LM10 linear magnetic encoder system

Similar documents
RLC2IC component magnetic encoder with magnetic rings MR050C and MR047B

Linear encoders without bearings incremental System for linear motion feedback

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

ENC - LKE51 - L I B

Installation guide M F RESOLUTE

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Installation guide M C

QUANTiC RKLC40-S incremental linear encoder system

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Magnetic Sensor - Incremental EHP

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Material: Weight: IP Rating: Cable: Connector:

RESOLUTE absolute optical encoder with Panasonic serial communications

DOP (dual output) encoder system

MAGNETIC TAPE. Series MB. incremental scale. Key-Features:

Installation guide M A

Cylindrical Photoelectric Sensor CY-100 SERIES

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Proportional output thumbwheels - sprung to centre

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

ENC-CK58SN-L R-L1

NUMERIK JENA. LIA Series. Exposed Linear Encoder. with Signal Control. Mounting Instructions

Installation guide M A

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Fiber-Optic Sensor Amplifiers E3S-X3, E3X-NL and E3X-NM Discontinued March 2012; Revised Replacements

Type SCH94FO. Type SCH94FO. Description

Incremental Hollow Shaft Encoder

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Contactless Encoder Incremental: ppr RI360P0-QR24M0- INCRX2-H1181

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

Online data sheet SGS4-S108P3PS2W03 SLG SWITCHING AUTOMATION LIGHT GRIDS

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Product Information. LIC 4113 LIC 4193 Absolute Exposed Linear Encoders

E8Y. Micropressure Sensor with Easy-to-Read Digital Display. Differential Pressure Sensor. Ordering Information. Sensors

ENC-MC58SN-L R-L1

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Displacement Measuring System for Cylinder Series OSP-P

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

W100L: Laser Sensor in Mini- Format

Incremental Hollow Shaft Encoder

Clamps, mounting plate EN :1993, 100 g/11 ms, 100 shocks EN :1995, 20 g 10 Hz-2 khz, 10 cycles

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

Absolute Encoders Multiturn

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

PROPORTIONAL VALVES Sentronic plus

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

20 mm Beam Pitch General Purpose Area Sensor. Distance between parts shelf and sensor can be shortened (Enables miniaturization of equipment)

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

Installation guide M C. RESOLUTE RESA and REXA absolute angle encoders

case 5 temperature sensor cosine sensor sine sensor ground + 5V phase 2- phase 2+ phase 1- phase 1+

Assembly. Front view. LEDs. Parametrization interface. Power Bus

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

PT9420 Cable Actuated Sensor Industrial ma 0..20mA

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

SPACESCAN SERIES SS 02

Contactless Encoder IO-Link Ri360P0-QR24M0-IOLX2-H1141

02/11/2015

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

02/11/2015

Three Axis Digital Readout System

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

Rexroth GDS/GDM1.1 Digital Singleturn/Multiturn Encoder

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

Data Pattern Generator

SECTION 4 TABLE OF CONTENTS

Interface Connectors for Miniature, Portable Terminal Devices

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TONiC T100x RGSZ linear encoder system

Absolute Rotary Encoder E6CP

TONiC T103x RTLC-S linear encoder system

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Product Information. RIQ 425 Absolute Rotary Encoder with Inductive Scanning Principle for High Bearing Loads

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Documentation. Magnetic Encoder System (MES) Version: Date:

WIRING. Connection connector. NPN output type Standard type. Main circuit. High-function type. Main circuit. PNP output type.

Incremental angle encoders based on the inductive AMOSIN Measuring Principle

Transcription:

RLS merilna tehnika d.o.o. Cesta II. grupe odredov 5 SI-161 Ljubljana - Dobrunje Slovenia T +86 1 57100 F +86 1 5719 E mail@rls.si www.rls.si Installation guide Issue 4, 14 th January 009 LM10 linear magnetic encoder system EMC compliance The LM10 encoder system conforms to the relevant harmonised European standards for electromagnetic compatibility as detailed below. BS EN 616 Patents Features of RLS s encoder systems and similar products are the subjects of the following patents and patent applications: GB 07097.9 EP 0514081 EP 08845 US 5,41,17 US 5,06,685 JP,0,16 JP 8748 Further information For further information relating to the installation of LM10 encoder system, see also the LM10 Data sheet (part no. LM10D01) and the Scale installation guide (part no. LM10D0). These can be downloaded from our website www.rls.si/lm10 and are also available from your local representative. Disclaimer Considerable effort has been made to ensure that the contents of this document are free from inaccuracies and omissions. However, RLS merilna tehnika d.o.o. makes no warranties with respect to the contents of this document and specifically disclaims any implied warranties. RLS merilna tehnika d.o.o. reserves the right to make changes to this document and to the product described herein without obligation to notify any person of such changes. Storage and handling continued Storage and handling > 60 mm WRNING: The MS10 magnetic scale should not be exposed to magnetic flux densities higher than 50 mt on its surface. Magnetic fields higher than 50 mt can damage the scale. Storage -40 C to +85 C Operating -10 C to +80 C (cable under non-dynamic conditions: -0 C to +85 C) Up to 100 % RH System description The LM10 encoder system consists of an LM10 readhead on MS10 magnetic scale offering a range of industry standard digital and analogue output options. mark The repeatable bi-directional reference signal can be provided in ways. 1. Stick-on reference mark. The LM10 readhead should be ordered with the reference mark option. fter installation of the scale a reference mark sticker can be applied to the scale at the required position using the reference mark applicator tool. Ensure that the reference sticker is oriented to the corresponding side of the readhead that has the reference mark detector installed.. Selected at point of order. The LM10 readhead should be ordered with the reference mark option. If required, the cover foil can be installed over the cut reference mark.. Every mm. The LM10 readhead should be ordered with this specific mode activated only. LED indicator The LM10 set-up LED provides visual feedback of signal strength, error condition, for set-up and diagnostic use. Green indicates good signal strength/set-up Red indicates poor signal strength adjustment required Motor oil Brake fluid Kerosene Turpentine ntifreeze Heptane Benzene Toluene lcohol Ketone H SO 4 HCl NOTE: IB output type LED flashes red.

Installation guide Tape length = measuring length + 5 mm Measuring length Positive counting Min. distance of Ri from left edge 0 mm 10 mm Position of reference mark Machined reference mark (Ri) Min. distance of Ri from right edge Scale installation Readhead installation The LM10SC00 scale guide is mounted in place of any RLS LM10 readhead and uses motion of the axis to apply MS10 tape scale parallel to the guideway a one man, one hit operation. Once installed the readhead can be easily adjusted on the machine using the set-up LED indicator. 1. Prepare scale and surface Ensure scale is cut to correct length and mounting surface has been cleaned and degreased.. Install the scale guide Mount the scale guide to the readhead bracket as shown. Readhead mounting bracket (not supplied) Guide plate Green LED = good signal strength / set-up Red LED = poor signal strength adjustment required, B, -, B- outputs become high impedance NOTE: IB output type LED flashes red. Readheads can be ordered preset to the required resolution or provided so that they can be programmed as needed on the machine to the chosen resolution. This programming is carried out by connecting the readhead to a computer via a programming interface. Screw mounting Spacers Option 1 Option Mounting screws Stick-on reference mark installation 1. Install scale (+ optional cover strip) place the reference mark applicator tool on scale in the correct orientation/required position along the length.. Load the scale into the scale guide Separate the backing paper from the first 40 mm of scale and feed it into the scale guide. Push the scale carefully through to the end of scale mark, ensuring that it does not stick to the mounting surface until it is in position NOTE: To prevent the scale sticking to the mounting surface during this operation it may be necessary to re-apply approximately 0 mm of backing paper to the end of the scale before inserting through scale guide. Self-aligning reference mark applicator tool Magnetic scale. Remove the backing tape from the reference mark sticker and carefully attach it to the surface of the scale by placing it against the end of the applicator tool. NOTE: The correct orientation of reference mark is crucial. The mark on the sticker should be on the same side as the reference mark designators. ttach the end of the scale to the mounting surface with light finger pressure. 4. pply the scale Traverse the axis through its full travel at a slow, steady speed. While moving the axis: pply a light finger pressure to the scale behind the scale guide to attach it to the mounting surface. Gently pull the backing paper away from in front of the scale guide as it is separated. mark designator mark sticker 5. Remove the scale guide When the axis has reached the limit of its travel, lock the axis in place and unbolt the scale guide from the readhead mounting bracket.. Remove the applicator tool leaving the reference mark sticker in the desired position. 6. Ensure complete adhesion pply firm finger pressure along the full length of the scale from the centre outwards to each end. 7. pply cover foil (if used) Degrease the tape surface with alcohol. Install as per scale installation instructions in step onwards.

LM10 system dimensions Dimensions and tolerances in mm. R0min dynamic 4min 8.5 0.5 5.7.5.1 10.1 1.5 1.5 Ø4. 5. 7.7. 4 18.5 4 0.1-1.5 19 reference mark sensor designator reference mark sensor designator 10 NOTE: Ensure recommended M readhead fixing screws are tightened to 0.5 Nm to 0.7 Nm. Readhead installation tolerances General specifications Ride height supply consumption (without any load) 4.5 V to 7 V reverse polarity protected; voltage on readhead (see note below) < 0 m for digital output type < 50 m for analogue output type Environmental sealing IP68 (according to IEC 6059) Pitch ± 0.1 to 1.5 mm Temperature Operating -10 C to +80 C (cable under non-dynamic conditions: -0 C to +85 C) Storage -40 C to +85 C Shock 00 m/s, 11 ms (IEC 60068--7) Vibration 00 m/s, 55 Hz to 000 Hz (IEC 60068--6) Mass Readhead (1 m cable, no connector) 56.4 g, Magnetic scale (1 m) 60 g, Cover foil (1 m).5 g Cable PUR high flexible cable, drag-chain compatible, doubleshielded 8 0.05 mm ; durability: 0 million cycles at 0 mm bend radius Yaw NOTE: Voltage drop over cable; 1 mv/m without load, 54 mv/m with 10 Ω load ± Lateral offset Roll Electrical connections Customer electronics ± Inner shield Extension cable 5 V Output Outer shield ±1.5 mm

Installation guide Connections for digital outputs (Open Collector NPN) male (option ) Complementary not shown Edge separation (µs) Resolution (µm) 5 V Brown 5 White 9 Green 4 Incremental B Blue mark Z Pink Inner Green/Yellow 1, 9 Outer - Case B Z Vcc = 5 V - Vcc = 5 V - R > 1.5 kω, B, Z Readhead Customer electronics Connections for digital outputs (RS4) Incremental mark 15 pin D type male (option D) male (option ) 5 V Brown 7 5 White 9 Green 14 4 - Yellow 6 8 B Blue 1 B- Red 5 7 Z Pink 1 Z- Grey 4 6 Inner Green/ Yellow 15 1, 9 Outer - Case Case Complementary not shown B Z Readhead B Z + Cable Z 0 = 10R Edge separation (µs) Resolution (µm) 10R Customer electronics B Z - 4

Connections for analogue outputs (1 V pp ) 15 pin D type male (option L) male (option ) 60 Incremental 5 V Brown 4, 5 5 White 1, 1 1 Green 9 - Yellow 1 6 Blue 10 4 - Red 8 ( +) - ( ( +) - ( 0.6 V pp - 1. V pp with 10 Ω termination mark Pink - Grey 11 7 Inner - 15 9 Outer - Case Case ( +) - ( 0.8 V pp - 1. V pp with 10 Ω termination + 10 Ω - Connections for analogue outputs (1 µ) male (option ) 60 Incremental 5 V Brown 5 White 1 Green - Yellow 6 Blue 4 - Red 8 0 µ 0 µ 7 µ - 16 µ mark Pink - Grey 7 Inner - 9 Outer - Case 0 µ 8 µ - 1 µ 5