED: POWER SWITCH: Lit only if the digital data has been pre-empasized. There are very few CD's with Pre-Empasis and it is unlikely that the deemphasis circuit (equalizer) will be switched in automatically. Lit when the Converter is plugged into the wall and the power switch is on. If not lit check that the power cable is correctly plugged in and that the fuse is good. In one position the Converter will be dark and will filter all data from becoming audio at the outputs. In the up position LEDs will light up and the Converter will filter the data for 30 seconds before it lets music thru. Some users prefer only to use the up position so that the unit is always well warmed up and ready for serious listening. Others prefer the longer tube and capacitor life and lower utility bills of using both positions. GOLD PLATED DIGITAL BOARD LEFT 6414 RIGHT 6414 12AU7 12AU7

REAR PANEL A B C D E F G H I A VOLTAGE CHANGEOVER SWITCH: Set for the correct mains voltage for your area by rotating the centre section with a flat screwdriver. B IEC MAINS SOCKET: Standard IEC mains socket (120/240 VAC) C FUSE HOLDERS: Replace with 1A SLO-BLO fuse only. D UNBALANCED LINE OUTPUTS. From tube line amp. Variable GAIN. E BALANCED LINE OUTPUTS: PIN 2 HOT, PIN 3 LO, PIN 1 GROUND 6 db more signal than at UNBALANCED OUTPUTS. F AT&T AT OPTICAL INPUT. NOTE THERE IS A GREY PROTECTIVE COVER THAT MUST BE PULLED OFF BEFORE USING. THE CONNECTOR IS LOCKED WITH A QUARTER TURN CLOCKWISE. This is GLASS FIBER as opposed to plastic TOSLINK. Our opinion is that this is the best sounding input here but that CD transports with this type of output are too rare. Some CD transports and players can be upgraded (modded) for this. G AES / EBU DIGITAL INPUTS. 110 Ω balanced and transformer isolated. Use special digital interconnects with gold plated contacts rather than "mic" cables. H SPDIF / AES SELECT: This LOCKING switch will optimise either AES or SPDIF digital formats. To change the setting of this switch, PULL OUT the toggle before switching. Do not use both an AES and SPDIF line into one input. I SPDIF INPUTS: Three individual 75Ω transformer isolated inputs. Do not use audio interconnects. Use specialized high quality digital data cables to get the best data integrity. Gold plated connectors will mate best with these gold plated jacks.

2 CUSTOM 20 BIT ULTRA-ANALOG DIGITAL TO ANALOG CONVERTERS 1 ULTRA-ANALOG AES 21 JITTER REMOVAL CHIP VACUUM TUBE HIGH CURRENT LO-IMPEDANCE MANLEY LINE DRIVERS 4 TUBES ( 4 DIRECT COUPLED TRIODES PER CHANNEL) 15 SEPARATE POWER SUPPLY REGULATORS: 6 @ +5V (LT) 3 @ +12 V 3 @ +15 V (LT) 3 @ - 15 V (LT) PRECISION DUAL STEPPED ATTENUATOR 4 WAY INPUT SELECTOR SWITCH PHASE / POLARITY SWITCH 3 SPDIF INPUTS 3 AES / EBU INPUTS AT&T OPTICAL INPUT BOTH UNBALANCED AND BALANCED ANALOGUE OUTPUTS LED INDICATORS FOR VALID DATA, PLL LOCK AND AUTOMATIC MUTE PRECISION MILLED BILLET 19' X 5.25 X 11.5 CHASSIS NEW ANTI-ALIAS FILTER OPTIMIZED FOR CRITICAL LISTENERS AND SUPERB MUSIC REPRODUCTION SYSTEMS PRECISION AUDIOPHILE COMPONENTS USED THROUGHOUT: GOLD PLATED DIGITAL PC BOARD MIT OUTPUT CAPS, CUSTOM FILM ON FOIL CAPS LO Z PANASONIC ELECTROLYTICS IN POWER SUPPLIES LINEAR TECHNOLOGY REGULATORS OFC SILVER PLATED TEFLON INSULATED WIRE GOLD PLATED CONNECTORS FOR LOW OXIDATION AND LONG LIFE METAL FILM 1% RESISTORS

WARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of first purchase. Proper registration is made by filling out and returning to the factory the warranty card attached to this general warranty statement, along with a copy of the original sales receipt as proof of the original date of purchase. Only 1 card is issued with each unit, and the serial number is already recorded on it. If the warranty registration card has already been removed then this is not a new unit, and is therefore not warranted by the factory. If you believe this to be a new unit then please contact the factory with the details of purchase. This warranty is provided by the dealer where the unit was purchased, and by Manley Laboratories, Inc. Under the terms of the warranty defective parts will be repaired or replaced without charge, excepting the cost of tubes. No warranty is offered on tubes, unless: 1. a Manley Laboratories preamplifier is used with a Manley Laboratories amplifier, and 2. the warranty registration card is filled out. In such a case a 6 month warranty on tubes is available with the correct recording of the serial number of the preamplifier on your warranty registration card. If a Manley Laboratories product fails to meet the above warranty, then the purchaser's sole remedy shall be to return the product to Manley Laboratories, where the defect will be repaired without charge for parts and labour. The product will then be returned via prepaid, insured freight, method and carrier to be determined solely by Manley Laboratories. All returns to the factory must be in the original packing, (new packing will be supplied for no charge if needed), accompanied by a written description of the defect, and must be shipped to Manley Laboratories via insured freight at the customer's own expense. Charges for unauthorized service and transportation costs are not reimbursable under this warranty, and all warrantees, express or implied, become null and void where the product has been damaged by misuse, accident, neglect, modification, tampering or unauthorized alteration by anyone other than Manley Laboratories. The warrantor assumes no liability for property damage or any other incidental or consequental damage whatsoever which may result from failure of this product. Any and all warrantees of merchantability and fitness implied by law are limited to the duration of the expressed warranty. All warrantees apply only to Manley Laboratories products purchased and used in the USA. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damges, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to validate your warranty and registration. Thank you again for choosing Manley Laboratories. MODEL SERIALNo. PURCHASE DATE SUPPLIER --------------------------------------------------------------------------------------------- PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL SERIAL No. PURCHASE DATE SUPPLIER NAME OF OWNER ADDRESS CITY, STATE, ZIP TELEPHONE NUMBER Serial #'s of Associated Manley Laboratories Equipment