Federal Communications Commission and Industry Canada Radio Frequency Interference Statements This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used properly in strict accordance with the instructions contained herein, may cause interference to radio communication. It has been tested and found to comply with the limits for Class A computing devices in accordance with the specifications found in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to take whatever means may be necessary to correct the interference at his own expense. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This apparatus does not exceed the Class A limits for radio noise emission set out in the Radio Interference Regulation of Industry of Canada. Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada. FCC PART 15 COMPLIANT
g GE Interlogix Fiber Options INSTRUCTION MANUAL MODEL S700VT-MST MINIATURE VIDEO TRANSMITTER GENERAL This manual is a guide to the installation and operation of the S700VT-MST fiber optic video transmitter. Please read the entire manual before installing the equipment. NOTE: The series numbers S700VR is used the describe all receiver models unless noted otherwise. The S700VT-MST video transmitters system transmit one video signal one from a camera to a monitoring station over one multimode fiber. The S700VT-MST can be used with the S700VR or S702VR series receivers. A complete system consists of one transmitter and one receivers. Unpacking the Unit In the event that anything is missing from the following list, contact your authorized Fiber Options dealer or representative. S700VT-MST Transmitter Instruction manual Save the original packing materials in case it becomes necessary to return the unit. FIGURE 1: BASIC SYSTEM DIAGRAM Video In S700VT-MST one optical fiber S700VR Video Out FEATURES The S700VT-MST transmitter housing is extremely small measuring 1.5 in. (38 mm) by 1.04 (26 mm) by 24 mm (0.94 in). An ST optical connector is fixed to one end, while a coaxial cable with BNC connector and a removable 2-pin screw-terminal power connector are attached at the opposite end. The S700VT-MST transmitter can be used with any of the following receivers: S700VR-EST, S700VR-RST, S702VR-RST. The S702VR-RST supports two transmitters. All the receivers feature a diagnostic LEVEL/LOSS TM LED to indicate the presence of valid fiber signal. (S702V cards have two such LEDs). Refer to TROUBLESHOOTING for more information. Rackmount receivers are designed to be mounted in a standard 19- inch card cage (515R1 or 517R1). Electrical power input is derived from the card cage. Fiber Options 80 Orville Drive, Bohemia NY 11716-2533 fiber@ge-interlogix.com US Tel: 631-567-8320 or 800-342-3748 Fax: 877-FiberFax (877-342-3732 toll free) or 631-567-8322 For international offices, see the back cover.
INSTALLATION The S700VT-MST transmitter is intended to be located on or near a CCTV camera. If the camera is mounted outdoors, the S700VT-MST must be mounted inside the camera housing. Make sure there is sufficient space for making the various cable, electrical, and fiber connections. Velcro TM fastener tape is provided for mounting the S700VT- MST to any smooth, flat surface. See Figure 2 for unit dimensions. 1. Adhere the fastener tape to the transmitter by removing the protective backing from the gummed tape. Firmly press the tape to the unit. 2. Fasten the other piece of Velcro to the selected surface in the same way. The S700VT-MST can now be mounted to the surface by attaching the two pieces of fastener tape to each other. CONNECTIONS All fiber-optic links convert electrical signals into a light source at the transmitter and convert the light back to electrical signals for output at the receiver. CAUTION: Make sure all peripheral equipment that will be connected to the fiber unit is turned OFF during installation. Video Cable Connection Connect the video equipment, such as a camera, to the S700VT-MST transmitter using the attached coaxial cable. Fiber Optic Cable Connection The standard optical connector on S700VT-MST units is the ST type. Connect the pre-terminated fiber to the two fiber units. Power Connections A removable 2-pin screw-terminal connector is provided for the electrical connection. 1. Make sure the power supply is not connected to any power source and attach the leads from the power supply to the appropriate terminals as follows: Pin 1: +13.5 VDC (DC+) or 12-14 VAC Pin 2: Ground (DC-) or 12-14 VAC 2. Plug the power supply into a suitable outlet. Once the S700VT-MST has been installed and the other end of the fiber connected to a suitable receiver, power up the peripheral equipment. TROUBLESHOOTING Operation of a system including an S700VT-MST transmitter can be monitored with the LEVEL/LOSS TM LED on the S700VR or S702VR receivers. When green, LEVEL/LOSS indicates the presence of sufficient optical and video signals being received from the transmitter. If unlit, check fiber and all connections and splices. Also check that the transmitter is connected to an operating video source, is on, and is connected to the receiver via the fiber. FIGURE 2: MODULE DIMENSIONS 2 fiber@ge-interlogix.com free phone: 800.342.3748 free fax: 877.342.3732
NOTE: A blank video screen can be a valid video input. If the S700V fails to operate and the cause of the failure cannot be determined, it may be necessary to contact Fiber Options. MAINTENANCE There is no operator maintenance other than keeping the units clean. CONTACTING FIBER OPTIONS If you cannot determine the cause of your problem and are in the U.S. or Canada, call the Fiber Options Headquarters in Bohemia, NY. If you are outside the U.S. or Canada, call the closest international office listed on the back page of this manual. Have the following information available: exact model number and product code of your fiber-optic links, and a listing of the diagnostic indicators and their respective color/condition. RETURNS TO FIBER OPTIONS If any equipment must be returned to Fiber Options for repair or replacement, you must obtain authorization from our Return Authorization department before shipping. If you are in the U.S. or Canada, call our NY headquarters at 631-567-8320 or 800-342-3748. Customers in other countries should contact their regional representative listed on the back cover of this manual. A Return Authorizations representative will provide full instructions for returning your product at that time. NOTE: All authorized returns must be clearly marked with the Return Authorization information. Please follow the instructions completely. NOTE: Fiber Options will not accept return delivery of any product without prior authorization. SHIPPING AND PACKAGING Before shipping or transporting your Fiber Options unit, pack it securely to prevent damage that could occur in transit. Use care to protect all connectors, LEDs, and corners from possible damage. fiber@ge-interlogix.com free phone: 800.342.3748 free fax: 877.342.3732 3
... light years ahead INSTRUCTION MANUAL 11-M700V-A Copyright 2001 by FIBER OPTIONS. All rights reserved. 030919 All specifications are subject to change without notice. Information furnished by FIBER OPTIONS is believed to be accurate and reliable. However, no responsibility or liability is assumed by FIBER OPTIONS for its use, nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or other rights of FIBER OPTIONS. 80 Orville Drive, Bohemia NY 11716-2533 fiber@ge-interlogix.com US Tel: 631-567-8320 Fax: 631-567-8322 800-342-3748 877-FiberFax (877-342-3732) UK Tel: +44 113 238 1668 Fax: +44 113 253 8121 Australia Tel: +61 3 9676 0270 Fax: +61 3 9646 7005 France Tel: +33 01 60 86 54 53 Fax: +33 01 60 86 86 04 Germany Tel: +49 700 34237678 Fax: +49 36256 21991 Hong Kong Tel: +852 2907 8108 Fax: +852 2142 5063 Latin America Tel: 800-342-3748 Fax: 877-342-3732