PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

Similar documents
PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION PEM1368ENG ENGLISH

INSTALLATION INSTRUCTION PEM1423ENG ENGLISH

Instructions. Cable with Armor F CAUTION. October Rev A

LEGEND POWER SYSTEMS

Quick Term III. 3M Cold Shrink 3 Core Indoor Termination. 3.3 kv mm 2

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

Cold Shrink Straight Joint

3M Cold Shrink Splice Kit QS-III 5416A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink Splice Kit QS-III 5515A

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Cold Shrink Foldback Splice Jacket Kit

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-2-4/0

3M Cold Shrink QS-III Splice Kit 5467A(S)-WF

3M Sensored Termination (15 kv) QX-T15I-vi1-E

L1-CHE-SPE-299 TECHNIQUES & MATERIALS FOR THE JOINTING & REPAIR OF RAILWAY SIGNALLING MULTI CORE AND POWER SUPPLY CABLE

STRAIGHT TWO WAY JOINT3/C, PAPER INSULATED, SHIELDED, LEAD COVERED CABLE. Revised: October 10, 2008 Revised By: SGL Approved By: RHS SPLICES

ENERGY /// TRICKS OF THE TRADE TRICKS OF THE TRADE

3M Cold Shrink QS4 Integrated Splice Kit QS4-15SP-2-4/0

3 SLiC Aerial Closure with Rubber End Seal

HSK Mine and Portable Cable Splice


F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

3M Better Buried Compound Compression Closure System

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

3M Better Buried Closures

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 CABLES SPLICES

PRODUCT CATALOGUE 2016

Cold Shrink Silicone Rubber Termination QT-II

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Cable installation guidelines

VITALink Taped Splice Straight Through Crimp

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Quick Term II. Cold Shrink Silicone Rubber Termination (With High-K Stress Relief) Instruction Sheet. Quick Term II. Silicone Rubber Termination Kits

3 Cold Shrink Products

Cables for robot applications

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Industrial Loadbreak Elbow

System 500. Non-fire-rated, mineral insulated copper sheathed wiring cable

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

COOPER POWER SERIES. 600 A 15/25 kv class DT625 T-body installation and cable preparation instructions. Deadbreak Apparatus Connectors MN650017EN

FOSC 450 C6 and D6 Closures

3M Cold Shrink Rubber Splicing Kit 5552

Identification - electrical services

Service Call: Fiber Optic Installation and Repair

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

Instrukcja montażu. FLEX LED Neon Instalacja

Coaxial Cable Feedline Choke Kit - 50 Ω

Quick Term II Silicone Rubber Termination Kits for Shielded Cables Instruction Sheet

Student Services & Classroom Addition

Flygt Submersible Motor Cables

INSTALLATION INSTRUCTIONS

Scotch Heavy Duty Vinyl Electrical Tape 22

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

UNSIGNED HARDCOPY NOT CONTROLLED

3M Distribution Box (DDB)

Safe, Accurate, and Repeatable

2178-L/S Series Fiber Optic Splice Case with Gasket

Solutions for Electronic Specialty Markets (ESM)

Aging test: integrated vs. non-integrated splices shield continuity systems.

Installation Instructions

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

Cable solutions for all environments. Scapa Cable Solutions

Flame-retardant cable for

Siam Pacific Electric Wire & Cable Co., Ltd.

UNDERGROUND CONSTRUCTION MANUAL MATERIAL DATA

Power and Control T YPE BY RAVI GANATR November/December IAEI NEWS

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

Instrumentation Cables

Medium Box for Cable Termination

Continuous Flex Data Cable

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

SLiC Fiber Aerial Closure System

FusionLink Central Tube Ribbon Preparation & handling procedure

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

PYROTENAX TERMINATION KITS COMMERCIAL WIRING. For Pyrotenax copper sheathed mineral insulated (MI) wiring cable

2.1 Kit Contents 2.2 Elements needed from the FIST installation kit 2.3 Tools 2.4 Cable preparation table

Gel-sealed in-line fiber optic closure

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

3 Cleaning. 4 Technical data

Road cables. The foundation for a reliable traffic infrastructure.

Draft for Public Comment

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

Optical Distribution Box 300 Installation Guide. Version : R0.0

INSTRUCTION DE SÉCURITÉ SAFETY INSTRUCTION Mandatory as defined in SAPOCO/42 FIRE PREVENTION FOR CABLES, CABLE TRAYS AND CONDUITS

Water blocking tape. Locator ridge HPA-0486

HCS - HES Cabling Systems

Transcription:

INSTALLATION INSTRUCTION PEM1124ENG 2010-05 STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv ENGLISH 4 CORE 3+1 CORE

2/8 PEM1124ENG 2010-05 GENERAL INFORMATION - Check that the kit is suitable for the cable type. - Check the materials listed in the bill of materials for completeness. - Read the installation instructions carefully before starting the installation. - Install carefully and make sure the materials are clean during the installation. - Clean the working place after the installation. GENERAL INSTRUCTIONS FOR HEAT SHRINKING - Please note that in some working places a hot work permit is needed. - Use a propane burner with a flame length of approx. 20-30 cm. Do not use too large or sharp flame. - Move the flame all around the cable on the shrinking direction. Move the flame continuously to avoid overheating. - Make sure that the ventilation is good and there are no flammable materials around. - Clean the cable surfaces before shrinking. - When shrinking, always follow the installation instructions and the relevant sequence to avoid trapped air. - Check that the tube has shrunk evenly around the cable before you continue shrinking. - If the tube turns around at the end of shrinking, straighten the tube by directing the flame inside the tube from the opposite direction. - After shrinking the tubes should be smooth and even following the shape inside. LEGAL NOTICE - The product must be installed only by a competent person with sufficient training in installation practices and with sufficient knowledge of good safety and installation practices in respect of electrical equipment. If local legislation contains provisions in respect of such training or sufficient knowledge in respect of installation of electrical equipment such provisions shall be fulfilled by the said person. - Ensto accepts no liability concerning claims resulting from misuse, incorrect installation or ignored national safety regulations or other national provisions. - WARNING: Failure to follow the installation instructions may result in damage to the product and serious or fatal injury.

PEM1124ENG 2010-05 3/8 Table 1 Termination for plastic cables Kit Range A mm (max) 1 4x35-50 1000 3 4x70-185 1000 4 4x185-300 1000 4-CORE CABLES WITHOUT ARMOURING Cable lug with shear head bolts Heat shrink tube with adhesive Thin wall black (STKO) Cable break-out Thin wall green/yellow (STKO) A X 1. Peel the cable outer sheath (Note max A). Roughen and clean the cable outer sheath for 150 mm length and clean the cores for the whole length. Cut the long black heat shrink tube to 3 equal length pieces (dimension A) and draw them and the green-yellow one over the cable conductors. Shrink the tubes starting from the crutch. Place the breakout as deep into the crutch as possible. Start shrinking it from the middle, continue then to the lower part of breakout and finally shrink the fingers. 2. Peel the insulation for X + 10 mm (according to picture). Brush the Al-conductors with brush or grinding paper and install the cable lugs according to manufacturers instructions. (Use always the tinned extra sleeves in the lug, if the cable fits in the sleeve). 3. Shrink the heat shrink tubes with adhesive, over the cable lugs and cores. The termination is now ready. Let the termination to cool down before applying any mechanical load.

4/8 PEM1124ENG 2010-05 3+1 CABLES (CABLES WITH CONCENTRIC NEUTRAL) Cable lug with shear head bolts Heat shrink tube with adhesive Thin wall black (STKO) Sealing mastic Cable break-out X Thin wall green/yellow (STKO) A 1. Notice! Before cutting the cable, dimension the cutting so that Cu-wires of the concentric conductor are long enough. Remove the cable outer sheath. Roughen and clean the cable outer sheath for 150 mm length, and clean the cores for the whole length. Cut the long heat shrink tubes (black) to 3 equal length pieces (dimension A) and draw them over the cable conductors. Shrink the tubes starting from the crutch. 2. Wrap two layers of sealing mastic onto the cable outer sheath from the crutch to 40 mm over the outer sheath. Bend Cu-wires on the cable outer sheath (sealing mastic). Place the breakout over the mastic. Start shrinking it from the middle, continue then to the lower part of breakout and finally shrink the fingers. Twist Cu-wires of the concentric conductor. Shrink the thin wall heat shrink tube (green / yellow) over them. 3. Peel the insulation for X + 10 mm (according to picture). Brush the Al-conductors with brush or grinding paper and install the cable lugs according to manufacturers instructions. (Use always the tinned extra sleeves in the lug, if the cable fits in the sleeve). 4. Shrink the heat shrink tubes with adhesive, over the cable lugs and the cores according to the picture. The temination is now ready. Let the termination to cool down before applying any mechanical load.

PEM1124ENG 2010-05 5/8 ARMOURED CABLES outer sealing tube A + 30 1. Place the outer tube on the cable. Peel the cable outer sheath for the length of dimension A+30 mm. Roughen the armour for 40 mm with grinding paper or steel brush and clean it. 30 2. Remove the armour up to 30 mm from the outer sheath. Roughen the outer jacket for 150 mm. 40 3. Wrap two layers of sealing mastic 40 mm over the outer sheath according to the picture. Fix the tinned copper braid with constant force spring to the armour so that the tinned part is over the mastic. Tie also the braid against the cable outer sheath with 2-4 rounds of Cu -wire. Protect it with PVC -tape. Constant force spring: Turn first one turn of constant force spring on the copper braid. Fold then the tail of the braid over the constant force spring and finish the tightening of the spring. Tighten the spring by hand and wrap some pvc -tape over it to keep it tight. Sealing mastic 40 4. Wrap two layers of sealing mastic from the crutch to 40 mm over the outer jacket.

6/8 PEM1124ENG 2010-05 outer sealing tube 5. Place the outer sealing tube over the mastic so that it starts from the crutch. Shrink it starting from the middle. X Heat shrink breakout 6. Push the breakout into the crutch as far as possible. Shrink the breakout starting from the middle, continuing to the bottom and finally to the fingers. Remove the insulation of the conductors for the depth of the lugs hole + 10 mm. Heat shrink tube with adhesive Cable lug 7. Brush and clean the bare conductors. Place the cable lugs to conductors. If the conductor size is smaller than the minimum accepted conductor size for lug, use the filler pieces included in the kit inside of the lug (70 mm²). Tigten the cable lugs according to manufacturers instructions. Shrink the short tubes over the lugs. 8. The termination is now ready. Let the termination to cool down before applying any mechanical load.

PEM1124ENG / 2010-05-11 UTILITY NETWORKS ENSTO SEKKO OY P.O.BOX 51 06101 PORVOO, FINLAND TEL. +358 204 76 21 FAX. +358 204 76 2770 UTILITY.NETWORKS@ENSTO.COM WWW.ENSTO.COM