ESP-LXD Controller Decoder Programming Guide

Similar documents
ESP-LXD Controller Programming Guide

ESP-LXD Controller. Installation, Programming & Operation Guide

Rain+Birdt. ESP-LXD Controller Troubleshooting Guide

ESP-LX Modular Controller Programming & Operation Guide

Rain+Birdt. ESP-9V Battery-Operated Controller. User Manual - Table of Contents. Controls and Indicators... 2 Operating Modes... 2

TMC-212 Residential and Commercial Irrigation System Controller. User s Guide

Rain+Birdt. WPX Battery-Operated Controller. User Manual - Table of Contents. Controls and Indicators... 2 Operating Modes... 2

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

ET-8 Series Manual Wall Mount: 8, 16, 24, 32 Stations Pedestal Ultimo: 8, 16, 24, 32, 40, 48 Stations

Rain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components

Table of Contents. Introduction...1 Welcome to the World of WeatherTRAK...1

MSC+ Controller. Operation Manual

Addendum: Rain Dial Installation and Programming Guide Update

ESP-LXME Controller. Installation, Programming & Operation Guide

Owner s Manual. Controller Models SL800, SL1600, SL1620, SL1624, SL4800 PGM RUN PROGRAM NEXT DOWN BACK MANUAL ZONE SYSTEM OFF MANUAL TEST

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

INSTALLATION and OPERATING INSTRUCTIONS

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

WATER CHAMP CONTROLLER

Troubleshooting Guide for the ESP MC controller Feb Royce Mason

IDS. Decoder Controller. Two-wire Decoder Control in an Advanced Industrial Package for the Largest Installations. Programming and Operations Manual

Junior Max (JR Max ) Controller

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Software Ver

TMC-424 T ORO M ODULAR C ONTROLLER 4 TO 24 S TATIONS. User s Guide

EasilyExpandable Up To 12 Stations. With 2-Station Plug-In Modules 3 Watering Programs With: GreenKeeper 212 Features:

Instruction Manual. Outdoor Irrigation Controller. STATION MODELS Available in 6, 9 or 12 stations INDOOR & OUTDOOR MODELS

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

TouchNet. Central Control System for OSMAC. User s Guide. Installation Programming Operation Service

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

10, 12 & 16 STATION MODELS. Soil Moisture Control System INSTRUCTION BOOK

TWC USER MANUAL. Table of content:

INSTALLATION, PROGRAMMING AND OPERATION MANUAL

Chapter 8 Manual System Control

Introduction... 1 Pro-C Components... 2 Pro-C Components Wiring Cabinet... 4 Mounting the Outdoor Controller to Wall... 7

Installation, Programming, & Operation Guide ESP-LX+ and ESP-LXi+

MODULAR RESIDENTIAL AND COMMERCIAL IRRIGATION CONTROLLER. Water Days

How do I delete a. Remove Here

Aqua Turf International, Inc.

Pro-C. Residential and Light Commercial Irrigation Controllers. PCC Series Controller 6, 9, 12 & 15 Station Indoor/Outdoor Models

Battery Operated Controllers

PVR Menu Function Details

ACC2 DECODER Controller

ø 4 mm 3 Image 40 mm Ø 4 mm Ø 4 mm

User s Guide. ECx Features: Automatic Sprinkler System Timer

Users Manual. Models 96954, 96956, 96874, PN ra. dimensions: flat: w: 14" h: 5" finished: w: 7" d: " h: 5" proof no: 2. date:

User s Guide. ECx Features: Automatic Sprinkler System Timer

User Guide AC/DC 2 AC/DC 4 AC/DC 6 AC/DC 9 DC IP68 AC IP65

Understanding and Programming Irrigation Controllers

Wireless Irrigation Controller. User Manual.

User Guide. Color Touchscreen Programmable Thermostat. ComfortSense Model: 13H /2017 Supersedes

Marks and Grades Project

Quick Setup Guide for IntelliAg Model NTA

Digital Video User s Guide THE FUTURE NOW SHOWING

USER DOCUMENTATION. How to Set Up Serial Issue Prediction

9070 Smart Vibration Meter Instruction Manual

Manual and Guidelines. For. Library Automation Software Version

VNS2210 Amplifier & Controller Installation Guide

Digital Video User s Guide THE FUTURE NOW SHOWING

HV/PHA Adjustment (PB) Part

Quick Setup Guide for IntelliAg Model CTA

476PR / 476PRI IRRIGATION CONTROLLER

Part names (continued) Remote control

Syntor X Flash Memory Module Revision C

User interface. Abbreviations / Meanings

SMART WIFI SPRINKLER TIMER

3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

REMOTE DISPLAY WIRELESS DECODER MK II

DX2. User Manual R B R B. RMIS Part No Rev..A

VARIABLE SPEED USER MANUAL. Premium Efficiency Variable Speed Motor

446PR / 446PRI IRRIGATION CONTROLLER

EZ Pro Instructions Zone Chart

pc-based controller user guide for vers software

Echo Sounder and Echo Generator

NOTICE: This.pdf file should not. regarding the file (e.g., color, text

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

KF200 PORTABLE MANUAL

Training Note TR-06RD. Schedules. Schedule types

DCL Time Controller WTDCL. Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group

MultiSpec Tutorial: Visualizing Growing Degree Day (GDD) Images. In this tutorial, the MultiSpec image processing software will be used to:

Modular Lube Lubrication Systems System Controls

USER & ENGINEER INSTRUCTION MANUAL

ICOD PLUS instruction manual

USER MANUAL KGN1080P32VD

Mixer Measurement Wizard Operation Manual

Software Manual Control Panel for Professional Single Booster Units Models: MM3 BW3

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Compact live fiber identifier with integrated optical power meter

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Application Note 11 - Totalization

My XDS Receiver- Affiliate Scheduler

The PHI VersaProbe operates with two essential software programs: PHI Summitt and Vacuum Watcher. A third program, MultiPak, handles data reduction.

Digital TV. User guide. Call for assistance

Goodmans Helpline Phone Number

OPERATION AND MAINTENANCE

Defrost Control Installation and Programming of Version 3.1 Cards

Operating Procedures for RECO1 & RECO2

SPIRIT. SPIRIT Attendant. Communications System. User s Guide. Lucent Technologies Bell Labs Innovations

KGNϭϬϴϬWWZKϮϮs USER MANUAL

DATA PROJECTOR XJ-S30/XJ-S35

Transcription:

ESP-LXD Controller Decoder Programming Guide

Contents How To Use The Programming Guide... 1 Program and Decoder Information...1 Apply Decoder Address Labels...2 Fill Out Programming Guide...2 Sample Program Information...3 Sample Decoder Information...5 Barcode Scanning... 6 Barcode Scanning Pen Options...6 Barcode Scanning Pen Setup...7 Unitech MS100-RCB00-SG...7 Unitech MS100-2...8 Test Barcode Scanning Pen...9 Scan Field Decoder Addresses...10 Programming... 12 Program Information...12 Decoder Information...14 Symbols OTE: Symbol is intended to alert the user to important operating, functionality or maintenance or installation instructions. DIAL: Symbol indicates that the user is required to turn the dial on the controller to the appropriate setting in order to follow subsequent instructions as described in that section. REPEAT: Symbol indicates that a repetition of previous steps or actions may be required in order to continue or complete the controller programming process. For technical assistance contact Rain Bird at +1-866-544-1406 or EU : +33 4 42 24 44 61 Visit us on the web at www.rainbird.com Storing the Programming Guide Return the Programming Guide to a permanent, safe location when you re finished working with it. We recommend hanging it on the hook inside the controller cabinet door as shown below. OTE: When printing this document, be sure to select Actual size and Landscape orientation in the print dialog box.

How To Use The Programming Guide Program and Decoder Information A B Print pages 12-33 of the Programming Guide. Align the Program Information charts (pages 12 and 13) to the corresponding data on the Decoder Information charts (pages 14-33). PAGE 12 PAGE 13 PAGES 14, 16, 18, 20, 22, 24, 26, 28, 30, 32 PAGES 15, 17, 19, 21, 23, 25, 27, 29, 31, 33 ESP-LXD Controller 1

Apply Decoder Address Labels Before you begin programming, apply your field decoder barcode labels to the appropriate fields on the Programming Guide. A 1 Carefully peel the station, master valve, flow or weather sensor sensor decoder barcode label off of the decoder. OTE: An optional Programming Backup Cartridge (PBC) is available for the ESP-LXD controller, which allows you to create and Restore multiple Backups of irrigation programs. With a PBC cartridge installed, you can also set up Field Decoder addresses by using a barcode scanning pen to read the removable barcode labels attached to Rain Bird s field decoders. See Section E of the ESP-LXD Controller Installation, Programming and Operation Guide for more details. Or see page 6 of this Programming Guide for more details on setting up a barcode scanning pen. Fill Out Programming Guide Before you begin programming, fill out the Programming Guide. Sample Programming information is shown on the following pages. C Enter information about your system hardware and settings in the appropriate fields on the Programming Guide. B Apply the decoder address labels in the appropriate fields on the Programming Guide. 3 2 Repeat this process to apply additional barcode labels to the programming chart. 2 ESP-LXD Controller

Sample Program Information A B C D E F Enter custom Program ames for your programs in these fields. Enter Days To Water for each program: For Custom cycle, check the specific days of the week to include for irrigation. For Cyclical schedule, enter the cycle period. For example, a 3 DayCycle indicates irrigation will occur every third day. For Odd/Even day watering, check Odd, Even, or Odd 31. Enter Watering Start Time(s). You may enter up to eight start times for each program, but only one start time is needed for a program to run. Circle either am or pm. Enter the Seasonal Adjust by Month percentages (if you are using them). Check O in the Monthly Seasonal Adjust row for each program that will use the monthly percentages. Enter the Seasonal Adjust by Program percentage (if you are using it). The Seasonal Adjust for sample Program A is set to 80%, and the Monthly Seasonal Adjust box is left unchecked. G 4 7 8 9 Enter the Delay for each program (if desired). In the sample, Program A has a one-minute delay between valves. When valve 1 ends, the controller waits one minute before starting valve 2. There will also be a one-minute delay between valve 2 and valve 3, etc. A station delay setting applies to all programs. 55 60 70 75 85 90 100 100 90 85 75 65 Turf H I 1 2 X X X Enter the Maximum umber of Simuls allowed per program. In the sample, Program A is allowed to run a maximum number of 4 programs simultaneously. Enter the Water Window Start and End Time(s) for each program (if you re using them). Circle either am or pm. Shrub 10:00 11:45 1:00 2:15 4:30 80 1 min 4 3 X X 5:30 X X X 3 6 5 10:00 6:00 ESP-LXD Controller 3

Sample Program Information Enter the Maximum Flow Rate. R List of Rain Bird decoder models. A Apply Master Valve (MV) Decoder Address Labels in these fields. O Enter Days of the Week for the water window to be active. S Enter the Maximum Flow Rate for each Flow Zone in these fields. B C D Enter Description of the MV. Check if the MV is normally open (O) or normally closed (C). Check if the MV is allowed to open during the MV Manual Water Window. P Q Check Pipe Size Units of measurement that you re using; inches or metric. Enter the Flow Units that you re using; GPM or other. T U V List of Rain Bird valve types. Enter the System Valve Types that your system uses. List of Rain Bird flow sensors. E Apply Flow Decoder Address Labels in these fields. n o m p q r F G H I J K L M Enter Description of the flow sensor. Enter the Type of flow sensor. Specifies which Master Valve (MV) the sensor is connected to. Apply Weather Decoder Address Labels in these fields. Enter Description of the weather sensor. Enter the Type of weather sensor. Check which Action the sensor performs (prevent or pause). Enter the Master Valve (MV) Manual Water Window Open and Close Time(s). Circle either am or pm. a b c d e f g h i j k l 7:00 4:00 120 X X X X Pump Meter Pump Meter WR2-RC WR2-RFC X X FS400P FS200P Rain Freeze X X X X 1 2 120 80 1 2 s t u v 4 ESP-LXD Controller

Sample Decoder Information A Apply Decoder Address labels in these fields. B C Enter description of the Valve Type. Enter Description of the decoder model. a b c d e f g h D E Check which Master Valve (MV) the station uses. Enter the Flow Rate. V1 V2 FD101 FD102 X X 52 26 X X X X X X F Check if the station obeys a Local. G Check if the station obeys a Weather. H Check the FloZone source. I J Enter description of the. Check the station s Priority here. i j k l m K L Enter the Cycle Time (if you re using Cycle+Soak TM ). Enter the Soak Time (if you re using Cycle+Soak TM ). Entry-Sprays Entry-Color Beds X X 5 min 30 min 10 min 5 min M Enter Run Time(s) for each program (A, B, C and D). ESP-LXD Controller 5

Barcode Scanning Barcode Scanning Pen Options To take full advantage of ESP-LXD Controller features, an optional barcode scanning pen is recommended for Decoder setup. Rain Bird recommends using a Unitech MS100-RCB00-SG Handheld Pen/Wand Scanner. OTE: The Barcode Scanning Pen must be set up in order to use it with the ESP-LXD Controller and ESP-LXD decoders. See pages 7-8 for Barcode Scanning Pen setup. MS100-RCB00-SG Unitech also offers an earlier version of their barcode scanning pen, the MS100-2. Either of these barcode scanning pens will work with the ESP-LXD Controller, once setup properly. For more information on these products or to purchase a barcode scanning pen, visit the Unitech website: orth America Latin America Europe http://us.ute.com http://latin.ute.com http://eu.ute.com 6 ESP-LXD Controller

Barcode Scanning Pen Setup Unitech MS100-RCB00-SG Follow the instructions by scanning the 4 Setup Barcodes that are shown below. A Scan the first barcode lengthwise as shown. You ll hear audible beeps to confirm that the scan was successful. OTE: If you do not hear beeps after each scan then repeat the scanning process until you hear the beeps. Setup Barcode 1 Setup Barcode 2 B Scan the second barcode and again you ll hear audible beeps. Setup Barcode 3 Setup Barcode 4 Scan the remaining barcodes. Be sure to listen for the beeps after each scan to confirm the scan was successful. The barcode scanning pen is now ready for use. ESP-LXD Controller 7

Unitech MS100-2 Follow the instructions by scanning the 2 Setup Barcodes that are shown below. A Scan the first barcode lengthwise as shown. You ll hear audible beeps to confirm that the scan was successful. OTE: If you do not hear beeps after each scan then repeat the scanning process until you hear the beeps. Setup Barcode 1 Setup Barcode 2 B Scan the second barcode and again you ll hear audible beeps. The barcode scanning pen is now ready for use. 8 ESP-LXD Controller

Test Barcode Scanning Pen Turn the controller dial to ETM/IQ/PBC Settings. C D Scan any station umber Barcode (as shown on pages 14-33 of the Programming Guide). You ll hear an audible beep to confirm when the scan was successful. The Success! screen will appear and the station field will display the station number of the scanned barcode. 3 4 A B The PBC Main Menu appears. Press the Down Arrow button to select Test Barcode Pen; then press ext. The PBC Test Barcode Pen screen appears with instructions. OTE: Return the Programming Guide to a permanent, safe location when you re finished working with it. We recommend hanging it on the hook inside the controller cabinet door. 1 2 ESP-LXD Controller 9

Scan Field Decoder Addresses Set up field decoders automatically by scanning. A CAUTIO: Barcode scanning replaces any previous decoder addresses stored in the controller. Be sure to complete the previous Test Barcode Scanning Pen process before starting as the test process will not update or replace your decoder addresses. Ensure that the station Decoder Address Labels are affixed in the proper locations on the Programming Guide. B C The PBC Main Menu appears. Press the Down Arrow button to select station Setup; then press ext. The PBC station Setup (Scan When Ready) screen appears. 2 3 D On the Programming Guide, scan a station umber barcode and corresponding station Decoder Address Label in sequence. You ll hear audible beep(s) to confirm when scans are successful. 1 Turn the controller dial to ETM/IQ/PBC Settings. 4 10 ESP-LXD Controller

E The Successful Scan screen appears and the station and Decoder fields will be updated with the scanned barcode data (the screen will always display the most recently scanned data). Press the Save button to store the scanned station umber and station Decoder Address in the controller. Or else press Cancel to go back or retry scanning again. OTE: It s not necessary to scan Field Decoder addresses sequentially., or MV addresses can be scanned in any numeric order. For example, you could scan station 2 before scanning station 1, if necessary. F To scan master valve, flow sensor or weather sensor decoders; from the Scan When Ready screen, press the Type button to select the desired device. Then repeat the scanning process as previously described. 5 6 OTE: If either barcode does not scan on the first attempt, try scanning one or both barcodes again until you hear the beep(s) and until the screen has updated to show both the station (or or MV) umber and the Decoder Address. If scanning problems persist, you can still enter decoder addresses manually. See ESP-LXD Controller Installation, Programming & Operation Guide, Section B, Setup Wizards for more details. Repeat this process and continue to scan and set up additional Field Decoder addresses as desired. OTE: Even if you don t plan to use a barcode scanning pen, we recommend carefully removing the peel-off barcodes from your field decoders and affixing them to the proper positions in the Programming Guide. ESP-LXD Controller 11

Programming Program Information Monthly Seasonal Adjust % JA % FEB % MAR % APR % MAY % JU % JUL % AUG % SEP % OCT % OV % DEC % Default Values for Monthly Seasonal Adjust = 100% Program Info Program A Program B Program C Program D Program ame Select Days To Water (Mon-Sun) For Custom - OR - Select Days Watering Allowed For on-custom Set Watering Start Times M T WT F S S Day Cycle Even Odd Odd 31 M T WT F S S Day Cycle Even Odd Odd 31 M T WT F S S Day Cycle Even Odd Odd 31 M T WT F S S Day Cycle Even Odd Odd 31 1 am / pm am / pm am / pm am / pm 2 am / pm am / pm am / pm am / pm 3 am / pm am / pm am / pm am / pm 4 am / pm am / pm am / pm am / pm 5 am / pm am / pm am / pm am / pm 6 am / pm am / pm am / pm am / pm 7 am / pm am / pm am / pm am / pm 8 am / pm am / pm am / pm am / pm Seasonal Adjust % % % % Monthly Seasonal Adjust O O O O Delay Maximum Simuls Per Program Program Water Window Start Time Program Water Window End Time am / pm am / pm am / pm am / pm am / pm am / pm am / pm am / pm 12 ESP-LXD Controller

MV Manual Water Window Window Open Time Window Closed Time Max. Flow Rate am / pm am / pm Active Days Per Week MTWT F S S Pipe Size Units Inch MM Flow Units GPM LPS LPM M3/HR Decoder Models FD101 1 Address FD102 1 Address 1 Valve Per Address 2 Valves Per Address FD202 2 Addresses 2 Valves Per Address FD401 4 Addresses 1 Valve Per Address FD601 6 Addresses 1 Valve Per Address MV umber Flow umber MV 1 2 3 4 5 F-SE Master Valve Decoder Address Label Flow Decoder Address Label Description Description MV Valve Type ormally Open / Closed /O /C /O /C /O /C /O /C /O /C Type Open In Water Window YES YES YES YES YES Uses MV FloZone Max. Flow Rate Default System Valve Types FZ-1 FZ-2 FZ-3 FZ-4 FZ-5 Type/ Solenoids Default Rain Bird Valve Types V1 1 PGA, PEB, PESB, V2 2 GB, EFB-CP V3 1 BPEB, BPES, V4 2 Golf VIH Rotors V5 1 Pump Start Relay 1 1 2 2 3 3 4 4 5 5 System Valve Type Valve Type V1 V2 V3 V4 V5 Valves Per Address Weather umber W-SE Weather Decoder Address Label Description Type Action Type FS100B Description 1 Brass Tee 1 2 3 Local Prevent Prevent Pause Prevent Pause Prevent Pause Flow s FS150P FS200P FS300P FS400P FS350 Custom 1 1/2 PVC Tee 2 PVC Tee 3 PVC Tee 4 PVC Tee Insert User Defined ESP-LXD Controller 13

Decoder Information umber 1 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 14 ESP-LXD Controller

1 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ESP-LXD Controller 15

umber 21 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 16 ESP-LXD Controller

21 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 ESP-LXD Controller 17

umber 41 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 18 ESP-LXD Controller

41 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ESP-LXD Controller 19

umber 61 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 20 ESP-LXD Controller

61 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 ESP-LXD Controller 21

umber 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 22 ESP-LXD Controller

81 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 ESP-LXD Controller 23

umber 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 24 ESP-LXD Controller

101 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 ESP-LXD Controller 25

umber 121 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 26 ESP-LXD Controller

121 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 ESP-LXD Controller 27

umber 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 28 ESP-LXD Controller

141 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 ESP-LXD Controller 29

umber 161 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 30 ESP-LXD Controller

161 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 ESP-LXD Controller 31

umber 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 Decoder Address Label Valve Type Decoder Model Uses MV Flow Rate Local Weather FloZone Source 32 ESP-LXD Controller

181 Description Priority = on Irrigation Cycle Time Soak Time Program A Run Time Program B Run Time Program C Run Time Program D Run Time 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 ESP-LXD Controller 33

RAI BIRD CORPORATIO 6991 E. Southpoint Road Tucson, AZ 85756 2015 Rain Bird Corporation Rain Bird, Simuls, FloManager, FloWatch and FloZone are registered trademarks of Rain Bird Corporation. All rights reserved. Unitech, MS100-RCB00-SG and MS100-2 are trademarks of Unitech Electronics Co., LTD. www.rainbird.com/lxd 28SE15 - D40760 - Revision B